Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Demonstrating magnetic field robustness and reducing temporal T1 noise in transmon qubits through magnetic field engineering

The coherence of superconducting transmon qubits is often disrupted by fluctuations in the energy relaxation time (T1), limiting their performance for quantum computing. While background magnetic fields can be harmful to superconducting devices, we demonstrate that both trapped magnetic flux and externally applied static magnetic fields can suppress temporal fluctuations in T1 without significantly degrading its average value or qubit frequency. Using a three-axis Helmholtz coil system, we applied calibrated magnetic fields perpendicular to the qubit plane during cooldown and operation. Remarkably, transmon qubits based on tantalum-capped niobium (Nb/Ta) capacitive pads and aluminum-based Josephson junctions (JJs) maintained T1 lifetimes near 300 μs even when cooled in fields as high as 600 mG. Both trapped flux up to 600 mG and applied fields up to 400 mG reduced T1 fluctuations by more than a factor of two, while higher field strengths caused rapid coherence degradation. We attribute this stabilization to the polarization of paramagnetic impurities, the role of trapped flux as a sink for non-equilibrium quasiparticles (QPs), and partial saturation of fluctuating two-level systems (TLSs). These findings challenge the conventional view that magnetic fields are inherently detrimental and introduce a strategy for mitigating noise in superconducting qubits, offering a practical path toward more stable and scalable quantum systems.

Abdisatarov, Bektur [Fermilab; Jefferson Lab]↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Laminar Flow Heat Transfer In Helical Oval-Twisted Tube for Heat Exchanger Applications

The heat transfer performance of a novel tube configuration that combines the swirling velocity induced by oval-twisting and secondary flow generated by a helical geometrical flow path is presented. The Nusselt number (Nu) and friction factor (f) are compared for the laminar flow regime (Re = 250- 2000) under isothermal wall conditions. Under the same flow and boundary conditions, the oval-twisted helical tube increased the Nu and slightly increased the f over the circular helical tube. The best performance with the highest Nuand lowest f occurs at the coil curvature ratio (d h /D) of 0.17. The quantified enhancement performance factor (h) shows a 46 - 56% increase for the oval-twisted helical tube over the circular helical tube with d h /D = 0.17. Correlations for the Nu and f are developed and agreed with the numerical results: ± 6% and ± 5% for the Nu and f, respectively.

42 ENGINEERING↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Self-field measurements of an HTS twisted stacked-tape cable conductor

For a twisted stacked-tape cable (TSTC) conductor composed of REBCO tapes, self-field measurements were conducted with Hall sensors. In the measurements, a 650 mm diameter single turn coil wound with the TSTC conductor, which was made with 48 REBCO tapes whose width was 6 mm, was utilized as a test sample. Based on the measurement results, the current distribution of the TSTC conductor was investigated with analytical models. The analytical results indicate the current distribution of the TSTC is uniform under the condition that the operating current is 10 kA and the sample temperature is approximately 30 K. On the other hand, the current distribution is not uniform at the excitation and the degauss of the TSTC conductor with the ramp rate of 50 A/s.

Obana, T.↗

Investigation of HTS Twisted Stacked-Tape Cable (TSTC) Conductor for High-Field, High-Current Fusion Magnets

The critical currents of a twisted single-tape were measured at 4.2 K in fields up to 17 T. It was confirmed that the critical current of a twisted-tape was similar to that of a flat tape in c-axis fields. Based on the single-tape critical-currents, a 40-tape (4-mm width) twisted stacked-tape cable (TSTC) conductor was experimentally evaluated at fields up to 17 T at 4.2 K. It was found that the Lorentz load degradation of the TSTC conductor was negligible at the end of a cyclic test. The TSTC cabling method has been considered to be suitable for developing a high-field high-current REBCO conductor for magnet applications as well as power transmission cables. A method to fabricate the inner legs of a D-shape toroidal field coil using a TSTC conductor has been discussed. This method allows the conductor to properly resist the transverse Lorentz load and mitigate ac loss issues by adopting a parallel-HTS-tape flat cable configuration where necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Atomic layer etching with pulsed plasmas

A system and method for rapid atomic layer etching (ALET) including a pulsed plasma source, with a spiral coil electrode, a cooled Faraday shield, a counter electrode disposed at the top of the tube, a gas inlet and a reaction chamber including a substrate support and a boundary electrode. The method includes positioning an etchable substrate in a plasma etching chamber, forming a product layer on the surface of the substrate, removing a portion of the product layer by pulsing a plasma source, then repeating the steps of forming a product layer and removing a portion of the product layer to form an etched substrate.

Donnelly, Jr., Vincent M.↗

Relaxation time estimation in surface NMR

Technologies including NMR relaxation time estimation methods and corresponding apparatus are disclosed. Example techniques may include performing at least one single-pulse acquisition sequence, the single-pulse acquisition sequence comprising transmitting a single modulated pulse with a surface coil, wherein the phase, frequency, or amplitude of the single modulated pulse is varied during the single modulated pulse, and wherein the single modulated pulse excites a transverse magnetization component within a subsurface fluid. The resulting NMR signal may be recorded on at least one receiving device, including recording the NMR signal associated with the transverse magnetization component excited by the single modulated pulse. Processing techniques may be applied in which recorded NMR response data are used to estimate NMR properties and the relaxation times T1 and T2* as a function of position as well as one-dimensional and two-dimension distributions of T1 versus T2* as a function of subsurface position.

58 GEOSCIENCES↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

25 ENERGY STORAGE↗

Characterizing Acoustic Signals in the Buildup to a Magnet Quench

In superconducting magnets, the irreversible transition of a portion of the coils to the resistivestate is called a quench. Repeated quenches are very costly, but there is currently no way ofanticipating quenches before they arrive, and relatively little is understood theoretically about thebuildup to a quench. In this study, we examine the relationship between the energy of acoustic eventsin the magnet during training and the minimum quench energy (MQE), an analytical formula forthe minimum possible energy needed to sustain a quench. We nd a tendency for the ratio ofevent energy to MQE (henceforth known as the "energy ratio") to increase over time in some rampsbut not others. Moreover, there are occasional outlier events that are unusually strong, and thereappears to be no consistent threshold for a quench. We further uncover concerns about the validityof the acoustic data, including signicant variations in the relative strengths of an event in dierentsensors and a few inconsistencies between sensors concerning the arrival times of acoustic events. Weultimately conclude that, while the energy ratio does often increase over time, any further researchendeavors will require the data to be improved in many ways.

43 PARTICLE ACCELERATORS↗

EMPIRICAL VALIDATION OF MULTI-ZONE BUILDING AND HVAC SYSTEM MODELS UNDER UNCERTAINTY

This study implemented a framework of empirical validation of building energy models under uncertainty to a set of controlled experiments that aim to validate multi-zone building and HVAC system models. Energy models were created through iterative acquisitions of information and data and uses measurement data from various types of sensors as both inputs and as observations to validate predictions. Experimental and modeling uncertainties were quantified and propagated accordingly, and probabilistic accuracy metrics were used to evaluate the agreement between model predictions and observations under uncertainty. Sensitivity analysis was performed to identify the most influential uncertainties that will be prioritized to be addressed in the next steps. Current results of two cooling tests show an overall good agreement between predictions and observations on a set of HVAC system outputs despite considerable and influential uncertainty in DX cooling coil COP. Agreements on zone-level responses vary notably among individual rooms, likely because of significant uncertainties in room radiation heat gain and system supply air.

Li, Qi↗

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗

Unified conductor to lower the resistance between a planar transformer and one or more inductors

An apparatus is provided including a transformer including a first printed circuit board having one or more conducting layers, the one or more conducting layers forming, at least in part, a transformer coil; at least one inductor; and at least one continuous piece of conducting material external to the printed circuit board, where the at least one continuous piece of conducting material forms a connection between the transformer and the at least one inductor. A method is also provided for assembling a switched-mode power supply.

Coteus, Paul W.↗

The Response of Polarized Protons in Solid Hydrogen-Deuteride(HD) to Electron Beams

Solid frozen-spin polarized targets of hydrogen-deuteride(HD) have been proven advantageous in photon beam experiments, where they exhibit immeasurably long spin-relaxation times(T1). The present research investigates their potential applicability to experiments with minimum-ionizing charged-particle beams. Studies have been conducted with sub-nanoAmp CW currents of 10 MeV electron beams at the newly commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). Since the energy deposition is almost independent of electron beam energy, these UITF experiments provide insight on the expected performance at the GeV energies required in typical JLab experiments. A horizontal in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at about 0.1K and 1 Tesla. NMR coils sur rounding the HD target have been used to monitor hydrogen polarization. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. The behavior of a 40% H-polarized frozen-spin target has been tracked while exposed to beams under various conditions. Polarization loss has been observed to be approximately proportional to dose, with the target polarization dropping to 1/e of its initial value after about 6 µC cm2 , about 4 ? 1013 beam particles/cm2 . A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1

Wei, Kevin↗

Increase resistance for efficient heating

Conductors for use in heating systems are provided. The conductors are configured to have an extended current path for the current and increased resistance as seen by the current. The heating system may be an induction system. For example, the conductor may comprise a conductive material having a surface which faces an induction coil of an oscillating circuit. This surface may have a predetermined pattern of peaks and valleys. The peaks and valleys form a non-linear current path for the induced current when exposed to an electromagnetic field generated by the oscillating circuit. Other conductors such as a heat pipe may be used. The pipe may have walls with varying thicknesses over its length. The varying thicknesses may include a first thickness and a second thickness which alternate. The heat pipe may be used in an induction or direct contact heating system where AC is directly applied to the pipe.

Kisner, Roger A.↗