Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Coherent Uncertainty Analysis of Aerosol Measurements from Multiple Satellite Sensors

Aerosol retrievals from multiple spaceborne sensors, including MODIS (on Terra and Aqua), MISR, OMI, POLDER, CALIOP, and SeaWiFS altogether, a total of 11 different aerosol products were comparatively analyzed using data collocated with ground-based aerosol observations from the Aerosol Robotic Network (AERONET) stations within the Multi-sensor Aerosol Products Sampling System (MAPSS, http://giovanni.gsfc.nasa.gov/mapss/ and http://giovanni.gsfc.nasa.gov/aerostat/). The analysis was performed by comparing quality-screened satellite aerosol optical depth or thickness (AOD or AOT) retrievals during 2006-2010 to available collocated AERONET measurements globally, regionally, and seasonally, and deriving a number of statistical measures of accuracy. We used a robust statistical approach to detect and remove possible outliers in the collocated data that can bias the results of the analysis. Overall, the proportion of outliers in each of the quality-screened AOD products was within 12%. Squared correlation coefficient (R2) values of the satellite AOD retrievals relative to AERONET exceeded 0.6, with R2 for most of the products exceeding 0.7 over land and 0.8 over ocean. Root mean square error (RMSE) values for most of the AOD products were within 0.15 over land and 0.09 over ocean. We have been able to generate global maps showing regions where the different products present advantages over the others, as well as the relative performance of each product over different landcover types. It was observed that while MODIS, MISR, and SeaWiFS provide accurate retrievals over most of the landcover types, multi-angle capabilities make MISR the only sensor to retrieve reliable AOD over barren and snow / ice surfaces. Likewise, active sensing enables CALIOP to retrieve aerosol properties over bright-surface shrublands more accurately than the other sensors, while POLDER, which is the only one of the sensors capable of measuring polarized aerosols, outperforms other sensors in certain smoke-dominated regions, including broadleaf evergreens in Brazil and South-East Asia.

remote sensing↗

Coherent Doppler Lidar for Measuring Altitude, Ground Velocity, and Air Velocity of Aircraft and Spaceborne Vehicles

A Doppler lidar sensor system includes a laser generator that produces a highly pure single frequency laser beam, and a frequency modulator that modulates the laser beam with a highly linear frequency waveform. A first portion of the frequency modulated laser beam is amplified, and parts thereof are transmitted through at least three separate transmit/receive lenses. A second portion of the laser beam is used as a local oscillator beam for optical heterodyne detection. Radiation from the parts of the laser beam transmitted via the transmit/receive lenses is received by the respective transmit/receive lenses that transmitted the respective part of the laser beam. The received reflected radiation is compared with the local oscillator beam to calculate the frequency difference there between to determine various navigational data.

Amzajerdian, Farzin↗

A Spatially Coherent Global Soil Moisture Product with Improved Temporal Resolution

Global soil moisture products that are completely independent of any type of ancillary data and solely rely on satellite observations are presented. Additionally, we further develop an existing downscaling technique that enhances the spatial resolution of such products to approximately 11 km. These products are based on internal modules of the Land Parameter Retrieval Model (LPRM), an algorithm that uses the radiative transfer equation to link soil moisture, vegetation optical depth and land surface temperature to observed brightness temperatures. The soil moisture product that is independent of any type of ancillary data uses the internally calculated dielectric constant as a soil moisture proxy. This data product is not influenced by errors associated with coarse-scale global soil property maps or by any other type of forcing (e.g. re-analysis) data and is therefore solely based on satellite microwave observations. The second step builds upon recent developments to increase the spatial resolution of the LPRM retrievals using a smoothing filter downscaling method. With this method we can attain a spatial resolution that can be more useful at the scale of local and regional hydrological studies as well. The steps presented in this paper were applied to observations from the Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E). The newly derived data sets were validated using ground-based observations from the International Soil Moisture Network (ISMN). The internally calculated dielectric constant product results in significantly more days with valid retrievals than the original soil moisture data products, in particular over arid regions. The dielectric constant product resulted in similar correlations with in situ data as the original soil moisture data product. Together, these findings demonstrate the usefulness of this new dielectric constant product for the hydrological modeling community and climate studies. A case study on the Australian Fitzroy catchment demonstrated that the downscaled data product has a more detailed spatial description of soil moisture, especially during wet and dry conditions with more pronounced dry and wet regions within the catchment. The increased resolution data products could therefore improve runoff predictions and this study demonstrated the potential added value of a transitioning from a spatial resolution of 56 km toward a higher resolution of 11 km. The hydrological implications of these newly developed data records are not only linked to AMSR-E satellite data, but also to the next generation Soil Moisture Active and Passive (SMAP) mission where a 9 km spatial resolution is the target resolution for satellite soil moisture products. The new data products will not replace the current LPRM products, but will be added to the existing array of data products and will become publicly available through our data portals.

spatial↗

Measurement of Acute Changes in Choroid Thickness in Healthy Eyes During Posture Change Using Optical Coherence Tomography

The Visual Impairment and Intracranial Pressure (VIIP) syndrome affects 60% of astronauts returning from long-duration missions and is characterized by structural and functional changes of the eye (3). Upon entry into weightlessness, approximately two liters of fluid translocates from the lower body to the thorax and cephalad regions, potentially contributing to elevated intracranial and intraocular pressures. The choroid is the vasculature that supplies blood flow to the posterior part of the retina and has limited autoregulation. As a consequence these vessels may engorge during a cephalad fluid shift, contributing to structural changes in the retina. The purpose of this experiment was to quantify changes in choroid thickness during a fluid shift. In order to fulfill this objective, it was also necessary to improve the measurement technique for assessing choroid thickness.

Ferguson, Connor R.↗

Operational Transition from the First-Generation Heidelberg Spectralis Optical Coherence Tomography [OCT("OCT1")] to the Second-Generation Heidelberg Spectralis OCT("OCT2")

The Heidelberg Spectralis "OCT2", which recently became commercially available, is going to be implemented at the Johnson Space Center Flight Medicine Clinic and on board the International Space Station. Due to the increased scan rate of the "OCT2", this upgrade will allow for significant reduction in valuable crew testing time and also allow for additional capabilities, like OCT Angiography and Multi-Color Fundus Imaging. Due to the custom scans used to monitor Space Flight-Associated Neuro-ocular Syndrome (SANS) in our crewmembers, an evaluation to assess the impacts of transitioning from "OCT1" to "OCT2" was performed. An engineering assessment (N=1) was performed to identify any potential impacts of maintaining an "OCT1" on board ISS while implementing an "OCT2" in the JSC Clinic. "OCT2" implementation will lag JSC FMC clinical implementation due to the flight certification/manifestation process. The clinical assessment was performed (n=12) to identify any impacts due to the replacement of the "OCT1" with the "OCT2" to the longitudinal OCT data across a crewmember's mission/lifetime. The qualitative results from the engineering and clinical evaluation will be reported, as well as the quantitative assessment of the clinical variables

Mason, S.↗

Probing Large-Scale Coherence Between Spitzer IR and Chandra X-Ray Source-Subtracted Cosmic Backgrounds

We present new measurements of the large-scale clustering component of the cross-power spectra of the source-subtracted Spitzer-IRAC cosmic infrared background and Chandra-ACIS cosmic X-ray background surface brightness fluctuations. Our investigation uses data from the Chandra Deep Field South, Hubble Deep Field North, Extended Groth Strip/AEGIS (All-wavelength Extended Groth Strip International Survey) field, and UDS (Ultra-Deep Survey) / SXDF surveys, comprising 1160 Spitzer hours and approximately 12 megaseconds of Chandra data collected over a total area of 0.3 degrees squared. We report the first (greater than 5 sigma) detection of a cross-power signal on large angular scales greater than 20 arc seconds between [0.5-2] kiloelectronvolts and the 3.6 and 4.5 micron bands, at approximately 5 omega and 6.3 sigma significance, respectively. The correlation with harder X-ray bands is marginally significant. Comparing the new observations with existing models for the contribution of the known unmasked source population at redshift less than 7, we find an excess of about an order of magnitude at 5 sigma confidence. We discuss possible interpretations for the origin of this excess in terms of the contribution from accreting early black holes (BHs), including both direct collapse BHs and primordial BHs, as well as from scattering in the interstellar medium and intra-halo light.

Capelluti, N.↗

Continuous Carrier Optical Phase Optometric Measurement over Coherent Optical Communication Link

An apparatus for measuring a distance between a first and second terminal includes a frame counter for determining a number of data frames traversing a distance between the first terminal 105 and the second terminal, a frame bit counter for determining a number of data clock bits offset between a transmitted data frame and a concurrently received data frame, a data clock phase detector for determining a phase difference between an RF data clock for the transmitted data frame and an RF data clock for the concurrently received data frame, and an optical carrier phase detector for determining a phase difference between an optical carrier used to transmit the transmitted data frame and an optical carrier for the concurrently received data frame. The distance between the first and second terminal is determined from a round trip transit time T between the first and second terminals.

Yang, Guangning↗

Electromagnetic Scattering by Discrete Random Media. IV: Coherent Backscattering

The problem of backscattering of light by a discrete random medium illuminated by an obliquely incident plane electromagnetic wave is considered.The analysis is performed in a linear-polarization basis and includes a complete derivation of the cross reflection matrix for a layer with densely and sparsely distributed particles, the design of an approximate method for computing the ladder and cross reflection matrices in the case of a semi-infinite medium with a sparse distribution of particles, the derivation of the relations between the elements of the ladder and cross reflection matrices in the exact backscattering direction for dense and sparse media, and the development of practical algorithms for solving the underlying integral equations by the method of Picard iterations and the discrete ordinate method. Simulation results for particles with large size parameters are also presented.

Adrian Doicu↗

Development of Buffet Functions using Frequency-Dependent Coherence Factors

Launch vehicle transonic buffet environments produce large fluctuating pressures on the surface of the vehicle. Transonic buffet occurs as a launch vehicle passes through the transonic regime, typically Mach 0.8 to 1.2, where phenomena such as flow separation and shock dynamics produce large fluctuating pressures. The unsteady aerodynamic forces produced by these phenomena can excite both global and local vehicle structural response. The consequences of incorporating poorly characterized buffet forces into the design process can range from inefficient structures that can reduce the vehicle capabilities to undersized structures that, in the worst case scenario, may result in structural failure (Refs. 1, 2, 3). It is thus imperative to appropriately characterize the transonic buffet environment.

buffet↗

Design and fabrication of a coherent array of single-mode optical fibers for the nulling coronagraph

We present the development of a single-mode spatial filter array for the nulling coronagraph application. The development consists of two generations of fiber array designs and a Zygo-interferometer based lens array to fiber array alignment methodology. We discuss the use of large mode field diameter (MFD) fibers to relax fiber placement tolerance of the fiber array. The pros and cons of using the Photonic Crystal Fiber (PCF) for building the array are discussed. The future plan for implementing a 1000-channel class, single-mode spatial filter array is described.

Shao, Mike↗