Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONSULTANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Contam airflow models of three large buildings: Model descriptions and validation

Airflow and pollutant transport models are useful for several reasons, including protection from or response to biological terrorism. In recent years they have been used for deciding how many biological agent samplers are needed in a given building to detect the release of an agent; to figure out where those samplers should be located; to predict the number of people at risk in the event of a release of a given size and location; to devise response strategies in the event of a release; to determine optimal trade-offs between sampler characteristics (such as detection limit and response time); and so on. For some of these purposes it is necessary to model a specific building of interest: if you are trying to determine optimal sampling locations, you must have a model of your building and not some different building. But for many purposes generic or 'prototypical' building models would suffice. For example, for determining trade-offs between sampler characteristics, results from one building will carry over other, similar buildings. Prototypical building models are also useful for comparing or testing different algorithms or computational pproaches: different researchers can use the same models, thus allowing direct comparison of results in a way that is not otherwise possible. This document discusses prototypical building models developed by the Airflow and Pollutant Transport Group at Lawrence Berkeley National Laboratory. The models are implemented in the Contam v2.4c modeling program, available from the National Institutes for Standards and Technology. We present Contam airflow models of three virtual buildings: a convention center, an airport terminal, and a multi-story office building. All of the models are based to some extent on specific real buildings. Our goal is to produce models that are realistic, in terms of approximate magnitudes, directions, and speeds of airflow and pollutant transport. The three models vary substantially in detail. The airport model is the simplest; the onvention center model is more detailed; and the large office building model is quite complicated. We give several simplified floor plans in this document, to explain basic features of the buildings. The actual models are somewhat more complicated; for instance, spaces that are represented as rectangles in this document sometimes have more complicated shapes in the models. (However, note that the shape of a zone is irrelevant in Contam). Consult the Contam models themselves for detailed floor plans. Each building model is provided with three ventilation conditions, representing mechanical systems in which 20%, 50%, or 80% of the building air is recirculated and the rest is provided from outdoors. Please see the section on 'Use of the models' for important information about issues to consider if you wish to modify the models to provide no mechanical ventilation or eliminate provision of outdoor air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final work plan : phase I investigation of potential contamination at the former CCC/USDA grain storage facility in Montgomery City, Missouri.

From September 1949 until September 1966, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) leased property at the southeastern end of Montgomery City, Missouri, for the operation of a grain storage facility. During this time, commercial grain fumigants containing carbon tetrachloride were commonly used by the CCC/USDA and the private grain storage industry to preserve grain in their facilities. In January 2000, carbon tetrachloride was detected in a soil sample (220 {micro}g/kg) and two soil gas samples (58 {micro}g/m{sup 3} and 550 {micro}g/m{sup 3}) collected at the former CCC/USDA facility, as a result of a pre-CERCLIS site screening investigation (SSI) performed by TN & Associates, Inc., on behalf of the U.S. Environmental Protection Agency (EPA), Region VII (MoDNR 2001). In June 2001, the Missouri Department of Natural Resources (MoDNR) conducted further sampling of the soils and groundwater at the former CCC/USDA facility as part of a preliminary assessment/site inspection (PA/SI). The MoDNR confirmed the presence of carbon tetrachloride (at a maximum identified concentration of 2,810 {micro}g/kg) and chloroform (maximum 82 {micro}g/kg) in the soils and also detected carbon tetrachloride and chloroform (42.2 {micro}g/L and 58.4 {micro}g/L, respectively) in a groundwater sample collected at the former facility (MoDNR 2001). The carbon tetrachloride levels identified in the soils and groundwater are above the default target level (DTL) values established by the MoDNR for this contaminant in soils of all types (79.6 {micro}g/kg) and in groundwater (5.0 {micro}g/L), as outlined in Missouri Risk-Based Corrective Action (MRBCA): Departmental Technical Guidance (MoDNR 2006a). The corresponding MRBCA DTL values for chloroform are 76.6 {micro}g/kg in soils of all types and 80 {micro}g/L in groundwater. Because the observed contamination at Montgomery City might be linked to the past use of carbon tetrachloride-based fumigants at its former grain storage facility, the CCC/USDA will conduct investigations to (1) characterize the source(s), extent, and factors controlling the possible subsurface distribution and movement of carbon tetrachloride at the Montgomery City site and (2) evaluate the health and environmental threats potentially represented by the contamination. This work will be performed in accord with the Intergovernmental Agreement established between the Farm Service Agency of the USDA and the MoDNR, to address carbon tetrachloride contamination potentially associated with a number of former CCC/USDA grain storage facilities in Missouri. The investigations at Montgomery City will be conducted on behalf of the CCC/USDA by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. The site characterization at Montgomery City will take place in phases. This approach is recommended by the CCC/USDA and Argonne, so that information obtained and interpretations developed during each incremental stage of the investigation can be used most effectively to guide subsequent phases of the program. This site-specific Work Plan outlines the specific technical objectives and scope of work proposed for Phase I of the Montgomery City investigation. This Work Plan also includes the community relations plan to be followed throughout the CCC/USDA program at the Montgomery City site. Argonne is developing a Master Work Plan specific to operations in the state of Missouri. In the meantime, Argonne has issued a Provisional Master Work Plan (PMWP; Argonne 2007) that has been reviewed and approved by the MoDNR for current use. The PMWP (Argonne 2007) provides detailed information and guidance on the investigative technologies, analytical methodologies, quality assurance-quality control measures, and general health and safety policies to be employed by Argonne for all investigations at former CCC/USDA grain storage facilities in Missouri. Both the PMWP and this site-specific Work Plan must therefore be consulted for a complete description of the planned Phase I work at the former CCC/USDA facility at Montgomery City.

54 ENVIRONMENTAL SCIENCES↗

Recommended Best Practices for the Characterization of Storage Properties of Hydrogen Storage Materials

These reports, written by H2 Technology Consulting under contract with the National Renewable Energy Laboratory, provides an introduction to and overview of the recommended best practices in making measurements of the hydrogen storage properties of materials. Sections 1-5 (published in February 2012), Section 6 (published in February 2013), and Section 7 (published in January 2016). The goal in developing this report was to create a reference guide of common methodologies and protocols for measuring critical performance properties of advanced hydrogen storage materials and to serve as a resource to the hydrogen storage materials development community to aid in clearly communicating the relevant performance properties of new materials as they are discovered and tested. Section 1: Introduction Section 2: Kinetics Measurements Section 3: Capacity Measurements Section 4: Thermodynamic Measurements Section 5: Cycle-Life Measurements Section 6: Thermal Properties Measurements Section 7: Mechanical Properties Measurements

08 HYDROGEN↗

Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders - Chicago, IL and Devens, MA

TO4 Task 3.1 - K Hovnanian Chicago, IL DOE Challenge Home Program Certified Home Constructed and Verified Specifications DOE Challenge Home Building envelope Ceiling R-49 blown fiberglass, Grade I Walls 2x4 framing @ 16 o.c. with R-13 fiberglass batts, Grade I and 1"" R-5 extruded polystyrene (XPS) insulating sheathing Frame Floors R-38 blown fiberglass, Grade I Basement Walls R-19 fiberglass batts draped full height, Grade I Basement Slab uninsulated Windows Above Grade: ENERGY STAR certified, U=0.29, SHGC=0.28 Basement: Non ENERGY STAR certified, U=0.29, SHGC=0.24 Infiltration 2 ACH 50 Mechanical systems Heat 95% AFUE sealed combustion natural gas furnace in conditioned space Goodman GMH950703BXAF Cooling 13 SEER split system Goodman GSX130301BC DHW AO Smith Vertex 100 0.96 EF natural gas tank water heater in 2nd floor utility closet Hot Water Distribution Redesigned trunk and branch Compliant with EPA WaterSense Efficient Distribution Requirements Ducts Located 100% in conditioned space via floor joists leak free to outside (5% or less) Ventilation Central Fan Integrated Supply (CFIS) ventilation with 6"" insulated outside air duct Fan Controller: Air Cycler FRV, with 6"" motorized damper 50 CFM outside air flow, 33% duty cycle (10 minutes on, 20 minutes off); ASHRAE 62.2-2010 compliance via an exhaust fan - Panasonic FV-08VQ5 WhisperCeiling Rerturn Pathways Active Return at Master Bedroom Transfer Grilles in Secondary Bedrooms Appliances, Lighting, MELs Lights 80% ENERGY STAR certified CFL Appliances ENERGY STAR certified refrigerator, dishwasher, and clothes washer; Natural gas range/oven and clothes dryer" STRUCTURE - Test House Lot 145 - 2013 DOE Challenge Test House Task 3.1 Bolingbrook, IL 60490 House is constructed and is DOE Challenge Verified by Don Nelson, a local rater. The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. To that end, Building Science Corporation (BSC) consulted on the construction of five test houses by three cold climate production builders in three separate U.S. cities. (1) K. Hovnanian Homes, Chicago, Illinois (2) David Weekley Homes, Denver, Colorado (3) Transformations, Inc., Devens, Massachusetts. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations about the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: (1) Adding services to the scope of work for various trades, such as HERS Rater and heating, ventilation, and air conditioning contractor. (2) Increased material costs related to the checklists, especially the U.S. Environmental Protection Agency Indoor airPLUS and WaterSense Efficient Hot Water Distribution requirement. Ceiling - 18" cellulose Walls - 12" open cell spray foam in double stud walls Foundation - R-10 under slab, 3 1/2" closed-cell spray foam at walls Windows - Harvey U=0.20, SHGC=0.22 Infiltration - 1.0 sq in per 100 sq ft Heating - Mini split heat pump, 10.6 HSPF, 23 SEER Cooling - Mini split heat pump, 10.6 HSPF, 23 SEER DHW - 0.97 EF instantaneous propane water heater Ventilation - bathroom exhaust fans as basic option, HRV upgrade option Adams Circle Devens MA 01434 Cavite Street Devens, MA 01434

Array↗

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring.The existing condition was a vented crawlspace with an un-insulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this un-vented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.While the un-vented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

affordable housing↗

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and a significant number of apartments are overheated much of the time. This is often evidenced by open windows on winter days. Controls and distribution are often faulty, and improving them can be more cost effective than replacing boilers. Thermostatic radiator valves (TRVs), which have been in use for many decades, are one potential strategy to combat this problem. They are commonly used in Europe and in other markets such as commercial buildings, but have not been widely accepted by the residential retrofit market in the northeastern United States. Anecdotal evidence suggests that heating systems engineers and contractors have a variety of opinions about their effectiveness, illustrating a lack of consensus on this potentially important energy efficiency measure. A review of the limited available literature revealed that, in one study, heating fuel savings as high as 15% was achieved through TRV retrofits. In this project, the U.S. Department of Energy Building America team, Advanced Residential Integrated Energy Solutions, sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt (Building Energy Optimization software). Radiator and apartment space temperature data were collected and analyzed for two similar apartment units in a building that underwent a one-pipe steam TRV retrofit. Space temperature comparisons were made across the pre- and post-TRV installation heating periods and between rooms equipped with old or new TRVs in an attempt to show the comparative effectiveness of each vintage of TRV. Analyses of the heating fuel utility bills before and after the building-wide TRV installation were conducted to quantify potential savings. The results of the field experiment and utility bill analysis did not show energy savings at either the unit or the building-wide level. The results provided inconclusive answers to the original study questions but provided valuable insight into common steam system imbalance and resident behavior issues that are critical to address in conjunction with TRV retrofits. Specific issues identified included steam distribution imbalance, possible TRV sensor location issues, a persistent window-opening habit, and a failure to optimize the boiler control set points as part of the TRV retrofit. The lack of heating fuel savings underscored the need to include whole steam system commissioning alongside or as a prerequisite to TRVs. Failed air vents and uneven steam main venting are critical to address either in conjunction with or before a TRV installation. Monitoring existing space temperatures before a retrofit strategy is chosen would allow the consultant and building owner to better assess the potential benefits of a whole-building TRV retrofit, selective installation of TRVs in some units, or simply balancing the steam distribution venting. Further gaps in the understanding of underlying processes that allow TRVs to function effectively were also identified and are presented as opportunities for future research.

Array↗

NorthernSTAR 1.5-Story Demonstration House of Cold Climate Solutions for Affordable Housing

This is a NorthernSTAR renovation project for Urban Homeworks incorporating installation of a combination space and water heater, Overcoat insulation retrofit on the roof, and Excavationless foundation insulation retrofit. STRUCTURE - 1401 North 16th Ave Minneapolis, MN 55411 Various groups from the affordable housing industry have consulted with the University of Minnesota's Cold Climate Housing Program to solve persistent energy and health-related problems such as ice dams, high energy bills, and mold/moisture issues-especially in complicated house types such as 1.5-story homes in cold climates. The NorthernSTAR Building America Partnership has completed multiple research projects on high-performance measures applied during renovation of single-family homes that could help the affordable housing industry address performance concerns. This demonstration project is an example of three high-performance measures applied to one house in Minneapolis, Minnesota. The selected vacant home was completely renovated by Urban Homeworks (UHW), which is a nonprofit housing partner, with the intent of selling the home to a low-income family. The renovation included the addition of the three advanced-performance technologies that were applied to the overall scope of the project. Single-family homes in urban areas that are available for renovation by nonprofit developers are often in need of repair. Budgeting has historically focused on improving homes to meet basic housing standards. A rising interest in the long-term impact of homeownership has introduced the need to balance basic needs with home performance. The goal of this demonstration project was to help UHW and other nonprofit developers become familiar with three U.S. Department of Energy Building America performance measures-including the installation processes, impacts, and benefits of each. To maximize efficiency of application and to address budget issues, the NorthernSTAR team worked with UHW to identify ways to use volunteers and construction training programs to install the measures. An open invitation to visit the job site was provided to other nonprofit developers and support teams to encourage dialog about the systems during live installation.

affordable housing↗

Conceptual Interpretation of First and Second Kinds of Errors at Management Mode Selection under Conditions of Its Possible Crisis State

Errors in the selection of management practices at an enterprise confronting the prospect of crisis are considered: specifically, the adoption of standard management during a crisis; or crisis management when no crisis exists. By analogy with classical approaches in probability theory and operational research, such errors are interpreted as errors of the first and second kind. The basic problems arising from such errors are identified, and some measures are proposed for reducing their likelihood. The results should prove useful to managers at industrial enterprises, consulting firms, developers of management systems, and the faculty at universities and staff-training centers.

99 GENERAL AND MISCELLANEOUS↗

PROVISIONAL ADVISORY LEVELS (PALs) FOR ACRYLONITRILE

Application of PAL protocols was performed for acrylonitrile, as experimental data permitted. Human data were limited to inhalation exposures. The animal experimental data set for this chemical was robust for inhalation and oral studies, with the exception of appropriate data for inhalation 30-d, 90-d, and 2-yr PAL 3 values. PAL estimates were approved by the Expert Consultation Panel for Provisional Advisory Levels in October 2007. Oral 24-hr PALs for acrylonitrile are: PAL 1 = 7 mg/L; PAL 2 = 23 mg/L; and PAL 3 = 88 mg/L. Oral 30-d and 90-d PALs are: PAL 1 = 0.35 mg/L; PAL 2 = 7 mg/L; and PAL 3 = 17 mg/L. Oral 2-yr PALs are: PAL 1 = 0.35 mg/L; PAL 2 = 3.5 mg/L; and PAL 3 = 12 mg/L. Acrylonitrile inhalation PAL values for 24 hr exposure are: PAL 1 = 0.17 ppm; PAL 2 = 3.5 ppm; and PAL 3 = 5.1 ppm; the 30-d and 90-d inhalation exposure values are: PAL 1 = 0.15 ppm and PAL 2 = 0.60 ppm. The 2-yr inhalation values are: PAL 1 = 0.014 ppm and PAL 2 = 0.12 ppm. PAL 3 values for 30-d, 90-d, and 2-yr are not recommended due to insufficient data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

PROVISIONAL ADVISORY LEVELS (PALs) FOR HYDROGEN SULFIDE (H2S)

Application of PAL protocols was performed for hydrogen sulfide (H2S) as experimental data permitted. The data base includes human experimental studies, worker exposure evaluations, as well as case studies on acute and repeated exposure. The data base of animal studies is substantial covering multiple species and addressing acute, repeated, and subchronic exposure scenarios. PAL estimates were approved by the Expert Consultation Panel for Provisional Advisory Levels in November 2006. No reliable data were found on oral exposure, making it impractical to estimate PALs for drinking water. Since H2S exists as a gas, partitioning to air is likely to occur with an environmental release. H2S inhalation PAL values for 24 hr exposure are: PAL 1 = 1.2 ppm; PAL 2 = 7.0 ppm; and PAL 3 = 27 ppm; the 30-d and 90-d inhalation exposure values are: PAL 1 = 0.85 ppm and PAL 2 = 3.0 ppm. PAL 3 values for 30-d and 90-d are not recommended due to insufficient data. Long-term data were insufficient to estimate 2-year inhalation PALs.

54 ENVIRONMENTAL SCIENCES↗

PROVISIONAL ADVISORY LEVELS (PALs) FOR PHOSGENE (CG)

The PAL protocol was applied to estimate inhalation exposure limits for phosgene (CG). Data on humans are limited to occupational exposures or accounts from the use of phosgene as a chemical warfare agent in WWI. Animal studies with phosgene show a steep dose-response curve for pulmonary edema and mortality with little species variability in effects. Although immediately upon exposure lacrimation and upper respiratory irritation can occur, the main effect in the target organ, a progressive pulmonary edema, occurs after a latency period of 1-24 hours. PAL estimates were approved by the Expert Consultation Panel for Provisional Advisory Levels in May 2007. Exposure limits for oral exposure to CG are not developed due to insufficient data. PAL estimates for inhalation exposure to CG are presented: The 24-hour PAL values for severity levels 1, 2, and 3 are 0.0017, 0.0033 and 0.022 ppm, respectively. The 30-day PAL values are 0.0006 and 0.0012 ppm for the PAL 1 and 2 values, respectively. These 30-day inhalation values were also accepted as the 90-day and 2-year PAL 1 and 2 values. Data were not available for deriving 30-day, 90-day and 2-year PAL 3 values.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges

The US Environmental Protection Agency (EPA) and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes) readings from mobile and handheld air sensors with the longer duration averages (hours to days) associated with the National Ambient Air Quality Standards (NAAQS) for the criteria pollutants-particulate matter (PM), ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs) where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG) was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs.

54 ENVIRONMENTAL SCIENCES↗

Pandemic, War, and Global Energy Transitions

The COVID-19 pandemic and Russia’s war on Ukraine have impacted the global economy, including the energy sector. The pandemic caused drastic fluctuations in energy demand, oil price shocks, disruptions in energy supply chains, and hampered energy investments, while the war left the world with energy price hikes and energy security challenges. The long-term impacts of these crises on low-carbon energy transitions and mitigation of climate change are still uncertain but are slowly emerging. This paper analyzes the impacts throughout the energy system, including upstream fuel supply, renewable energy investments, demand for energy services, and implications for energy equity, by reviewing recent studies and consulting experts in the field. We find that both crises initially appeared as opportunities for low-carbon energy transitions: the pandemic by showing the extent of lifestyle and behavioral change in a short period and the role of science-based policy advice, and the war by highlighting the need for greater energy diversification and reliance on local, renewable energy sources. However, the early evidence suggests that policymaking worldwide is focused on short-term, seemingly quicker solutions, such as supporting the incumbent energy industry in the post-pandemic era to save the economy and looking for new fossil fuel supply routes for enhancing energy security following the war. As such, the fossil fuel industry may emerge even stronger after these energy crises creating new lock-ins. This implies that the public sentiment against dependency on fossil fuels may end as a lost opportunity to translate into actions toward climate-friendly energy transitions, without ambitious plans for phasing out such fuels altogether. We propose policy recommendations to overcome these challenges toward achieving resilient and sustainable energy systems, mostly driven by energy services.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mapping Benthic Habitat Conditions and Seafloor Deposits using Sediment Profile Imaging and a Semiautomated Image Processing System

Objectives/Scope: Sediment profile imaging (SPI) technology characterizes in situ physical, geochemical, and biological seafloor features. SPI was required by Mexico’s Agency for Safety, Energy, and Environment in 2017 for environmental baseline surveys (EBS) of oil lease blocks in the southern Gulf of Mexico. Because of its ability to provide information on benthic community health and the distribution of very thin (down to the centimeter scale) layers of deposited materials, SPI technology is highly effective for mapping drill cuttings or drilling muds released around wellheads during exploration or production and documenting their ecological impacts. SPI technology has not been widely used in the oil and gas industry for EBS or other monitoring activities. A primary objective of this work is to improve the transparency and consistency of the SPI data generation and data management process. Methods, Procedures, Process: The SPI camera works like an inverted periscope and obtains an undisturbed 21x15-cm cross-sectional image of the upper sediment column. The camera is internally powered and can be deployed rapidly from a standard winch in depths to 4,000 m. Many stations can be sampled in a single day by “pogo-sticking” across a survey area. Sediment grain size, penetration depth, surface boundary roughness, natural and anthropogenic depositional layers, depth of the oxidized surface sediment layer, maximum biogenic mixing depth, and infaunal successional stage can be directly measured at sea or immediately following the cruise. Final SPI data sets can be provided within a few weeks of the survey. Results, Observations, Conclusions: Details on the features measured in SPI images and the underlying interpretive paradigms are presented. To standardize the SPI data generation process, Integral Consulting Inc. has developed 1) a semiautomated image analysis platform, and 2) a SPI data-specific database architecture that allows both numerical and non-numerical metrics to be incorporated into a standard database structure. An integrated, software-based SPI analysis platform has been developed that imports image files and metadata and provides a graphical user interface. The software automatically stores the data, which can then be reviewed for quality assurance, plotted, statistically analyzed, and mapped or exported to other platforms (e.g., Esri ArcGIS©) for further evaluation. Image processing algorithms have been developed using a combination of open-source and commercially available software packages (e.g., MATLAB® and OpenCV) to automatically quantify key parameters. Novel/Additive Information: SPI technology’s underutilization in the oil and gas industry may be in part due to a lack of standardization in the measurement of basic features in SPI images. A primary objective of this work is to develop a streamlined, standardized, and transparent process for generating and managing SPI data.

02 PETROLEUM↗

Gallbladder Volvulus: A Rare Emergent Cause of Acute Cholecystitis, if Untreated, Progresses to Necrosis and Perforation

An 86 year-old woman with a past medical history significant for abdominal hernia and Alzheimer dementia presented to the Emergency Department with a 24 hour history of acute right upper quadrant pain associated with nausea and non-bilious emesis. Physical exam revealed right sided abdominal tenderness with associated mass. All laboratory values were within normal ranges. Both abdominal ultrasound and computed tomography of the abdomen/pelvis revealed a large distended gallbladder with wall thickening and gallstones. Based on presentation and radiologic findings, the emergency general surgery service was consulted for suspected acute cholecystitis. The patient was then admitted for intravenous antibiotics and scheduled for laparoscopic cholecystectomy the following day. Intra-operative findings revealed volvulus with acute necrosis of the entire gallbladder. The gallbladder had a long pedunculated cystic duct and artery that was detorsed before proceeding with resection. Postoperatively, the patient did well and was discharged a few days later tolerating a regular diet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An automated integrated web-based smart tool for open stope design

The Stability Graph is a widely used tool for the design of open stopes in underground mining. Many users of the Stability Graph still apply this design method manually. Although the manual approach has benefits, using multiple graphs and stability number computation charts for each stope surface is time-consuming, even for the experienced mining engineer. Current practice in the use of the method also limits data sharing. This paper presents a StopeSoft web-based tool for open stope stability prediction that is developed on the basis of the Stability Graph method and is available at openstope.com. StopeSoft incorporates flexibility in terms of Stability Graph options and incorporates additional critical factors often overlooked. As a web-based tool, StopeSoft encourages and makes data sharing possible globally, focused on expanding the database and improving the current limitations of the Stability Graph to provide practical, reliable solutions for mining engineers, consultants, and academics. The StopeSoft automated process facilitates the process of open stope stability prediction, saving time and minimizing potential human errors. Statistical treatment of the data accounts for the variability of input parameters to emphasize the probabilistic nature of the Stability Graph method. The probabilistic interpretation of the stability states of stope surfaces eliminates the false feeling of absolute stope performance based on its location on the Stability Graph , as implied by the deterministic approach.

58 GEOSCIENCES↗

CMIP7 data request: Earth system priorities and opportunities

This paper presents a comprehensive overview of the Coupled Model Intercomparison Project Phase 7 (CMIP7) request for data pertaining to Earth systems science, and provides justification for the resources needed to produce this data. Topics within the CMIP7 Earth System (CMIP7-ES) theme centre around tracking of flows of energy, carbon, water and other fluxes across domains, and constraining feedbacks between these cycles and the climate system. These topics are summarized in this paper as scientific “opportunities” describing specific model intercomparison experiments and use cases for next-generation Earth System Model (ESM) output. These opportunities were submitted by modelling groups and scientific consortia following an extended public consultation process. Contained within each opportunity are requests for groups of Climate & Forecasting (CF) variables, which are bundled into variable groups representing all data required to address the opportunities' needs. Novel opportunities in CMIP7 compared with previous phases will include running `emissions-driven' simulations that integrate carbon emissions and removal scenarios with updated representations of the global carbon cycle, expanded variable groups needed to model marine trophic interactions and biogeochemistry, and data needed to understand the risk of global tipping points, among others. The production of these variables will close key gaps and uncertainties identified during previous rounds of CMIP, and support the 7th Intergovernmental Panel on Climate Change Assessment Report (AR7). We argue that CMIP7-ES data will be broadly used by scientific, policy, governmental, industry, and other communities that rely on climate model projections for research and decision making. As an author group we also reflect on the evolution of the CMIP7-ES data request as a part of a deliberative process in support of the global CMIP program.

54 ENVIRONMENTAL SCIENCES↗

Rapid Evaluation Framework for the CMIP7 Assessment Fast Track

As Earth system models (ESMs) grow in complexity and in volume of output data, there is an increasing need for rapid, comprehensive evaluation of their scientific performance. The upcoming Assessment Fast Track for the Seventh Phase of the Coupled Model Intercomparison Project (CMIP7) will require expeditious response for model analyses designed to inform and drive integrated Earth system assessments. To meet this challenge, the Rapid Evaluation Framework (REF), a community-driven platform for benchmarking and performance assessment of ESMs, was designed and developed. The initial implementation of the REF, constructed to meet the near-term needs of the CMIP7 Assessment Fast Track, builds upon four disparate community evaluation and benchmarking tools that are coupled together using the Coordinated Model Evaluation Capabilities (CMEC) framework. The REF runs within a containerized workflow for portability and reproducibility and is aimed at generating and organizing diagnostics covering a variety of model variables. The REF leverages well documented observational datasets to provide assessments of model fidelity across a collection of diagnostics. All diagnostics were identified and selected with community involvement and consultation. Operational integration with the Earth System Grid Federation (ESGF) will permit automated execution of the REF for selected diagnostics as soon as model output data are published on ESGF by the originating modeling centers. The REF is designed to be portable across a range of current computational platforms to facilitate use by modeling centers for assessing the evolution of model versions or gauging the relative performance of CMIP simulations before being published on ESGF. When integrated into production simulation workflows, results from the REF provide immediate quantitative feedback that allows model developers and scientists to quickly identify model biases and performance issues. After the REF is released to the community, its subsequent development and support will be prioritized by an international consortium of scientists and engineers, enabling a broader impact across Earth science disciplines. For instance, the REF will facilitate improvements to models and will enhance confidence in model projections through process-based selection of models based on their performance with respect to observations. Production of reproducible diagnostics and community-based assessments are key features of the REF. Furthermore, providing interoperability with existing evaluation packages assures that contributions from previous community efforts will be available for use in future model intercomparison projects.

Hoffman, Forrest [ORNL] (ORCID:0000000158024134)↗