Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Simulations of stable compact proton beam acceleration from a two-ion-species ultrathin foil

We report stable laser-driven proton beam acceleration from ultrathin foils consisting of two ion species: heavier carbon ions and lighter protons. Multidimensional particle-in-cell simulations show that the radiation pressure leads to very fast and complete spatial separation of the species. The laser pulse does not penetrate the carbon ion layer, avoiding the proton Rayleigh-Taylor (RT)-like instability. Ultimately, the carbon ions are heated and spread extensively in space. In contrast, protons always ride on the front of the carbon ion cloud, forming a compact high quality bunch. We introduce a simple three-interface model to interpret the instability suppression in the proton layer. The model is backed by simulations of various compound foils such as carbon-deuterium and carbon-tritium foils. The effects of the carbon ions' charge state on proton acceleration are also investigated. It is shown that with the decrease of the carbon ion charge state, both the RT-like instability and the Coulomb explosion degrade the energy spectrum of the protons. Finally, full 3D simulations are performed to demonstrate the robustness of the stable two-ion-species regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel compact design of calibration equipment for gas and thermal sensors

A novel design of calibration equipment has been developed for static and dynamic calibrations of gas and thermal sensors. This system is cheap, compact, and easily adjustable, which is also combined with a plasma surface modification source for tailoring the surface of sensors to ensure the sensitivity and selectivity. The main advantage of this equipment is that the operating temperature, bias voltage, types of plasma source (for surface modification), types of feeding gases, and gas flow rate (for calibrations), etc., can be independently controlled. This novel system provides a highly reliable, reproducible, and economical method of calibrations for various gas and thermal sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact Electronic Gamma Source For Radiotherapy

A compact mono-energetic gamma source is being developed to replace the radiological sources used in radiotherapy and other medical instruments. The electronic gamma source utilizes low-energy nuclear reactions to generate gammas in the 0.5 to 1.0 MeV energy range. Independent control of the ion current and energy is achieved by decoupling the RF-driven ion source and pyroelectric crystal-based acceleration systems The ions are accelerated to voltages above 100 keV and bombard a reaction target to produce gammas. Thermal management of the pyroelectric crystal-based accelerator is achieved by convective dielectric fluid flow around the crystal. This approach provides better temperature uniformity in the crystal and higher dielectric strength for suppressing voltage breakdown and enabling faster thermal cycling rates.

43 PARTICLE ACCELERATORS↗

A Permanent-Magnet Microwave Ion Source For A Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x10{sup 11} n/s for D-T and {approx}1x10{sup 10} n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm{sup 2}) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm{sup 2} was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

43 PARTICLE ACCELERATORS↗

A compact electron cyclotron resonance proton source for the Paul Scherrer Institute's proton accelerator facility

A compact electron cyclotron resonance proton source has been developed and installed recently at thePaul Scherrer Institute's high intensity proton accelerator. Operation at the ion source test stand and the accelerator demonstrates a high reliability and stability of the new source. When operated at a 10 - 12 mA net proton current the lifetime of the source exceeds 2000 h. The essential development steps towards the observed performance are described.

43 PARTICLE ACCELERATORS↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Compact Penning Ion Source for Material Studies

Development of ion sources of various sizes has been carried out since a long back. Gaseous ions of different nature are being used in different field of research as well as industrial applications like surface modification, doping, surface etching, sputtering, production of nano size particles and focused ion beam etc. Out of various geometry and operation regime, due to compactness, ruggedness and long life, penning type ion sources are widely used in different field of research and applications. One such type of ion source was developed in our laboratory. Though this source was meant for neutron generation, using deuterium ions, the effectiveness for other purposes was investigated. The discharge characteristic was studied for different gases like, Deuterium, Helium, Nitrogen, Oxygen and Argon. The source being a self extracted type; the extracted ion current from the extraction aperture was measured using one faraday cup. In this paper we have discussed, the discharge characteristic and the extraction ion current for different type of gases.

07 ISOTOPE AND RADIATION SOURCES↗

Electron Strippers for Compact Neutron Generators

The next generation of compact tandem-type DD or DT neutron generators requires a robust electron stripper with high charge exchange efficiency. In this study, stripping foils of various types were tested, and the H{sup -} to H{sup +} conversion efficiency, endurance to the heat load, and durability were investigated in terms of suitability in the tandem-type neutron generator. In the experiments, a H{sup -} beam was accelerated to about 180 keV, passes through a stripping foil, and produces a mixed beam of H{sup -}, H{sup 0}, and H{sup +}. These ions were separated by an electric field, and detected by a movable Faraday cup to determine the conversion efficiency. The experimental results using thin foils of diamond-like carbon, gold, and carbon nano-tubes revealed issues on the robustness. As a new concept, a H{sup -} beam was injected onto a metal surface with an oblique angle, and reflected H{sup +} ions are detected. It was found that the conversion efficiency, H{sup +} fraction in the reflected particles, depends on the surface condition, with the maximum value of about 90%.

43 PARTICLE ACCELERATORS↗

Plasma-enhanced gasification of low-grade coals for compact power plants

A high temperature of a steam torch ensures an efficient gasification of low-grade coals, which is comparable to that of high-grade coals. Therefore, the coal gasification system energized by microwaves can serve as a moderately sized power plant due to its compact and lightweight design. This plasma power plant of low-grade coals would be useful in rural or sparsely populated areas without access to a national power grid.

20 FOSSIL-FUELED POWER PLANTS↗

The compact neutron spectrometer at ASDEX Upgrade

The first neutron spectrometer of ASDEX Upgrade (AUG) was installed in November 2008. It is a compact neutron spectrometer (CNS) based on a BC501A liquid scintillating detector, which can simultaneously measure 2.45-MeV and 14-MeV neutrons emitted from deuterium (D) plasmas and {gamma} radiation. The scintillating detector is coupled to a digital pulse shape discrimination data acquisition (DPSD) system capable of count rates up to 10{sup 6} s{sup -1}. The DPSD system can operate in acquisition and processing mode. With the latter n-{gamma} discrimination is performed off-line based on the two-gate method. The paper describes the tests of the CNS and its installation at AUG. The neutron emission from the D plasma measured during a discharge with high auxiliary heating power was used to validate the CNS performance. The study of the optimal settings for the DPSD data processing to maximize the n-{gamma} discrimination capability of the CNS is reported. The CNS measured both 2.45-MeV and 14-MeV neutrons emitted in AUG D plasmas with a maximum count rate of 5.4 x10{sup 5} s{sup -1} (>10 times higher than similar spectrometers previously achieved) with an efficiency of 9.3 x 10{sup -10} events per AUG neutron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of compact linear accelerator in KBSI

The compact linear accelerator using a 28 GHz ECRIS is under construction in KBSI, South Korea. The main capability of this facility is the production of fast neurons for the neutron radiography. The designing of a superconducting magnet, microwave transmission system, beam extraction, and plasma chamber of ECRIS were finished. The nominal axial design fields of the magnets are 3.6 T at injection and 2.2 T at extraction; the nominal radial design field strength at the plasma chamber wall is 2.1 T. We already installed 10 kW, 28 GHz gyrotron, and tested a microwave power from gyrotron using a dummy load. The current status will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Technical use of compact micro-onde devices

Due to the very small size of a COMIC (Compact MIcrowave and Coaxial) device [P. Sortais, T. Lamy, J. Medard, J. Angot, L. Latrasse, and T. Thuillier, Rev. Sci. Instrum. 81, 02B31 (2010)] it is possible to install such plasma or ion source inside very different technical environments. New applications of such a device are presented, mainly for industrial applications. We have now designed ion sources for highly focused ion beam devices, ion beam machining ion guns, or thin film deposition machines. We will mainly present new capabilities opened by the use of a multi-beam system for thin film deposition based on sputtering by medium energy ion beams. With the new concept of multi-beam sputtering (MBS), it is possible to open new possibilities concerning the ion beam sputtering (IBS) technology, especially for large size deposition of high uniformity thin films. By the use of multi-spots of evaporation, each one corresponding to an independent tuning of an individual COMIC ion source, it will be very easy to co-evaporate different components.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact microwave ion source for industrial applications

A 2.45 GHz microwave ion source for ion implanters has many good properties for industrial application, such as easy maintenance and long lifetime, and it should be compact for budget and space. But, it has a dc current supply for the solenoid and a rf generator for plasma generation. Usually, they are located on high voltage platform because they are electrically connected with beam extraction power supply. Using permanent magnet solenoid and multi-layer dc break, high voltage deck and high voltage isolation transformer can be eliminated, and the dose rate on targets can be controlled by pulse duty control with semiconductor high voltage switch. Because the beam optics does not change, beam transfer components, such as focusing elements and beam shutter, can be eliminated. It has shown the good performances in budget and space for industrial applications of ion beams.

43 PARTICLE ACCELERATORS↗

A very low energy compact electron beam ion trap for spectroscopic research in Shanghai

In this paper, a new compact low energy electron beam ion trap, SH-PermEBIT, is reported. This electron beam ion trap (EBIT) can operate in the electron energy range of 60-5000 eV, with a current density of up to 100 A/cm{sup 2}. The low energy limit of this machine sets the record among the reported works so far. The magnetic field in the central drift tube region of this EBIT is around 0.5 T, produced by permanent magnets and soft iron. The design of this EBIT allows adjustment of the electron gun's axial position in the fringe field of the central magnetic field. This turned out to be very important for optimizing the magnetic field in the region of the electron gun and particularly important for low electron beam energy operation, since the magnetic field strength is not tunable with permanent magnets. In this work, transmission of the electron beam as well as the upper limit of the electron beam width under several conditions are measured. Spectral results from test operation of this EBIT at the electron energies of 60, 315, 2800, and 4100 eV are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration of a compact high efficient relativistic magnetron with directly axial radiation

A compact relativistic magnetron with axial microwave radiation is experimentally investigated. Under the modified magnetic field distribution, only connecting a special horn antenna in the axial direction, the relativistic magnetron can stably radiate high power and high efficiency microwaves. The total length of the device is {approx}0.3 m, and the volume is {approx}0.014m{sup 3}. In such working condition that the applied voltage is 539 kV and the magnetic field is {approx}0.38 T, the output microwave power is {approx}1.24 GW. Correspondingly, the total efficiency is about 34.1%. The radiating frequency is 2.35GHz, which is in agreement with the {pi} mode frequency of the theoretical expectation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact filament-discharge multi-cusp H{sup -} ion source

A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H{sup -} ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H{sup -} ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA/25 keV H{sup -} beam with an emittance of 0.3 {pi} mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.

43 PARTICLE ACCELERATORS↗

Compact cryogenic source of periodic hydrogen and argon droplet beams for relativistic laser-plasma generation

We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art high-power lasers in which a precise synchronization between the laser pulses and the droplets is mandatory. We show this by irradiating argon droplets with multi-terawatt pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tuneable ultra-compact high-power, ultra-short pulsed, bright gamma-ray source based on bremsstrahlung radiation from laser-plasma accelerated electrons

The laser driven plasma wakefield accelerator is a very compact source of high energy electrons. When the quasi-monoenergetic beam from these accelerators passes through dense material, high energy bremsstrahlung photons are emitted in a collimated beam with high flux. We show how a source based on this emission process can produce more than 10{sup 9} photons per pulse with a mean energy of 10 MeV. We present experimental results that show the feasibility of this method of producing high energy photons and compare the experimental results with GEANT4 Montecarlo simulations, which also give the scaling required to evaluate its suitability as method to produce radioisotopes via photo-nuclear reactions or for imaging applications.

07 ISOTOPE AND RADIATION SOURCES↗