Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPSULES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Robustness Studies of Ignition Targets for the National Ignition Facility in Two Dimensions

Inertial confinement fusion capsules are critically dependent on the integrity of their hot spots to ignite. At the time of ignition, only a certain fractional perturbation of the nominally spherical hot spot boundary can be tolerated and the capsule still achieve ignition. The degree to which the expected hot spot perturbation in any given capsule design is less than this maximum tolerable perturbation is a measure of the ignition margin or robustness of that design. Moreover, since there will inevitably be uncertainties in the initial character and implosion dynamics of any given capsule, all of which can contribute to the eventual hot spot perturbation, quantifying the robustness of that capsule against a range of parameter variations is an important consideration in the capsule design. Here, the robustness of the 300 eV indirect drive target design for the National Ignition Facility [J. D. Lindl, et al., Phys. Plasmas 11, 339 (2004)] is studied in the parameter space of inner ice roughness, implosion velocity, and capsule scale. A suite of two thousand two-dimensional simulations, run with the radiation hydrodynamics code Lasnex, is used as the data base for the study. For each scale, an ignition region in the two remaining variables is identified and the ignition cliff is mapped. In accordance with the theoretical arguments of Levedahl and Lindl [Nucl. Fusion 37, 165 (1997)] and Kishony and Shvarts [Phys. Plasmas 8, 4925 (2001)], the location of this cliff is fitted to a power law of the capsule implosion velocity and scale. It is found that the cliff can be quite well represented in this power law form, and, using this scaling law, an assessment of the overall (one- and two-dimensional) ignition margin of the design can be made. The effect on the ignition margin of an increase or decrease in the density of the target fill gas is also assessed.

42 ENGINEERING↗

Anomalous yield reduction in direct-drive deuterium/tritium implosions due to {sup 3}He addition

Glass capsules were imploded in direct drive on the OMEGA laser [Boehly et al., Opt. Commun. 133, 495 (1997)] to look for anomalous degradation in deuterium/tritium (DT) yield and changes in reaction history with {sup 3}He addition. Such anomalies have previously been reported for D/{sup 3}He plasmas but had not yet been investigated for DT/{sup 3}He. Anomalies such as these provide fertile ground for furthering our physics understanding of inertial confinement fusion implosions and capsule performance. Anomalous degradation in the compression component of yield was observed, consistent with the ''factor of 2'' degradation previously reported by Massachusetts Institute of Technology (MIT) at a 50%{sup 3}He atom fraction in D{sub 2} using plastic capsules [Rygg, Phys. Plasmas 13, 052702 (2006)]. However, clean calculations (i.e., no fuel-shell mixing) predict the shock component of yield quite well, contrary to the result reported by MIT but consistent with Los Alamos National Laboratory results in D{sub 2}/{sup 3}He[Wilson et al., J. Phys.: Conf. Ser. 112, 022015 (2008)]. X-ray imaging suggests less-than-predicted compression of capsules containing {sup 3}He. Leading candidate explanations are poorly understood equation of state for gas mixtures and unanticipated particle pressure variation with increasing {sup 3}He addition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct-drive cryogenic-target implosion experiments on SGIII prototype laser facility

Directly driven cryogenic target implosion experiments are performed on the SGIII prototype laser facility. X-ray pinhole images reveal frozen condensation on the sealing film. The influence of the condensation on the delivery of laser energy to the capsule surface is then quantified experimentally. It is found that, with a carefully chosen pre-pulse duration, the influence can be reduced, and the neutron yield is increased by an order of magnitude. Subsequently, the cryogenic layered capsule and cryogenic gas-filled capsule are imploded using 6.5-kJ laser energy. The implosion performance is characterized by the neutron yield, the 2D self-emission images of the in-flight shell, and the primary proton spectrum. The neutron yield is 2 × 10{sup 7} for the gas-filled capsule and 2.8 × 10{sup 7} for the layered capsule. The 2D self-emission images of the in-flight shell exhibit significant implosion asymmetry. The energy downshift of the proton spectrum is used to infer the areal density. For the gas-filled capsule, the spectrum is downshifted by 0.1 MeV, yielding an areal density of 1–3 mg/cm{sup 2}. For the layered capsule, the spectrum is downshifted by 0.5 MeV, yielding an areal density of 4–6 mg/cm{sup 2}. Improving the implosion symmetry would help to further increase the areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling a Hypothetical {sup 170}Tm Source for Brachytherapy Applications

Purpose: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical {sup 170}Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons. Methods: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of {sup 170}Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical {sup 170}Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation. Results: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (<1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively. Conclusions: A {sup 170}Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of {sup 170}Tm as a brachytherapy source presents notable challenges.

07 ISOTOPE AND RADIATION SOURCES↗

AGR-1 Irradiation Test Final As-Run Report, Rev. 3

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-3/4 Irradiation Test Predictions using PARFUME

PARFUME, a fuel performance modeling code used for high temperature gas reactors, was used to model the AGR-3/4 irradiation test using as-run physics and thermal hydraulics data. The AGR-3/4 test is the combined third and fourth planned irradiations of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The AGR-3/4 test train consists of twelve separate and independently controlled and monitored capsules. Each capsule contains four compacts filled with both uranium oxycarbide (UCO) unaltered “driver” fuel particles and UCO designed-to-fail (DTF) fuel particles. The DTF fraction was specified to be 1×10-2. This report documents the calculations performed to predict failure probability of TRISO-coated fuel particles during the AGR-3/4 experiment. In addition, this report documents the calculated source term from both the driver fuel and DTF particles. The calculations include the modeling of the AGR-3/4 irradiation that occurred from December 2011 to April 2014 in the Advanced Test Reactor (ATR) over a total of ten ATR cycles including seven normal cycles, one low power cycle, one unplanned outage cycle, and one Power Axial Locator Mechanism cycle. Results show that failure probabilities are predicted to be low, resulting in zero fuel particle failures per capsule. The primary fuel particle failure mechanism occurred as a result of localized stresses induced by the calculated IPyC cracking. Assuming 1,872 driver fuel particles per compact, failure probability calculated by PARFUME leads to no predicted particle failure in the AGR-3/4 driver fuel. In addition, the release fraction of fission products Ag, Cs, and Sr were calculated to vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 7 reaching up to 56% for the driver fuel and 100% for the DTF fuel. The release fraction of the other two fission products, Cs and Sr, are much smaller and in most cases less than 1% for the driver fuel. The notable exception occurs in Capsule 7 where the release fraction for Cs and Sr reach up to 0.73% and 2.4%, respectively, for the driver fuel. For the DTF fuel in Capsule 7, the release fraction for Cs and Sr are estimated to be 100% and 5%, respectively.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Packed and fluidized bed absorber modeling for carbon capture with micro-encapsulated sodium carbonate solution

Micro-Encapsulated CO 2 Sorbents (MECS) are a promising technology for post-combustion carbon capture because they enable slow-reacting solvents like carbonate solution to compete with traditional amine solvents. Before scaling up MECS for pilot testing, modeling is needed to design a MECS absorber and quantify its size and energy penalty. To that end, a multi-scale model for MECS- that ranges from a single capsule to a 500 MWe power plant absorber- is developed and presented here in this paper. First, the individual capsule model is developed and fitted to experimental CO 2 absorption data collected on a 0.1 g sample of capsules filled with sodium carbonate solution. This capsule model is then validated against data collected on a 25 g batch of capsules exposed to flue gas conditions in a fluidized column. This model is then scaled up to represent two absorber designs: a multi-stage, counter-flow fluidized bed and a hollow, cylindrical packed bed with radial gas flow. These two absorber bed models are first optimized for a 1 MWe pilot-scale absorber, and then optimized for a 500 MWe coal plant. This model predicts absorbers of similar dimensions and smaller energy penalties than previously modeled absorbers filled with amine solvent capsules. Furthermore, it is demonstrated here that a few reasonable improvements to capsule design would result in absorber sizes and energy penalties lower than those of a benchmark amine solvent tower. These results demonstrate that micro-encapsulated carbonate solution can compete with faster-acting amine solvents for post-combustion carbon capture.

20 FOSSIL-FUELED POWER PLANTS↗

Results of the AGR-5/6/7 UCO TRISO fuel irradiation test in the Advanced Test Reactor

AGR-5/6/7 was the last in a series of irradiation experiments sponsored by the U.S. Department of Energy in support of the development and qualification of TRISO coated particle fuel for use in a high-temperature gas-cooled reactor. This experiment was conducted to verify the performance of the reference-design TRISO-coated low-enriched UCO fuel for modular high-temperature gas-cooled reactor normal operating conditions and to explore fuel performance at temperatures substantially beyond those typical of normal operation. A total of 194 UCO fuel compacts in five capsules were irradiated in the Advanced Test Reactor for 360.9 effective full-power days, achieving final burnup ranging from 5.66% to 15.26% fissions per initial heavy metal atom and fast neutron fluence ranging from 1.62 × 10 25 to 5.55 × 10 25 n/m 2 (E > 0.18 MeV). Calculated time-averaged fuel temperatures ranged from 467 °C to 1432 °C, with a peak fuel temperature of 1536 °C. During the first five irradiation cycles (∼180 effective full-power days), 85m Kr fission gas release-rate-to-birth-rate ratios were 10 −7 –10 −6 , indicating no particle failures. Near the end of the sixth cycle, a substantial number of in-pile particle failures occurred in Capsule 1. The fission gas release from this capsule impacted the readings from the other four capsules and led to unreliable fission gas release measurements for all capsules during the last four cycles. A preliminary post-irradiation examination of Capsule 1 fuel and internal components revealed the in-pile particle failures resulted from operational issues with the capsule, not subpar performance of the fuel particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Designing mechano-responsive microcapsules that undergo self-propelled motion.

Biological cells are capable of sensing mechanical cues and responding to these signals by undergoing morphological changes and directed motion. A significant challenge is creating cell-like objects that can translate mechanical stimuli into analogous behavior. Herein, we use computational modeling to design a simple mechanosensitive 'cell' that responds to mechanical deformation through a shape change that allows it to undergo self-sustained, directed movement. Our cellular object is formed from a nanoparticle-filled microcapsule that is located on an adhesive substrate in solution. In response to a locally applied force, the deformed capsule releases nanoparticles that bind to the surface and dynamically create adhesion gradients. Due to the self-generated gradients, the capsule moves autonomously from regions of less adhesion to greater adhesion. During the capsule's motion, new nanoparticles are released that both sustain and propagate the adhesion gradients and thus, the capsule sustains autonomous movement along its path (until it is depleted of nanoparticles). The self-sustained motion occurs only if the permeability of the capsule's shell depends on mechanical deformation. We isolate critical parameters that control the dynamic behavior of this mechano-responsive capsule. Our findings can facilitate the fabrication of devices that are powered by the autonomous movement of microscopic synthetic cells. Additionally, the capsules could serve as sensors for mechanical strain, indicating the presence of strain fields by their spontaneous motion and release of nanoparticles; the latter behavior could be exploited in the fabrication of self-healing materials.

59 BASIC BIOLOGICAL SCIENCES↗

Water-stable direct air capture of CO 2 with microcapsules of task-specific ionic liquid and their electrothermal regeneration

Microcapsules of the task specific ionic liquid (TSIL) 1-ethyl-3-methylimidazolium 2-cyanopyrrolide [EMIM][2CNpyr] with composite polydimethylsiloxane (PDMS) shells were fabricated for use in CO 2 direct air capture (DAC) conditions. The TSIL was encapsulated using an oil-in-oil emulsion as a templating procedure through two different approaches. In the first approach, a PDMS-polyurea (PU) shell was constructed by interfacial polymerization, while in the second approach, a graphene oxide (GO)-PDMS shell was constructed by cross-linking GO sheets. The composition and structure of both capsule types were fully characterized, and their CO 2 DAC performance was evaluated by gravimetric and breakthrough analysis. Both capsules exhibited competitive capacities, with the PDMS-PU capsules and the GO-PDMS capsules reaching 0.75 mol kg −1 and 0.66 mol kg −1 , respectively. We further demonstrate that both capsule systems can be regenerated with complementary electrothermal methods. Microwave (MW) regeneration was used for the PDMS-PU capsules, effectively releasing absorbed CO 2 in less than an hour. Owing to the electrical conductivity of GO, GO-PDMS capsules were regenerated via radio frequency heating (RF). This work highlights the importance and opportunity of tuning solid–liquid composite performance for advanced applications, including direct air capture of carbon dioxide.

Al-Mahbobi, Luma [Texas A&M University, College St↗

Effects of thermal conductivity of liquid layer in NIF wetted foam experiments

Numerical simulation of inertial confinement fusion (ICF) capsule implosion experiments needs many plasma parameters corresponding to different materials and their mixtures for a wide range of densities and temperatures. Thermal conduction plays a crucial role in coupling energy to the capsule, is one of the primary mechanisms of energy loss during implosion, has a significant effect on hot-spot formation, and impacts the growth of hydrodynamic instabilities. The determination of accurate thermal conductivity of ICF relevant materials is thus important for understanding capsule performance. Analytic models such as Spitzer or Lee-More models have been extensively used in simulations due to the limited availability of experimental data. First principles calculations have shown that these analytic models tend to underestimate electron thermal conductivity in the warm dense plasma regime for ICF related materials. Here, we numerically investigate the effects of different models for the electron heat conductivity coefficients, including both analytic and Quantum Molecular Dynamics (QMD)-based models, for mixed materials in ICF. We also investigate the impact of how conductivities are calculated in mixed cells from constituent material conductivities. We apply this to the modeling of recent wetted foam capsule implosions on the National Ignition Facility, in which a foam layer on the inside of the capsule is wetted with deuterium-tritium (DT) liquid. We have found that electron heat conductivity affects the initial hot-spot formation and its evolution. Strikingly, we observe that capsule performance is more sensitive to the method used to mix material conductivities in mixed cells than how individual material conductivity coefficients are calculated. Furthermore, we have found that using the first principles QMD-based conductivity model along with an appropriate model for mixed-cell conductivities yields better agreement with experimental results compared to the established modeling strategies. We also investigate the impact of mixed material conductivity modeling on the process of ablator material mixing with DT ice in a plastic ice-layer capsule. In our simulations, the heat conductivity model affects the calculated mix widths at the fuel-ablator interface, particularly near the tent scar. Additional mixing between the DT fuel and the ablator in turn increases the implosion adiabat, which results in a lower hot-spot pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corroborating Channel Gap Probe Measurements with an Optical Profiler

As nuclear fuel plates get irradiated, the fuel plate thickness changes. How the fuel plate changes with irradiation is a significant parameter that is important to predict fuel performance in new fuel systems. The channel gap probe is used to indirectly infer changes in fuel plate thicknesses by measuring the gaps between the fuel plates contained within capsules after each irradiation cycle. Independent measures should be used to corroborate salient measurements such as changes in fuel thickness which help ascertain fuel performance. The use of traditional metrological tools to validate channel gap probe measurements are not practical due to the capsule geometry. The accuracy of the channel gap probe inserted within a capsule has not been verified. Since there is no “gold” standard measurement to verify CGP measurements, an optical profilometer has been used to corroborate the CGP measurements. The optical profilometer has been able to corroborate the capsules channel gaps to within 0.04 mm for both ends of the capsule. The optical profiler is also able to measure plate thickness that matched micrometer measurements to within 0.025 mm. In conclusion, the profilometer corroborated the CGP measurements but a discrepancy was found at one end of the capsule for the Inside Capsule Width from the profilometer when compared to a caliper measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AGR-1 Irradiation Test Final As-Run Report, Rev 2

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 ?1025 n/m2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10-7 with only one capsule significantly exceeding this value. A maximum R/B of around 2?10-7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-2 Disassembly Report

The Next Generation Nuclear Plant (NGNP) Graphite Research and Development (R&D) Program is currently measuring irradiated material properties for predicting the behavior and operating performance of new nuclear graphite grades available for use within the cores of new very high temperature reactor designs. The Advanced Graphite Creep (AGC) experiment, consisting of six irradiation capsules, will generate irradiated graphite performance data for NGNP reactor operating conditions. The AGC experiment is designed to determine the changes to specific material properties such as thermal diffusivity, thermal expansion, elastic modulus, mechanical strength, irradiation induced dimensional change rate, and irradiation creep for a wide variety of nuclear grade graphite types over a range of high temperature, and moderate doses. A series of six capsules containing graphite test specimens will be used to expose graphite test samples to a dose range from 1 to 7 dpa at three different temperatures (600, 900, and 1200°C) as described in the Graphite Technology Development Plan. Since irradiation induced creep within graphite components is considered critical to determining the operational life of the graphite core, some of the samples will also be exposed to an applied load to determine the creep rate for each graphite type under both temperature and neutron flux. All six AGC capsules in the experiment will be irradiated in the Advanced Test Reactor (ATR). AGC-1 and AGC-2 will be irradiated in the south flux trap and AGC-3–AGC-6 will be irradiated in the east flux trap. The change in flux traps is due to NGNP irradiation priorities requiring the AGC experiment to be moved to accommodate Fuel irradiation experiments. After irradiation, all six AGC capsules will be cooled in the ATR Canal, sized for shipment, and shipped to the Materials and Fuels Complex (MFC) where the capsule will be disassembled in the Hot Fuel Examination Facility (HFEF). During disassembly, the metallic capsule will be machined open and the individual samples removed from the interior graphite body containing the samples. Samples removed from the capsule will be loaded in a shipping drum and shipped to the Idaho National Laboratory (INL) Research Center (IRC) for initial post-irradiation examination (PIE) and storage for any future testing at the newly completed Carbon Characterization Laboratory (CCL). All work was performed under an ASME NQA-1-2008;1a-2009 compliant quality assurance program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-1 Irradiation Test Final As-Run Report

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-1 Specimen Post Irradiation Data Report

Here we report the results of the Post Irradiation Examination (PIE) of the creep, control, and piggyback specimens from the irradiation creep capsule AGC-1. This is the first (prototype) of a series of six capsules planned as part of the Advanced Graphite Creep (AGC) experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphites. The data reported include: specimen dimensions and hence the dimensional change upon irradiation (a comparison of these data for specimen matched pairs will yield the creep strain); mass and volume, hence density; elastic constants (Young’s modulus, shear modulus and Poisson’s ratio) from ultrasonic time of flight (TOF) and velocity measurements; Young’s modulus from the fundamental frequency of vibration; electrical resistivity; and thermal expansion from 100-550°C (hence coefficient of thermal expansion). Over 8500 individual physical measurement have been made and the data are reduced and reported here. The AGC-1 capsule was irradiated in the Advanced Test Reactor (ATR) at INL at approximately 700°C and to a peak dose of 7 dpa (displacements per atom). The specimen’s final dose, temperature and stress conditions have been reported by INL and are also tabulated here. Additionally the analysis of the SiC temperature monitors is reported. These temperature monitors were located along the center of the AGC-1 capsule and provide an independent assessment of the capsules final irradiation temperature. While all the PIE testing is reported (with the exception of the glued-end tensile strength specimens) additional analysis of the AGC data will be required to allow: 1. Improved fits to the existing models of graphite irradiation induced creep strain. 2. With the eventual advent of temperature dependency data from the additional AGC series of capsules, and microstructural data from piggy back specimens in AGC capsules, the development of new and improved models for the development of irradiation induced creep strain in graphite are anticipated. 3. An Investigation into the effects of creep strain on the physical properties of irradiated graphite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hayabusa Re-Entry: Trajectory Analysis and Observation Mission Design

On June 13th, 2010, the Hayabusa sample return capsule successfully re-entered Earth s atmosphere over the Woomera Prohibited Area in southern Australia in its quest to return fragments from the asteroid 1998 SF36 Itokawa . The sample return capsule entered at a super-orbital velocity of 12.04 km/sec (inertial), making it the second fastest human-made object to traverse the atmosphere. The NASA DC-8 airborne observatory was utilized as an instrument platform to record the luminous portion of the sample return capsule re-entry (~60 sec) with a variety of on-board spectroscopic imaging instruments. The predicted sample return capsule s entry state information at ~200 km altitude was propagated through the atmosphere to generate aerothermodynamic and trajectory data used for initial observation flight path design and planning. The DC- 8 flight path was designed by considering safety, optimal sample return capsule viewing geometry and aircraft capabilities in concert with key aerothermodynamic events along the predicted trajectory. Subsequent entry state vector updates provided by the Deep Space Network team at NASA s Jet Propulsion Laboratory were analyzed after the planned trajectory correction maneuvers to further refine the DC-8 observation flight path. Primary and alternate observation flight paths were generated during the mission planning phase which required coordination with Australian authorities for pre-mission approval. The final observation flight path was chosen based upon trade-offs between optimal viewing requirements, ground based observer locations (to facilitate post-flight trajectory reconstruction), predicted weather in the Woomera Prohibited Area and constraints imposed by flight path filing deadlines. To facilitate sample return capsule tracking by the instrument operators, a series of two racetrack flight path patterns were performed prior to the observation leg so the instruments could be pointed towards the region in the star background where the sample return capsule was expected to become visible. An overview of the design methodologies and trade-offs used in the Hayabusa re-entry observation campaign are presented.

Cassell, Alan M.↗

Small Specimen Data from a High Temperature HFIR Irradiation Experiment

The HTV capsule is a High Flux Isotope Reactor (HFIR) target-rod capsule designed to operate at very high temperatures. The graphite containing section of the capsule (in core) is approximately 18 inches (457.2 mm) long and is separated into eight temperature zones. The specimen diameters within each zone are set to achieve the desired gas gap and hence design temperature (900 C, 1200 C or 1500 C). The capsule has five zones containing 0.400 inch (10.16 mm) diameter specimens, two zones containing 0.350 inch (8.89 mm) diameter specimens and one zone containing 0.300 inch (7.62 mm) diameter specimens. The zones have been distributed within the experiment to optimize the gamma heating from the HFIR core as well as minimize the axial heat flow in the capsule. Consequently, there are two 900 C zones, three 1200 C zones, and three 1500 C zones within the HTV capsule. Each zone contains nine specimens 0.210 0.002 inches (5.334 mm) in length. The capsule will be irradiated to a peak dose of 3.17 displacements per atom. The HTV specimens include samples of the following graphite grades: SGL Carbon s NBG-17 and NBG-18, GrafTech s PCEA, Toyo Tanso s IG-110, Mersen s 2114 and the reference grade H-451 (SGL Carbon). As part of the pre-irradiation program the specimens were characterized using ASTM Standards C559 for bulk density, and ASTM C769 for approximate Young s modulus from the sonic velocity. The probe frequency used for the determination of time of flight of the ultrasonic signal was 2.25 MHz. Marked volume (specimen diameter) effects were noted for both bulk density (increased with increasing specimen volume or diameter) and Dynamic Young s modulus (decreased with increasing specimen volume or diameter). These trends are extended by adding the property vs. diameter data for unirradiated AGC-1 creep specimens (nominally 12.5 mm-diameter x 25.4 mm-length). The relatively large reduction in Dynamic Young s Modulus was surprising given the trend for increasing density with increasing volume. The graphite-filler particle size was noted to be influential in the volume dependency data, with finer grained graphites showing the least specimen volume/diameter effect. Here the volume dependency trends are discussed in terms of the graphite s filler-particle size and texture.

graphite↗