Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Digital Beam Deflectors Based Partly on Liquid Crystals

A digital beam deflector based partly on liquid crystals has been demonstrated as a prototype of a class of optical beam-steering devices that contain no mechanical actuators or solid moving parts. Such beam-steering devices could be useful in a variety of applications, including free-space optical communications, switching in fiber-optic communications, general optical switching, and optical scanning. Liquid crystals are of special interest as active materials in nonmechanical beam steerers and deflectors because of their structural flexibility, low operating voltages, and the relatively low costs of fabrication of devices that contain them.

Pouch, John J.↗

Features of the Spectral Characteristics of Narrow-Band Optical Filters with Oblique Incidence of the Radiation Beam

The performance of narrow-band optical filters on the basis of frustrated total internal reflection was analyzed taking into account the Gaussian distribution of the angle of radiation incidence. The spectral characteristics of these optical filters are modelled with and without divergence of the incident beam. It is shown that, when measuring the spectral characteristics of optical filters, the divergence of the incident radiation beam should not be greater than a certain limit value that does not exceed several angular minutes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Splitter Introduces Little Aberration

Placing beam splitter inside existing lens minimizes aberrations. Six channel beam splitter has optical paths of lengths equal to distances traveled by rays. Lens element cemented to each of exit faces of beam splitter is optically concentric with element cemented to entrance face and with center of curvature of monocentric optical system. Beam splitter makes it possible to form separate image in each wavelength channel of interest.

Evans, N. L., Jr.↗

Trapping two types of particles using a double-ring-shaped radially polarized beam

An optical-trap method based on the illumination of a double-ring-shaped radially polarized beam (R-TEM{sub 11}*) is proposed. The numerical results based on the vector diffraction theory show that a highly focused R-TEM{sub 11}* beam not only can produce a bright spot but also can form an optical cage in the focal region by changing the truncation parameter {beta}, defined as the ratio of the radius of the aperture to the waist of the beam. The radiation forces acting on Rayleigh particles are calculated by using the Rayleigh scattering theory. The bright spot generated by the R-TEM{sub 11}* beam with a {beta} value close to 2 can three-dimensionally trap a particle with a refractive index larger than that of the ambient. An optical cage or three-dimensional dark spot generated by the R-TEM{sub 11}* beam with a {beta} value close to 1.3 can three-dimensionally trap a particle with refractive index smaller than that of the ambient. Because the adjustment of the truncation parameter can be actualized by simply changing the radius of a circular aperture inserted in the front of the lens, only one optical-trap system in the present method can be used to three-dimensionally trap two types of particles with different refractive indices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design of an achromatic and uncoupled medical gantry for radiation therapy

We are presenting the layout and the optics of a beam line to be used as a medical gantry in radiation therapy. The optical properties of the gantry's beam line are such as to make the beam line achromatic and uncoupled. These two properties make the beam spot size, which is delivered and focused by the gantry, on the tumor of the patient, independent of the angular orientation of the gantry. In this paper we present the layout of the magnetic elements of the gantry, and also present the theoretical basis for the optics design of such a gantry. A medical gantry, as it is used in the radiation treatment of cancer patients, is the last part of the beam optical system, of the accelerator complex, which delivers and focuses the beam on the tumor. The curved line shown in figure 1 is a schematic diagram of a gantry which can rotate about a horizontal axis. The particle beam (green arrow in fig. 1) enters the gantry, and is guided by the gantry on the tumor (red spot in fig. 1). As the gantry rotates about the axis shown in figure 1, the beam exiting the gantry always lies on a plane normal to the rotation axis at the point of the icocenter. Thus the gantry facilitates the ability of the beam delivery system, to deliver the beam at the tumor, which is placed at the icocenter, from any angle on this vertical plane, which is normal to the rotation angle of the gantry as stated earlier. The gantry consists of dipoles and quadrupoles elements whose median symmetry plane lies on a plane which contains the rotation axis of the gantry. In this paper we define this plane as the 'plane of the gantry'. As the beam is transported along the axis of rotation of the gantry and before it enters the gantry, it is focused by 'normal' quadrupoles and experiences no linear beam coupling. Subsequently the beam enters the gantry, and is transported by the gantry to the delivery point which is the tumor. The transported beam at the tumor is still linearly uncoupled as long as the plane of the gantry lies either, on the horizontal, or the vertical plane. In these two orientations of the gantry the dipoles and the quadrupoles are 'normal' therefore the linear R-transport-matrix appears linearly uncoupled. As the gantry rotates about this horizontal axis, to irradiate the tumor at a different angle, the linear beam coupling is unavoidable since the coordinate system of the gantry's quadrupoles is rotated with respect to the coordinate system of the quadrupoles at the entrance of the gantry which are located along the axis of rotation. As a result, in this rotated coordinate system, the beam will be linearly coupled as it is transported by the gantry to the tumor and the beam size at the location of the tumor will vary in size depending on the orientation of the gantry. In this paper we present a method which makes the beam transport R-matrix linearly uncoupled, achromatic and independent of the orientation angle of the gantry as is proven in the following section.

43 PARTICLE ACCELERATORS↗

Electron Beam Induced Luminescence of SiO2 Optical Coatings

Optical coatings of disordered thin film SiO,/SiO, samples undergoing electron beam bombardment exhibited a cathodoluminescence effect. Measurements were made of the absolute illuminance and emission spectra as functions of incident electron energy (0.2 keV to 30 keV). flux (approx. 0.1 nA/sq cm to > 100 nA/sq cm) and power (<50 nW/sq cm to > 3mW/sq cm) for coatings (approx.60 nm to approx.200 nm thick) on reflective metal substrates over a range of sample temperatures (approx.40 K to approx.400 K) and emission wavelengths (approx.260 nm to approx.5000 nm). Illuminance reached a plateau saturation intensity I(sub sat) approx. 10(exp -4)W/sq cm. scaling as [I(sub mc)/(I + I(sub mc)/I(sub sat)] as incident power I(sub mc) approached I(sub sat). Well below I(sub sat), illuminance scaled linearly with incident power for lower-energy non-penetrating radiation that deposited all of its energy in the dielectric film. At higher incident energies (> 1-5 keV) electrons penetrate the dielectric, depositing only a fraction of their energy in the dielectric film, where deposited energy scales as the ratio of film thickness to penetration range. Since electron range exhibits a peak below approx. 1 keV, the illuminance decreased with increasing energy for penetrating radiation. The temperature dependence of the illuminance. in general, increased with decreasing temperature. Changes in apparent color with temperature were also observed. Four bands in the UV/VIS/NIR range from 300 nm to 1000 nm were observed in spectral measurements; no significant luminescence was detected in a range from approx. 1000 nm to approx. 5000 nm. These different bands either increased or decreased in intensity and shifted slightly in energy with decreasing temperature. Our measurements are explained in terms of simple disordered band theory models based on atomic-scale stochastic transport of electrons in highly disordered insulating materials. The theoretical models provide a fundamental basis for understanding the dependence of cathodoluminescence on irradiation time, incident flux and energy. and sample thickness and temperature. The observed luminescence occurs when an incident high energy electron excites a valence band electron into the conduction band. Following the excitation. a complex series of transitions take place between the extended conduction states and the long-lived localized trapped states (or chromophores) associated with structural or compositional defects in the dielectric materials. Thc transport equations and models of thc spatial and energy distribution of the trapped states below the mobility edge, their occupancy, and transitions provide microscopic scale insights into this macroscopic phenomenon. Our observations and theoretical models are also compared with similar previous room temperature studies of similar SiO2 films.

Dennison, J. R.↗

Method and apparatus of wide-angle optical beamsteering from a nanoantenna phased array

An optical beam-steering apparatus is provided. The apparatus includes one or more optical waveguides and at least one row of metallic nanoantenna elements overlying and electromagnetically coupled to a respective waveguide. In each such row, individual nanoantenna elements are spaced apart along an optical propagation axis of the waveguide so that there is an optical propagation phase delay between successive pairs of nanoantenna elements along the row. The apparatus also includes a respective single electric heating element in thermal contact with each of the waveguides. Each heating element is arranged to heat, substantially uniformly, at least that portion of its waveguide that directly underlies the corresponding row of nanoantenna elements.

47 OTHER INSTRUMENTATION↗

SIM testbed 3 real-time control software

SIM System Testbed 3 (STB3) features three optical interferometers sharing a common baseline, as a dynamic representation of the SIM instrument. An artificial star feeding the interferometers is installed on a separate optics bench. All three interferometers use photons captured by avalanche photo diodes (APDs) to measure the position and quality of fringes, and additional pointing precision is achieved by fast steering mirrors (FSMs) that keep the star images centered on the beam combining optics using a CCD camera. Each interferometer uses internal metrology to measure changes in its optical pathlength. External metrology beams measure changes in the baseline vector. This system acquires and tracks white light fringes with one interferometer, while the other two acquire and track laser light fringes representing the bright guide stars that will be used by SIM. The white light source represents a dim star that cannot supply enough photons for the Science interferometer to lock onto fringes in closed-loop mode; instead it operates open-loop, using pathlength corrections fed to it from the two guide interferometers and the external metrology subsystem to reject disturbances and maintain the fringes. This tracking mode is known as Pathlength Feed Forward (PFF). The precise real-time behavior required to achieve this result is implemented by a complex set of interacting software control loops. This paper describes how these loops take advantage of the benefits of the RTC Core architecture, and how they work together to accomplish STB3's objectives.

interferometry↗

Linear Transformation of Electromagnetic Wave Beams of the Electron-Cyclotron Range in Toroidal Magnetic Configurations

The field structure of quasi-optical wave beams tunneled through the evanescence region in the vicinity of the plasma cutoff in a nonuniform magnetoactive plasma is analyzed. This problem is traditionally associated with the process of linear transformation of ordinary and extraordinary waves. An approximate analytical solution is constructed for a rather general magnetic configuration applicable to spherical tokamaks, optimized stellarators, and other magnetic confinement systems with a constant plasma density on magnetic surfaces. A general technique for calculating the transformation coefficient of a finite-aperture wave beam is proposed, and the physical conditions required for the most efficient transformation are analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Parameters of High Energy Ion Microprobe Systems Comprised of Lafayette Lenses

High energy optimal ion microprobes comprised of new compact magnetic quadrupole lenses (Lafayette Quadrupole Lens) are numerically investigated. The smallest beam spot size and appropriate radii of object and divergence slits are presented for different emittances and compared with the corresponding parameters of the Oxford triplet for the same total length. The parameters of the calculated microprobes include demagnification, the magnetic field in the lenses and the coefficients of spherical and chromatic aberrations for several quadrupole system configurations including the doublet, the Lafayette symmetric triplet, the Russian magnetic quadruplets and sextuplets.

43 PARTICLE ACCELERATORS↗

Detection of a coherent population trapping resonance in a beam of {sup 87}Rb atoms by the Ramsey method

Formation of a coherent population trapping (CPT) resonance is studied in the interaction of a beam of {sup 87}Rb atoms with two spatially separated domains of the dichromatic field. Various resonance excitation schemes are compared depending on the choice of operation transitions and type of the polarisation scheme. In the case of a single-velocity atomic beam, the dependence of the CPT resonance profile is studied as a function of principal parameters of the system: beam velocity, distance between optical fields, laser beam dimensions and intensities, and applied permanent magnetic field. Influence of the atomic beam angular divergence and residual beam velocity spread on the resonance quality parameter is estimated. (atomic beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New optical technology for low mass intelligent trigger and readout.

New optical devices offer the potential for reductions in mass, power, and cost of data paths for on-board trigger and readout of tracking detectors. We give examples of optical modulators, MEMS beam steering devices, and optical coupling. We also present results on radiation hardness of materials as well as different approaches to using optics in triggering.

99 GENERAL AND MISCELLANEOUS↗

Resonant two- or three-photon ionization of noble-gas atoms captured by time-resolved photoelectron momentum spectroscopy

In this work, we present an all-electron, ab initio calculation of time-resolved photoelectron momentum distributions (PMDs) induced by resonant two-color, two- or three-photon ionization of helium and neon atoms, as recently measured by Villeneuve et al. [Science 356, 1150 (2017)] using a femtosecond infrared (IR) laser pulse and an attosecond pulse train (APT) produced with high harmonic generation as an extreme ultraviolet (XUV) photon source. In contrast to a monochromatic XUV pulse commonly used at the free-electron laser facilities, an APT is broadband and ultrashort (<1 fs), so that it could induce nonresonant one-photon transitions above ionization threshold as well as a resonantly excited state. They may interfere with each other upon subsequent absorption or emission of an IR photon, so that the resultant PMD loses clear orbital symmetry. Our time-dependent density functional calculation demonstrates that the selection of a particular excited state in the time-resolved PMD is nevertheless possible if energy and timing of an APT are adjusted properly.

74 ATOMIC AND MOLECULAR PHYSICS↗

Near-Threshold Photoemission from Graphene-Coated Cu(110)

In this article, the brightness of electron beams emitted from photocathode sources plays a critical role in determining the performance of x-ray free-electron lasers and ultrafast electron-diffraction applications. In order to achieve the maximum brightness, the electrons need to be emitted from a photocathode with the lowest-possible mean transverse energy (MTE). Recent investigations have shown that capping a Cu(110) photocathode with a monolayer of graphene can protect the quantum efficiency (QE) from long-term exposure to varying vacuum conditions. However, there have been no studies that investigate the effects that a monolayer of graphene has on the MTE. Here, we report on measurements of a graphene-coated Cu(110) single crystal near the photoemission threshold for room and liquid-nitrogen temperatures. At room temperature, a minimum MTE of 25 meV is measured at 295 nm. At liquid-nitrogen temperatures, a minimum MTE of 9 meV is measured at the photoemission threshold of 290 nm.

36 MATERIALS SCIENCE↗

Integrated microwave acousto-optic frequency shifter on thin-film lithium niobate

Electrically driven acousto-optic devices that provide beam deflection and optical frequency shifting have broad applications from pulse synthesis to heterodyne detection. Commercially available acousto-optic modulators are based on bulk materials and consume Watts of radio frequency power. Here, we demonstrate an integrated 3-GHz acousto-optic frequency shifter on thin-film lithium niobate, featuring a carrier suppression over 30 dB. Further, we demonstrate a gigahertz-spaced optical frequency comb featuring more than 200 lines over a 0.6-THz optical bandwidth by recirculating the light in an active frequency shifting loop. Our integrated acousto-optic platform leads to the development of on-chip optical routing, isolation, and microwave signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High temperature measurement of water vapor absorption

An investigation was undertaken to measure the absorption coefficient, at a wavelength of 10.6 microns, for mixtures of water vapor and a diluent gas at high temperature and pressure. The experimental concept was to create the desired conditions of temperature and pressure in a laser absorption wave, similar to that which would be created in a laser propulsion system. A simplified numerical model was developed to predict the characteristics of the absorption wave and to estimate the laser intensity threshold for initiation. A non-intrusive method for temperature measurement utilizing optical laser-beam deflection (OLD) and optical spark breakdown produced by an excimer laser, was thoroughly investigated and found suitable for the non-equilibrium conditions expected in the wave. Experiments were performed to verify the temperature measurement technique, to screen possible materials for surface initiation of the laser absorption wave and to attempt to initiate an absorption wave using the 1.5 kW carbon dioxide laser. The OLD technique was proven for air and for argon, but spark breakdown could not be produced in helium. It was not possible to initiate a laser absorption wave in mixtures of water and helium or water and argon using the 1.5 kW laser, a result which was consistent with the model prediction.

Keefer, Dennis↗

Video sensor with range measurement capability

A video sensor device is provided which incorporates a rangefinder function. The device includes a single video camera and a fixed laser spaced a predetermined distance from the camera for, when activated, producing a laser beam. A diffractive optic element divides the beam so that multiple light spots are produced on a target object. A processor calculates the range to the object based on the known spacing and angles determined from the light spots on the video images produced by the camera.

Briscoe, Jeri M.↗