Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Alignment of NASA’s Human System Risks with Technological Capability Gaps to Enable Integrated Research and Technology Development Strategic Planning

BACKGROUND: Radiation, reduced gravity, distance from earth, isolation and confinement, and habitation within artificially created and controlled life support environments are hazards that present risk to human space explorers. NASA’s Human System Risk Board (HSRB) maintains a set of twenty-nine different Human System Risks with subject matter experts from across the agency providing regular updates to the estimated likelihood and consequence associated with each risk. The Human Research Program (HRP) has historically used these risk classifications as a primary basis for identifying and prioritizing human research investments aimed at characterizing and/or mitigating the respective human system risks. In many cases, technology development is required to mature and validate risk mitigation strategies, however, NASA’s primary technology development programs have not typically used Human System Risks as a basis for strategic planning. A primary function of the Environmental Control and Life Support Systems (ECLSS) – Crew Health and Performance (CHP) System Capability Leadership Team (SCLT) is to continually identify, review, and update technological capability gaps and to establish and oversee multiyear strategic roadmaps aimed at guiding NASA’s technology development priorities in these areas. These roadmaps are intended to be agency-wide and independent of any program, directorate, or other organization within NASA. DESCRIPTION: The SCLT and HRP collaborated to establish a set of Human System Capability Gaps, which establish a formal linkage between the capability gaps used to prioritize investments across much of NASA, and the Human System Risks that are primarily used to inform and prioritize human research. This set of twenty-eight gaps was developed by subject matter experts, and each gap mapped to the primary associated Human System Risks. The gaps and risk mapping were then reviewed and approved via the HSRB, thereby formally aligning the research-focused Human System Risks with the technology-focused capability gaps. DISCUSSION: This effort has enabled development of integrated roadmaps and budget coordination with research and technology development activities that are formally linked to agency-recognized capability gaps and Human System Risks. Close and ongoing coordination between the SCLT, HRP, Mars Campaign Office, and the Health & Medical Technical Authority (HMTA) is essential to ensure alignment and prioritization of CHP-related research and technology development to enable NASA’s future exploration missions.

Andrew F J Abercromby↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

3-dimensional imaging at nanometer resolutions

An apparatus and method for enabling precise, 3-dimensional, photoactivation localization microscopy (PALM) using selective, two-photon activation of fluorophores in a single z-slice of a sample in cooperation with time-gated imaging for reducing the background radiation from other image planes to levels suitable for single-molecule detection and spatial location, are described.

Werner, James H↗

Q and A with Nobelist George Smoot - 2009 BCCP Cosmology Workshop

July 2009: What happens when dark matter and anti-dark mattter collide? If you were in a gravity free environment, what would happen to time? At the annual Cosmology Workshop at Lawrence Berkeley Lab, Nobelist George Smoot answers these questions and more from high school students and teachers. Dr. Smoot was co-awarded the 2006 Nobel Prize in Physics for the discovery of the blackbody form and anisotropy of the cosmic microwave background radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Progress Toward Luminescence-Based VAATE Turbine Blade And Vane Temperature Measurement

Progress towards fielding luminescence-based temperature measurements for the Versatile Affordable Advanced Turbine Engine (VAATE) program is described. The near term programmatic objective is to monitor turbine vane temperatures and health by luminescence from a rare-earth doped thermal barrier coating (TBC), or from a thermographic phosphor layer coated onto a TBC. The first goal is to establish the temperature measurement capability to 1300 C with 1 percent uncertainty in a test engine. An eventual goal is to address rotating turbine blades in an F135 engine. The project consists of four phases, of which the first two have been completed and are described in this paper. The first phase involved laser heating of a 2.54-cm-diameter test sample, coated with a TBC and a thermographic phosphor layer, to produce a thermal gradient across the TBC layer similar to that expected in a turbine engine. Phosphor temperatures correlated well with those measured by long wavelength pyrometry. In the second phase, 10x10- cm coupons were exposed to a jet fuel flame at a burner rig facility. The thermographic phosphor/TBC combination survived the aggressive flame and high exhaust gas velocity, even though the metal substrate melted. Reliable temperature measurements were made up to about 1400 C using YAG:Dy as the thermographic phosphor. In addition, temperature measurements using YAG:Tm showed very desirable background radiation suppression.

Fluorescence thermometry↗

Neutron detection using Poisson distribution comparison independent of count rate based on correlation signals

Embodiments are directed to comparison-based methods of conditionally assessing the excess in correlation of an unknown neutron count measurement compared to the correlation present in a data defined as background, and to providing a technical definition of excess correlation intended to properly handle the measured excess correlation. The degree of correlation between an unknown source and background can be used to prevent masking of neutron count data for the source by background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm Development for Targeted Isotopics, RSLA-002-17, Year 1 of 3

This presentation emphasizes a data-driven method for utilizing machine learning approaches to solve the problem of isotopic identification and create new machine learning algorithms. The presentation suggests that, by using multiple libraries and software packages to train over much larger quantities of data than have been used in the past, predictive models can not only accurately identify isotopes, but can also provide additional information about the radiation background.

algorithm development, machine learning↗

VERIFICATION OF TRISO FUEL BURNUP USING MACHINE LEARNING ALGORITHMS

Pebble Bed Reactors are fueled with fuel pebbles that are circulated multiple times through the reactor vessel before discharge. During the normal operation of a PBR, ejected pebbles are returned to the reactor or discharged depending on the fuel burnup and physical condition of the pebbles. The burnup measurement is usually based on detected radiation signatures of fission products accumulated in the pebble fuel over burnup. Previous research has shown that height of photopeaks of fission products, such as 134Cs, 137Cs, 154Eu, etc., can be used independently or in combination to infer or predict the level of burnup in the fuel. However, it remains challenging to measure such complex sources due to self-shielding effects, strong radiation background and intervening materials. Another operational challenge is the required high throughput of burnup measurement, which necessitates limited measurement time and thus impacts quality of measured gamma-ray spectra. Hence, advanced spectral analysis methods are needed to analyze the noisy gamma spectra and predict the burnup values. We propose to use machine learning (ML) method to interpret gamma-ray spectra and predict the burnup values of the pebbles. ML has achieved widespread success and adoption across a few domains that require pattern recognition and analysis in varied data types. In this work, we apply three proven ML approaches - multilayer perceptrons, convolutional neural networks, and transformers - to the task of predicting fuel burnup from measured gamma spectra, and compile a dataset of simulated spectra for training and validation of the ML models. In this paper, we will discuss the network architecture of these three ML approaches and compare the performance of the simplest of these (MLP) to a standard linear regression.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as ``dark counts'': dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on the electron-hole pair creation energy and Fano factor below 150 eV from Compton scattering in a Skipper-CCD

Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) have achieved sub-electron read-out noise and are an important technology to probe neutrino and light dark matter interactions. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, producing events that can mimic a dark matter or neutrino signal. We present a measurement of the Compton spectrum using a Skipper-CCD and a $^{241}$Am source. With these data, we measure the electron-hole pair-creation energy to be $\left(3.71 \pm 0.08\right)$ eV at 130 K in the energy range between 99.3 eV and 150 eV. By measuring the widths of the steps at 99.3 eV and 150 eV in the Compton spectrum, we introduce a novel technique to measure the Fano factor, setting an upper limit of 0.31 at 90% C.L. These results prove the potential of Skipper-CCDs to characterize the Compton spectrum and to measure precisely the Fano factor and electron-hole pair creation energy below 150 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

RF Studies at Fermilab MuCool Test Area

The accelerating gradient in a RF cavity is limited by many factors such as the surface material properties, RF frequency, the external magnetic field and the gas pressure inside the cavity. In the MuCool Program, RF cavities are studied with the aim of understanding these basic mechanisms and improving their maximum stable accelerating gradient. These cavities are being developed for muon ionization cooling channel for a Neutrino Factory or Muon Collider. We report studies using the 805 MHz and 201 MHz RF cavities in the MuCool Test Area (MTA) at Fermilab. New results include data from buttons of different materials mounted in the 805 MHz cavity, study of the accelerating gradient in the 201 MHz cavity and X-ray background radiation from the cavities due to Bremsstrahlung. The 201 MHz cavity has been shown to be stable at 19 MV/m at zero magnetic field, well in excess of its 16 MV/m design gradient. We will also discuss results from the 201 MHz cavity study in magnetic field and introduce the test of E × B effects with the 805 MHz box cavity.

43 PARTICLE ACCELERATORS↗

Evaluation of Neutron Flux on the Surface of a PWR Dry Storage Cask - 17574

Since the construction of a dry storage facility for spent nuclear fuel is expected in Korea, several methods have been studied for assuring the safety of pressurized-water reactor (PWR) spent fuels in dry storage casks. Existing evaluation methods are mostly based on detection technology of gamma-rays. However, the gamma-ray detection methods have high uncertainties due to background radiation. Therefore, we developed an evaluation method for the spent nuclear fuel monitoring based on neutron detection. In this study, we evaluated neutron flux on the surface of a PWR dry storage cask using computational simulation. Neutron release rate and energy spectra from a Westinghouse (WH) 17x17 type spent fuel with 10 years cooling time were calculated using ORIGEN-ARP code. MCNP code was used to simulate geometry and material properties of the spent fuel assemblies and casks. Neutron flux after 10 years of cooling time of the spent fuels was calculated on the surface of top, side, and bottom of the casks. The metal cask and the concrete cask, called as KORAD-21 casks which newly developed by Korea Radioactive Waste Agency (KORAD), were selected for this study. As a result, for the metal cask, average neutron flux were 4.79x10{sup 2} neutrons/cm{sup 2} sec, 5.29x10{sup 2} neutrons/cm{sup 2} sec, and 1.47x10{sup 3} neutrons/cm{sup 2} sec on the surface of top, side, and bottom of the cask, respectively. For the concrete cask, average neutron flux on the surface of top, side and bottom of the casks were 5.07x10{sup 1} neutrons/cm{sup 2} sec, 1.18x10{sup 1} neutrons/cm{sup 2} sec, and 1.46x10{sup 3} neutrons/cm{sup 2} sec, respectively. The study results can be applied to evaluate characteristics of PWR spent fuels and the neutron flux of dry storage cask. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photonuclear Production of Radioxenon for Air Samples

Radioxenon plays an important role in ensuring compliance with the Comprehensive Nuclear-Test-Ban Treaty due to its ability to be transported through the atmosphere, as well as the fact that the half-lives of its isotopes provide a window long enough to be detected but not long enough that it could become background radiation. This allows it to be correlated with specific events that indicate the testing of nuclear weapons. Idaho National Laboratory supports this mission by providing spiked air samples for monitoring stations to enable instrument calibration and ensure measurement accuracy. We tested a photonuclear method of producing one of the main isotopes of radioxenon, Xe-135. We also tested the separation of Xe-135 from the parent isotope Xe-136 using the method of kinematic recoil. Aluminum coils were placed in quartz ampoules filled with enriched Xe-136 and were irradiated by a bremsstrahlung beam with an endpoint energy of 21 MeV. The results showed that we were not only successful in producing Xe-135 but also that the Xe-135 was deposited into the coil allowing it to be removed from the Xe-136 gas. The coil and the Xe-135 can then be chemically separated. At the time of counting the coil, it was calculated that there was about 18 Bq of activity from Xe-135 remaining in the coil. Future work includes determining the optimal material and geometry of the catcher to maximize the amount of Xe-135 captured.

07 ISOTOPE AND RADIATION SOURCES↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Optical properties of Argonne/KICP TES bolometers for CMB polarimetry.

We present optical data on prototype polarization sensitive Argonne/KICP detectors fabricated at Argonne National Labs which are designed to be installed on the South Pole Telescope and used to measure the polarization of the Cosmic Microwave Background radiation. The detectors are Mo/Au transition edge sensors (TES) suspended on silicon nitride, with radiation coupled to the TES using a gold bar absorber. Two stacked detectors with bars in orthogonal directions will be used to measure both polarizations. We discuss measurements of the optical bandpass, time constants and cross-polarization of the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Q&A with Nobelist George Smoot - 2009 BCCP Cosmology Workshop

July 2009: What happens when dark matter and anti-dark mattter collide? If you were in a gravity free environment, what would happen to time? At the annual Cosmology Workshop at Lawrence Berkeley Lab, Nobelist George Smoot answers these questions and more from high school students and teachers. Dr. Smoot was co-awarded the 2006 Nobel Prize in Physics for the discovery of the blackbody form and anisotropy of the cosmic microwave background radiation.

dark matter, George Smoot↗

Modeling Radiation Detection Using a Mixed-Effects Statistical Model for Background Variation

In this paper, we consider radiation source localization in an urban environment as an inverse problem and use Bayesian parameter estimation techniques to infer the source location and intensity. Since parameter estimation generally requires a large number of model evaluations, we employ a simplified photon transport model, as in a 2017 paper by Stefanescu, et al., to reduce computational requirements. However, the model in the 2017 paper does not account for the physical reality that background radiation varies with position within an urban locale. We incorporate statistical mixed-effects modeling into the simplified transport equation from the Stefanescu, et al. paper to reflect individual variation among the background radiation measurements at multiple detector locations. With our new model, we use a Bayesian DRAM-within-Gibbs technique, which incorporates the Delayed Rejection Adaptive Metropolis (DRAM) algorithm, to estimate the mixed-effects parameters. We note that without adequate prior information, we were unable to simultaneously estimate the set of parameters corresponding to the source intensity, source location, and individual background radiation counts. By calibrating the background in the absence of a source, we obtained narrow prior distributions, which permitted us to jointly infer the source intensity and location and the background radiation distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗