Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Mesoscale Cellular Convection Detection and Classification Using Convolutional Neural Networks: Insights From Long-Term Observations at ARM Eastern North Atlantic Site

Marine boundary layer clouds are crucial in Earth's climate system. They frequently manifest as closed or open cell mesoscale cellular convection (MCC). MCC clouds are challenging to represent accurately in current climate models, highlighting the need for detailed observational data sets and in-depth analyses. This study utilizes over 8 years of observations from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility Eastern North Atlantic (ENA) site at Graciosa Island, Azores, to investigate these clouds. We first apply a convolutional neural network with a U-Net architecture to classify open and closed cells, marking the first application of such an approach for automatically detecting MCC patterns from ground-based radar measurements. This method addresses some observational gaps in satellite data related to low temporal resolution, nighttime challenges, and limited vertical structure capture. The analysis of the MCC cases shows clear differences between closed and open MCCs: Closed MCC clouds are characterized by lower cloud tops and bases, shallower cloud geometrical depth, weaker horizontal wind speeds, stronger atmospheric stability, and a more homogeneous liquid water path than open MCCs. Finally, we demonstrate two potential applications of our radar-based MCC classifications: (a) facilitating the investigation of aerosol-cloud interactions and (b) exploring meteorological factors along with MCC's evolution by integrating satellite imagery and back-trajectory analysis. The identified MCC cases offer a valuable resource for the scientific community to study MCC processes further and improve climate model accuracy.

54 ENVIRONMENTAL SCIENCES↗

A crucial role for dynamic expression of components encoding the negative arm of the circadian clock

In the Neurospora circadian system, the White Collar Complex (WCC) drives expression of the principal circadian negative arm component frequency ( frq ). FRQ interacts with FRH (FRQ-interacting RNA helicase) and CKI, forming a stable complex that represses its own expression by inhibiting WCC. In this study, a genetic screen identified a gene, designated as brd-8 , that encodes a conserved auxiliary subunit of the NuA4 histone acetylation complex. Loss of brd-8 reduces H4 acetylation and RNA polymerase (Pol) II occupancy at frq and other known circadian genes, and leads to a long circadian period, delayed phase, and defective overt circadian output at some temperatures. In addition to strongly associating with the NuA4 histone acetyltransferase complex, BRD-8 is also found complexed with the transcription elongation regulator BYE-1. Expression of brd-8, bye-1, histone h2a.z , and several NuA4 subunits is controlled by the circadian clock, indicating that the molecular clock both regulates the basic chromatin status and is regulated by changes in chromatin. Taken together, our data identify auxiliary elements of the fungal NuA4 complex having homology to mammalian components, which along with conventional NuA4 subunits, are required for timely and dynamic frq expression and thereby a normal and persistent circadian rhythm.

59 BASIC BIOLOGICAL SCIENCES↗

Single nucleotide variants drive evolutionary phage-host arms race in anaerobic carbon dioxide-converting microbiome

Microbial bioconversions are shaped by environmental perturbations and the adaptation of resident microbiomes. Prokaryotes coexist with bacteriophages, yet their coevolutionary trajectories remain underexplored. Here, we investigate the effects of a cultivation vessel leak on an anaerobic consortium performing carbon dioxide reduction. Using time-series shotgun metagenomic sequencing, we reconstruct microbial and viral genomes to track community shifts. We further apply single-nucleotide variant profiling and CRISPR array analysis to monitor viral microdiversity and host defense mechanisms. After bioaugmentation restores bioconversion efficiency, the consortium undergoes pronounced restructuring, with new dominant taxa emerging from the rare biosphere. We identify patterns consistent with phage predation selectively removing certain species, while others exhibit resilience to infection. This shift aligns with a widespread viral outbreak and a transient increased frequency of single nucleotide variants in bacterial CRISPR–Cas defense genes. Expansion of CRISPR spacers further supports that CRISPR-mediated processes influence microbial resilience. Concurrently, phages infecting resilient hosts exhibited adaptive evolution, marked by high genetic heterogeneity. Selective pressure varies across their genomes, targeting infectivity genes and protospacer-adjacent motifs. These findings highlight a dynamic evolutionary arms race driven by the selection of beneficial genetic variants, providing a mechanistic framework for multi-omics investigations, and informing biotechnological applications, including phage-based microbiome manipulation.

Ghiotto, G↗

The positron arm of a plasma-based linear collider

Plasma-based acceleration of electrons has produced high-energy beams at high accelerating gradients with a narrow energy spread and high efficiency both in experiments and simulations. Furthermore, it is now being considered as a complementary approach to the use of radiofrequency cavities in next-generation lepton accelerators. However, compared with electrons, plasma-based positron acceleration is at the present time much less advanced. Although high-gradient positron acceleration in a plasma has been achieved, we are one to three orders of magnitude away from delivering the high-quality positron beams needed for a future high-energy linear collider. Here we review the status of plasma-based acceleration of electrons and positrons and discuss the prospects for substantial progress towards developing the positron arm of a plasma-based electron–positron linear collider in the next decade.

Plasma-based accelerators↗

Assisted extraction of the energy level spacings and lever arms in direct current bias measurements of one-dimensional quantum wires, using an image recognition routine

A multiplexer technique is used to individually measure an array of 256 split gates on a single GaAs/AlGaAs heterostructure. This results in the generation of large volumes of data, which requires the development of automated data analysis routines. An algorithm is developed to find the spacing between discrete energy levels, which form due to transverse confinement from the split gate. The lever arm, which relates split gate voltage to energy, is also found from the measured data. This reduces the time spent on the analysis. Comparison with estimates obtained visually shows that the algorithm returns reliable results for subband spacing of split gates measured at 1.4 K. The routine is also used to assess direct current bias spectroscopy measurements at lower temperatures (50 mK). This technique is versatile and can be extended to other types of measurements. For example, it is used to extract the magnetic field at which Zeeman-split 1D subbands cross one another.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

61 RADIATION PROTECTION AND DOSIMETRY↗

Broadband and stable acoustic vortex emitter with multi-arm coiling slits

We present the analytical design and experimental realization of a scheme based on multi-arm coiling slits to generate the stable acoustic vortices in a broadband. The proposed structure is able to spiral the acoustic wave spatially and generate the twisted acoustic vortices with invariant topological charge for a long propagation distance. Compared with conventional methods which require the electronic control of a bulky loudspeaker, this scheme provides an effective and compact solution to generate acoustic vortices with controllable topological charge in the broadband, which offers more initiatives in the demanding applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emittance preservation for the electron arm in a single PWFA-LC stage using quasi-adiabatic plasma density ramp matching sections

Plasma-based acceleration (PBA) is being considered for a next generation linear collider (LC). In some PBA-LC designs for the electron arm, the extreme beam parameters are expected to trigger background ion motion within the witness beam, which can lead to longitudinally varying nonlinear focusing forces and result in an unacceptable emittance growth of the beam. To mitigate this, we propose to use quasi-adiabatic plasma density ramps as matching sections at the entrance and exit of each stage. We match the witness electron beam to the low density plasma entrance, where the beam initially has a large matched spot size so the ion motion effects are relatively small. As the beam propagates in the plasma density upramp, it is quasi-adiabatically focused, and its distribution maintains a non-Gaussian equilibrium distribution in each longitudinal slice throughout the process, even when severe ion collapse has occurred. This only causes small amounts of slice emittance growth. The phase mixing between slices with different betatron frequencies leads to additional projected emittance growth within the acceleration stage. A density downramp at the exit of an acceleration section can eliminate much of the slice and projected emittance growth as the beam and ion motion adiabatically defocuses and decreases, respectively. Simulation results from QuickPIC with Azimuthal Decomposition show that within a single acceleration stage with a 25 GeV energy gain, this concept can limit the projected emittance growth to only ∼2% for a 25 GeV, 100 nm emittance witness beam and ∼20% for a 100 GeV, 100 nm normalized emittance witness beam. The trade-off between the adiabaticity of the plasma density ramp and the initial ion motion at the entrance for a given length of the plasma density ramp is also discussed.

Physics↗

B56$δ$ long-disordered arms form a dynamic PP2A regulation interface coupled with global allostery and Jordan’s syndrome mutations

Intrinsically disordered regions (IDR) and short linear motifs (SLiMs) play pivotal roles in the intricate signaling networks governed by phosphatases and kinases. B56δ (encoded by PPP2R5D) is a regulatory subunit of protein phosphatase 2A (PP2A) with long IDRs that harbor a substrate-mimicking SLiM and multiple phosphorylation sites. De novo missense mutations in PPP2R5D cause intellectual disabilities (ID), macrocephaly, Parkinsonism, and a broad range of neurological symptoms. Our single-particle cryo-EM structures of the PP2A-B56δ holoenzyme reveal that the long, disordered arms at the B56δ termini fold against each other and the holoenzyme core. This architecture suppresses both the phosphatase active site and the substrate-binding protein groove, thereby stabilizing the enzyme in a closed latent form with dual autoinhibition. The resulting interface spans over 190 Å and harbors unfavorable contacts, activation phosphorylation sites, and nearly all residues with ID-associated mutations. Our studies suggest that this dynamic interface is coupled to an allosteric network responsive to phosphorylation and altered globally by mutations. Furthermore, we found that ID mutations increase the holoenzyme activity and perturb the phosphorylation rates, and the severe variants significantly increase the mitotic duration and error rates compared to the normal variant.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration and Concept of Operations for a Zero-Knowledge Protocol Passive Imaging Measurement for Arms Control

Here, we present an imaging system that employs zero-knowledge protocols to protect sensitive geometrical information, along with procedures to increase confidence in the result. The goal of this work is to enable the inclusion of warhead confirmation measurements in future arms control treaties. We present a demonstration of both true positive and true negative measurements that validate models and establish authenticating procedures toward meeting acceptance requirements for use in nuclear facilities. We use a two-dimensional time-encoded fast neutron imaging system with an anti-symmetric mask pattern; the fast neutron count values exceeding minimum or maximum thresholds indicate that two measured items are not identical. Laboratory measurements over twenty trials show that alarm rates for negative confirmation measurements are within uncertainties of model predictions. Positive confirmation measurements indicate that alarm rates are large enough to encourage treaty compliance.

Sweany, Melinda Dominique [Sandia National Laborat↗

ON THE INTRINSIC CONTINUUM LINEAR POLARIZATION OF CLASSICAL Be STARS: THE EFFECTS OF METALLICITY AND ONE-ARMED DENSITY PERTURBATIONS

We report on the effects of two disk properties on the continuum linear polarization signature of classical Be stars. First, we investigate the effect of including metallicity in computing the thermal structure of the circumstellar gas on the resulting polarimetric Balmer jump. The Balmer jump is a distinguishing feature of the polarization signature in these objects and, as such, can be used as a tool for differentiating classical Be stars from similar H{alpha}-emitters identified through conventional photometric techniques. We find that although low-metallicity environments will have hotter disk temperatures on average, the temperature change alone cannot account for the discrepancy in the frequency of Balmer jumps between low-metallicity and solar-metallicity stellar populations. Second, we investigate the effect of including a global one-armed oscillation in the gas density distribution of the modeled disk. We find that a non-axisymmetric perturbation pattern yields discernible variations in the predicted polarization level. If these density oscillations are present in the inner region of classical Be star disks, the polarimetric variations should produce a periodic signature which can help characterize the dynamical nature of the gas near the star.

79 ASTRONOMY AND ASTROPHYSICS↗

SNR G349.7+0.2: A γ-RAY SOURCE IN THE FAR 3 kpc ARM OF THE GALACTIC CENTER

We analyze the H I absorption profile for TeV supernova remnant (SNR) G349.7+0.2 based on updated knowledge of the inner Galaxy's structure. We significantly revise its kinematic distance from the previous ∼22 kpc to ∼11.5 kpc, indicating it is in the far 3 kpc arm of the Galactic center. We give a revised age of ∼1800 yr for G349.7+0.2 which has a low explosion energy of ∼2.5 × 10{sup 50} erg. This removes G349.7+0.2 from the set of brightest SNRs in radio and X-ray to γ-ray wavebands and helps us to better understand γ-ray emission originating from this remnant. However, one needs to use caution when discussing old kinematic distances of Galactic objects (e.g., SNRs, pulsars, and H II regions) in the range of –12° ≤ l ≤ 12° with distance estimates of ≥5.5 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

RECENT STAR FORMATION IN THE LEADING ARM OF THE MAGELLANIC STREAM

Strongly interacting galaxies undergo a short-lived but dramatic phase of evolution characterized by enhanced star formation, tidal tails, bridges, and other morphological peculiarities. The nearest example of a pair of interacting galaxies is the Magellanic Clouds, whose dynamical interaction produced the gaseous features known as the Magellanic Stream trailing the pair's orbit about the Galaxy, the bridge between the Clouds, and the leading arm (LA), a wide and irregular feature leading the orbit. Young, newly formed stars in the bridge are known to exist, giving witness to the recent interaction between the Clouds. However, the interaction of the Clouds with the Milky Way (MW) is less well understood. In particular, the LA must have a tidal origin; however, no purely gravitational model is able to reproduce its morphology and kinematics. A hydrodynamical interaction with the gaseous hot halo and disk of the Galaxy is plausible as suggested by some models and supporting neutral hydrogen (H I) observations. Here we show for the first time that young, recently formed stars exist in the LA, indicating that the interaction between the Clouds and our Galaxy is strong enough to trigger star formation in certain regions of the LA—regions in the outskirts of the MW disk (R ∼ 18 kpc), far away from the Clouds and the bridge.

79 ASTRONOMY AND ASTROPHYSICS↗

THE BEHAVIOR OF THE PITCH ANGLE OF SPIRAL ARMS DEPENDING ON OPTICAL WAVELENGTH

Based on integral field spectroscopy data from the CALIFA survey, we investigate the possible dependence of spiral arm pitch angle with optical wavelength. For three of the five studied objects, the pitch angle gradually increases at longer wavelengths. This is not the case for two objects where the pitch angle remains constant. This result is confirmed by the analysis of SDSS data. We discuss the possible physical mechanisms to explain this phenomenon, as well as the implications of the results.

79 ASTRONOMY AND ASTROPHYSICS↗

Output-weighted sampling for multi-armed bandits with extreme payoffs

We present a new type of acquisition function for online decision-making in multi-armed and contextual bandit problems with extreme payoffs. Specifically, we model the payoff function as a Gaussian process and formulate a novel type of upper confidence bound acquisition function that guides exploration towards the bandits that are deemed most relevant according to the variability of the observed rewards. This is achieved by computing a tractable likelihood ratio that quantifies the importance of the output relative to the inputs and essentially acts as an attention mechanism that promotes exploration of extreme rewards. Our formulation is supported by asymptotic zero-regret guarantees, and its performance is demonstrated across several synthetic benchmarks, as well as two realistic examples involving noisy sensor network data. Finally, we provide a JAX library for efficient bandit optimization using Gaussian processes.

Science & Technology - Other Topics↗

Advanced Modeling Fast Simulation Algorithms for Alternate Arm Converters

There is increasing interest in alternate arm converter (AAC) due to the fault-tolerant characteristics it could offer in high-voltage direct current (HVdc) systems. The simulation of AACs is important to assist with the design of hardware, control systems, and planning of power system expansions. However, simulation of AAC-HVdc using existing software takes a long time due to the presence of a large number of states and non-linear devices. An ultra-fast single-or multi-CPU simulation algorithm to simulate the AAC-HVdc system based on state-space models and using hybrid discretization algorithm with a relaxation technique that reduces the imposed computational burden is presented in this paper. The developed algorithm is validated with respect to reference PSCAD/EMTDC model.

Debnath, Suman↗

SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613; Elekta Sponsored Research.

60 APPLIED LIFE SCIENCES↗

Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system

Purpose: To propose new dose point measurement-based metrics to characterize the dose distributions and the mean dose from a single partial rotation of an automatic exposure control-enabled, C-arm-based, wide cone angle computed tomography system over a stationary, large, body-shaped phantom. Methods: A small 0.6 cm{sup 3} ion chamber (IC) was used to measure the radiation dose in an elliptical body-shaped phantom made of tissue-equivalent material. The IC was placed at 23 well-distributed holes in the central and peripheral regions of the phantom and dose was recorded for six acquisition protocols with different combinations of minimum kVp (109 and 125 kVp) and z-collimator aperture (full: 22.2 cm; medium: 14.0 cm; small: 8.4 cm). Monte Carlo (MC) simulations were carried out to generate complete 2D dose distributions in the central plane (z = 0). The MC model was validated at the 23 dose points against IC experimental data. The planar dose distributions were then estimated using subsets of the point dose measurements using two proposed methods: (1) the proximity-based weighting method (method 1) and (2) the dose point surface fitting method (method 2). Twenty-eight different dose point distributions with six different point number cases (4, 5, 6, 7, 14, and 23 dose points) were evaluated to determine the optimal number of dose points and their placement in the phantom. The performances of the methods were determined by comparing their results with those of the validated MC simulations. The performances of the methods in the presence of measurement uncertainties were evaluated. Results: The 5-, 6-, and 7-point cases had differences below 2%, ranging from 1.0% to 1.7% for both methods, which is a performance comparable to that of the methods with a relatively large number of points, i.e., the 14- and 23-point cases. However, with the 4-point case, the performances of the two methods decreased sharply. Among the 4-, 5-, 6-, and 7-point cases, the 7-point case (1.0% [±0.6%] difference) and the 6-point case (0.7% [±0.6%] difference) performed best for method 1 and method 2, respectively. Moreover, method 2 demonstrated high-fidelity surface reconstruction with as few as 5 points, showing pixelwise absolute differences of 3.80 mGy (±0.32 mGy). Although the performance was shown to be sensitive to the phantom displacement from the isocenter, the performance changed by less than 2% for shifts up to 2 cm in the x- and y-axes in the central phantom plane. Conclusions: With as few as five points, method 1 and method 2 were able to compute the mean dose with reasonable accuracy, demonstrating differences of 1.7% (±1.2%) and 1.3% (±1.0%), respectively. A larger number of points do not necessarily guarantee better performance of the methods; optimal choice of point placement is necessary. The performance of the methods is sensitive to the alignment of the center of the body phantom relative to the isocenter. In body applications where dose distributions are important, method 2 is a better choice than method 1, as it reconstructs the dose surface with high fidelity, using as few as five points.

60 APPLIED LIFE SCIENCES↗