Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANGLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Powder diffraction by fixed incident angle reflection using a curved position-sensitive detector

As curved position-sensitive detectors improve in angular resolution, the effects that fixed incident angle reflection have on X-ray diffraction peaks become more apparent. In this study the effects of sample transparency, incident beam height, detector resolution and sample displacement on the intensity, location, width and shape of powder diffraction peaks were examined. The functions describing each of these phenomena are presented and were successfully used to quantitatively model the diffraction peaks collected in this geometry. Three distinct regimes of diffraction peak resolution were identified from the phenomena that limit the peak variance. Pertinent criteria based on experimental parameters have been outlined to classify fixed incident angle reflection experiments into each regime. Guidelines for improvement of experimental resolution and for conducting analysis of data acquired using fixed incident angle reflection geometry and curved position-sensitive detectors are also provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A direct approach to estimate the anisotropy of protein structures from small-angle X-ray scattering

In the field of small-angle X-ray scattering (SAXS), the task of estimating the size of particles in solution is usually synonymous with the Guinier plot. The approximation behind this plot, developed by Guinier in 1939, provides a simple yet accurate characterization of the scattering behavior of particles at low scattering angle or momentum transfer q , together with a computationally efficient way of inferring their radii of gyration R G . Moreover, this approximation is valid beyond spherical scatterers, making its use ubiquitous in the SAXS world. However, when it is important to estimate further particle characteristics, such as the anisotropy of the scatterer's shape, no similar or extended approximations are available. Existing tools to characterize the shape of scatterers rely either on prior knowledge of the scatterers' geometry or on iterative procedures to infer the particle shape ab initio . In this work, a low-angle approximation of the scattering intensity I ( q ) for ellipsoids of revolution is developed and it is shown how the size and anisotropy information can be extracted from the parameters of that approximation. The goal of the approximation is not to estimate a particle's full structure in detail, and thus this approach will be less accurate than well known iterative and ab initio reconstruction tools available in the literature. However, it can be considered as an extension of the Guinier approximation and used to generate initial estimates for the aforementioned iterative techniques, which usually rely on R G and D max for initialization. This formulation also demonstrates that nonlinearity in the Guinier plot can arise from anisotropy in the scattering particles. Beyond ideal ellipsoids of revolution, it is shown that this approximation can be used to estimate the size and shape of molecules in solution, in both computational and experimental scenarios. The limits of the approach are discussed and the impact of a particle's anisotropy in the Guinier estimate of R G is assessed.

catalysis (homogeneous), catalysis (heterogeneous)↗

2017 publication guidelines for structural modelling of small-angle scattering data from biomolecules in solution: an update

In 2012, preliminary guidelines were published addressing sample quality, data acquisition and reduction, presentation of scattering data and validation, and modelling for biomolecular small-angle scattering (SAS) experiments. Biomolecular SAS has since continued to grow and authors have increasingly adopted the preliminary guidelines. In parallel, integrative/hybrid determination of biomolecular structures is a rapidly growing field that is expanding the scope of structural biology. For SAS to contribute maximally to this field, it is essential to ensure open access to the information required for evaluation of the quality of SAS samples and data, as well as the validity of SAS-based structural models. To this end, the preliminary guidelines for data presentation in a publication are reviewed and updated, and the deposition of data and associated models in a public archive is recommended. These guidelines and recommendations have been prepared in consultation with the members of the International Union of Crystallography (IUCr) Small-Angle Scattering and Journals Commissions, the Worldwide Protein Data Bank (wwPDB) Small-Angle Scattering Validation Task Force and additional experts in the field.

Biochemistry & Molecular Biology↗

Genetic Algorithm-Based Commutation Angle Control for Torque Ripple Mitigation in Switched Reluctance Motor Drives

This work addresses the application of the Genetic Algorithm (GA) technique to optimize the commutation angles of a 2 kW 8/6 switched reluctance machine (SRM). The primary goal is to reduce the well-known drawback of SRMs: the torque ripple. Firstly, the machine was modeled in Matlab /Simulink ® using lookup tables obtained via finite element method (FEM) simulations. Subsequently, the model was used to perform the GA routine aiming to find the optimal phase commutation angles that minimize the torque ripple factor. Notably, the torque performance of the SRM was significantly affected by the commutation angles during the search for the optimal solution. Afterwards, the GA results for four different operation points were verified experimentally through a developed drive platform with digital signal processor-based (DSP) control and an asymmetric bridge converter. As showed by the experiments, the proposed approach was suitable to reduce the torque ripple by more than 50% for one of the evaluated operating points. Furthermore, it was confirmed that the torque ripple mitigation led to acoustic noise improvement.

42 ENGINEERING↗

Influence of substrate temperature on glancing angle deposited Ag nanorods

When Ag sculptured thin films were grown with glancing angle deposition by ion beam sputtering at either room temperature or elevated substrate temperatures T{sub S}, a large morphological difference was observed. The incident particle flux reached the silicon substrate at a glancing angle {beta}{>=}80 deg. as measured to the substrate normal. A slit aperture was used in order to reduce the particle beam divergence. At room temperature, columnar structures were formed, irrespective of the presence of the slit aperture. At elevated temperatures (573 and 623 K) and collimated particle flux in the presence of the slit aperture, however, enhanced surface diffusion causes the growth of crystalline nanorod- and nanowirelike structures. In the absence of the slit aperture, the flux beam divergence is higher, resulting in island- and mountainlike crystalline structures. The density of the nanorods and nanowires was observed to be higher on the planar Si substrates in comparison to honeycomblike prepatterned substrates with different pattern periods. On the patterned substrates, the nanorods are not necessarily found to be evolving on the seed points but can rather be also observed in-between the artificial seeds. The glancing angle deposited films at high temperatures were observed to be polycrystalline, where the (111) crystal orientation of the film is dominant, while the presence of the less intense (200) reflection was noticed from the x-ray diffraction measurements. In contrast, compact thin films deposited with {beta}{approx_equal}0 deg. at high temperatures were found to be epitaxial with (200) orientation.

36 MATERIALS SCIENCE↗

Correlation of plasma characteristics to etch rate and via sidewall angle in a deep reactive ion etch system using Langmuir probe and optical emission spectroscopy

A Langmuir probe and optical emission spectroscopy were used in a deep reactive ion etch system to correlate plasma parameters (atomic fluorine and argon emission, electron density, ion density, and electron average energy) with the etch rate and via sidewall angle. All data were obtained for coil powers ranging from 200 to 800 W, platen powers ranging from 7 to 16 W, and pressure ranging from 3.8 to 62 mTorr with constant SF{sub 6} and Ar flow rates of 112 and 18 SCCM (SCCM denotes cubic centimeter per minute at STP), respectively. Results indicate that there is a correlation with etch rate for all plasma parameters except for argon emission. For argon emission, the etch rate exhibits a double-valued relation where the etch rate can either increase or decrease with increasing argon emission intensity due to changes in pressure which affect the energy coupling efficiency. As expected, the etch rate increases for measured increases in fluorine emission, electron density, and ion density. The etch rate, however, decreases with increasing average electron energy due to collision processes. In contrast, no correlation is observed between any of the measured plasma parameters with sidewall angle. The last result is consistent with the idea that sidewall angle is primarily controlled by the passivation cycle as opposed to the etching cycle, where all the authors' data were obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the infrared optical constants for spectral modeling: n and k values for (NH4)2SO4 via single-angle reflectance and ellipsometric methods

The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to do this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.

ammonium sulfate↗

Method for evaluating bow tie filter angle-dependent attenuation in CT: Theory and simulation results

Purpose: Dosimetry in computed tomography (CT) is increasingly based on Monte Carlo studies that define the dose in the patient (in mGy) as a function of air kerma (free in air) at isocenter (mGy). The accuracy of Monte Carlo studies depends in part on the accuracy of the characterization of the bow tie filter for a given CT scanner model. A simple method for characterizing the bow tie filter attenuation profile in CT scanners would therefore be very useful. The theory behind such a method is proposed. Methods: A measurement protocol is discussed mathematically and demonstrated using computer simulation. The proposed method requires the placement of a radiation monitor at the periphery of the CT field, and the time domain signal (kerma rate versus time) is measured with good temporal resolution ({approx}200 Hz or better) and with all other objects (e.g., patient couch) retracted from the field of view. Knowledge of the source to isocenter distance (or alternately, the isocenter to probe distance) is required. The stationary detector records the kerma rate versus time signal as the gantry rotates through several revolutions. From this temporal data, signal processing techniques are used to extract in-phase peaks, as well as out-of-phase kerma rate levels. From these data, the distance from isocenter to the probe can be determined (or, alternatively, the source to isocenter distance), and the angle-dependent bow tie filter attenuation can be computed. By measuring the angle-dependent bow tie filter attenuation at several kVp settings, the bow tie composition versus fan angle can be computed using basis decomposition techniques. Results: The simulations illustrated that with 2% added noise in the kerma rate versus time signal, the attenuation properties of a hypothetical two component (aluminum and polymethyl methacrylate) bow tie filter could be determined (r{sup 2}>0.99). Although the computed basis material thicknesses were not exactly equal to the actual thicknesses, their combined attenuation factors matched that of the actual filter across kVp's to within an average of 0.057%. Conclusions: It is concluded that the proposed method may provide a simple noninvasive approach to characterizing the performance of bow tie filters in CT systems; however, experimental validation is necessary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-201: Impact of Gantry and Table Angles On Proton Range in XiO Treatment Planning System

Purpose: To investigate if the selection of gantry and table angle has an impact on the calculated proton range (defined at the 90% distal falloff of the spread out Bragg peak) in XiO treatment planning system (TPS). Methods: A homogenous water phantom (40x40x40 cm{sup 3}) was constructed in XiO TPS. Ten treatment plans were generated using identical beam conditions (proton range = 25cm, modulation = 10cm) and device (10 cm diameter aperture) for various combinations of gantry (G) and table (T) angles (G0T90, G90T90, G180T90, G270T90, G90T0, G90T180, G90T270, G270T0, G270T180, and G270T270). The isocenter in each plan was selected at the center of the cubic target volume (5x5x5 cm{sup 3}) inside the phantom. All ten plans were calculated with pencil beam algorithm using a grid size of 3mm. The calculated proton ranges in all 10 plans were then compared against the prescribed (or expected) proton range, which was 25 cm in this study. Results: For all 10 treatment plans, calculated proton range was smaller when compared to the expected value (25cm), with XiO predicting the proton range from 24.62cm to 24.92cm. The difference between the prescribed and calculated proton range was highest (3.8mm) for plans with G90T270 and G270T90. Conclusion: Treatment plans generated in XiO TPS using G90T270 and G270T90 could produce a difference of more than 3 mm between the prescribed and calculated proton ranges. Further study using smaller dose calculation grid size (e.g., 1mm) is under progress to determine if the dose calculation grid size has any impact on the proton range. What causes the angle dependence of proton range calculation with the XiO TPS is also under investigation.

60 APPLIED LIFE SCIENCES↗

Correlated insulating and superconducting states in twisted bilayer graphene below the magic angle

The emergence of flat bands and correlated behaviors in “magic angle” twisted bilayer graphene (tBLG) has sparked tremendous interest, though its many aspects are under intense debate. Here we report observation of both superconductivity and the Mott-like insulating state in a tBLG device with a twist angle of ~0.93°, which is smaller than the magic angle by 15%. At an electron concentration of ±5 electrons/moiré unit cell, we observe a narrow resistance peak with an activation energy gap ~0.1 meV. This indicates additional correlated insulating state, and is consistent with theory predicting a high-energy flat band. At doping of ±12 electrons/moiré unit cell we observe resistance peaks arising from the Dirac points in the spectrum. Our results reveal that the “magic” range of tBLG is in fact larger than what is previously expected, and provide a wealth of new information to help decipher the strongly correlated phenomena observed in tBLG.

36 MATERIALS SCIENCE↗

Transition radiation in a dihedral angle formed by perfectly conducting planes

The spatial distribution of the field of transition radiation generated by a relativistic particle flying into a dihedral angle formed by perfectly conducting plane surfaces is determined. The cases when particles are injected from the edge and from a plane of the dihedral angle are considered. The angular distributions of radiation intensity in dihedral angles of different values are calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular distributions of reflected and refracted relativistic electron beams crossing a thin planar target at a small angle to its surface

The scattering of electrons by aluminum, copper, and lead foils, as well as by bimetallic aluminum-lead and aluminum-copper foils, has been studied experimentally. A microtron with an energy of particles of 7.4 MeV has been used as a source of electrons. The beam of particles incident on a target at small angles is split into particles reflected from the foil, which constitute a reflected beam, and particles crossing the foil, which constitute a refracted beam. The effect of the material and thickness of the foil, as well as the angle between the initial trajectory of the beam and the plane of the target, on the direction of motion and the angular divergence of the beam crossing the foil and the beam reflected from the foil has been analyzed. Furthermore, the effect of the sequence of metal layers in bimetallic films on the angles of refraction and reflection of the beam has been examined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Backscattering of Relativistic Electrons Incident on a Planar Foil at a Small Angle to Its Surface

Photographs of cross sections of an electron beam backscattered from a thin tungsten target have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of backscattered particles. The angles of back reflection θ{sub br} of electron beams from foils have been measured. A 7.4-MeV microtron has been used as a source of electrons. The experiments have been performed with a tungsten foil 386 mg/cm{sup 2} (200 μm) thick and a tantalum foil 1328 mg/cm{sup 2} (800 μm) thick. Particles have been injected at an angle of α = 10° to the foil surface. The Monte Carlo simulation of the scattering of relativistic electrons incident on a planar target at small angles to its surface has been performed. The spatial and energy distributions of backscattered particle fluxes both transmitted through the target and reflected from it have been calculated. The dependences of fluxes on the direction of injection of particles and on the material and thickness of the target have been considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Skyrmion dynamics and transverse mobility: skyrmion Hall angle reversal on 2D periodic substrates with dc and biharmonic ac drives

Here we numerically examine the dynamics of a skyrmion interacting with a two-dimensional periodic substrate under dc and biharmonic ac drives. We show that the Magnus force of the skyrmion produces circular orbits that can resonate with the ac drive and the periodicity of the substrate to create quantized motion both parallel and perpendicular to the dc drive. The skyrmion Hall angle exhibits a series of increasing and/or decreasing steps along with strongly fluctuating regimes. In the phase locked regimes, the skyrmion Hall angle is constant and the skyrmion motion consists of periodic orbits encircling an integer number of obstacles per every or every other ac drive cycle. We also observe phases in which the skyrmion moves at 90° with respect to the driving direction even in the presence of damping, a phenomenon called absolute transverse mobility that can exhibit reentrance as a function of dc drive. When the biharmonic ac drives have different amplitudes in the two directions, we find regimes in which the skyrmion Hall angle shows a sign reversal from positive to negative, as well as a reentrant pinning effect in which the skyrmion is mobile at low drives but becomes pinned at higher drives. These behaviors arise due to the combination of the Magnus force with the periodic motion of the skyrmions, which produce Shapiro steps, directional locking, and ratchet effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗

Measurement of angle and axis of rotation in a carousel interferometer: a detailed analysis

A detailed analysis of a carousel interferometer is presented for the measurement of an unknown angle and axis of rotation. The technique exploits a set of compensator glass plates and a right-angle prism that is placed in each of the two arms of the interferometer. The two sets are placed at the same rotational stage, while the end mirrors of the interferometer are static. When rotation takes place, individual and relative optical path differences are generated in the two beams of the interferometer. The generated phase differences contribute toward finding the angle and axis of rotation. The analysis is presented for any initial position of the interferometer, i.e., the radial vector from the axis of rotation to the apex of one of the prisms used. The results show the slight variations in the error and nonlinearity when different parameters are manipulated. Moreover, the trade-off between the maximum size of the prisms and the radial distances are also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗