Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

60 APPLIED LIFE SCIENCES↗

Experimental investigation on spectral-energy efficiency of femtosecond laser ablation of metals

Results of investigation on spectral-energy thresholds, rates, and mass flow rates of laser ablation of structural materials (Cu, Ti, Zr, Nb, Mo) of high-energy photonics are presented. The data were obtained by means of an experimental diagnostic module developed for study of multifactor interaction processes between UV-near IR femtosecond laser pulse radiation and condensed media in vacuum.

36 MATERIALS SCIENCE↗

Electron Temperature Distribution Measurements in Clouds of Polystyrene Pellets Ablating in LHD Heliotron Plasma

Two methods for measuring the spatial distribution of the temperature of electrons in a cloud near a polystyrene pellet that ablates in LHD heliotron plasma are described. The first method is based on measuring the ratio of the local emission-coefficient values at wavelengths of 486 ± 5 nm (the H{sub β} line) and 630 ± 5 nm (continuum). The second (new) method is based on the measurement of radiation distributions of the H{sub β} line in the direction along the magnetic field. Both the methods use an assumption about the partial local thermodynamic equilibrium in the cloud and show close results. It is shown for the first time that the temperature of cloud electrons increases from 0.8 eV in the immediate vicinity of the pellet surface to 6.0–7.0 eV at a distance of 6–8 mm from the pellet in the direction along the magnetic field, which agrees with the experimentally observed longitudinal distribution of the H{sub β} radiation in the cloud.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modelling of Ablatant Deposition from Electromagnetically Driven Radiative Pellets for Disruption Mitigation Studies

The Electromagnetic Particle Injector (EPI) concept is advanced through the simulation of ablatant deposition into ITER H-mode discharges with calculations showing penetration past the H-mode pedestal for a range of injection velocities and granule sizes concurrent with the requirements of disruption mitigation. As discharge stored energy increases in future fusion devices such as ITER, control and handling of disruption events becomes a critical issue. An unmitigated disruption could lead to failure of the plasma facing components resulting in financially and politically costly repairs. Methods to facilitate the quench of an unstable high current discharge are required. With the onset warning time for some ITER disruption events estimated to be less than 10 ms, a disruption mitigation system needs to be considered which operates at injection speeds greater than gaseous sound speeds. Such an actuator could then serve as a means to augment presently planned pneumatic injection systems. The EPI uses a rail gun concept whereby a radiative payload is delivered into the discharge by means of the JxB forces generated by an external current pulse, allowing for injection velocities in excess of 1 km/s. The present status of the EPI project is outlined, including the addition of boost magnetic coils. These coils augment the self-generated rail gun magnetic field and thus provide a more efficient acceleration of the payload. The coils and the holder designed to constrain them have been modelled with the ANSYS code to ensure structural integrity through the range of operational coil cu

disruption↗

Laser Ablation Reducer Application

The LARA code imports laser ablation experiments data and reduces the data according to mass and IC gain standards selected by the user. It produces graphics illustrating the results, and writes output data to file. The LARA code was developed in R, and is run within a session of RStudio.

Samperton, KyleM.↗

Process Development and Micro-Machining of MARBLE Foam-Cored Rexolite Hemi-Shell Ablator Capsules

For this study, machined CH hemi-shell ablator capsules have been successfully produced by the MST-7 Target Fabrication Team at Los Alamos National Laboratory. Process development and micro-machining techniques have been developed to produce capsules for both the Omega and National Ignition Facility (NIF) campaigns. These capsules are gas filled up to 10 atm and consist of a machined plastic hemi-shell outer layer that accommodates various specially engineered low-density polystyrene foam cores. Machining and assembly of the two-part, step-jointed plastic hemi-shell outer layer required development of new techniques, processes, and tooling while still meeting very aggressive shot schedules for both campaigns. Finally, problems encountered and process improvements will be discussed that describe this very unique, complex capsule design approach through the first Omega proof-of-concept version to the larger NIF version.

42 ENGINEERING↗

Quantitative Defect Analysis of Ablator Capsule Surfaces Using a Leica Confocal Microscope and a High-Density Atomic Force Microscope

High-density carbon (HDC) is being evaluated as an alternative to the current National Ignition Facility (NIF) point-design ablator material (glow discharge plasma, or GDP, plastic) due to its high density and optimal opacity, which leads to a higher implosion velocity. Chemical-vapor-deposition-coated HDC capsules have a near perfect surface figure but a microscopically rough surface. After polishing, the surface becomes smooth at nanometer scales but has numerous micron-sized surface pits, whose volumes, morphology, and distribution must be quantified to guide NIF target selection. Traditional metrology tools for GDP surface defects, such as the atomic force microscope (AFM) based Spheremapper and a phase-shifting differential interferometer, lack the resolution to characterize these localized features. In this paper, we describe how this metrology challenge is met by developing automated surface metrology solutions based on a high-density (HD) AFM and a Leica confocal microscope. Furthermore, these tools are complementary in nature. HD-AFM has a 0.1-μm spatial resolution and determines the overall shape distortion and pit statistics by tracing great circles on a capsule with high throughput.

36 MATERIALS SCIENCE↗

Femtosecond UV laser non-ablative surface structuring of ZnO crystal: impact on exciton photoluminescence

The ultraviolet (UV) laser irradiation (248 nm) of monocrystalline wurtzite ZnO with 450 fs pulses results in surface modification. A formation of two orthogonal ripple structures with a period of 400-500 nm was observed oriented parallel and perpendicular to the laser beam polarization. The UV exciton emission obtained on the irradiated domains is found greatly enhanced locally up to {approx}10{sup 3} times. The photoluminescence band is redshifted by 2-3 nm and 40% narrower (full width at half-maximum), while at the same time the E{sub 2} (439 cm{sup -1}) Raman band intensity increases up to {approx}50 times. The process is found irreversible with the threshold fluence of 11 mJ/cm{sup 2}, which is considerably lower than the ablation threshold 115 mJ/cm{sup 2}. Fine surface nanostructuring on the scale of {approx}10 nm may be responsible for the observed effect. (c) 2008 Optical Society of America.

36 MATERIALS SCIENCE↗

Laser ablation-inductively coupled plasma-mass spectrometry: Examinations of the origins of polyatomic ions and advances in the sampling of particulates

This dissertation provides a general introduction to Inductively coupled plasma-mass spectrometry (ICP-MS) and laser ablation (LA) sampling, with an examination of analytical challenges in the employment of this technique. It discusses the origin of metal oxide ions (MO+) in LA-ICP-MS, as well as the effect of introducing helium and nitrogen to the aerosol gas flow on the formation of these polyatomic interferences. It extends the study of polyatomic ions in LA-ICP-MS to metal argide (MAr+) species, an additional source of possible significant interferences in the spectrum. It describes the application of fs-LA-ICP-MS to the determination of uranium isotope ratios in particulate samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic stabilization of the ablative Rayleigh-Taylor instability for heavy ion fusion

Dynamic stabilization of the ablative Rayleigh-Taylor instability of a heavy ion fusion target induced by a beam wobbling system is studied. Using a sharp-boundary model and Courant-Synder theory, it is shown, with an appropriately chosen modulation waveform, that the instability can be sta- bilized in certain parameter regimes. It is found that the stabilization e ect has a strong dependence on the modulation frequency and the waveform. Modulation with frequency comparable to the instability growth rate is the most e ective in terms of stabilizing the instability. A modulation with two frequency components can result in a reduction of the growth rate larger than the sum of that due to the two components when applied separately.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of femtosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements in U-10Mo nuclear fuel foils

The use of femtosecond laser ablation inductively coupled plasma mass spectrometry was used to demonstrate the feasibility of measuring the isotopic ratio of uranium directly in U-10Mo fuel foils. The measurements were done on both the flat surface and cross sections of bare and Zr clad U-10Mo fuel foil samples. The results for the depleted uranium content measurements were less than 10% of the accepted U235/238 ratio of 0.0020. Sampling was demonstrated for line scans and elemental mapping over large areas. In addition to the U isotopic ratio measurement, the Zr thickness could be measured as well as trace elemental composition if required. A number of interesting features were observed during the feasibility measurements which could provide the basis for further investigation using this methodology. The results demonstrate the feasibility of using fs-LA-ICP-MS for measuring the U isotopic ratio in U-10Mo fuel foils.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Trace metal analysis by laser ablation-inductively coupled plasmamass spectrometry and x-ray K-edge densitometry of forensic samples

This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in cases where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Dopant Optical Spectroscopy via Laser Ablation for High Resolution Spectral Measurements

The goal of this exploratory express LDRD is to demonstrate a reproducible laser activated doping diagnostic for eventual use on the Z machine by producing consistent spectral line emission with radiances above 10 5 W sr -1 nm -1 111 -2 from a variety of dopant materials. Here we show that while such radiances are achieved, the line emission is from regions with high electron densities, and close to the laser ablation surface. Therefore, it would be more ideal to improve current optical spectroscopy capabilities on Z to view radiances around 10 4 W sr -l nm -l m -2 . We also discuss the viability of a modular beam path that can be remotely aligned and used on the Z machine. This technique can be used to make spatially resolved measurements of electric and magnetic field strengths and electron densities within the Z power flow and load regions. The measurements can also be used to inform theory and simulation efforts needed to design the next generation of pulsed power capabilities. This was funded as an exploratory LDRD project, number: 214278

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ablative Magnetohydrodynamic Rayleigh-Taylor Instability (Final Technical Report)

The Rayleigh-Taylor Instability (RTI) is a ubiquitous flow phenomenon occurring in a multitude of natural and engineered systems in which buoyancy forces exist. RTI is primarily a limiting process in many HED applications and there are significant efforts within the NNSA-ICF program to account for its effect in large scale simulations of ICF implosions both in two- and three-dimensions. The goal of the proposed research is to develop a fundamental understanding of the evolution and role of magnetic fields in the ablative Rayleigh–Taylor instability (aRTI) in the deeply nonlinear stage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Energy Density Physics of Inertial Confinement Fusion Ablator Materials (Final Technical Report)

The goal of this project was to conduct dynamic compression experiments and predictive simulations to reveal the fundamental high-energy-density (HED) physics of amorphous carbon. These results are essential for assessing amorphous carbon as a potential ablator material for next generation of inertial confinement fusion (ICF) capsules. We made significant progress in exploring the HED properties of amorphous carbon through experiments at Omega EP Laser and the European XFEL, in addition to billion-atom, quantum-accurate molecular dynamics (MD) simulations. Through our joint experimental and simulation program, we mapped the phase diagram of amorphous carbon, uncovering its range of metastability and identifying phase transitions to diamond and liquid carbon along the Hugoniot and at higher pressures using double shock compression pathways. Our findings indicate that amorphous carbon melts at significantly lower shock pressures than high-density carbon (diamond). However, nanocrystalline diamond nucleates across a broad range of pressures and temperatures. This emergence of the nanocrystalline microstructure during compression can negatively impact the planarity of the shock front and potentially trigger ablator/fuel mixing during Inertial Fusion Energy (IFE) applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Investigation of Oxides of Tantalum Produced by Pulsed Laser Ablation and Continuous Wave Laser Heating

Recent progress has seen multiple Ta 2 O 5 polymorphs generated by different synthesis techniques. However, discrepancies arise when these polymorphs are produced in widely varying thermodynamic conditions and characterized using different techniques. This work aimed to characterize and compare Ta 2 O 5 particles formed at high and low temperatures using nanosecond pulsed laser ablation (PLA) and continuous wave (CW) laser heating of a local area of tantalum in either air or an 18 O 2 atmosphere. Scanning electron microscopy (SEM) and Raman spectroscopy of the micrometer-sized particles generated by PLA were consistent with either a localized amorphous Ta 2 O 5 phase or a similar, but not identical, crystalline β-Ta 2 O 5 phase. The Raman spectrum of the material formed at the point of CW laser impingement was in good agreement with the previously established ceramic “H-Ta 2 O 5 ” phase. TEM and electron diffraction analysis of these particles indicated the phase structure matched an oxygen-vacated superstructure of monoclinic H-Ta 2 O 5 . Further from the point of laser impingement, CW heating produced particles with a Raman spectrum that matched β-Ta 2 O 5 . We confirmed that the high-temperature ceramic phase characterized in previous work by Raman spectroscopy was the same monoclinic phase characterized in different work by TEM and could be produced by direct laser heating of metal in air.

36 MATERIALS SCIENCE↗