Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultraviolet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of {delta}{sigma}=0.33 cm{sup -1} (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to {lambda}=58 nm with an ultimate resolving power of 500 000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O{sub 2} (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth ''white'' beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

43 PARTICLE ACCELERATORS↗

Ionic debris measurement of three extreme ultraviolet sources

Generation of debris in extreme ultraviolet (EUV) light sources is an inherent and real threat to the lifetime of collection optics. Debris measurement of these sources is useful to enable source suppliers to estimate collector lifetime. At the Center for Plasma Material Interactions (CPMI) at the University of Illinois, an Illinois calibrated spherical sector electrostatic energy analyzer (ICE) was built to measure the ion debris flux in absolute units. In addition to ion flux, the detector is also capable of identifying different ion species present in the plasma utilizing energy-to-charge ratio discrimination. The lifetime of the collector optics is calculated using the measured ion flux. In the current investigation we compare the measurement of ion debris production in three different EUV sources: the Energetiq EQ-10M, the AIXUV-100, and the XTREME XTS 13-35. In the EQ-10M source, three angular measurements are coupled with three variations in operating pressure to measure consequent effects on debris production. These measurements reveal four predominant ion species in the energetic debris analysis: C{sup +}, Si{sup +}, Xe{sup +}, and Xe{sup 2+}. The amount of debris is reduced as pressure is increased. Various debris mitigation methods are implemented in the AIXUV-100 source and results reveal that four ion species are observed (Ar{sup +}, Xe{sup +}, Xe{sup 2+}, and W{sup +}), though there does not seem to be a dominant species. The first mitigation technique, backstreaming argon toward the source, reduces the amount of Ar{sup +}, Xe{sup 2+}, and W{sup +}, yet increases the amount of Xe{sup +} The increase in Xe{sup +} flux is explained based on charge exchange phenomena. The ICE machine was then attached 1.92 m away from the pinch of XTS 13-35 source, and placed at 25 deg. away from the normal line. The comparison of results reveals that the XTS 13-35 and the EQ-10M sources produced comparable amounts of energetic ion flux per watt of EUV light produced. The AIXUV-100 source generated more ion debris flux per watt of EUV light than the other two sources, though it should be noted that the AIXUV-100 source was capable of producing more than ten times the amount of EUV light power compared to any of the other sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Creation of storage centers in CsBr:Eu{sup 2+} needle image plates by vacuum ultraviolet radiation

In this study, the photostimulated luminescence of the CsBr:Eu{sup 2+} needle image plates (NIPS) after vacuum ultraviolet (VUV) irradiation and their photoluminescence under VUV and UV excitation were investigated. It was shown that the photostimulable storage centers arise almost exclusively due to irradiation of the CsBr:Eu NIPs in the spectral lines of creation of the 4p{sup 5}5s anion excitons, and not in the region of interband transitions of CsBr. The explanation of the results is based mainly on the radiative and nonradiative decay of the self-localized e+Br{sub 2}{sup -} excitons.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimization of a gas discharge plasma source for extreme ultraviolet interference lithography at a wavelength of 11 nm

In this work, we report about the optimization of the spectral emission characteristic of a gas discharge plasma source for high-resolution extreme ultraviolet (EUV) interference lithography based on achromatic Talbot self-imaging. The working parameters of the source are optimized to achieve a required narrowband emission spectrum and to fulfill the necessary coherence and intensity requirements. The intense 4f-4d transitions around 11 nm in a highly ionized (Xe{sup 8+}-Xe{sup 12+}) xenon plasma are chosen to provide the working wavelength. This allows us to increase the available radiation intensity in comparison with an in-band EUV xenon emission at 13.5 nm and opens up the possibility to strongly suppress the influence of the 5p-4d transitions at wavelengths between 12 and 16 nm utilizing a significant difference in conditions for optical thickness between 4f-4d and 5p-4d transitions. The effect is achieved by using the admixture of argon to the pinch plasma, which allows keeping the plasma parameters approximately constant while, at the same time, reducing the density of xenon emitters. It is demonstrated that with this approach it is possible to achieve a high intensity 11 nm EUV radiation with a bandwidth of 3%-4% without the use of multilayer mirrors or other additional spectral filters in the vicinity of the working wavelength. The achieved radiation parameters are sufficient for high-performance interference lithography based on the achromatic Talbot effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of ion emission of an extreme ultraviolet generating discharge produced Sn plasma

The ion emission of a Sn-based discharge produced extreme ultraviolet producing plasma is characterized with the combined use of different time-of-flight techniques. An electrostatic ion spectrometer is employed to measure the average charge distribution of the emitted Sn ions. A dedicated Faraday cup configuration is used to measure the total ion flux from the source for different discharge energies. High-energy Sn ions emitted by the plasma with energies up to 100 keV have been identified. The number of high-energy ions increases for higher electrical input energy into the plasma while the signal associated with the expanding plasma ions does not show such dependence. The ion energy distribution for a bulk of detected ions is calculated based on the Faraday cup measurements and compared with theoretical plasma expansion dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient laser-produced plasma extreme ultraviolet sources using grooved Sn targets

An efficient extreme ultraviolet (EUV) generation method has been developed with the use of a CO{sub 2} laser-produced plasma from a grooved target. A approx5% conversion efficiency from laser to 13.5 nm photons was obtained with the use of grooves in a tin target or by repeated laser pulse shots at the same target position. Modeling studies proved that the groove target controls the hydrodynamic expansion of the plasma leading to confinement which prevents the plasma escaping from the EUV production zone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of extreme ultraviolet emission from a discharge-produced potassium plasma for surface morphology application

We have demonstrated a discharge-produced microplasma extreme ultraviolet source based on a pure potassium vapor. Potassium ions produced strong broadband emission around 40 nm with a bandwidth of 8 nm (full width at half-maximum). The current-voltage characteristics of microdischarge suggest that the source operates in a hollow cathode mode. By comparison with atomic structure calculations, the broadband emission is found to be primarily due to 3d-3p transitions in potassium ions ranging from K{sup 2+} to K{sup 4+}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of radiative properties of Sn plasmas for extreme-ultraviolet source

Atomic processes in Sn plasmas are investigated for application to extreme-ultraviolet (EUV) light sources used in microlithography. We develop a full collisional radiative (CR) model of Sn plasmas based on calculated atomic data using Hebrew University Lawrence Livermore Atomic Code (HULLAC). Resonance and satellite lines from singly and multiply excited states of Sn ions, which contribute significantly to the EUV emission, are identified and included in the model through a systematic investigation of their effect on the emission spectra. The wavelengths of the 4d-4f+4p-4d transitions of Sn{sup 5+} to Sn{sup 13+} are investigated, because of their importance for determining the conversion efficiency of the EUV source, in conjunction with the effect of configuration interaction in the calculation of atomic structure. Calculated emission spectra are compared with those of charge exchange spectroscopy and of laser produced plasma EUV sources. The comparison is also carried out for the opacity of a radiatively heated Sn sample. A reasonable agreement is obtained between calculated and experimental EUV emission spectra observed under the typical condition of EUV sources with the ion density and ionization temperature of the plasma around 10{sup 18} cm{sup -3} and 20 eV, respectively, by applying a wavelength correction to the resonance and satellite lines. Finally, the spectral emissivity and opacity of Sn plasmas are calculated as a function of electron temperature and ion density. The results are useful for radiation hydrodynamics simulations for the optimization of EUV sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space-resolved vacuum ultraviolet spectrometer system for edge impurity and temperature profile measurement in HL-2A

A 1 m normal incidence vacuum ultraviolet (VUV) spectrometer has been developed for spatial distribution measurement of edge impurity line emission in the wavelength range of 300-3200 A on HL-2A tokamak. A vertical profile of the impurity line emission is measured with a space-resolved slit placed between an entrance slit and a grating of the spectrometer. Two concave 1200 grooves/mm gratings blazed at 800 and 1500 A are set on a rotatable holder in the spectrometer, which gives wavelength dispersion of 0.12 mm/A. A back-illuminated charge-coupled device is used as a detector with an image size of 6.7x26.6 mm{sup 2} (26x26 {mu}m{sup 2}/pixel). An excellent spatial resolution of 2 mm is obtained with good spectral resolution of 0.15 A when the space-resolved slit of 50 {mu}m in width is used. The space-resolved spectra thus provide three radial profiles of emission line intensity, ion temperature, and poloidal rotation. The electron temperature can be measured by the intensity ratio, e.g., CIII 2s{sup 2}-2s3p (386 A)/2s{sup 2}-2s2p (977 A). The sensitivity of the spectrometer is calibrated in situ by using the VUV bremsstrahlung continuum radiation emitted from the tokamak plasma. A good performance of the spectrometer system for the edge impurity and temperature profile measurements is presented with results on Ohmic and H-mode discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heating dynamics and extreme ultraviolet radiation emission of laser-produced Sn plasmas

The impact of 1.064 mum laser absorption depth on the heating and in-band (2% bandwidth) 13.5 nm extreme ultraviolet emissions in Sn plasmas is investigated experimentally and numerically. In-band emission lasting longer than the laser pulse and separation between the laser absorption and in-band emission region are observed. Maximum efficiency is achieved by additional heating of the core of the plasma to allow the optimal temperature to expand to a lower and more optically thin density. This leads to higher temperature plasma that emits less in-band light as compared to CO{sub 2} produced plasma sources for the same application.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a Gas Monitor Detector using a Cryogenic Radiometer for Measuring the Radiant Power of Extreme Ultraviolet Free Electron Laser at SPring-8

A gas monitor detector was calibrated to a cryogenic radiometer for measuring the radiant power of EUV-FEL (extreme ultraviolet free electron laser) at the wavelengths of 51 nm and 61 nm. The output signals of the gas monitor detector showed good linearity against the radiant power measured by the radiometer in the range from 6 {mu}W to 160 {mu}W. The calibration coefficients of the gas monitor detector are determined with the relative standard uncertainty of around 5 %.

43 PARTICLE ACCELERATORS↗

Transmission grating based extreme ultraviolet imaging spectrometer for time and space resolved impurity measurements

A free standing transmission grating based imaging spectrometer in the extreme ultraviolet range has been developed for the National Spherical Torus Experiment (NSTX). The spectrometer operates in a survey mode covering the approximate spectral range from 30 to 700 A and has a resolving capability of {delta}{lambda}/{lambda} on the order of 3%. Initial results from space resolved impurity measurements from NSTX are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma diagnostics for investigating extreme ultraviolet light sources

Plasma temperature and density diagnostics are crucial for lithographic applications of extreme ultraviolet light sources. One widely used technique employs line intensity ratios of successively charged ion states to determine the ion temperature (T{sub ionz}). This work comprises a detailed ''stress-test'' of the applied technique, where space and time resolved emission in laser-produced plasmas were studied, using a Nd:yttrium aluminum garnet laser pulse incident on an aluminum target in the 26.5-32.5 nm range. Detailed hydrodynamic simulations also investigate the dependency of ion temperature on electron density and the charge states for various line combinations (Al VI/V, Al VII/VI, Al VIII/VII, Al IX/VIII, and Al X/IX).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rare-earth plasma extreme ultraviolet sources at 6.5-6.7 nm

We have demonstrated a laser-produced plasma extreme ultraviolet source operating in the 6.5-6.7 nm region based on rare-earth targets of Gd and Tb coupled with a Mo/B{sub 4}C multilayer mirror. Multiply charged ions produce strong resonance emission lines, which combine to yield an intense unresolved transition array. The spectra of these resonant lines around 6.7 nm (in-band: 6.7 nm {+-}1%) suggest that the in-band emission increases with increased plasma volume by suppressing the plasma hydrodynamic expansion loss at an electron temperature of about 50 eV, resulting in maximized emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Localized ultraviolet photoresponse in single bent ZnO micro/nanowires

The localized ultraviolet photoresponse in single bent ZnO micro/nanowires bridging two Ohmic contacts has been investigated. The ZnO micro/nanowire has a higher photoresponse sensitivity of about 190% at the bent region (bending strain: about 4%) than that at the straight region (about 50%). The rise and decay time constants are almost the same in the straight and bent regions of the ZnO micro/nanowire. A possible mechanism has been proposed and discussed. The bent ZnO micro/nanowires could be potentially useful for fabricating the coupled piezoelectric and optoelectronic nanodevices.

36 MATERIALS SCIENCE↗

Deep-ultraviolet photodetectors from epitaxially grown Ni{sub x}Mg{sub 1-x}O

Deep-ultraviolet (DUV) photodetectors were fabricated from high quality Ni{sub x}Mg{sub 1-x}O epitaxially grown by plasma-assisted molecular beam epitaxy on an approximately lattice matched MgO <100> substrate. A mid-range Ni composition (x=0.54) Ni{sub x}Mg{sub 1-x}O film was grown for DUV ({lambda}{sub peak}<300 nm) photoresponse and the film was characterized by reflected high-energy electron diffraction, Rutherford backscattering spectroscopy, x-ray diffraction, and optical transmission measurements. Photoconductive detectors were then fabricated by deposition of symmetric interdigitated contacts (10 nm Pt/150 nm Au) with contact separations of 5, 10, and 15 {mu}m. The detectors exhibited peak responsivities in the DUV ({lambda}{sub peak{approx_equal}}250 nm) as high as 12 mA/W, low dark currents (I{sub dark}<25 nA), and DUV:visible rejection ratio of approximately 800:1.

36 MATERIALS SCIENCE↗