Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracking errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Joint Polar Satellite System (JPSS)-3 VIIRS Prelaunch Geometric Calibration and Characterization Status

The NASA/NOAA Visible Infrared Imaging Radiometer Suite (VIIRS) is a key instrument in the JPSS missions (SNPP, JPSS-1-4). Being part of the calibration and validation process, JPSS-3 VIIRS prelaunch geometric performance assessment focuses on the sensor’s spatial response, band-to-band co-registration (BBR), and pointing knowledge. In general, JPSS-3 VIIRS’ prelaunch geometric performance is very good, and consistent with SNPP and JPSS-1-2 VIIRS sensors. This paper highlights some specific key findings from the JPSS-3 VIIRS’ prelaunch tests. We first show that with timing adjustments, JPSS-3 VIIRS scan BBR error between VisNIR and S/M/LWIR bands has been reduced from 0.12/0.03 M sampling intervals to 0.005/0.002 M sampling intervals, respectively. Focal Plane Assembly (FPA) rotations have been changed from 0.1 degree to 0.04 degree in VisVIR, from 0.18 degree to 0.09 degree in S/MWIR, and 0.16 degree to 0.08 degree in LWIR. Another finding from the prelaunch test is that JPSS-3 VIIRS has relatively large band-to-band co-registration errors between VisNIR and S/M/LWIR bands in the track direction. This BBR mis-registration increases when aft‐optics assembly (AOA) temperature decreases. The BBR mis-registration is about 0.10 M sampling intervals between VisNIR and S/MWIR bands, and 0.08 M sampling intervals between VisNIR and LWIR bands. By comparison, the track BBR offset in JPSS-2 is less than 0.02 M sampling intervals between VisNIR and S/M/LWIR bands. We also notice that the unsymmetrical Day Night Band (DNB) scan-direction Line Spread Function (LSF) of JPSS-2 VIIRS at different gain stages and aggregation modes have been corrected in J3 VIIRS.

VIIRS↗

A Semi-Empirical Scheme for Bathymetric Mapping in Shallow Water by ICESat-2 and Sentinel-2: A Case Study in the South China Sea

To derive shallow water bathymetry for coastal areas, a common approach is to deploy a scanning airborne bathymetric light detection and ranging (LiDAR) system or a shipborne echosounder for ground surveys. However, recent advancements in satellite remote sensing, including the Ice, Cloud and land Elevation Satellite-2 (ICESat-2) offer new tools for generating satellite derived bathymetry (SDB). The key payload onboard ICESat-2 is the Advanced Topographic Laser Altimeter System (ATLAS), a micro-pulse, photon-counting LiDAR system, simultaneously emitting six separate 532 nm beams at 10 kHz pulse rate. However, despite its high resolution, the major limitation for bathymetry is that ICESat-2 only provides along-track height profiles, leaving observation gaps between the parallel ground tracks. Merging ICESat-2 observations with optical multispectral imagery, as demonstrated herein, provides an effective solution for deriving a full scene of water depth in light of the spectral attenuation behavior. This study aims to combine ICESat-2 and Sentinel-2 optical data to derive shallow water bathymetry (depth <20 m) at six islands and reefs in the South China Sea. ICESat-2 ATL03 point clouds of georeferenced photons are first filtered to determine the seafloor elevation along the ground track. Results indicate a root-mean-square error (RMSE) of 0.26–0.61 m as compared with independent observations from an airborne LiDAR campaign. Next, three semi-empirical functions, namely the Modified Linear/Polynomial/Exponential Ratio Models with its kernel formed by the log ratio between Sentinel-2′s green and blue bands, are used to fit the spectral data with ICESat-2 height profiles. After water depth mapping using the trained model, independent ICESat-2 point clouds are used to validate the Sentinel-2 derived bathymetry. The RMSE values of the three models using the weighted average of multiple images for these six islands are within 0.50–0.90 m in 0–15 m deep. We also demonstrate that a synthesis of satellite laser altimetry and optical remote sensing can produce SDB results that potentially meet the requirement of category C in Zones of Confidence (ZOC) of the Electronic Navigational Chart (ENC) in 0–8 m deep. It is foreseen that ICESat-2 will be a helpful tool for mapping coastal and shallow waters around the world especially where bathymetric data are unavailable.

Coastal Bathymetry↗

Alternative Attitude Commanding and Control for Precise Spacecraft Landing

A report proposes an alternative method of control for precision landing on a remote planet. In the traditional method, the attitude of a spacecraft is required to track a commanded translational acceleration vector, which is generated at each time step by solving a two-point boundary value problem. No requirement of continuity is imposed on the acceleration. The translational acceleration does not necessarily vary smoothly. Tracking of a non-smooth acceleration causes the vehicle attitude to exhibit undesirable transients and poor pointing stability behavior. In the alternative method, the two-point boundary value problem is not solved at each time step. A smooth reference position profile is computed. The profile is recomputed only when the control errors get sufficiently large. The nominal attitude is still required to track the smooth reference acceleration command. A steering logic is proposed that controls the position and velocity errors about the reference profile by perturbing the attitude slightly about the nominal attitude. The overall pointing behavior is therefore smooth, greatly reducing the degree of pointing instability.

Singh, Gurkirpal↗

Implication of microdosimetry in estimation of radiation quality in space environment

Errors introduced using a tissue equivalent proportional counter to estimate radiation quality of an arbitrary ion field as related to space radiations are examined. This is accomplished by using a generalized analytic model to calculate the effect of energy loss straggling, track structure, and pathlength distribution on the microdosimetric distribution. The error can be as large as a factor of two, but no systematic trend could be found.

NASA Discipline Radiation Health↗

Reconciliation of asynchronous satellite-based $\mathrm{NO_2}$ and $\mathrm{XCO_2}$ enhancements with mesoscale modeling over two urban landscapes

Fossil fuel carbon dioxide (CO 2ff ), the main driver of global warming and climate change, is often co-emitted with nitrogen oxides (NO x ) and precursors to ground-level ozone from anthropogenic sources like power plants or vehicles. In urban and suburban areas, satellite-based NO 2 can be used as a proxy to track the emissions of CO 2ff . Because of NO 2 ’s shorter lifetime, urban NO 2 plumes are more distinguishable from backgrounds and more sensitive to variations in emissions. However, the combination of these two gases is limited by the asynchrony among NO 2 and CO 2 monitoring satellites. We used CO 2ff simulated by the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) model to reconcile the tropospheric NO 2 vertical column density (VCD) from the Tropospheric Monitoring Instrument (TROPOMI) and column-averaged dry-air mole fractions of carbon dioxide enhancements (ΔXCO 2 ) from Orbiting Carbon Observatory 3 (OCO-3) Snapshot Area Maps (SAMs) over a multicity area, Washington D.C.-Baltimore (DC-Balt), and a basin city, Mexico City. NO 2 /CO 2ff ratios over DC-Balt are smaller than Mexico City, indicative of stricter emission restrictions, a more combustion-efficient vehicle fleet, and higher combustion efficiency due to lower altitude in DC-Balt. For single-track cases, the spatial correlations between NO 2 and ΔXCO 2 over Mexico City are stronger than DC-Balt because the NO 2 and CO 2 are mostly trapped in the valley of Mexico City, while DC-Balt is severely affected by distant sources (i.e., US East Coast cities). Using multi-track averaging, spatial correlation coefficients increase with the number of days used for averaging. The correlations reached a maximum when averaging >12 continuous images for DC-Balt and > 10 continuous images for Mexico City. This finding indicates that multi-track averaging using modeled CO 2ff as a proxy is helpful to filter the noise in single-track images, to cancel the interference from distant sources, and to magnify correlations between NO 2 and CO 2ff . Mexico City showed stronger spatial correlations but weaker temporal correlations than DC-Balt due to biomass burning hot spots and large transport errors caused by the trapping effects of the surrounding mountains. Tracking the 20-day moving average of CO 2ff emissions using TROPOMI NO 2 seems technically feasible, considering the relationship between correlation coefficients and the number of available satellite images.

54 ENVIRONMENTAL SCIENCES↗

Performance of the Dsa's Subcarrier Demodulation Digital Loop

The subcarrier demodulation digital loop is part of the baseband assembly. The subcarrier demodulator is a fourth-order Costas-type loop corresponding to a type 2 analog loop in terms of steady state response. The expected value and the variance of the error signal are determined as functions of the input SNR. A Nyquist sampling rate of the input signal is assumed. From the integro-difference equations a mixed s/z domain block diagram is obtained. From the loop's transfer function a set of gains for the loop filter is obtained. Also, a set of state equations is presented for future reference. Finally, the noise-equivalent bandwidths are calculated for normalized computation times of 0, 0.25 and 0.5. The subcarrier demodulator analyzed tracks a parabolic phase input with finite steady state error. Since at each update instant the loop gains are adjusted to compensate for the variations in SNR of the input signal, the noise-equivalent bandwidth is maintained constant.

Simon, M. K.↗

Spatial and rotational quality assurance of 6DOF patient tracking systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations. In this work, the authors develop a novel technique to evaluate the 6 degree of freedom 6(DOF) (translations and rotations) performance of external motion tracking systems. The authors apply this methodology to an infrared marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to perform motions with sub-millimeter and subdegree accuracy in a 6DOF workspace. An infrared marker tracking system was first used to validate a calibration algorithm which associates the motion phantom coordinate frame to the camera frame. The 6DOF positions of the mobile robotic system in this space were then tracked and recorded independently by an optical surface tracking system after a cranial phantom was rigidly fixed to the moveable platform of the robotic stage. The calibration methodology was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20 × 20 × 16 mm and 5° × 5° × 5° workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the infrared (IR) marker tracking system to have maximal root-mean square error (RMSE) values of 0.18, 0.25, 0.07 mm, 0.05°, 0.05°, and 0.09° in left–right (LR), superior–inferior (SI), anterior–posterior (AP), pitch, roll, and yaw, respectively, comparing the intended 6DOF position and the measured position by the IR camera. Similarly, the 6DOF RSME discrepancy for the HD optical surface tracker yielded maximal values of 0.46, 0.60, 0.54 mm, 0.06°, 0.11°, and 0.08° in LR, SI, AP, pitch, roll, and yaw, respectively, over the same 6DOF evaluative workspace. An earlier generation 3D optical surface tracking unit was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.69, 0.74, 0.47 mm, 0.28°, 0.19°, and 0.18°, in LR, SI, AP, pitch, roll, and yaw, respectively, in the same 6DOF evaluation space. Conclusions: The proposed technique was found to be effective at evaluating the performance of 6DOF patient tracking systems. All observed optical tracking systems were found to exhibit tracking capabilities at the sub-millimeter and subdegree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗

Multipath errors in range rate measurement by a TDRS/VHF - GRARR

Range rate errors due to multipath reflection are calculated for a tracking and data relay satellite system using the VHF Goddard range and range rate (GRARR) system. At VHF the reflection is primarily specular, and the strength of the multipath relative to the direct path can be modeled in terms of the geometry and the surface characteristics, specifically the root-mean-square (rms) ocean wave height. The uplink and downlink multipath introduces phase jitter on the GRARR carrier and subcarrier. The derivation of these effects is reviewed leading to an expression for the rms range rate error. The derivation assumed the worst-case orbital configurations in which there was very little relative specular Doppler. This means that the specular multipath interference was not attenuated by the carrier and subcarrier PLL transfer functions. Curves of range rate error are presented as a function of grazing angle with wave height 0.3 to 0.7 meters and spacecraft altitude 100 to 700 miles as parameters.

Sohn, S. J.↗

TH-CD-207A-03: A Surface Deformation Driven Respiratory Model for Organ Motion Tracking in Lung Cancer Radiotherapy

Purpose: To propose and validate a novel real-time surface-mesh-based internal organ-external surface motion and deformation tracking method for lung cancer radiotherapy. Methods: Deformation vector fields (DVFs) which characterizes the internal and external motion are obtained by registering the internal organ and tumor contours and external surface meshes to a reference phase in the 4D CT images using a recent developed local topology preserved non-rigid point matching algorithm (TOP). A composite matrix is constructed by combing the estimated internal and external DVFs. Principle component analysis (PCA) is then applied on the composite matrix to extract principal motion characteristics and finally yield the respiratory motion model parameters which correlates the internal and external motion and deformation. The accuracy of the respiratory motion model is evaluated using a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and three lung cancer cases. The center of mass (COM) difference is used to measure the tumor motion tracking accuracy, and the Dice’s coefficient (DC), percent error (PE) and Housdourf’s distance (HD) are used to measure the agreement between the predicted and ground truth tumor shape. Results: The mean COM is 0.84±0.49mm and 0.50±0.47mm for the phantom and patient data respectively. The mean DC, PE and HD are 0.93±0.01, 0.13±0.03 and 1.24±0.34 voxels for the phantom, and 0.91±0.04, 0.17±0.07 and 3.93±2.12 voxels for the three lung cancer patients, respectively. Conclusions: We have proposed and validate a real-time surface-mesh-based organ motion and deformation tracking method with an internal-external motion modeling. The preliminary results conducted on a synthetic 4D NCAT phantom and 4D CT images from three lung cancer cases show that the proposed method is reliable and accurate in tracking both the tumor motion trajectory and deformation, which can serve as a potential tool for real-time organ motion and deformation monitoring in lung cancer radiotherapy. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).

60 APPLIED LIFE SCIENCES↗

Advanced Tritium Process Analytics and Optimization via a Digital Twin, SRNL-TR-2023-00550

Improving the process knowledge and understanding of TCAP can be achieved by incorporating advanced tools. This project addresses “Advanced analytics for modeling, forecasting, & optimization of the tritium refinement process” and is being applied to the TCAP process. The value of digitization and advanced analytics for TCAP data are tracking of gas mixtures & inventories is presently a manual effort that is rather cumbersome. Incorporating some automation into the data capture will reduce errors and storing data in an accessible database that can be used for tracking as well as process improvements. In addition, the database approach will enable longer term history to be maintained rather than the current practice of deleting data after six months. The digitized and automated data will allow for models to be developed for the process and will enable the forecasting and optimization.

Korinko, Paul S.↗

Tracking Object Existence From an Autonomous Patrol Vehicle

An autonomous vehicle patrols a large region, during which an algorithm receives measurements of detected potential objects within its sensor range. The goal of the algorithm is to track all objects in the region over time. This problem differs from traditional multi-target tracking scenarios because the region of interest is much larger than the sensor range and relies on the movement of the sensor through this region for coverage. The goal is to know whether anything has changed between visits to the same location. In particular, two kinds of alert conditions must be detected: (1) a previously detected object has disappeared and (2) a new object has appeared in a location already checked. For the time an object is within sensor range, the object can be assumed to remain stationary, changing position only between visits. The problem is difficult because the upstream object detection processing is likely to make many errors, resulting in heavy clutter (false positives) and missed detections (false negatives), and because only noisy, bearings-only measurements are available. This work has three main goals: (1) Associate incoming measurements with known objects or mark them as new objects or false positives, as appropriate. For this, a multiple hypothesis tracker was adapted to this scenario. (2) Localize the objects using multiple bearings-only measurements to provide estimates of global position (e.g., latitude and longitude). A nonlinear Kalman filter extension provides these 2D position estimates using the 1D measurements. (3) Calculate the probability that a suspected object truly exists (in the estimated position), and determine whether alert conditions have been triggered (for new objects or disappeared objects). The concept of a probability of existence was created, and a new Bayesian method for updating this probability at each time step was developed. A probabilistic multiple hypothesis approach is chosen because of its superiority in handling the uncertainty arising from errors in sensors and upstream processes. However, traditional target tracking methods typically assume a stationary detection volume of interest, whereas in this case, one must make adjustments for being able to see only a small portion of the region of interest and understand when an alert situation has occurred. To track object existence inside and outside the vehicle's sensor range, a probability of existence was defined for each hypothesized object, and this value was updated at every time step in a Bayesian manner based on expected characteristics of the sensor and object and whether that object has been detected in the most recent time step. Then, this value feeds into a sequential probability ratio test (SPRT) to determine the status of the object (suspected, confirmed, or deleted). Alerts are sent upon selected status transitions. Additionally, in order to track objects that move in and out of sensor range and update the probability of existence appropriately a variable probability detection has been defined and the hypothesis probability equations have been re-derived to accommodate this change. Unsupervised object tracking is a pervasive issue in automated perception systems. This work could apply to any mobile platform (ground vehicle, sea vessel, air vehicle, or orbiter) that intermittently revisits regions of interest and needs to determine whether anything interesting has changed.

Wolf, Michael↗

Tracking Radiometer Calibration Stability Using Three-Point Onboard Calibration

Absolute calibration of radiometers is implemented onboard using one hot and one cold external calibration targets. However, two-point calibration methods are unable to differentiate calibration drifts and associated errors from fluctuations in receiver gain and offset. This paper investigates the use of onboard three-point calibration algorithm for microwave radiometers to track calibration drifts and characterize associated errors in Earth and Space measurements of the radiometer.

Calibration↗

Temporal regularization of ultrasound-based liver motion estimation for image-guided radiation therapy

Purpose: Ultrasound-based motion estimation is an expanding subfield of image-guided radiation therapy. Although ultrasound can detect tissue motion that is a fraction of a millimeter, its accuracy is variable. For controlling linear accelerator tracking and gating, ultrasound motion estimates must remain highly accurate throughout the imaging sequence. This study presents a temporal regularization method for correlation-based template matching which aims to improve the accuracy of motion estimates. Methods: Liver ultrasound sequences (15–23 Hz imaging rate, 2.5–5.5 min length) from ten healthy volunteers under free breathing were used. Anatomical features (blood vessels) in each sequence were manually annotated for comparison with normalized cross-correlation based template matching. Five sequences from a Siemens Acuson™ scanner were used for algorithm development (training set). Results from incremental tracking (IT) were compared with a temporal regularization method, which included a highly specific similarity metric and state observer, known as the α–β filter/similarity threshold (ABST). A further five sequences from an Elekta Clarity™ system were used for validation, without alteration of the tracking algorithm (validation set). Results: Overall, the ABST method produced marked improvements in vessel tracking accuracy. For the training set, the mean and 95th percentile (95%) errors (defined as the difference from manual annotations) were 1.6 and 1.4 mm, respectively (compared to 6.2 and 9.1 mm, respectively, for IT). For each sequence, the use of the state observer leads to improvement in the 95% error. For the validation set, the mean and 95% errors for the ABST method were 0.8 and 1.5 mm, respectively. Conclusions: Ultrasound-based motion estimation has potential to monitor liver translation over long time periods with high accuracy. Nonrigid motion (strain) and the quality of the ultrasound data are likely to have an impact on tracking performance. A future study will investigate spatial uniformity of motion and its effect on the motion estimation errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Validation of Pulse Phase Tracking for X-Ray Pulsar Based

Pulsars are a form of variable celestial source that have shown to be usable as aids for autonomous, deep space navigation. Particularly those sources emitting in the X-ray band are ideal for navigation due to smaller detector sizes. In this paper X-ray photons arriving from a pulsar are modeled as a non-homogeneous Poisson process. The method of pulse phase tracking is then investigated as a technique to measure the radial distance traveled by a spacecraft over an observation interval. A maximum-likelihood phase estimator (MLE) is used for the case where the observed frequency signal is constant. For the varying signal frequency case, an algorithm is used in which the observation window is broken up into smaller blocks over which an MLE is used. The outputs of this phase estimation process were then looped through a digital phase-locked loop (DPLL) in order to reduce the errors and produce estimates of the doppler frequency. These phase tracking algorithms were tested both in a computer simulation environment and using the NASA Goddard Space flight Center X-ray Navigation Laboratory Testbed (GXLT). This provided an experimental validation with photons being emitted by a modulated X-ray source and detected by a silicon-drift detector. Models of the Crab pulsar and the pulsar B1821-24 were used in order to generate test scenarios. Three different simulated detector trajectories were used to be tracked by the phase tracking algorithm: a stationary case, one with constant velocity, and one with constant acceleration. All three were performed in one-dimension along the line of sight to the pulsar. The first two had a constant signal frequency and the third had a time varying frequency. All of the constant frequency cases were processed using the MLE, and it was shown that they tracked the initial phase within 0.15% for the simulations and 2.5% in the experiments, based on an average of ten runs. The MLE-DPLL cascade version of the phase tracking algorithm was used in the varying frequency case. This resulted in tracking of the phase and frequency by the DPLL outputs in both the simulation and experimental environments. The crab pulsar was experimentally tested with a trajectory with a higher acceleration. In this case the phase error tended toward zero as the observation extended to 250 seconds and the doppler frequency error tended to zero in under 100 seconds.

Experimental↗

SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.

60 APPLIED LIFE SCIENCES↗

Simplified formula for mean cycle-slip time of phase-locked loops with steady-state phase error.

Previous work shows that the mean time from lock to a slipped cycle of a phase-locked loop is given by a certain double integral. Accurate numerical evaluation of this formula for the second-order loop is extremely vexing because the difference between exponentially large quantities is involved. The presented article demonstrates a method in which a much-reduced precision program can be used to obtain the mean first-cycle slip time for a loop of arbitrary degree tracking at a specified SNR and steady-state phase error. It also presents a simple approximate formula that is asymptotically tight at higher loop SNR.

Tausworthe, R. C.↗

SU-E-J-135: An Investigation of Ultrasound Imaging for 3D Intra-Fraction Prostate Motion Estimation

Purpose: This study investigates the use of a mechanically swept 3D ultrasound (US) probe to estimate intra-fraction motion of the prostate during radiation therapy using an US phantom and simulated transperineal imaging. Methods: A 3D motion platform was used to translate an US speckle phantom while simulating transperineal US imaging. Motion patterns for five representative types of prostate motion, generated from patient data previously acquired with a Calypso system, were using to move the phantom in 3D. The phantom was also implanted with fiducial markers and subsequently tracked using the CyberKnife kV x-ray system for comparison. A normalised cross correlation block matching algorithm was used to track speckle patterns in 3D and 2D US data. Motion estimation results were compared with known phantom translations. Results: Transperineal 3D US could track superior-inferior (axial) and anterior-posterior (lateral) motion to better than 0.8 mm root-mean-square error (RMSE) at a volume rate of 1.7 Hz (comparable with kV x-ray tracking RMSE). Motion estimation accuracy was poorest along the US probe's swept axis (right-left; RL; RMSE < 4.2 mm) but simple regularisation methods could be used to improve RMSE (< 2 mm). 2D US was found to be feasible for slowly varying motion (RMSE < 0.5 mm). 3D US could also allow accurate radiation beam gating with displacement thresholds of 2 mm and 5 mm exhibiting a RMSE of less than 0.5 mm. Conclusion: 2D and 3D US speckle tracking is feasible for prostate motion estimation during radiation delivery. Since RL prostate motion is small in magnitude and frequency, 2D or a hybrid (2D/3D) US imaging approach which also accounts for potential prostate rotations could be used. Regularisation methods could be used to ensure the accuracy of tracking data, making US a feasible approach for gating or tracking in standard or hypo-fractionated prostate treatments.

60 APPLIED LIFE SCIENCES↗