Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Limits on monopole fluxes from KFG experiment

The nucleon decay experiment at KGF at a depth of 2.3 Km is eminently suited for the search of Grand Unified theory (GUT) monopoles, whose velocities at the present epoch are predicted to be around 0.001C. At this depth the cosmic ray background is at a level 2/day in the detector of size 4m x 6m x 3.7m and one can look for monopoles traversing the detector in all directions, using three methods, i.e., (1) dE/dx (ionization); (2) time of flight and (3) catalysis of nucleon decay. The detector is composed of 34 layers of proportional counters arranged in horizontal planes one above the other in an orthogonal maxtrix. Each of the 1594 counters are instrumented to measure ionization in the gas (90% Argon + 10% Methane) as well as the time of arrival of particles.

Krishnaswamy, M. R.↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of an impulsive solar X-ray burst from a coronal source

Observations of the spatial, spectral, and temporal structure of an impulsive hard X-ray source in a behind-the-limb solar flare have been made with high-time-resolution hard X-ray detectors aboard two spacecraft, the International Sun Earth Explorer 3 (ISEE 3) and the Pioneer Venus Orbiter (PVO), which were separated in heliographic longitude by about 12.5 deg. The principal findings are that (1) the coronal part of the X-ray source is about 600 times less intense than the lower-altitude part of the source; and (2) the coronal X-ray observations are consistent with a power-law electron spectrum which extends down to about 5 keV.

Kane, S. R.↗

Measurement of the pion charge exchange differential cross section on Argon with the ProtoDUNE-SP detector

The Deep Underground Neutrino Experiment (DUNE) utilizes Liquid Argon Time Projection Chamber (LArTPC) technology in its pursuit of uncovering the origins of matter. As a crucial prototype for the DUNE far detector (FD) module, ProtoDUNE-SP at CERN Neutrino Platform Facility employs a hadron test beam with a momentum range of 0.3 to 7 GeV/c to study the detector response to particles that could be produced in the neutrino interactions at the DUNE FD. Furthermore, ProtoDUNE-SP is dedicated to testing event reconstruction and performing detector calibration under controlled conditions. Neutral pion reconstruction performance is an important benchmark of the calorimetric and tracking capability of LArTPC, and understanding neutral pion in LArTPC is crucial to characterize backgrounds to oscillation measurements and rare searches. To improve neutral pion reconstruction in LArTPC, a kinematic fitting algorithm is developed, achieving a 12% resolution in neutral pion energy in ProtoDUNE-SP. This enhancement enables the first measurements of the pion-argon charge exchange differential cross-section. By comparing these results with the current model, valuable constraints can be made to improve generator simulations in the future DUNE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Focal Plane Alignment Utilizing Optical CMM

In many applications, an optical detector has to be located relative to mechanical reference points. One solution is to specify stringent requirements on (1) mounting the optical detector relative to the chip carrier, (2) soldering the chip carrier onto the printed circuit board (PCB), and (3) installing the PCB to the mechanical structure of the subsystem. Figure 1 shows a sketch of an optical detector mounted relative to mechanical reference with high positional accuracy. The optical detector is typically a fragile wafer that cannot be physically touched by any measurement tool. An optical coordinate measuring machine (CMM) can be used to position optical detectors relative to mechanical reference points. This approach will eliminate all requirements on positional tolerances. The only requirement is that the PCB is manufactured with oversized holes. An exaggerated sketch of this situation is shown in Figure 2. The sketch shows very loose tolerances on mounting the optical detector in the chip carrier, loose tolerance on soldering the chip carrier to the PCB, and finally large tolerance on where the mounting screws are located. The PCB is held with large screws and oversized holes. The PCB is mounted loosely so it can move freely around. The optical CMM measures the mechanical reference points. Based on these measurements, the required positions of the optical detector corners can be calculated. The optical CMM is commanded to go to the position where one detector corner is supposed to be. This is indicated with the cross-hairs in Figure 2(a). This figure is representative of the image of the optical CMM monitor. Using a suitable tapping tool, the PCB is manually tapped around until the corner of the optical detector is at the crosshairs of the optical CMM. The CMM is commanded to another corner, and the process is repeated a number of times until all corners of the optical detector are within a distance of 10 to 30 microns of the required position. The situation is sketched in Figure 2(b) (the figure also shows the tapping tool and where to tap). At this point the fasteners for the PCB are torqued slightly so the PCB can still move. The PCB location is adjusted again with the tapping tool. This process is repeated 3 to 4 times until the final torque is achieved. The oversized mounting holes are then filled with a liquid bonding agent to secure the board in position (not shown in the sketch). A 10- to 30-micron mounting accuracy has been achieved utilizing this method..

Liebe, Carl Christian↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Low-latency NuMI Trigger for the CHIPS-5 Neutrino Detector

The CHIPS R&D project aims to develop affordable water Cherenkov detectors for large-scale underwater installations. In 2019, a 5kt prototype detector CHIPS-5 was deployed in northern Minnesota to study neutrinos generated by the nearby NuMI beam. This contribution presents a dedicated low-latency time distribution system for CHIPS-5 that delivers timing signals from the Fermilab accelerator to the detector with sub-nanosecond precision. Exploiting existing NOvA infrastructure, the time distribution system achieves this only with open-source software and conventional network elements. In a time-of-flight study, the presented system has reliably offered a time budget of $610 \pm 330\text{ ms}$ for on-site triggering. This permits advanced analysis in real-time as well as a novel hardware-assisted active triggering mode, which reduces DAQ computing load and network bandwidth outside triggered time windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-neutrino double electron capture of 124 Xe in the first LUX-ZEPLIN exposure

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of 124Xe through the process of two-neutrino double electron capture, utilizing a 1.39 kg × yr isotopic exposure from the first LZ science run. A half-life of $T$$^{2v2EC}_{1/2}$ = (1.09 ± 0.14 stat ± 0.05 sys ) x 10 22 yr is observed with a statistical significance of 8.3σ, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the 1.4σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of low energy electrons

Simultaneous observations of low energy electrons in the plasma sheet and in the auroral zone were analyzed. Data from the MIT plasma experiment on the OGO-3 satellite and from the Lockheed experiment on the OV1-18 satellite were processed and compared. The OV1-18 carried thirteen magnetic electron spectrometers designed to measure the intensity, angular, and energy distributions of the auroral electrons and protons in the energy range below 50 keV. Two computer programs were developed for reduction of the OV1-18 data. One program computed the various plasma properties at one second intervals as a function of Universal Time and pitch angle; the other program produced survey plots showing the outputs of the various detectors on the satellite as a function of time on a scale of approximately 100 seconds per cm. The OV1-18 data exhibit the high degree of variability associated with substorm controlled phenomena.

Sharp, R. D.↗

A Tool Kit for Generating Simulated Radiation Measurements for Advanced Reactor Safeguards and Security

A tool kit was developed to simulate and analyze passive radiation measurements of molten salt reactor (MSR) operations to support development of nuclear safeguards approaches for this emerging reactor technology. A Transient Simulation Framework of Reconfigurable Modules (TRANSFORM) multiphysics simulation of an MSR produces time-dependent isotopic inventories at user-selected locations within the model. The tool kit implements the Gamma Detector Response and Analysis Software (GADRAS) application programming interface to inject the TRANSFORM isotopic inventories extracted/processed by a Python pipeline into GADRAS models of user-defined geometries. The TRANSFORM inventories are the source terms used to obtain synthetic measurements from GADRAS-defined detectors. The speed of TRANSFORM and GADRAS simulations enables surveying the large design space of MSRs (e.g., fuel type, fuel salt composition, number of loops) and the plethora of measurements (e.g., location, detector type, and collimation) within the reactor. This has enabled timely assessment of the various measurement locations and detectors to identify the most effective and efficient safeguards approach for a specific MSR design. Lastly, the tool kit also simulates extracted samples that can be aged to a desired dose, enabling stakeholders to optimize a measurement plan to use sample analysis as an element within a broader material accountancy plan.

Westphal, Greg↗

Method and apparatus for fiber optic multiple scattering suppression

The instant invention provides a method and apparatus for use in laser induced dynamic light scattering which attenuates the multiple scattering component in favor of the single scattering component. The preferred apparatus utilizes two light detectors that are spatially and/or angularly separated and which simultaneously record the speckle pattern from a single sample. The recorded patterns from the two detectors are then cross correlated in time to produce one point on a composite single/multiple scattering function curve. By collecting and analyzing cross correlation measurements that have been taken at a plurality of different spatial/angular positions, the signal representative of single scattering may be differentiated from the signal representative of multiple scattering, and a near optimum detector separation angle for use in taking future measurements may be determined.

Ackerson, Bruce J.↗

Machine learning assisted unfolding for neutrino cross-section measurements with the OmniFold technique

The choice of unfolding method for a cross-section measurement is tightly coupled to the model dependence of the efficiency correction and the overall impact of cross-section modeling uncertainties in the analysis. A key issue is the dimensionality used in unfolding, as the kinematics of all outgoing particles in an event typically affect the reconstruction performance in a neutrino detector. OmniFold is an unfolding method that iteratively reweights a simulated dataset, using machine learning to utilize arbitrarily high-dimensional information, that has previously been applied to proton-proton and proton-electron datasets. This paper demonstrates OmniFold’s application to a neutrino cross-section measurement for the first time using a public T2K near detector simulated dataset, comparing its performance with traditional approaches using a mock data study.

Machine learning↗

Evaluating Handheld X-Ray Fluorescence (XRF) Technology in Planetary Exploration: Demonstrating Instrument Stability and Understanding Analytical Constraints and Limits for Basaltic Rocks

While large-footprint X-ray fluorescence (XRF) instruments are reliable providers of elemental information about geologic samples, handheld XRF instruments are currently being developed that enable the collection of geochemical data in the field in short time periods (approx.60 seconds) [1]. These detectors are lightweight (1.3kg) and can provide elemental abundances of major rock forming elements heavier than Na. While handheld XRF detectors were originally developed for use in mining, we are working with commercially available instruments as prototypes to explore how portable XRF technology may enable planetary field science [2,3,4]. If an astronaut or robotic explorer visited another planetary surface, the ability to obtain and evaluate geochemical data in real-time would be invaluable, especially in the high-grading of samples to determine which should be returned to Earth. We present our results on the evaluation of handheld XRF technology as a geochemical tool in the context of planetary exploration.

Young, K. E.↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS

We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.

Aitken, Branden [Victoria U.]↗

Indium antimonide infrared CCD linear imaging arrays with on-chip preprocessing

A description is presented of the fabrication of a new InSb CCD chip based on an improved process which eliminates the limitations inherent with the earlier techniques. This process includes planar junction formation and an aluminum and SiO2 material system which is amenable to state-of-the-art chemical and plasma delineation techniques. Further, the new chip integrates for the first time in monolithic format InSb IR detectors with an InSb CCD. The reported experiments represent the first operation of an InSb infrared CCD array. In addition to fuller characterization of the 20-element charge-coupled infrared imaging device, several factors which influence device performance are currently being addressed. These include surface state density, the CCD output circuit, and storage time (dark current).

Thom, R. D.↗