Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Dynamic Power Convertor Validation and Verification Thermal Analysis

NASA Glenn Research Center is preparing to perform experimental testing on various Stirling Convertors in the < 100-watt range. Prior to testing, a variety of computational simulations are being performed with the convertors-only (in isolation), and with the convertors equipped with an anticipated insulation and heating package that will be part of experimental test article. The goal is to develop a calculation methodology that will assist in predicting the convertor parasitic losses as well as estimating convertor efficiency. Three different cold-end temperatures will be explored on two different convertors, and the contribution of radiation within the heater head itself was included.

Stirling↗

Dynamic Power Convertor Validation and Verification Thermal Analysis

NASA Glenn Research Center is preparing to perform experimental testing on various Stirling Convertors in the < 100-watt range. Prior to testing, a variety of computational simulations are being performed with the convertors-only (in isolation), and with the convertors equipped with an anticipated insulation and heating package that will be part of experimental test article. The goal is to develop a calculation methodology that will assist in predicting the convertor parasitic losses as well as estimating convertor efficiency. Three different cold-end temperatures will be explored on two different convertors, and the contribution of radiation within the heater head itself was included.

Stirling↗

Solid electrolyte oxygen regeneration system

A program to design, develop, fabricate and assemble a one-man, self-contained, solid electrolyte oxygen regeneration system (SX-1) incorporating solid electrolyte electrolyzer drums was completed. The SX-1 is a preprototype engineering model designed to produce 0.952 kg (2.1 lb)/day of breathable oxygen (O2) from the electrolysis of metabolic carbon dioxide (CO2) and water vapor. The CO2 supply rate was established based on the metabolic CO2 generation rate for one man of 0.998 kg (2.2 lb)/day. The water supply rate (0.254 kg (0.56 lb)/day) was designed to be sufficient to make up the difference between the 0.952 kg (2.1 lb)/day O2 generation specification and the O2 available through CO2 electrolysis, 0.726 kg (1.6 lb)/day. The SX-1 was successfully designed, fabricated and assembled. Design verification tests (DVT) or the CO Disproportionators, H2 separators, control instrumentation, monitor instrumentation, water feed mechanism were successfully completed. The erratic occurrence of electrolyzer drum leakage prevented the completion of the CO2 electrolyzer module and water electrolyzer module DVT's and also prevented the performance of SX-1 integrated testing. Further development work is required to improve the solid electrolyte cell high temperature seals.

Shumar, J. W.↗

Investigation of turbulent diffusion in the extreme lower atmosphere

Turbulent diffusion in the extreme lower layer of the atmosphere (up to 5 m) has been investigated. Turbulent flow was simulated under dry, stable and calm conditions by means of a 3.04 m diameter fan installed at a field site situated on flat grassland. The ambient wind was continuously monitored by means of a cup anemometer placed outside the wake, and the temperature distribution was measured by four thermometers placed on an 18 m tower, also outside the wake. Balloons and red smoke were used to visualize the wake flow and investigate the predominant sizes of turbulent eddies and their streamwise behavior. The mean and turbulent velocities along the turbulence line were measured using an array of hot-wire anomometers. Results provide substantial verification of a recently proposed model (Koper and Sadeh, 1975; Koper et al., 1978) relating the Lagrangian to the Eulerian turbulent velocity autocorrelation. In this model the Lagrangian autocorrelation is given by a domain integral over a set of ordinary Eulerian autocorrelations acquired simultaneously at all points within the flow field in question, which is viewed as a turbulence 'box'.

Koper, C. A., Jr.↗

FOSSIL—Finding Our Cosmic Roots

FOSSIL (Fragments from the Origins of the Solar System and our Interstellar Locale) is a concept to explore the largest solar system object visible to the unaided eye—the zodiacal cloud. The cloud’s many dust particles are each a tiny time capsule from a comet or asteroid. The FOSSIL concept is for the in situ compositional analysis of interplanetary dust particles, and also of the particles passing through the solar system from interstellar space. By measuring the zodiacal and interstellar particles’ velocity vectors and compositions, the approach resolves fundamental questions about the solar system’s origins. The FOSSIL concept is to: (1) Discover whether today’s local interstellar dust matches the composition of the feedstock from which the solar system formed; (2) Determine whether comets’ fine-grained component preserves unprocessed pre-solar dust or shows signs of processing in the early solar system; and (3) Learn whether comets’ and asteroids’ organic material share a common source or formed from distinct reservoirs. The FOSSIL concept is based on the use of a Dust Telescope (DT) with the capability to measure the composition and the velocity vector of dust particles to unambiguously separate interstellar from interplanetary particles, and identify a subset of zodiacal particles that are exclusively cometary. In the DT, particles pass through the trajectory sensor unharmed and impact a target plate, where they are vaporized and partially ionized. The ions are electrostatically focused onto a detector where the time-of-flight mass spectrum is recorded, enabling measurement of the composition of the interstellar solids, detection of cometary minerals altered by high temperatures or exposure to liquid water in the early solar system, and the characterization of the organic materials from the comets and asteroids that are still being delivered to the Earth today. FOSSIL’s objectives crosscut several disciplines with planetary science. Astrophysics interests lie in understanding interstellar solar matter and the only debris disk accessible in situ. Heliophysics interest is in the verification of large-scale heliospheric magnetic field models by the measured effect on the motion of electrically charged interstellar dust. Reporting the makeup of interplanetary dust that ablates in our atmosphere is valuable to Earth sciences. FOSSIL’s DT is scalable and can be accommodated to a variety of mission opportunities, without restriction on launch dates, and for a large number of possible orbits.

Turner, Neal↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

Analytical solution for partial heating on the exterior of the pipe with application to measuring fluid flow rate

An analytical model using Green’s functions for partial external heating of a pipe is developed, which results in an exact mathematical solution for the radial and axial temperature distribution in the pipe wall. Partial heating consists of a constant heat flux function imposed over a small section of the exterior of a pipe and for a limited time duration. The solution comprises steady-state and transient parts, and an algebraic identity is used to decrease the number of summation terms in the slowly-converging steady- state part. Intrinsic verification principles are used to verify the solution. As an example application, this transient solution is applied toward the development of a simple, noninvasive method for in-field measurement of the flow rate in pipes. Furthermore, to simulate this application, a pulse of energy is imposed to the wall of the pipe, and the developed mathematical solution is used to find the flow rate of the fluid inside the pipe. An optimal experiment is designed to find the best measurement location and time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Studies regarding the quality of numerical weather forecasts of the WRF model integrated at high-resolutions for the Romanian territory

Our paper aims to evaluate the quality of high-resolution weather forecasts from the Weather Research and Forecasting (WRF) numerical weather prediction model. The lateral and boundary conditions were obtained from the numerical output of the Consortium for Small-scale Modeling (COSMO) model at 7 km horizontal resolution. Furthermore, the WRF model was run for January and July 2013 at two horizontal resolutions (3 and 1 km). The numerical forecasts of the WRF model were evaluated using different statistical scores for 2 m temperature and 10 m wind speed. Our results showed a tendency of the WRF model to overestimate the values of the analyzed parameters in comparison to observations.

54 ENVIRONMENTAL SCIENCES↗

Uranium Mononitride (UN) Handbook

Uranium Mononitride (UN) is being reexamined as a high temperature advanced nuclear fuel in many reactor applications due to its high thermal conductivity, high melting point, and high fissionable uranium density, among other desirable properties. A thorough review of the experimental data for the material and irradiation properties has been collected and is presented in this handbook. As an outcome of this review, in many cases, it is apparent that additional experimental verification must be conducted to verify the available data and to verify the suggested empirical correlations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal contact algorithms in SIERRA mechanics : mathematical background, numerical verification, and evaluation of performance.

We examine algorithms for the finite element approximation of thermal contact models. We focus on the implementation of thermal contact algorithms in SIERRA Mechanics. Following the mathematical formulation of models for tied contact and resistance contact, we present three numerical algorithms: (1) the multi-point constraint (MPC) algorithm, (2) a resistance algorithm, and (3) a new generalized algorithm. We compare and contrast both the correctness and performance of the algorithms in three test problems. We tabulate the convergence rates of global norms of the temperature solution on sequentially refined meshes. We present the results of a parameter study of the effect of contact search tolerances. We outline best practices in using the software for predictive simulations, and suggest future improvements to the implementation.

97 MATHEMATICS AND COMPUTING↗

Evaluating decadal predictions of northern hemispheric cyclone frequencies

Mid-latitudinal cyclones are a key factor for understanding regional anomalies in primary meteorological parameters such as temperature or precipitation. Extreme cyclones can produce notable impacts on human society and economy, for example, by causing enormous economic losses through wind damage. Based on 41 annually initialised (1961–2001) hindcast ensembles, this study evaluates the ability of a single-model decadal forecast system (MPI-ESM-LR) to provide skilful probabilistic three-category forecasts (enhanced, normal or decreased) of winter (ONDJFM) extra-tropical cyclone frequency over the Northern Hemisphere with lead times from 1 yr up to a decade. It is shown that these predictions exhibit some significant skill, mainly for lead times of 2–5 yr, especially over the North Atlantic and Pacific. Skill for intense cyclones is generally higher than for all detected systems. A comparison of decadal hindcasts from two different initialisation techniques indicates that initialising from reanalysis fields yields slightly better results for the first forecast winter (month 10–15), while initialisation based on an assimilation experiment provides better skill for lead times between 2 and 5 yr. The reasons and mechanisms behind this predictive skill are subject to future work. Preliminary analyses suggest a strong relationship of the model's skill over the North Atlantic with the ability to predict upper ocean temperatures modulating lower troposphere baroclinicity for the respective area and time scales.

MiKlip↗

The Suzaku High Resolution X-ray Spectrometer

The high resolution X-Ray Spectrometer (XRS) has been designed to provide the Suzaku Observatory with very high spectral resolution, non-dispersive spectroscopy from 0.3 to 12 keV. This energy range encompasses the most diagnostically-rich part of the x-ray band. The sensor consists of a 32 channel array of x-ray of microcalorimeters, each with an energy resolution of about 6 eV. The very low temperature required for operation of the array (60 mK) is provided by a four-stage cooling system containing a single stage ADR, superfluid He Cryostat, solid Ne Dewar, and a single-stage Stirling-cycle cooler. The Suzaku/XRS is the first orbiting x-ray microcalorimeter spectrometer and has been designed to last more than three years in orbit. The early verification phase of the mission demonstrated that the instrument was working properly and that the cryogen consumption rate was low enough to ensure a mission lifetime exceeding 3 years. However, the liquid He cryogen was completely vaporized two weeks after opening the dewar guard vacuum vent. The problem has been traced to inadequate venting of the dewar He and Ne gases out of the spacecraft into space. In this paper we present the design of the XRS instrument and describe the in-flight performance.

Kelley, Richard L.↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

On the Use of Ionic Liquids for the Recycling of the Contaminated Material

Dealing with spent nuclear fuel (SNF) and other radioactive waste management is one of the main issues of the nuclear industry. Today, there is an increased demand for lower environmental affection and higher safety assurances within all industries dealing with radioactivity. The resulting increasing costs for dealing with radioactive waste, altogether with the pressure of public opinion, are strong motivation factors for the development of recycling schemes, softening the effects on the environment, and bringing economic advantages for the nuclear industry. This problem is even multiplied as a significant wave of decommissioning of nuclear facilities can be expected in the next decades and it makes the problem even more urgent. The Organisation for Economic Co-operation and Development/Nuclear Energy Agency estimates that 400 nuclear power plants will have to be decommissioned between 2014 and 2050 and it will generate more than 5 million tons of radioactive scrap metal. If the decommissioning of other nuclear installations is taken into account, almost 30 million tons of scrap metal contaminated by radionuclides will need to be handled?1 According to an International Atomic Energy Agency report?2 during the nuclear facility decommissioning process, only 3 % of the material is considered contaminated, but costs for its disposal can make over 60 % of overall costs. In both of mentioned areas - SNF reprocessing and material decontamination - possible benefits of ionic liquids (ILs) are studied worldwide because of their interesting physical-chemical properties and chemical behavior. ILs (described as room-temperature molten salts in older literature) are commonly described as salts with organic cations associated with organic or inorganic anions that are liquid below 373 K and fully consisting of ions and offer advantages of nonaqueous processes like a safer environment because of substituting volatile and flammable organic solvents or less serious criticality issues. At the same time, ILs beat high-temperature molten salt in comparing energy costs. Also some other of ILs' unique properties are definitely attractive for areas of SNF reprocessing and solid waste decontamination. Among other major advantages of ionic liquids, negligible vapor pressure, non-flammability, chemical and mechanical stability, tunability as well as good electric conductivity or wide electrochemical window are usually being mentioned. In this contribution, the experimental verification of some principles needed for the development of the decontamination of material contaminated with uranium and europium are presented as model cases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification of GENE and GYRO with L-mode and I-mode plasmas in Alcator C-Mod

Here, verification comparisons are carried out for L-mode and I-mode plasma conditions in Alcator C-Mod. We compare linear and nonlinear ion-scale calculations by the gyrokinetic codes GENE and GYRO to each other and to the experimental power balance analysis. The two gyrokinetic codes' linear growth rates and real frequencies are in good agreement throughout all the ion temperature gradient mode branches and most of the trapped electron mode branches of the kyρs spectra at r/a = 0.65, 0.7, and 0.8. The shapes of the toroidal mode spectra of heat fluxes in nonlinear simulations are very similar for k y ρ s ≤ 0.5, but in most cases GENE has a relatively higher heat flux than GYRO at higher mode numbers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of A Long Duration Crop in the Advanced Plant Habitat Engineering Demonstration Unit: Key Factors to Consider Prior to Testing and Lessons Learned

The Advanced Plant Habitat (APH) is a fully enclosed, closed-loop, plant growth facility currently deployed on the International Space Station (ISS). It is equipped with complete environmental control (i.e.spectral qualityandlight intensity, temperature, relative humidity, and CO2),root module which containsa growth substrate(typically arcillite) and a porous tube based automated water delivery system. Two APH units, one ground unitidentical to the on-orbit versionand an Engineering Development Unit (EDU; a high fidelity test version), currently reside at Kennedy Space Center. Prior to conducting tests on-orbit, these APH ground units areutilized to conductbothScience Verification Tests(SVT; primarilyinthe EDU) and Experiment Verification Tests (EVT; primarily in the Ground Unit). In February 2020, a 122 day experiment was concluded in the APH EDU where four 'Numex Española Improved' pepper plants (Capsicum annuum) were successfully grown from seed to harvestyieldingover 50 fruit, demonstrating the capabilityand versatilityof this APH EDU system to support plant growth for long life cycle flowering/fruiting plants.

L. E. Spencer↗

Reliability and Safety Assessment of Urban Air Mobility Concept Vehicles

The following work was commissioned by the National Aeronautics and Space Administration (NASA) to guide industry and future regulation related to urban air mobility (UAM). Prior studies compared the relative safety of NASA concept vehicles, Figure ES1, designed for UAM and provided recommendations for industry research, aircraft architectural improvements, and regulatory updates. After the prior study completed, the European Aviation Safety Agency (EASA) released regulatory guidance in the form of a special condition (SC), SC-VTOL-01, for multirotors with distributed propulsion and flight controls (DPFC). The objective of the current work was to develop DPFC architectures that will comply with SC-VTOL-01. Vehicle designs, DPFC architectures, and stability & control (S&C) models were developed to find limitations and trends to guide industry. To guide this task, NASA developed quad, hex, and an octorotor to better define vehicle attributes and trade space. Aircraft for study included electric, hybrid-electric, and turboshaft powerplants and collective and RPM control schemes. Assessments are in terms of the safety level achieved, and/or aircraft component/features needed to meet SC-VTOL-01. The most challenging criteria being the catastrophic failure rate, ≤10-9 catastrophic failures per flight hour, and that no single failures may result in a catastrophic event. A disciplined process was followed, similar to that in Aerospace Recommended Practice (ARP) 4761. A preliminary system safety assessment (PSSA) leveraged prior work as a basis of creating failure rate budgets for system design teams. System designs were updated and iterated upon, working with reliability and safety subject matter experts to develop SC-VTOL-01 compliant designs. Design changes were reflected in updated PSSAs for initial verification of compliance. The DPFC architecture was broken into four system design teams, the (1) flight control system (FCS), (2) drive and power system, (3) thermal management system (TMS), and (4) electrical power and distribution system. The FCS including elements necessary to control the aircraft, drive and power including elements necessary to generate and transmit shaft power, the TMS including elements necessary to maintain temperature limits in all operating environments, and electrical pow-er and distribution including equipment necessary to store and transmit electrical energy. Results found that all aircraft evaluated may have paths to comply with SC-VTOL-01, Figure ES2. However, S&C models showed large power transients that must be addressed and PSSA results show that future work is needed in single load path structures, high voltage power storage and distribution, and in motor/rotor overspeed protection.

Boeing↗