Graph-Theoretic Approaches to Quantifying Power System Resiliency

Although gaining growing importance, the subject of power system resiliency still lacks a commonly acknowledged metric. As a contribution to solving this complication, in this paper we leverage the concepts of spanning trees and Fiedler value from graph theory to propose two topology-based indices for quantifying the resiliency of power systems. The proposed indices require least information and may be applied to any other flow network, such as water or gas pipeline networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Risk-Driven Probabilistic Approach to Quantify Resilience in Power Distribution Systems

It is of growing concern to ensure resilience in power distribution systems to extreme weather events. However, there are no clear methodologies or metrics available for resilience assessment that allows system planners to assess the impact of appropriate planning measures and new operational procedures for resilience enhancement. In this paper, we propose a resilience metric using parameters that define system attributes and performance. To represent extreme events (tail probability), the conditional value-at-risk of each of the parameters are combined using Choquet Integral to evaluate the overall resilience. The effectiveness of the proposed resilience metric is studied within the simulation-based framework under extreme weather scenarios with the help of a modified IEEE 123-bus system. With the proposed framework, system operators will have additional flexibility to prioritize one investment over the others to enhance the resilience of the grid.

Poudyal, Abodh↗

Bridging the Gap on Data and Analysis for Distribution System Planning: Information That Utilities Can Provide Regulators, State Energy Offices and Other Stakeholders

Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep anomaly detection for industrial systems: a case study

We explore the use of deep neural networks for anomaly detection of industrial systems where the data are multivariate time series measurements. We formulate the problem as a self-supervised learning where data under normal operation are used to train a deep neural network autoregressive model, i.e., use a window of time series data to predict future data values. The aim of such a model is to learn to represent the system dynamic behavior under normal conditions, while expect higher model vs. measurement discrepancies under faulty conditions. In real world applications, many control settings are discrete in nature. In this paper, vector embedding and joint losses are employed to deal with such situations. Both LSTM and CNN based deep neural network backbones are studied on the Secure Water Treatment (SWaT) testbed datasets. Also, Support Vector Data Description (SVDD) method is adapted to such anomaly detection settings with deep neural networks. Evaluation methods and results are discussed based on the SWaT dataset along with potential pitfalls.

anomaly detection, deep neural network↗

Hyperfine interactions for small systems including transition-metal elements using self-interaction corrected density-functional theory

The interactions between the electronic magnetic moment and the nuclear spin moment, i.e., magnetic hyperfine (HF) interactions, play an important role in understanding electronic properties of magnetic systems and in realizing platforms for quantum information science applications. We investigate the HF interactions for atomic systems and small molecules, including Ti or Mn, by using Fermi–Löwdin orbital (FLO) based self-interaction corrected (SIC) density-functional theory. We calculate the Fermi contact (FC) and spin-dipole terms for the systems within the local density approximation (LDA) in the FLO-SIC method and compare them with the corresponding values without SIC within the LDA and generalized-gradient approximation (GGA), as well as experimental data. For the moderately heavy atomic systems (atomic number Z ≤ 25), we find that the mean absolute error of the FLO-SIC FC term is about 27 MHz (percentage error is 6.4%), while that of the LDA and GGA results is almost double that. Therefore, in this case, the FLO-SIC results are in better agreement with the experimental data. For the non-transition-metal molecules, the FLO-SIC FC term has the mean absolute error of 68 MHz, which is comparable to both the LDA and GGA results without SIC. For the seven transition-metal-based molecules, the FLO-SIC mean absolute error is 59 MHz, whereas the corresponding LDA and GGA errors are 101 and 82 MHz, respectively. Therefore, for the transition-metal-based molecules, the FLO-SIC FC term agrees better with experiment than the LDA and GGA results. We observe that the FC term from the FLO-SIC calculation is not necessarily larger than that from the LDA or GGA for all the considered systems due to the core spin polarization, in contrast to the expectation that SIC would increase the spin density near atomic nuclei, leading to larger FC terms.

Chemistry↗

HFTS-1 Natural Joint Data and Engineering Summary

This report provides an analysis of engineering and geologic data collected from the Hydraulic Fracturing Test Site #1 (HTSF-1) project in the southern Midland Basin, Reagan County, Texas. The site is being studied as part of the Science-informed Machine Learning for Accelerating Real-Time Decisions in Subsurface Applications (SMART) Initiative at the National Energy Technology Laboratory (NETL). The data collected is intended to provide a basis of understanding of the site and to construct simulation models. This report provides a summary analysis of the engineering and geologic data collected from the project to provide a basis of understanding of the site and to construct simulation models. The report examines various possible correlations in engineering properties based on natural fracture data from the program, which consisted of 11 horizontal wells, one vertical well, and one slant well. The horizontal wells are in two horizons: 1) Upper and 2) Middle Wolfcamp formations. Program data include: fracture frequency and fracture orientation data from four core runs in a slant well; fracture spacing and orientation from a vertical pilot well; laboratory triaxial testing and mineralogical determinations; and porosity results from magnetic resonance analyses from various wells, together with observations based on the data collection. In addition, available references were reviewed on the site for additional insights. As the focus of the report is on the natural system, hydraulic fracture data from the site were not examined in detail in this report. Data variability is the chief observation in examination of the database. Fracture frequency in the slant well can range from sections with values as high as five fractures per ft to sections up to 100+ ft in length with no natural observed fractures. Fracture spacing across is typically less than 10 ft, but can range up to hundreds of feet. Apparent fracturing shows the trends in two predominate orientations, E-SW and WNW-ESE, but minor variations exist. The rock units vary across the site from siliceous mudstones to calcareous mudstones, showing a general layering with depth. The laboratory properties such as strength and modulus show no apparent trend with depth, but appear to correlate with rock mineralogy with high strength and modulus values where calcium content is high. In addition, an attempt to examine variability and mineralogy on a larger scale was made using a color-coded system based on gamma ray measurements. A staged colored approach was adopted, presuming that lower gamma ray values indicate higher value of calcium content (blue scale) and that higher gamma ray values indicate higher clay mineral content (orange scale). As provided in report appendices, the system correlated well with visual examination of the slant core and the petrofabric analyses of the vertical pilot well. The results showed large variability in mineral content along the horizontal plane across the site. The change in mineral content was also rapid, on a scale less than that of the average hydraulic fracture stage length of about 180 ft.

42 ENGINEERING↗

Mitigating Cascading Outages in Severe Weather Using Simulation-Based Optimization

Severe weather events can trigger cascading power outages and lead to significant losses. In this work, we investigate cascading outage mitigation under severe weather conditions. Given day-ahead weather forecasts and component failure models, we aim to identify a set of power lines that can be hardened to minimize the expected impact of potential cascading outages. Since the expected load shedding cannot be expressed as an explicit function of line hardening decisions and system states, we developed a cascading outage simulator to estimate the expected value of load shedding under various initial weather-related disruption scenarios generated using a weather forecast. To avoid massive enumeration of all possible combinations of line hardening decisions and reduce the simulation efforts, we employed an efficient simulation-based optimization approach that quickly identifies the (near) optimal line hardening decisions in the presence of both large simulation noises due to the highly variable initial disturbances and system states, and significant randomness in the subsequent cascades. Furthermore, the algorithm is also able to utilize parallel computing to dramatically reduce computation time to support decision making in preparation for severe weather conditions. We performed a case study on the Northeast Power Coordinating Council (NPCC) 140-bus system model to demonstrate that our approach can significantly improve power grid resilience to adverse weather events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications

Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.

25 ENERGY STORAGE↗

A Study of Imbalance Levels Attributed to Photovoltaic Penetration in Distribution Systems

Abstract— The number of renewable sources, namely photovoltaics (PV), continues to grow within distribution systems. How placements impact a system’s performance remains a concern within both the research and the utility communities. Beyond system node voltages and real power losses, this work looks to industry standard imbalance metrics and the changes experienced on these values with varied levels of PV. Specifically, four imbalance metrics are presented and studied for an actual 906-bus distribution system. Multiple loading conditions and photovoltaic placement schemes are explored to compare the changes seen on these metrics across a variety of scenarios experienced by the network.

14 SOLAR ENERGY↗

A Synthetic Transcription Factor and Core Promoter System in Picochlorum renovo Enables Tunable Gene Expression

Picochlorum renovo is a recently characterized microalga of industrial interest. Its rapid growth rate, and high temperature and salinity tolerances make P. renovo an attractive candidate for industrial scale cultivation and downstream production of sustainable fuels and chemicals. Currently, genetic tools for many non-model microalgae are limited and would greatly benefit from an orthogonal gene expression system to bypass host regulation. Additionally, the engineering of complex metabolic pathways in eukaryotic organisms to optimize growth or biosynthesize high value products often requires tunable expression of each gene in a pathway. Here we explore a tunable orthogonal gene expression system using a synthetic transcription factor (sTF) and core promoters (CPs) conferring expression of the fluorescent protein mCherry to quantify protein expression. The sTF paired with the relevant binding site (BS) led to an ~5X increase in reporter gene expression compared to the native RuBisCo promoter, however had limited tunability with increasing BS number. Quantification of mCherry expression under 34 different CPs paired with the sTF and BS showed an order of magnitude of expression tunability. Future work with this system will entail generation of an overexpression library via random integration of the relevant BS in an sTF expressing P. renovo strain. With this sTF and CP system we aim to greatly improve growth rates and product titers in photosynthetic organisms, while also providing a potentially universal gene expression system for microalgae.

algae↗

A new multi-model absolute difference-based sensitivity (MMADS) analysis method to screen non-influential processes under process model and parametric uncertainty

Process-based models have been widely used for hydrologic modeling, and it is a common practice to use sensitivity analysis methods for excluding non-influential hydrologic processes from further investigation and/or model improvement. This study develops a new method called multi-model absolute difference-based sensitivity (MMADS) analysis method to screen non-influential system processes and parameters. MMADS is conceptually similar to the Morris method for addressing parametric uncertainty, but has a unique feature to address both process model uncertainty (i.e., a process may be represented by multiple process models) and process model parameter uncertainty (i.e., parameters associated with a process model are random). MMADS first evaluates absolute differences of a quantity of interest (i.e., a system model output) by varying process models and/or process model parameter values, and then calculates the mean and variance of the differences for investigating process influence. The mean measures overall influence of the process on the quantity of interest, and the variance estimates influence of nonlinear effects of the process and/or its interactions with other processes. MMADS is an extension of the Morris method from a parameter space to a joint parameter-model space for explicitly addressing both process model uncertainty and model parameter uncertainty. The performance of MMADS is evaluated by using two numerical experiments. One experiment is based on Sobol’s G*-function with ten product elements, and has analytical solutions of the MMADS mean and variance of absolute differences. The other experiment is for groundwater flow modeling which considers three processes (i.e., recharge, geology, and snowmelt) that interact with each other. Finally, results indicate that MMADS is computationally efficient and can identify non-influential processes of complex hydrological systems.

54 ENVIRONMENTAL SCIENCES↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Combined Land Use of Solar Infrastructure and Agriculture for Socioeconomic and Environmental Co-Benefits in the Tropics

Solar photovoltaics (PV) are on the rise even in areas of low solar insolation. However, in developing countries with limited capital, land scarcity, or with geographically isolated agrarian communities, large solar infrastructures are often impractical. In these cases, implementation of low-density PV over existing crops may be required to integrate renewable energy services into rural communities. Here, using Indonesia as a model system, we investigated the land use, energy, greenhouse gas emissions, economic feasibility, and the environmental co-benefits associated with off-grid solar PV when combined with high value crop cultivation. The life cycle analyses indicate that small-scale dual land-use systems are economically viable in certain configurations and have the potential to provide several co-benefits including rural electrification, retrofitting diesel electricity generation, and electricity for processing agricultural products locally. A hypothetical full-density off-grid solar PV for a model village in Indonesia shows that electricity output (1907.5 GJ yr-1) is much higher than the total residential consumption (678 GJ yr-1), highlighting the opportunity to downscale the PV infrastructure by half to lower capital cost, to co-locate crops, and to support secondary income generating activities. Economic analysis shows that the 30-year net present cost of electricity from the half-density co-located PV system (12,257 million IDR) is significantly lower than that of the flat cost of diesel required to generate equivalent electricity (14,702 million IDR). Our analysis provides insights for smarter energy planning by optimizing the efficiency of land use and limiting conversion of agricultural and forested areas for energy production.

agrivoltaics↗

Performance and Techno-Economic Evaluation of a Three-Phase, 50-kW SiC-Based PV Inverter

The technical capabilities and benefits of silicon carbide (SiC) compared to silicon (Si) based power electronics converters as well as the premium associated with using SiC instead of Si are well understood. This work proves that the benefits provided by SiC, such as increased efficiency, would result in a lower levelized cost of energy (LCOE) compared to both commercially available, state-of-the-art inverters and the benchmark commercial system cost calculated for the U.S. Department of Energy Solar Energy Technologies Office's SunShot program. The LCOE is calculated to be same as the commercial benchmark despite the installed system cost being 8% more than the benchmark. The LCOE calculation is based on both experiential values obtained from testing the SiC photovoltaic (PV) inverter and on the bottoms-up modeled volume cost for the same 50-kW SiC-based inverter. The PV system used for the LCOE model is also explained, and the system cost breakout is presented in this paper. Furthermore, multiple scenarios with variations in the PV system are presented to show their effect on the system LCOE.

14 SOLAR ENERGY↗

Cost Projections for Utility-Scale Battery Storage (2020 Update)

In this work we describe the development of cost and performance projections for utility-scale lithium-ion battery systems, with a focus on 4-hour duration systems. The projections are developed from an analysis of 19 publications that consider utility-scale storage costs. The suite of publications demonstrates varied cost reductions for battery storage over time. Figure ES-1 shows the low, mid, and high cost projections developed in this work (on a normalized basis) relative to the published values. Figure ES-2 shows the overall capital cost for a 4-hour battery system based on those projections, with storage costs of $\$$144/kWh, $\$$208/kWh, and $\$$293/kWh in 2030 and $\$$88/kWh, $\$$156/kWh, and $\$$219/kWh in 2050. Battery variable operations and maintenance costs, lifetimes, and efficiencies are also discussed, with recommended values selected based on the publications surveyed.

14 SOLAR ENERGY↗

Cost Projections for Utility-Scale Battery Storage: 2021 Update

In this work we describe the development of cost and performance projections for utility-scale lithium-ion battery systems, with a focus on 4-hour duration systems. The projections are developed from an analysis of recent publications that consider utility-scale storage costs. The suite of publications demonstrates varied cost reductions for battery storage over time. Figure ES-1 shows the low, mid, and high cost projections developed in this work (on a normalized basis) relative to the published values. Figure ES-2 shows the overall capital cost for a 4-hour battery system based on those projections, with storage costs of $\$$143/kWh, $\$$198/kWh, and $\$$248/kWh in 2030 and $\$$87/kWh, $\$$149/kWh, and $\$$248/kWh in 2050. Battery variable operations and maintenance costs, lifetimes, and efficiencies are also discussed, with recommended values selected based on the publications surveyed.

25 ENERGY STORAGE↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗