Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Mapping the mechanical properties of rocks using automated microindentation tests

A microindentation scanner is constructed that measures the spatial fluctuation in the elastic properties of natural rocks. This novel instrument performs automated indentation tests on the surface of a rock slab and outputs 2-D maps of the indentation modulus at submillimeter resolution. Maps obtained for clean, well-consolidated, sandstone are presented and demonstrate the capabilities of the instrument. We postulate that the elastic structure of sandstones correlates well with their visual appearance. Moreover, we observe that the probability distribution of the indentation modulus fluctuations across the slab surfaces can be modeled using a lognormal probability density function. To illustrate possible use of the data obtained with the microindentation scanner, we use roughly 10 cm × 10 cm scans with millimeter resolution over four sandstone planar slabs to numerically compute the overall drained elastic moduli for each sandstone sample. We demonstrate that such numerically computed moduli are well modeled using the multicomponent form of the Hashin-Shtrikman lower bound that employs the observed lognormal probability distribution for the mesoscopic-scale moduli (the geometric mean works almost the same). We also compute the seismic attenuation versus frequency associated with wave-induced fluid flow between the heterogeneities in the scanned sandstones and report relatively small values for the inverse quality factor (Q -1 <10 -2 ) in the seismic frequency band 10 2 Hz 4 Hz. The numerically computed frequency dependence in the attenuation varies from one type of sandstone to another, and we determine vital anisotropy in the attenuation associated with waves propagating in different directions.

58 GEOSCIENCES↗

Direct Ink Writing of 3D Zn Structures as High‐Capacity Anodes for Rechargeable Alkaline Batteries

The relationship between structure and performance in alkaline Zn batteries is undeniable, where anode utilization, dendrite formation, shape change, and passivation issues are all addressable through anode morphology. While tailoring 3D hosts can improve the electrode performance, these practices are inherently limited by scaffolds that increase the mass or volume. Herein, a direct write strategy for producing template‐free metallic 3D Zn electrode architectures is discussed. Concentrated inks are customized to build designs with low electrical resistivity (5 × 10 −4 Ω cm), submillimeter sizes (200 μm filaments), and high mechanical stability (Young's modulus of 0.1–0.5 GPa at relative densities of 0.28–0.46). A printed Zn lattice anode versus NiOOH cathode with an alkaline polymer gel electrolyte is then demonstrated. This Zn||NiOOH cell operates for over 650 cycles at high rates of 25 mA cm −2 with an average areal capacity of 11.89 mAh cm −2 , a cumulative capacity of 7.8 Ah cm −2 , and a volumetric capacity of 23.78 mAh cm −3 . A thicker Zn anode achieves an ultrahigh areal capacity of 85.45 mAh cm −2 and a volumetric capacity of 81.45 mAh cm −3 without significant microstructural changes after 50 cycles.

25 ENERGY STORAGE↗

Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference

Purpose: First, to show that low-dose-rate prostate brachytherapy plans using oblique needle trajectories are more successful than parallel trajectories for large prostates with pubic arch interference (PAI); second, to test the accuracy of delivering an oblique plan by using a three-dimensional (3D) transrectal ultrasonography (TRUS)-guided mechatronic system. Methods and Materials: Prostates were contoured for 5 subjects' 3D TRUS images showing a maximum PAI of {<=}1 cm and a prostate volume of <50 cc. Two planning studies were done. First, prostate contours were artificially enlarged to 45 to 80 cc in 5- to 10-cc increments for a single subject. Second, all subject prostate contours were enlarged to 60 cc. For each study, three types of plans were manually created for comparison: a parallel needle template (PT) plan, a parallel needle no-template (PNT) plan, and an oblique needle no-template (OBL) plan. Needle positions and angles were not discretized for nontemplate plans. European Society for Therapeutic Radiology and Oncology dose-volume histogram guidelines, iodine-125 (145-Gy prescription, 0.43 U), and needle angles of <15 Degree-Sign were used. An OBL plan was delivered to a pubic arch containing a 60-cc prostate phantom that mimicked the anatomy of the subject with the greatest PAI (23% by volume). Results: In the increasing-prostate volume study, OBL plans were successful for prostates of {<=}80 cc, and PT plans were successful for prostates of <65 cc. In paired, one-sided t tests for the 60-cc volume study, OBL plans showed dosimetric improvements for all organs compared to both of the parallel type plans (p < 0.05); PNT plans showed a benefit only in planning target volumes receiving more than 100 Gy compared to PT plans. A computed tomography scan of the phantom showed submillimeter seed placement accuracy in all directions. Conclusion: OBL plans were significantly better than parallel plans, and an OBL plan was accurately delivered to a 60-cc prostate phantom with 23% PAI by volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior-posterior direction, with systematic ( N-Ary-Summation ) and random ({sigma}) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%{+-}19.8% of treatment time. Real-time tracking reduced prostate motion to N-Ary-Summation =0.01 mm and {sigma} = 0.55 mm in the anterior-posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%{+-}4.6% and 99.7%{+-}0.4% of the time, respectively. Without real-time tracking, pass rates based on a {gamma} index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Need for Comprehensive Validation of Deformable Image Registration, Investigated With a Novel 3-Dimensional Deformable Dosimeter

Purpose: To introduce and evaluate a novel deformable 3-dimensional (3D) dosimetry system (Presage-Def/Optical-CT) and its application toward investigating the accuracy of dose deformation in a commercial deformable image registration (DIR) package. Methods and Materials: Presage-Def is a new dosimetry material consisting of an elastic polyurethane matrix doped with radiochromic leuco dye. Radiologic and mechanical properties were characterized using standard techniques. Dose-tracking feasibility was evaluated by comparing dose distributions between dosimeters irradiated with and without 27% lateral compression. A checkerboard plan of 5-mm square fields enabled precise measurement of true deformation using 3D dosimetry. Predicted deformation was determined from a commercial DIR algorithm. Results: Presage-Def exhibited a linear dose response with sensitivity of 0.0032 ΔOD/(Gy∙cm). Mass density is 1.02 g/cm{sup 3}, and effective atomic number is within 1.5% of water over a broad (0.03-10 MeV) energy range, indicating good water-equivalence. Elastic characteristics were close to that of liver tissue, with Young's modulus of 13.5-887 kPa over a stress range of 0.233-303 kPa, and Poisson's ratio of 0.475 (SE, 0.036). The Presage-Def/Optical-CT system successfully imaged the nondeformed and deformed dose distributions, with isotropic resolution of 1 mm. Comparison with the predicted deformed 3D dose distribution identified inaccuracies in the commercial DIR algorithm. Although external contours were accurately deformed (submillimeter accuracy), volumetric dose deformation was poor. Checkerboard field positioning and dimension errors of up to 9 and 14 mm, respectively, were identified, and the 3D DIR-deformed dose γ passing rate was only γ{sub 3%/3} {sub mm} = 60.0%. Conclusions: The Presage-Def/Optical-CT system shows strong potential for comprehensive investigation of DIR algorithm accuracy. Substantial errors in a commercial DIR were found in the conditions evaluated. This work highlights the critical importance of careful validation of DIR algorithms before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable Image Registration for Adaptive Radiation Therapy of Head and Neck Cancer: Accuracy and Precision in the Presence of Tumor Changes

Purpose: To compare deformable image registration (DIR) accuracy and precision for normal and tumor tissues in head and neck cancer patients during the course of radiation therapy (RT). Methods and Materials: Thirteen patients with oropharyngeal tumors, who underwent submucosal implantation of small gold markers (average 6, range 4-10) around the tumor and were treated with RT were retrospectively selected. Two observers identified 15 anatomical features (landmarks) representative of normal tissues in the planning computed tomography (pCT) scan and in weekly cone beam CTs (CBCTs). Gold markers were digitally removed after semiautomatic identification in pCTs and CBCTs. Subsequently, landmarks and gold markers on pCT were propagated to CBCTs, using a b-spline-based DIR and, for comparison, rigid registration (RR). To account for observer variability, the pair-wise difference analysis of variance method was applied. DIR accuracy (systematic error) and precision (random error) for landmarks and gold markers were quantified. Time trend of the precisions for RR and DIR over the weekly CBCTs were evaluated. Results: DIR accuracies were submillimeter and similar for normal and tumor tissue. DIR precision (1 SD) on the other hand was significantly different (P<.01), with 2.2 mm vector length in normal tissue versus 3.3 mm in tumor tissue. No significant time trend in DIR precision was found for normal tissue, whereas in tumor, DIR precision was significantly (P<.009) degraded during the course of treatment by 0.21 mm/week. Conclusions: DIR for tumor registration proved to be less precise than that for normal tissues due to limited contrast and complex non-elastic tumor response. Caution should therefore be exercised when applying DIR for tumor changes in adaptive procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Establishment of Microbeam Radiation Therapy at a Small-Animal Irradiator

Microbeam radiation therapy is a preclinical concept in radiation oncology. It spares normal tissue more effectively than conventional radiation therapy at equal tumor control. The radiation field consists of peak regions with doses of several hundred gray, whereas doses between the peaks (valleys) are below the tissue tolerance level. Widths and distances of the beams are in the submillimeter range for microbeam radiation therapy. A similar alternative concept with beam widths and distances in the millimeter range is presented by minibeam radiation therapy. Although both methods were developed at large synchrotron facilities, compact alternative sources have been proposed recently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A numerical and experimental approach to compare the effect of sample thickness in small in-situ SEM and large ex-situ tensile testing in Alloy 709

ASTM standards for tensile tests define specific sample size requirements regardless of grain size of the material. However, sample size requirements for testing should be considered in conjunction with the number of grains within its reduced cross-sectional area. This is particularly important for in-situ Scanning Electron Microscope (SEM) tensile tests, as they have to be conducted on smaller samples. In this study, a comprehensive experimental and numerical evaluation of the effect of specimen thickness (and the resulting number of grains within the cross-section) were conducted using in-situ SEM tensile test (on submillimeter thick samples) and ex-situ tensile tests (on samples of 0.68–5.9 mm thickness) and the results are compared with FEM simulations outcome. All tests were conducted at room temperature and the results are correlated to the number of grains within the thickness of specimens. The tensile test results indicated that even though the 0.2% proof stress and the tensile strength do not vary for the current range of thicknesses (with number of grains in the cross-section varying from 13 to 118), a difference in necking mechanism exists. Post tensile strength, thinner samples undergo more shear failure and diagonal localized necking whereas thicker samples experience more diffuse necking indicated by decreased area of shear failure at the edges and increased area of dimpled tensile failure at the center of the sample. Further, FEM results complement the experimental findings by showing the formation of conjugated localized shear bands on the upper and lower surface in the 0.68 mm thick sample and shear bands combining to form singular shear bands in thicker samples. These results also confirm the validity of the in-situ SEM tensile tests conducted on thinner samples as long as the required minimum number of grains exist within the cross-section.

36 MATERIALS SCIENCE↗

Oncentra brachytherapy planning system

In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of several clinical sample cases were discussed to illustrate the effectiveness and clinical efficacy. The American Association of Physicists in Medicine brachytherapy reports of TG-43 and TG-186 were also described and compared in evaluations of fundamental calculation methodologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface-texture evolution of different chemical-vapor-deposited zinc sulfide flats polished with various magnetorheological fluids

The macro-structure of chemical-vapor-deposited (CVD) zinc sulfide (ZnS) substrates is characterizedby cone-like structures that start growing at the early stages of deposition. As deposition progresses,these cones grow larger and reach centimeter size in height and millimeter size in width. It is challengingto polish out these features from the top layer, particularly for the magnetorheological finishing (MRF)process. A conventional MR fluid tends to leave submillimeter surface artifacts on the finished surface,which is a direct result of the cone-like structure. Here we describe the MRF process of polishing four CVD ZnS substrates, manufactured by four differentvendors, with conventional MR fluid at pH 10 and zirconia-coated-CI (carbonyl iron) MR fluids at pH 4, 5,and 6. We report on the surface–texture evolution of the substrates as they were MRF polished with thedifferent fluids. We show that performances of the zirconia-coated-CI MR fluid at pH 4 are significantlyhigher than that of the same fluid at pH levels of 5 and 6 and moderately higher than that of a conventionalMR fluid at pH 10. An improvement in surface–texture variability from part to part was also observedwith the pH 4 MR fluid.

CVD ZnS↗

Micro-structural features and material properties impact on adhesive metal joints via computational modeling and machine learning

The quality of structural bonding in practical applications depends on various factors arising from materials, pre-processing conditions, and manufacturing. Understanding how these factors influence bonding performance and determining their relative importance are of significant interest. Thus, this study evaluates the effects of microstructural features and material properties on the structural strength of adhesively-bonded metal joints at the submillimeter scale, utilizing a combination of Finite Element Modeling (FEM) and Machine Learning (ML) with Gradient Boosting Regression (GBR). The microstructural features include adhesive thickness, internal voids within the adhesive, adherend-adhesive interfacial voids, void size and volume fraction, and surface roughness. The material properties include the constitutive behavior of the adhesive, as well as the adherend-adhesive interfacial strength and fracture energy. The changes in structural strength and morphologies of the bonded metal structures with respect to different microstructural features and material properties were clarified by FEM. By further leveraging ML-GBR, the sequence of importance of these factors affecting bonding performance across various scenarios was summarized. This work provides valuable insights into the development of improved structural bonding for adhesive joints in industries such as automotive , aerospace, and beyond.

36 MATERIALS SCIENCE↗

On the Origin of Room-Temperature Amplified Spontaneous Emission in CsPbBr 3 Single Crystals

CsPbBr 3 is an all-inorganic halide perovskite with excellent photoluminescence (PL) properties for laser applications. Amplified spontaneous emission (ASE) is a prerequisite for lasing and typically observed from low-dimensional CsPbBr3 nanostructures, where quantum confinement enhances ASE. However, a gain medium for lasing should be prepared into a robust bulk form that works under intense light illumination. Here, we demonstrate that bulk CsPbBr 3 single crystals exhibit highly efficient ASE with a threshold of 46 MWcm -2 at 520 nm, if PL reabsorption via the indirect Rashba gap is properly suppressed by thickness control. Based on a series of spectroscopic and microscopic measurements, we show that this below-the-gap absorption can significantly alter the PL feature and even the apparent color of the crystal depending on the crystal size. Our results show that a thin CsPbBr 3 single crystal can be utilized for lasing applications when engineered into a submillimeter thickness for effective light–matter interaction.

36 MATERIALS SCIENCE↗

Investigating Multiscale Spatial Distribution of Sulfur in a CNT Scaffold and Its Impact on Li–S Cell Performance

Ever increasing demand on high energy density batteries positions sulfur as a very promising cathode material for next-generation energy storage due to its high theoretical capacity of 1675 mAh/g. Electronically sulfur is highly insulating, and therefore integration of a conducting framework such as a carbon nanotube (CNT) scaffold with sulfur is a key aspect of the cathode design. Despite numerous efforts dedicated to S-CNT cathode development, increasing sulfur loading to above 1 mg/cm 2 while maintaining the cycling stability of the Li–S cell remains challenging. This could be partly due to the lack of understanding of the spatial distribution of sulfur in the CNT matrix and its location with respect to the morphology of the CNT scaffold. We demonstrate herein that the sulfur has a hierarchical distribution in the CNT cathode at high sulfur loading (>5 mg/cm 2 ) spanning multiple length scales (from nanometer to submillimeter). Sulfur infiltration into the CNT rather than the sulfur loading plays a key role in determining the redox reaction kinetics, Li + ion diffusion, and the galvanostatic cycling capacity and stability of Li–S cells. This study provides new insights for the design and fabrication of high loading, binder-free sulfur–carbon-based cathode architectures for next-generation high energy Li–S batteries.

25 ENERGY STORAGE↗

Hybrid MBE Route to Adsorption-Controlled Growth of BaTiO 3 Membranes with Robust Polarization Switching

Freestanding ferroelectric membranes are promising for flexible electronics, nonvolatile memory, photonics, and spintronics, but their synthesis is challenged by the need for reproducibility with precise stoichiometric control. Here, we demonstrate the adsorption-controlled growth of single-crystalline, epitaxial BaTiO 3 films by hybrid molecular beam epitaxy (MBE) on a binary oxide sacrificial layer. Using a simple water-droplet lift-off method, we obtained submillimeter- to millimeter-sized membranes that retained crystallinity, as confirmed by high-resolution X-ray diffraction, and exhibited robust tetragonal symmetry, as verified by Raman spectroscopy. Impedance spectroscopy confirmed a high dielectric constant of ∼1340, reflecting the robust dielectric response of the membranes. Ferroelectric functionality was revealed by piezoresponse force microscopy (PFM) and further verified by polarization-electric field (P-E) loop measurements with Positive-Up-Negative-Down (PUND). The P-E loops exhibited a remnant polarization of ∼5 μC cm –2 and a coercive field of ∼63 kV cm –1 . Furthermore, these results were interpreted in relation to c- and a-domain configurations.

Raman spectroscopy↗

Patterning and Reversible Actuation of Liquid Gallium Alloys by Preventing Adhesion on Rough Surfaces

This work reports here a simple approach to form, study, and utilize rough coatings that prevent the adhesion of gallium-based liquid metal alloys. Typically, liquids with large interfacial tension do not wet nonreactive surfaces, regardless of surface topography. However, these alloys form a surface oxide “skin” that adheres to many substrates, even those with low surface energy. This work reports a simple approach to render closed channels and surfaces, including soft materials, to be “oxide-phobic” via spray-coating (NeverWet, which is commercially available and inexpensive). Surface spectroscopic techniques and metrology tools elucidate the coatings to comprise silica nanoparticles grafted with silicones that exhibit dual length scales of roughness. Although prior work shows the importance of surface roughness in preventing adhesion, the present work confirms that both hydrophobic and hydrophilic rough surfaces prevent oxide adhesion. Furthermore, the coating enables reversible actuation through submillimeter closed channels to form a reconfigurable antenna in the gigahertz range without the need for corrosive acids or bases that remove the oxide. In addition, the coating enables open surface patterning of conductive traces of liquid metal. This shows it is possible to actuate liquid metals in air without leaving neither metal nor oxide residue on surfaces to enable reconfigurable electronics, microfluidics, and soft electrodes.

36 MATERIALS SCIENCE↗

Loss and Isotopic Fractionation of Alkali Elements during Diffusion-Limited Evaporation from Molten Silicate: Theory and Experiments

Moderately volatile elements (MVEs) are variably depleted in planetary bodies, reflecting the imprints of nebular and planetary processes. Among MVEs, Na, K, and Rb are excellent tracers for unraveling the history of MVE depletion in planetary bodies because they have similar geochemical behaviors but can be chemically fractionated by evaporation and condensation processes. Furthermore, K and Rb are amenable to high-precision isotopic analyses, which can help constrain the conditions of evaporation and condensation. To quantitatively understand why Na, K, and Rb are depleted in planetary bodies, we have carried out vacuum evaporation experiments from basaltic melt at 1200 and 1400 °C to study their evaporation kinetics and isotopic fractionations. We chose this composition because it is relevant to evaporation from small differentiated planetesimals. The Rb isotopic compositions of the evaporation residues were measured by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), and the K isotopic compositions were measured along profiles across the residues by secondary ion mass spectrometry (SIMS). In the 1400 °C run products, we found that the concentrations of both K and Rb in the run products decreased from core to rim, which was accompanied by a heavy K isotope enrichment near the surface. This indicates that, in this run, evaporation was limited by diffusion. To use those data quantitatively, we derive analytical equations that describe the evaporation rate and isotopic fractionation associated with diffusion-limited evaporation from a sphere, slab, and cylinder in transient and quasi-steady state regimes. This model is used to tease out the roles that diffusive transport in the melt and evaporation at the melt/gas interface play in setting the elemental depletion and isotopic composition of the residue. Under our experimental conditions, volatility decreases in the order of Na, Rb, and K. Using our experimental results in a thermodynamic model, we have estimated the product γΓ of activity coefficients × evaporation coefficients of Na, Rb, and K. The measured isotopic compositions of the residues are well explained using Rayleigh distillations, whereby the relative volatilities of K and Rb isotopes are given by the square root of their masses. We use our results and previously published data to predict how K and Rb could have been lost as a function of temperature, melt composition, oxygen fugacity, and saturation degree relevant to Vesta’s building blocks. We find that the K and Rb depletions, K/Rb elemental fractionation, and δ 41 K and δ 87 Rb isotopic fractionations of Vesta (as sampled by howardite-eucrite-diogenite (HED) meteorites) are best explained by evaporation of submillimeter size objects for 0.1-10 years at moderate temperatures (~1050 °C) in a medium ~98.8% saturated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗