DESI (Dark Energy Spectropic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. The DESI instrument is a robotically-actuated, fiber-fed spectrograph capable of taking up to 5,000 simultaneous spectra over a wavelength range from 360 nm to 980 nm. The fibers feed ten three-arm spectrographs with resolution $R= \lambda/\Delta\lambda$ between 2000 and 5500, depending on wavelength. The DESI instrument will be used to conduct a five-year survey designed to cover 14,000 deg$^2$. This powerful instrument will be installed at prime focus on the 4-m Mayall telescope in Kitt Peak, Arizona, along with a new optical corrector, which will provide a three-degree diameter field of view. The DESI collaboration will also deliver a spectroscopic pipeline and data management system to reduce and archive all data for eventual public use.
The response of a panel or window to the sonic boom and to other transient loads can often be found by deriving an equivalent lumped parameter model for the structure. The maximax response of such a mechano-acoustical system depends strongly upon the damping mechanisms of the components. This paper is concerned with finding realistic values for the lower bounds of the damping mechanisms in various mechano-acoustical systems. The results indicate that although part of the damping consists of radiation losses at openings, and radiation and viscous losses at narrow interconnecting hallways, the structural damping of the panel is of primary concern.
Tests were conducted in the launch phase simulator test facility, with the Orbiting Geophysical Observatory structural model and the Nimbus-type shroud being used as test items. Data are given for the acoustic vibratory response of the spacecraft as the ambient pressure external to the shroud was reduced. The results show that at most spacecraft locations, the reduction in ambient pressure causes a significant reduction in the vibration response. There are, however, certain locations on the spacecraft and spacecraft adapter trusses where the reduction in ambient pressure has no effect. The differences in vibration responses obtained in this test can be directly related to two important factors: (1) excitation path - the path through which the external acoustic energy flows (either the mechanical path through structural members, or the air path directly from shroud to spacecraft); and (2) noise reduction of the shroud as a function of ambient pressure. As the pressure external to the shroud is reduced, the vented shroud has a corresponding decrease in internal pressure. The change in internal air density means less energy will be transmitted via the air path.
The microstructure of solar wind stream interaction regions is considered theoretically with emphasis on the role of several electrostatic kinetic instabilities which may be important within the stream interface and the compression region. Inside of 1 AU, the interface is likely to be stable against the electrostatic streaming instabilities considered. Between 1 and 2 AU, the interface will excite the magnetized ion-ion instability. The compression region is also found to be unstable beyond 1 AU where the modified two-stream instability, beam-cyclotron instability, and ion-acoustic instability are important in determining the structure of the compressive pulses as they evolve into forward and reverse shocks. It is concluded that the modified two-stream instability and beam-cyclotron instability predominately play a role in heating the electrons to the threshold for the ion-acoustic instability. Various electrostatic plasma waves, ranging in frequency from the lower-hybrid to harmonics of the electron cyclotron frequency, would be produced by these instabilities. Their signature should also be seen by high time resolution measurements of the temperature of the various plasma species.
Monitoring of structures under operating loads to provide an early warning of possible failure to locate flaws in test specimens subjected to uniaxial tensile loading is presented. Test specimens used are mild steel prismatic bars with small holes at different locations. When the test specimen is loaded, acoustic emission data are automatically collected by two acoustic transducers located at opposite sides of the hole and processed by an acoustic emission analyzer. The processed information yields the difference in arrival times at the transducers, which uniquely determines the flaw location. By using this technique, flaws were located to within 8 percent of their true location. The use of acoustic emission in linear location to locate a flaw in a material is demonstrated. It is concluded that this one-dimensional application could be extended to the general flaw location problem through triangulation.
The layered crystal structures of cuprates enable collective charge excitations fundamentally different from those of three-dimensional metals. Acoustic plasmons have been observed in electron-doped cuprates by resonant inelastic X-ray scattering (RIXS); in contrast, whether acoustic plasmons exist in hole-doped cuprates is under debate, despite extensive measurements. This contrast led us to investigate the charge excitations of hole-doped cuprate La 2-x Sr x CuO 4 . Here we present incidentenergy-dependent RIXS measurements and calculations of collective charge response via the loss function to reconcile the aforementioned issues. Our results provide evidence for the acoustic plasmons of Zhang-Rice singlet (ZRS), which has a character of the Cu 3d x 2 -y 2 strongly hybridised with the O 2p orbitals; the metallic behaviour is implied to result from the movement of ZRS rather than the simple hopping of O 2p holes.
Finite element models were developed of a floor-equipped, frame and stringer stiffened composite cylinder including a coarse finite element model of the structural components, a coarse finite element model of the acoustic cavities above and below the beam-supported plywood floor, and two dense models consisting of only the structural components. The report summarizes the geometry, the element properties, the material and mechanical properties, the beam cross-section characteristics, the beam element representations and the boundary conditions of the composite cylinder models. The expressions used to calculate the group speeds for the cylinder components are presented.
This study consists of an investigation into the nonstationary transient response of the Verification Test Article (VETA) when subjected to random acoustic excitation. The goal is to assess excitation models that can be used in the design of structures and equipment when knowledge of the structure and the excitation is limited. The VETA is an instrumented cantilever beam that was exposed to acoustic loading during five Space Shuttle launches. The VETA analytical structural model response is estimated using the direct averaged power spectral density and the normalized pressure spectra methods. The estimated responses are compared to the measured response of the VETA. These comparisons are discussed with a focus on prediction conservatism and current design practice.
A major source of fan noise in commercial turbofan engines is the interaction of the wake from the fan blades with the stationary vanes (stators) directly behind them. The Trailing Edge Blowing (TEB) project team at the NASA Glenn Research Center designed and fabricated new fan blades to study the effects of fan trailing edge blowing as a potential noise-reduction concept. The intent is to fill the rotor wake by supplying air to the rotor blade trailing edge at the proper conditions to minimize the wake deficit, and thus generate less noise. The TEB hardware is designed for the Active Noise Control Fan (ANCF) test rig in Glenn's Aeroacoustic Propulsion Laboratory. For this test, the air is fed from an external supply through the shaft of the rig. It is distributed to the base of each blade through an impeller, where it is forced into a plenum at the core of each blade. In actual engine configuration, air would most likely be bled from the compressor, but only at times when noise is an issue, such as takeoffs and landings. Glenn researchers designed and manufactured the blades in-house, using new techniques and concepts. The skins, which were designed for maximum strength in the directions of highest stress, were molded from multiple layers of carbon fiber. Considerable use was made of rapid prototyping techniques, such as laser sintering. The core was sintered from a lightweight polymer, and the retainer was CNC-machined (computer numerical control machined) from aluminum. All the components were joined with a cold-cure aerospace adhesive. These techniques and processes reduced the overall cost and allowed the new concept to be studied much sooner than would be possible using traditional fabrication methods. Since this test rig did not support the use of blade-monitoring techniques such as strain gauges, extensive bench testing was required to qualify the design. The blades were examined using a variety of methods including holography, pull tests (cyclic and failure), shake tests, rap tests, and nondestructive inspection. Acoustic testing of the ANCF fan using TEB has been ongoing since January of 2001. The fan has completed about 100 hr of testing with no structural, vibrational, or fatigue problems. Far-field acoustic measurements, in-duct mode measurements, precise hot wire surveys, and detailed performance measurements are providing data for evaluating the concept. The far-field noise data show that tone noise was reduced significantly with the initial ANCF TEB fan design. In addition, a significant reduction in unsteady stator loading has been measured, indicating the potential for stator broadband noise reduction. The acoustic benefits will be assessed and important design parameters identified to improve the ability to fully exploit any benefit provided by this technique. On the basis of the success of trailing edge blowing, Glenn plans to continue this research with a higher speed, higher pressure ratio fan operating in an acoustic wind tunnel to simulate flight conditions.
Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied to two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.
Measurements of the response of a large frame-stringer panel excited by supersonic turbulent boundary layer are reported. The statistical description of the wall pressure fluctuations in terms of the mean flow parameters governing the turbulent boundary layer is given. These results can be used in the development of design criteria on the response of sidewall structure of a large airplane in supersonic flight, since both forcing field and structure are realistic. Results indicate the significant importance of the modal coupling and the acoustic damping. The acoustic damping plays a major role in the response of the structure.
The goal of this study is to better understand the effect of structurally integrated resonators on the transmission loss of a sandwich panel. The sandwich panel has facesheets over a corrugated core, which creates long aligned chambers that run parallel to the facesheets. When ports are introduced through the facesheet, the long chambers within the core can be used as low-frequency acoustic resonators. By integrating the resonators within the structure they contribute to the static load bearing capability of the panel while also attenuating noise. An analytical model of a panel with embedded resonators is derived and compared with numerical simulations. Predictions show that acoustic resonators can significantly improve the transmission loss of the sandwich panel around the natural frequency of the resonators. In one configuration with 0.813 m long internal chambers, the diffuse field transmission loss is improved by more than 22 dB around 104 Hz. The benefit is achieved with no added mass or volume relative to the baseline structure. The embedded resonators are effective because they radiate sound out-of-phase with the structure. This results in destructive interference, which leads to less transmitted sound power.
The optical properties of liquid crystals serve as the basis for display, diagnostic, and sensing technologies. Such properties are generally controlled by relying on electric fields. In this work, we investigate the effects of microfluidic flows and acoustic fields on the molecular orientation and the corresponding optical response of nematic liquid crystals. Several previously unknown structures are identified, which are rationalized in terms of a state diagram as a function of the strengths of the flow and the acoustic field. The new structures are interpreted by relying on calculations with a free energy functional expressed in terms of the tensorial order parameter, using continuum theory simulations in the Landau-de Gennes framework. Taken together, the findings presented here offer promise for the development of new systems based on combinations of sound, flow, and confinement.
A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.
A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.
The dynamic characterization of lightweight structures is particularly complex as the impact of the weight of sensors and instrumentation (cables, mounting of exciters...) can distort the results. Varying mass loading or constraint effects between partial measurements may determine several errors on the final conclusions. Frequency shifts can lead to erroneous interpretations of the dynamics parameters. Typically these errors remain limited to a few percent. Inconsistent data sets however can result in major processing errors, with all related consequences towards applications based on the consistency assumption, such as global modal parameter identification, model-based damage detection and FRF-based matrix inversion in substructuring, load identification and transfer path analysis [1]. This paper addresses the subject of accuracy in the context of the measurement of the dynamic properties of a particular lightweight structure. It presents a comprehensive comparative study between the use of accelerometer, laser vibrometer (scanning LDV) and PU-probe (acoustic particle velocity and pressure) measurements to measure the structural responses, with as final aim the comparison of modal model quality assessment. The object of the investigation is a composite material blade from the main rotor of a helicopter. The presented results are part of an extensive test campaign performed with application of SIMO, MIMO, random and harmonic excitation, and the use of the mentioned contact and non-contact measurement techniques. The advantages and disadvantages of the applied instrumentation are discussed. Presented are real-life measurement problems related to the different set up conditions. Finally an analysis of estimated models is made in view of assessing the applicability of the various measurement approaches for successful fault detection based on modal parameters observation as well as in uncertain non-deterministic numerical model updating.
Wind energy production in the U.S. is projected to increase to 35% of our nation’s energy by 2050. This substantial increase in the U.S. is only a portion of the global wind industry growth, as many countries strive to reduce greenhouse gas emissions. A major environmental concern and potential market barrier for expansion of wind energy is bird and bat mortality from impacts with turbine blades, towers, and nacelles. Carcass surveys are the standard protocol for quantifying mortality at onshore sites. This method is imperfect, however, due to survey frequency at remote sites, removal of carcasses by scavengers between surveys, searcher efficiency, and other biases as well as delays of days to weeks or more in obtaining information on collision events. Furthermore, carcass surveys are not feasible at offshore wind energy sites. Near-real-time detection and quantification of interaction rates is possible at both onshore and offshore wind facilities using an onboard, integrated sensor package with data transmitted to central processing centers. We developed and experimentally tested an array of sensors that continuously monitors for interactions (including impacts) of birds and bats with wind turbines. The synchronized array includes three sensor nodes: (1) vibration (accelerometers and contact microphones), (2) optical (visual and infrared spectrum cameras), and (3) bioacoustics (acoustic and ultrasonic microphones). Accelerometers and contact acoustic microphones are placed at the root of each blade to detect impact vibrations and sound waves propagating through the structure. On-board data processing algorithms using wavelet analysis detect impact signals exceeding background vibration. Stereo-visual and infrared cameras were placed on the nacelle to allow target tracking, distance, and size calculations. On-board image processing and target detection algorithms identify moving targets within the camera field of view. Bioacoustic recorders monitor vocalizations and echolocations to aid in identifying organisms involved in interactions. Data from all sensors are temporarily stored in ring (i.e., circular) buffers with a duration varying by sensor type. Detection of target presence or impact by any of the sensors can trigger the archiving of data from all buffers for transmission to a central data processing center for evaluation and post-processing. This mitigates the risk of “data mortgages” posed by continual recording and minimizes personnel time required to manually review event data. We first conducted individual component tests at laboratories and field sites in Corvallis and Newport, Oregon, and Seattle and Sequim, Washington. We conducted additional component tests on research wind turbines at the North American Wind Research and Training Center, Mesalands Community College (MCC; General Electric 1.5 MW turbine), New Mexico, and the National Wind Technology Center, National Renewable Energy Laboratory (NREL; Controls Advanced Research Turbines 3 [CART 3] 600 kW Westinghouse turbine), Colorado. We conducted fully integrated system tests at NREL in October 2014 and April 2015. We used only research wind turbines so that we could conduct controlled, experimentally generated impacts using empty and water-filled tennis balls shot from a compressed air cannon on the ground. The approx. 57-140 g tennis balls (depending on water content) were at the upper mass range for bats, but lower mass range for marine birds. Therefore, the ability to detect collisions of most seabirds is likely greater than our experiments demonstrate, but possibly lower for some bats depending on the background signal of a given turbine. Vibration data demonstrated that background signals of operating turbines varied markedly among the CART 3 under normal operation (greatest), GE (moderate), and CART 3 during idle rotation (generator not engaged; least). In total, we measured 63 experimental blade impacts on the two research turbines. Impaction detection was dependent on background signals, position of impact on the blade (a tip strike resulted in the strongest impact signal), and impact kinetics (velocity of ball and whether the ball struck the surface of the blade or the leading edge of the blade struck the ball). Overall detection percentage ranged from 100% for the “quietest” conditions (CART 3 idle rotation), down to 35% for the noisiest (CART 3 normal operation). Impact signals were detected from sensors on more than one blade (i.e., blades other than the blade struck) 50% - 75% of the time. Stereo imaging provided valuable metrics, but increased data processing and equipment cost. Given the cost of cameras with sufficient resolution for target identification, we suggest mounting cameras directly on the blades to continuously view the entire rotor swept area with the fewest number of cameras. Bioacoustic microphones provide taxonomic identification, as well as information on ambient noise levels. They also assist in identifying environmental conditions such as hail storms, high winds, thunder, lightning, etc., that may contribute to a collision or a false positive detection. We demonstrated a proof of concept for an integrated sensor array to detect and identify bird and bat collisions with wind turbines. The next phase of research and development for this system will miniaturize and integrate sensors from all three nodes into a single wireless package that can be attached directly to the blade. This next generation system would use all “smart” sensors capable of onboard data processing to drastically reduce data streams and processing time on a central computer. A provisional patent for the blade mounted system was submitted by Oregon State University and recorded by the U.S. Patent and Trademark Office (application no. 62313028). Eventually, technology and industry advances will allow this low cost monitoring system to be designed into materials during manufacturing so that all turbines could be monitored with either a subset or full suite of sensors. As standard equipment on all commercial turbines, the sensor suite would allow the industry to effectively monitor whether individual turbines were causing mortalities or not and under what circumstances. It would also provide real-time evaluation of mechanical and structural integrity of a turbine via vibration, image, and acoustic data streams, thereby permitting modifications in operation to limit environmental or mechanical damage.