Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Raspberry colloid-templated approach for the synthesis of palladium-based oxidation catalysts with enhanced hydrothermal stability and low-temperature activity

It is becoming increasingly urgent to develop and utilize novel, more efficient and stable materials for mobile and stationary emission control applications as the deleterious consequences of anthropogenic air pollution are becoming more evident and pressing. Tightening regulations, particularly related to automotive exhaust treatment, together with continued improvements in engine design, that result in lowering the engine operating temperatures and inadvertently lead to the release of an overwhelming proportion of pollutants during the cold start, present new challenges for materials design, specifically for oxidation catalysts. In particular, improvements in the low-temperature activity while maintaining catalyst stability at high temperatures are required from the next-generation catalyst. Typical catalysts for removal of pollutants from automotive exhaust streams incorporate platinum group metals (PGMs). They tend to be inefficient at low temperatures (below 250 °C), thus accounting for the cold start problem, yet sinter and lose their activity at high temperatures that are frequently encountered during catalyst operation. High PGM loadings are often employed to compensate for catalyst inefficiencies and fast degradation, ultimately resulting in high-cost catalytic converters. Here, we have developed a new approach for the design and formation of catalytic materials that allows for both significantly more efficient PGM incorporation and improved overall catalyst performance at reduced PGM loadings. The method provides control over the composition and geometry of the support through self-assembly of sacrificial composite template — “raspberry” polymeric colloids decorated with catalytic particles — accompanied by infiltration with metal-oxide precursor and subsequent removal of the colloids. This method simultaneously structures the porous network and organizes the catalytic particles within it. Uniquely, the resulting catalytic particles are partially embedded in the support matrix and partially exposed to the pore interior, producing catalytic sites that are both stable and accessible. Herein, the feasibility of this novel and versatile approach for automotive catalytic conversion is demonstrated: the studies include testing alumina-based raspberry-colloid-templated (RCT) catalysts containing Pd nanoparticles (RCT Pd/Al2O3) for oxidation of propane and carbon monoxide under simulated diesel exhaust conditions and hydrothermal aging at 800 °C for 50 h in the simulated stream. The RCT Pd/Al2O3 catalysts exhibit exceptional activity toward CO oxidation, reduced reaction onset temperature, and high stability to elevated temperatures (demonstrated through prolonged exposure to temperatures up to 950 °C) and reactive gas streams, without migration, sintering or loss of the precious metal NPs. Notably, the novel catalyst shows the same or slightly better performance than the commercial catalysts even when the PGM load is reduced by ~80 % compared to the commercial counterparts. These results provide confidence for the utilization of the RCT approach for the fabrication of robust nanostructured catalysts for next-generation, energy-efficient catalytic converters with improved performance at low and high temperatures and reduced costs. The RCT methodology is, in addition, highly generalizable, and can thus be applied for the design of a wide range of catalytic systems in the automotive sector and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Form of Chromium on Spinel Formation

A number of Hanford high level waste (HLW) streams contain sufficiently high concentrations of chromium for it to become the waste loading limiting component in the waste. Chromium has relatively low solubility in borosilicate glasses and leads to the formation of various crystal phases including spinels. The extent of crystal formation must be managed during melter processing to prevent operational issues and potential premature melter failure that can result from excessive accumulation of crystals in the melter. In previous work for the Department of Energy (DOE) Office of River Protection (ORP), high-waste loading glass formulations were developed for representative HLW streams that are high in chromium. Results from those studies suggested that there may be differences in the crystallization behavior between glasses prepared in crucible melts and those prepared in DuraMelter 100 (DM100) joule heated melter runs. Understanding the cause of those differences has the potential to lead to the development of methods to further increase waste loadings for high chromium HLW streams through control of the formation of chromium-bearing crystals. As noted previously, the potential causes include differences in the form of components in the batch, including the form of chromium, as well as redox effects. This report describes the results from work to elucidate the origins of the observed differences and to identify melter feed composition modifications to control the formation of chromium-bearing crystal phases. The work focused on determining the effects of the form of chromium and the concentrations of oxidants in feed batches on spinel crystallization. Also evaluated was the use of potential melter feed additives to influence the redox state of chromium in the melt and its effect on spinel crystallization. As described in the Test Plan for this work, the objectives were accomplished through a combination of crucible-scale tests, small-scale tests with additives to influence redox state, and melter tests. This work builds on previous work performed at the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) for ORP to increase the waste loadings and processing rates of HLW glass formulations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVANNAH RIVER SITE ENVIRONMENTAL REPORT FOR 2009

The Savannah River Site Environmental Report for 2009 (SRNS-STI-2010-00175) is prepared for the U.S. Department of Energy (DOE) according to requirements of DOE Order 231.1A,'Environment, Safety and Health Reporting,' and DOE Order 5400.5, 'Radiation Protection of the Public and Environment.' The annual SRS Environmental Report has been produced for more than 50 years. Several hundred copies are distributed each year to government officials, universities, public libraries, environmental and civic groups, news media, and interested individuals. The report's purpose is to: (1) present summary environmental data that characterize site environmental management performance; (2) confirm compliance with environmental standards and requirements; and (3) highlight significant programs and efforts. SRS maintained its record of environmental excellence in 2009, as its operations continued to result in minimal impact to the offsite public and the surrounding environment. The site's radioactive and chemical discharges to air and water were well below regulatory standards for environmental and public health protection; its air and water quality met applicable requirements; and the potential radiation dose from its discharges was less than the national dose standards. The largest radiation dose that an offsite, hypothetical, maximally exposed individual could have received from SRS operations during 2009 was estimated to be 0.12 millirem (mrem). (An mrem is a standard unit of measure for radiation exposure.) The 2009 SRS dose is just 0.12 percent of the DOE all-pathway dose standard of 100 mrem per year, and far less than the natural average dose of about 300 mrem per year (according to Report No. 160 of the National Council of Radiation Protection and Measurements) to people in the United States. This 2009 all-pathway dose of 0.12 mrem was the same as the 2008 dose. Environmental monitoring is conducted extensively within a 2,000-square-mile network extending 25 miles from SRS, with some monitoring performed as far as 100 miles from the site. The area includes neighboring cities, towns, and counties in Georgia and South Carolina. Thousands of samples of air, rainwater, surface water, drinking water, groundwater, food products, wildlife, soil, sediment, and vegetation are collected by SRS and state authorities and analyzed for the presence of radioactive and nonradioactive contaminants. Compliance with environmental regulations and with DOE orders related to environmental protection provides assurance that onsite processes do not impact the public or the environment adversely. Such compliance is documented in this report. SRS had a National Pollutant Discharge Elimination System (NPDES) compliance rate of 99.92 percent in 2009, with only four of the 4,989 sample analyses performed exceeding permit limits. The NPDES program protects streams, reservoirs, and other wetlands by limiting the release of nonradiological pollution into surface waters. Discharge limits are set for each facility to ensure that SRS operations do not negatively impact aquatic life or degrade water quality.

54 ENVIRONMENTAL SCIENCES↗

Third-Party Aggregation Rulemaking in MISO and SPP Footprints

The report highlights key considerations for retail regulators in the footprints of the Southwest Power Pool (SPP) or Midcontinent Independent System Operator (MISO) in states that previously opted out of allowing third-party aggregation participation under FERC Order 719 and that may want to explore reversing the decision due to a changing policy environment under new FERC orders (i.e., 2222) and/or tightening resource adequacy constraints. Through a document review and a series of 27 interviews with regulators, aggregators, and other industry professionals, this document provides a high-level policy overview of the retail regulator’s role in a selection of processes, rules, and regulations to better understand how states have treated and/or integrated aggregators into wholesale markets. The report summarizes findings in two sections: General Findings and Specific Policy Findings. The General Findings offer high level takeaways such as the fact that 17 of the 20 states in MISO and SPP footprints opted out of third party aggregations following Order 719. Additionally, there is only one state that is fully restructured in the MISO and SPP footprints whereas the rest are vertically integrated, and the majority of third-party aggregations in the U.S. take place in restructured states outside of these footprints. Even so, third-party aggregations do take place in MISO and SPP albeit in small numbers and in an ad hoc regulatory environment. The specific policy findings delve deeper into specific examples of state actions on the topics of jurisdiction, registration and licensing, data governance, dual participation, and dispute resolution. Tables in each category organize state actions into Tiers I-III, which roughly correspond to the possible level of involvement or possible change necessary by state regulators and/or legislators to implement these actions. The tier level does not indicate any value judgement, as each state has respective regulatory limitations and each decision comes with various tradeoffs. One main tradeoff is between simplicity and quick implementation versus comprehensive and prolonged implementation. In many cases, actions in Tier I could be implemented without significant changes by relying on the use of existing processes for an aggregator context. On the other hand, many actions in Tier III are more narrowly designed to address aggregators specifically, but often require more significant changes including the involvement of additional parties through stakeholder engagement or legislative action. In some cases, these tiers are discrete. However, state regulators may also choose to progress through these various tiers sequentially as they phase in aggregators while learning from their experience. With the ability to stack bulk system level services, distributed energy resource aggregations in MISO and SPP could provide various private benefits (e.g., increased value streams to the owner) as well as societally beneficial grid services (e.g., peaking capacity, ancillary services, and other services that increase the grid’s overall operational efficiency). In deciding how to best to enable these benefits, states and retail regulators must weigh various tradeoffs if considering reversing a previous opt out.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The MicroBooNE continuous readout stream for detection of supernova neutrinos

Since the original detection of core-collapse supernova neutrinos in 1987, all large neutrino experiments seek to detect the neutrinos from the next nearby supernova. Among them, liquid argon time projection chambers (LArTPCs) offer a unique sensitivity to the electron neutrino flux of a supernova. However, the low energy of these events (scale of MeVs), and the fact that all large (multi-tonne) LArTPCs operating at the moment are located near the Earth's surface, and are therefore subject to an intense cosmic ray flux, makes triggering on the supernova neutrinos very challenging. Instead, MicroBooNE has pioneered a novel approach for detecting supernova neutrinos based on a continuous readout stream and a delayed trigger generated by other neutrino detectors (the Supernova Early Warning System, or SNEWS). MicroBooNE's data is stored temporarily for a few days, awaiting a SNEWS alert to prompt the permanent recording of the data. In order to cope with the large data rates produced by the continuous readout of the TPC and the PMT systems of MicroBooNE, FPGA-based zero-suppression algorithms have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rate-based process modeling study of CO{sub 2} capture with aqueous monoethanolamine solution

Rate-based process modeling technology has matured and is increasingly gaining acceptance over traditional equilibrium-stage modeling approaches. Recently comprehensive pilot plant data for carbon dioxide (CO{sub 2}) capture with aqueous monoethanolamine (MEA) solution have become available from the University of Texas at Austin. The pilot plant data cover key process variables including CO{sub 2} concentration in the gas stream, CO{sub 2} loading in lean MEA solution, liquid to gas ratio, and packing type. In this study, we model the pilot plant operation with Aspen RateSep, a second generation rate-based multistage separation unit operation model in Aspen Plus. After a brief review of rate-based modeling, thermodynamic and kinetic models for CO{sub 2} absorption with the MEA solution, and transport property models, we show excellent match of the rate-based model predictions against the comprehensive pilot plant data and we validate the superiority of the rate-based models over the traditional equilibrium-stage models. We further examine the impacts of key rate-based modeling options, i.e., film discretization options and flow model options. The rate-based model provides excellent predictive capability, and it should be very useful for design and scale-up of CO{sub 2} capture processes.

01 COAL, LIGNITE, AND PEAT↗

Integrated Multi-Scale Data Analytics and Machine Learning for the Distribution Grid

We consider the field of machine learning and where it is both useful, and not useful, for the distribution grid and buildings interface. While analytics, in general, is a growing field of interest, and often seen as the golden goose in the burgeoning distribution grid industry, its application is often limited by communications infrastructure, or lack of a focused technical application. Overall, the linkage of analytics to purposeful application in the grid space has been limited. In this paper we consider the field of machine learning as a subset of analytical techniques, and discuss its ability and limitations to enable the future distribution grid. To that end, we also consider the potential for mixing distributed and centralized analytics and the pros and cons of these approaches. There is an exponentially expanding volume of measured data being generated on the distribution grid, which, with appropriate application of analytics, may be transformed into intelligible, actionable information that can be provided to the right actors - such as grid and building operators, at the appropriate time to enhance grid or building resilience, efficiency, and operations against various metrics or goals - such as total carbon reduction or other economic benefit to customers. While some basic analysis into these data streams can provide a wealth of information, computational and human boundaries on performing the analysis are becoming significant, with more data and multi-objective concerns. Efficient applications of analysis and the machine learning field are being considered in the loop. This paper describes benefits and limits of present machine-learning applications for use on the grid and presents a series of case studies that illustrate the potential benefits of developing advanced local multi-variate analytics machine-learning-based applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AmeriFlux US-Ha3 Harvard Forest Beaver Swamp

This is the AmeriFlux version of the carbon flux data for the site US-Ha3 Harvard Forest Beaver Swamp. Site Description - This now-wetland site was flooded in the early 2000s due to beaver activity. It is fed by a stream. The tower is located near the swamp's outflow, and is approximately 250 m away from US-Ha1, which has been in operation since 1990. The area was cleared for agriculture in the 17th and 18th centuries.

Harvey, Charles [Massachusetts Institute of Techno↗

Mixed Stream Test Rig (MISTER) Startup Report

This report describes the work accomplished to date to design, procure, assemble, authorize, and startup the Mixed Stream Test Rig (MISTER) at the Idaho National Laboratory (INL). It describes the reasons for establishing this capability, physical configuration of the test equipment, operations methodology, initial success, and plans for completing the initial 1,000 hour test.

08 HYDROGEN↗

Integrated Multi-Scale Data Analytics and Machine Learning for the Distribution Grid and Building-to-Grid Interface

This white paper introduces the application of advanced data analytics to the modernized grid. In particular, we consider the field of machine learning and where it is both useful, and not useful, for the particular field of the distribution grid and buildings interface. While analytics, in general, is a growing field of interest, and often seen as the golden goose in the burgeoning distribution grid industry, its application is often limited by communications infrastructure, or lack of a focused technical application. Overall, the linkage of analytics to purposeful application in the grid space has been limited. In this paper we consider the field of machine learning as a subset of analytical techniques, and discuss its ability and limitations to enable the future distribution grid and the building-to-grid interface. To that end, we also consider the potential for mixing distributed and centralized analytics and the pros and cons of these approaches. Machine learning is a subfield of computer science that studies and constructs algorithms that can learn from data and make predictions and improve forecasts. Incorporation of machine learning in grid monitoring and analysis tools may have the potential to solve data and operational challenges that result from increasing penetration of distributed and behind-the-meter energy resources. There is an exponentially expanding volume of measured data being generated on the distribution grid, which, with appropriate application of analytics, may be transformed into intelligible, actionable information that can be provided to the right actors – such as grid and building operators, at the appropriate time to enhance grid or building resilience, efficiency, and operations against various metrics or goals – such as total carbon reduction or other economic benefit to customers. While some basic analysis into these data streams can provide a wealth of information, computational and human boundaries on performing the analysis are becoming significant, with more data and multi-objective concerns. Efficient applications of analysis and the machine learning field are being considered in the loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wabash CarbonSAFE (Subtask 3.1 - Application of the NRAP Tools to the Wabash CarbonSAFE Site for Risk Assessment Associated with Geologic Carbon Storage Activities)

This report documents a risk assessment of CO 2 containment loss and induced shear failure due to geologic carbon storage at the Wabash CarbonSAFE site. The operator, Wabash Valley Resources, has proposed adapting the onsite integrated gasification combined cycle (IGCC) facilities to produce hydrogen and injecting the byproduct CO 2 stream into the subsurface Potosi dolomite formation. The purpose of this study is to assess (1) CO 2 sequestration performance relative to the CarbonSAFE goals of storing 50 Mt over 30 years, (2) the risk of containment loss due to leakage along a wellbore and into an overlying aquifer, and (3) the state of stress and risk of reactivating existing fractures. This study relied upon the initial site characterization work performed by the Illinois State Geologic Survey (ISGS) along with analogue data collected from other carbon sequestration projects in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Vortex combustor for low NOx emissions when burning lean premixed high hydrogen content fuel

A trapped vortex combustor. The trapped vortex combustor is configured for receiving a lean premixed gaseous fuel and oxidant stream, where the fuel includes hydrogen gas. The trapped vortex combustor is configured to receive the lean premixed fuel and oxidant stream at a velocity which significantly exceeds combustion flame speed in a selected lean premixed fuel and oxidant mixture. The combustor is configured to operate at relatively high bulk fluid velocities while maintaining stable combustion, and low NOx emissions. The combustor is useful in gas turbines in a process of burning synfuels, as it offers the opportunity to avoid use of diluent gas to reduce combustion temperatures. The combustor also offers the possibility of avoiding the use of selected catalytic reaction units for removal of oxides of nitrogen from combustion gases exiting a gas turbine.

42 ENGINEERING↗

Vortex combustor for low NOX emissions when burning lean premixed high hydrogen content fuel

A trapped vortex combustor. The trapped vortex combustor is configured for receiving a lean premixed gaseous fuel and oxidant stream, where the fuel includes hydrogen gas. The trapped vortex combustor is configured to receive the lean premixed fuel and oxidant stream at a velocity which significantly exceeds combustion flame speed in a selected lean premixed fuel and oxidant mixture. The combustor is configured to operate at relatively high bulk fluid velocities while maintaining stable combustion, and low NOx emissions. The combustor is useful in gas turbines in a process of burning synfuels, as it offers the opportunity to avoid use of diluent gas to reduce combustion temperatures. The combustor also offers the possibility of avoiding the use of selected catalytic reaction units for removal of oxides of nitrogen from combustion gases exiting a gas turbine.

47 OTHER INSTRUMENTATION↗

Melter Downtime Impacts on DFLAW Glass Production and Process Efficiency - 17117

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) pilot studies found that semi-volatile elements started to leave the molten glass pool and enter the offgas stream when the melter became idle. The rate at which the semi-volatile elements leave the molten glass pool follows a typical half-life decay curve. The WTP Direct Feed Low-Activity Waste (DFLAW) program is using existing LAW offgas treatment systems to capture semi-volatile elements leaving the melters. A new building, Effluent Management Facility (EMF), will be built to process effluents generated by the offgas treatment equipment. The effluents are concentrated by evaporation and are recycled to the melter feed streams. Computer modeling studies show that increased amounts of semi-volatile elements in the recycles due to melter downtime adversely impact the DFLAW operations. The extent to which glass productions and process efficiencies are hampered depends upon the frequency, duration, and pattern of the downtime events. Various scenarios were investigated using randomly generated and operator-anticipated downtime schedules. This paper discusses 1) derivation of the volatility half-life curves, 2) downtime schedules, 3) increased amount of semi-volatile elements in recycled material as a result of melter shut down, 4) impacts to glass production and process efficiency, and 5) comparison of scenario results. This study concludes that plant operators can mitigate much of the negative effects of semi-volatile element recycles by managing melter downtime and idle time when possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FEMO, A FLOW AND ENRICHMENT MONITOR FOR VERIFYING COMPLIANCE WITH INTERNATIONAL SAFEGUARDS REQUIREMENTS AT A GAS CENTRIFUGE ENRICHMENT FACILITY

A number of countries have received construction licenses or are contemplating the construction of large-capacity gas centrifuge enrichment plants (GCEPs). The capability to independently verify nuclear material flows is a key component of international safeguards approaches, and the IAEA does not currently have an approved method to continuously monitor the mass flow of 235U in uranium hexafluoride (UF6) gas streams. Oak Ridge National Laboratory is investigating the development of a flow and enrichment monitor, or FEMO, based on an existing blend-down monitoring system (BDMS). The BDMS was designed to continuously monitor both 235U mass flow and enrichment of UF6 streams at the low pressures similar to those which exists at GCEPs. BDMSs have been installed at three sites-the first unit has operated successfully in an unattended environment for approximately 10 years. To be acceptable to GCEP operators, it is essential that the instrument be installed and maintained without interrupting operations. A means to continuously verify flow as is proposed by FEMO will likely be needed to monitor safeguards at large-capacity plants. This will enable the safeguards effectiveness that currently exists at smaller plants to be maintained at the larger facilities and also has the potential to reduce labor costs associated with inspections at current and future plants. This paper describes the FEMO design requirements, operating capabilities, and development work required before field demonstration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding the impact of flow rate and recycle on the conversion of a complex biorefinery stream using a flow-through microbial electrolysis cell

We investigated the effect of flow rate and recycle on the conversion of a biomass-derived pyrolysis aqueous phase in amicrobial electrolysis cell (MEC) to demonstrate production of renewable hydrogen in biorefinery. A continuous MEC operation was investigated under one-pass and recycle conditions usingthe complex, biomass-derived, fermentable, mixed substrate feed at a constant concentration of 0.026 g/L,while testing flow rates ranging from 0.19 to 3.6 mL/min. This corresponds to an organic loading rate (OLR) of 0.54₋10 g/L-day. Mass transfer issues observed at low flow rates were alleviated using high flow rates.Increasing the flow rate to 3.6 mL/min (3.7 min HRT) during one-pass operation increased the hydrogen productivity 3-fold, but anode conversion efficiency (ACE) decreased from 57.9% to 9.9%. Recycle of the anode liquid helped to alleviate kinetic limitations and the ACE increased by 1.8-fold and the hydrogen productivity by 1.2-fold compared to the one-pass condition at the flow rate of 3.6 mL/min (10 g/L-d OLR). High COD removal was also achieved under recycle conditions, reaching 74.2 1.1%, with hydrogen production rate of 2.92 ± 0.51 L/L-day. This study demonstrates the advantages of combining faster flow rates with a recycle process to improve rate of hydrogen production from a switchgrass-derived stream in the biorefinery.

08 HYDROGEN↗

Tritium Distribution and Capture Requirements for UNF Reprocessing

Four radionuclides have been identified as being sufficiently volatile in reprocessing of nuclear fuel that their gaseous release needs to be controlled to meet U.S. regulatory requirements. These radionuclides are {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I. Previous studies have discussed the need for treating off-gas streams to control {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I from the reprocessing of used nuclear fuel (UNF) and the regulations that set the limits for releases from such a facility. These regulations ultimately prescribe the decontamination factor (DF) that must be met in the facility. Jubin et al. examined the role of off-gas pathways since the gaseous radionuclides can partition to different reprocessing off-gas streams. Based on this report and subsequent analysis, the required DF for {sup 129}I could be 1000 to 3000. The required DF for {sup 3}H could be as high as 200, depending on the age of the fuel processed. The DF for {sup 85}Kr could be up to ∼35, also depending on fuel age. The required DF for {sup 14}C is 1 in many cases (no treatment required) but could be higher in specific cases. While iodine has been the focus of a number of studies due to the high DF requirements on multiple escape pathways, it is clear from the studies noted above that the control of tritium will also be a significant issue for future reprocessing plants, especially if processing relatively short-cooled fuels (<10 yr post reactor discharge). Tritium contained in a UNF matrix will be released into the liquid and off-gas streams during fuel reprocessing. The amount released into the process streams is a function of the type and burnup of the fuel processed, and the chemical processes employed within the reprocessing plant. Previous studies have examined the tritium capture requirements for the reprocessing facility assuming that all of the tritium is volatilized in the head-end operations, i.e., tritium pretreatment is employed and tritium is completely released from the cladding. This is clearly a worst case scenario from the standpoint of the amount of tritium that could be released, but the scenario tends to limit the release pathway to the head-end off-gas stream. In this analysis, the volume of HTO and the HTO to H{sub 2}O ratio for each of the three plant-wide tritium DFs were determined. The overall amount of HTO that had to be captured from the off-gas streams was virtually the same for the three DF cases evaluated; 98%, 99% and 99.5% of the tritium in the fuel entering the plant needed to be recovered for overall plant DFs of 50, 100 and 200, respectively. The use of the 'tritium barrier' to limit the spread of HTO from the head-end systems to the balance of the plant results in an increase in tritiated waste concentration in the head-end recycle acid systems which results in a decrease in the total amount of HTO + H{sub 2}O that must recovered from the gaseous effluent from the plant. The use of the 'tritium barrier' decreases the waste volume due to the higher HTO:H{sub 2}O ratio in the treated off-gas stream. The results also show that increasing the acid recycle percentage increases the concentration of HTO within the UNF reprocessing plant. This is then manifested in less HTO + H{sub 2}O that must be recovered from the gaseous effluents. Finally, the application of tritium recovery on the recycle acid reduces the HTO concentration in the recycle acid stream and generates a separate HTO + H{sub 2}O stream that must be managed. However, the resulting volume of tritium-containing waste generated plant-wide is a function of the selectivity of the tritium recovery system and the ability of the tritium recovery system to limit the accumulation of HTO in the recycle acid such that the HTO + H{sub 2}O recovered from gaseous effluents does not contribute significantly to the overall tritium waste volume. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗