Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration

Highlights: • Intact AQP0 functions as fiber cell-to-fiber cell adhesion protein. • AQP0 facilitates reduction in extracellular space and lens water content. • AQP0 adhesion function aids in lens refractive index gradient (RING) formation. • AQP0 prevents lens spherical aberration by establishing RING. • AQP0 is critical for lens transparency and homeostasis. - Abstract: Aquaporin 0 (AQP0) is a transmembrane channel that constitutes ∼45% of the total membrane protein of the fiber cells in mammalian lens. It is critical for lens transparency and homeostasis as mutations and knockout cause autosomal dominant lens cataract. AQP0 functions as a water channel and as a cell-to-cell adhesion (CTCA) molecule in the lens. Our recent in vitro studies showed that the CTCA function of AQP0 could be crucial to establish lens refractive index gradient (RING). However, there is a lack of in vivo data to corroborate the role of AQP0 as a fiber CTCA molecule which is critical for creating lens RING. The present investigation is undertaken to gather in vivo evidence for the involvement of AQP0 in developing lens RING. Lenses of wild type (WT) mouse, AQP0 knockout (heterozygous, AQP0{sup +/−}) and AQP0 knockout lens transgenically expressing AQP1 (heterozygous AQP0{sup +/−}/AQP1{sup +/−}) mouse models were used for the study. Data on AQP0 protein profile of intact and N- and/or C-terminal cleaved AQP0 in the lens by MALDI-TOF mass spectrometry and SDS–PAGE revealed that outer cortex fiber cells have only intact AQP0 of ∼28 kDa, inner cortical and outer nuclear fiber cells have both intact and cleaved forms, and inner nuclear fiber cells have only cleaved forms (∼26–24 kDa). Knocking out of 50% of AQP0 protein caused light scattering, spherical aberration (SA) and cataract. Restoring the lost fiber cell membrane water permeability (P{sub f}) by transgene AQP1 did not reinstate complete lens transparency and the mouse lenses showed light scattering and SA. Transmission and scanning electron micrographs of lenses of both mouse models showed increased extracellular space between fiber cells. Water content determination study showed increase in water in the lenses of these mouse models. In summary, lens transparency, CTCA and compact packing of fiber cells were affected due to the loss of 50% AQP0 leading to larger extracellular space, more water content and SA, possibly due to alteration in RING. To our knowledge, this is the first report identifying the role of AQP0 in RING development to ward off lens SA during focusing.

60 APPLIED LIFE SCIENCES↗

Tailoring seed oil composition in the real world: optimising omega-3 long chain polyunsaturated fatty acid accumulation in transgenic Camelina sativa

There is considerable interest in the de novo production of omega-3 long chain polyunsaturated fatty acids such as eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), not least of all given the importance of these fatty acids in both aquaculture and human nutrition. Previously we have demonstrated the feasibility of using metabolic engineering in transgenic plants (Camelina sativa) to modify the seed oil composition to now include EPA and/or DHA. In this study, we further tailored the seed oil profile to reduce the omega-6 content, and evaluated the performance of such GM plants under field conditions (i.e. environmental releases), in terms of agronomic performance and also the lipidomic profile of seed oil. We used MALDI- mass spectrometry imaging to identify discrete tissue-types in the seed in which these non-native fatty acids preferentially accumulated. Collectively, these data provide new insights into the complexity of plant lipid metabolism and the challenges associated with predictive manipulation of these pathways. However, this study identified the likely dispensable nature of a Δ12-desturase activity in our omega-3 metabolic engineering rationales for Camelina.

16 TIDAL AND WAVE POWER↗

BF{sub 3} PIII modeling: Implantation, amorphisation and diffusion

In the race for highly doped ultra-shallow junctions (USJs) in complementary metal oxide semi-conductor (CMOS) technologies, plasma immersion ion implantation (PIII) is a promising alternative to traditional beamline implantation. Currently, no commercial technology computer aided design (TCAD) process simulator allows modeling the complete USJ fabrication process by PIII, including as-implanted dopant profiles, damage formation, dopant diffusion and activation. In this work, a full simulation of a p-type BF{sub 3} PIII USJ has been carried out. In order to investigate the various physical phenomena mentioned above, process conditions included a high energy/high dose case (10 kV, 5 Multiplication-Sign 10{sup 15} cm{sup -2}), specifically designed to increase damage formation, as well as more technology relevant implant conditions (0.5 kV) for comparison. All implanted samples were annealed at different temperatures and times. As implanted profiles for both boron and fluorine in BF{sub 3} implants were modeled and compared to Secondary Ion Mass Spectrometry (SIMS) measurements. Amorphous/crystalline (a/c) interface depths were measured by transmission electron microscopy (TEM) and successfully simulated. Diffused profiles simulations agreed with SIMS data at low thermal budgets. A boron peak behind the a/c interface was observed in all annealed SIMS profiles for the 10 kV case, indicating boron trapping from EOR defects in this region even after high thermal budgets. TEM measurements on the annealed samples showed an end of range (EOR) defects survival behind the a/c interface, including large dislocation loops (DLs) lying on (001) plane parallel to the surface. In the last part of this work, activation simulations were compared to Hall measurements and confirmed the need to develop a (001) large BICs model.

36 MATERIALS SCIENCE↗

Energy Expenditure Upon the Formation of the Elastically Stressed State in the Layers of a Step-Graded Metamorphic Buffer in a Heterostructure Grown on a (001) GaAs Substrate

On the basis of data on X-ray structural analysis performed by the method of reciprocal-space mapping and investigations using secondary-ion mass spectrometry and transmission electron microscopy, it is shown that vertical compressive stresses also arise in a multilayer epitaxial heterostructure comprised of a step-graded metamorphic buffer along with lateral compressive stresses. The cause of the appearance of vertical stresses is the effect of interlayer hardening, which arises due to the deceleration of fragments of glide dislocations by interphase boundaries. Analysis performed within the framework of the linear theory of elasticity shows that the elastically stressed state of the buffer steps is similar to the state that can be achieved as a result of a two-stage deformation process: bulk and biaxial compression. Bulk compression leads to large energy expenditures in the formation of the structure of the buffer steps, which is reflected, in particular, in violation of the coherence between the dislocation-free and the underlying layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A New Limitation of the Depth Resolution in TOF-SIMS Elemental Profiling: the Influence of a Probing Ion Beam

New data concerning the influence of a probing beam of bismuth ions on the depth resolution in elemental depth profiling by secondary ion mass spectrometry (SIMS) have been obtained on a TOF.SIMS-5 system using the principle of two separate ion beams. It is established that the existing criterion of nondestructive character of the probing beam, on which this principle is based, is insufficient. Additional processes must be taken into account so as to formulate a more adequate criterion. A regime of depth profiling is proposed that allows the depth resolution to be improved at low energies of sputtering ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.

47 OTHER INSTRUMENTATION↗

Passively Sampled Environmental Films Show Geographic Variability and Host a Variety of Microorganisms

Environmental films are ubiquitous coatings that form on virtually all surfaces exposed to the troposphere. This work analyzes large molecular weight species in native environmental films acquired at three collection sites in the vicinity of Iowa City, Iowa, USA that include an urban residence, a wooded area, and a metropolitan building rooftop. The films are developed for up to twelve months on polished silicon wafer substrates housed in flat-plate passive samplers. Film composition was assessed by Fourier transform ion cyclotron resonance secondary ion mass spectrometry (FTICR-SIMS), and spatially resolved chemical morphology was analyzed via timeof- flight secondary ion mass spectrometry (ToF-SIMS) imaging. Mass analysis spanning up to m/z 2,000 included detection of a variety of organic and inorganic compounds. We characterize MS data with PCA to identify variability between the collection sites and the respective films generated therein, where we detected a variety of organic and biotically generated species consistent with fungal and bacterial microorganisms. Here, the film collection site as well as deposition time contribute to spectral variability, suggesting that geographic location as well as seasonal diversity may affect composition. SIMS analyses were complemented with microscopy and SYBR-Safe staining to highlight biological microorganisms within the films, which include evidence of fungi, protozoa, and bacteria. SIMS imaging also reveals domains concentrated with fragments indicative of proteinaceous macromolecules and microbial biomass, characteristic of biological presence within the film.

42 ENGINEERING↗

Mass spectrometry in the U.S. space program: past, present, and future

Recent years have witnessed significant progress on the miniaturization of mass spectrometers for a variety of field applications. This article describes the development and application of mass spectrometry (MS) instrumentation to support of goals of the U.S. space program. Its main focus is on the two most common space-related applications of MS: studying the composition of planetary atmospheres and monitoring air quality on manned space missions. Both sets of applications present special requirements in terms of analytical performance (sensitivity, selectivity, speed, etc.), logistical considerations (space, weight, and power requirements), and deployment in perhaps the harshest of all possible environments (space). The MS instruments deployed on the Pioneer Venus and Mars Viking Lander missions are reviewed for the purposes of illustrating the unique features of the sample introduction systems, mass analyzers, and vacuum systems, and for presenting their specifications which are impressive even by today's standards. The various approaches for monitoring volatile organic compounds (VOCs) in cabin atmospheres are also reviewed. In the past, ground-based GC/MS instruments have been used to identify and quantify VOCs in archival samples collected during the Mercury, Apollo, Skylab, Space Shuttle, and Mir missions. Some of the data from the more recent missions are provided to illustrate the composition data obtained and to underscore the need for instrumentation to perform such monitoring in situ. Lastly, the development of two emerging technologies, Direct Sampling Ion Trap Mass Spectrometry (DSITMS) and GC/Ion Mobility Spectrometry (GC/IMS), will be discussed to illustrate their potential utility for future missions. c 2001 American Society for Mass Spectrometry.

NASA Discipline Environmental Health↗

A resource of lipidomics and metabolomics data from individuals with undiagnosed diseases

Every year individuals experience symptoms that remain undiagnosed by healthcare providers. In the United States, these rare diseases are defined as a condition that affects fewer than 200,000 individuals. However, there are an estimated 7000 rare diseases, and there are an estimated 25–30 million Americans in total (7.6–9.2% of the population as of 2018) affected by such disorders. The NIH Common Fund Undiagnosed Diseases Network (UDN) seeks to provide diagnoses for individuals with undiagnosed disease. Mass spectrometry-based metabolomics and lipidomics analyses could advance the collective understanding of individual symptoms and advance diagnoses for individuals with heretofore undiagnosed disease. Here, we report the mass spectrometry-based metabolomics and lipidomics analyses of blood plasma, urine, and cerebrospinal fluid from 148 patients within the UDN and their families, as well as from a reference population of over 100 individuals with no known metabolic diseases. The raw and processed data are available to the research community so that they might be useful in the diagnoses of current or future patients suffering from undiagnosed disorders.

60 APPLIED LIFE SCIENCES↗

Stable Chlorine Isotope Measurements of Astromaterials Using the Cs-Sputter Negative Ion Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) [1] are documented to exceed 80‰ [2] between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history[3,4].The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements (Figure 1).This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the Cs-sputter negative ion source of an existing accelerator mass spectrometer. A brief description of the methods used for this work is followed by the results of our δ37Cl measurements and a discussion of the technique’s possible applications.

Chlorine↗

The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)

The next-generation magnetic recoil spectrometer for time-resolved measurements of the neutron spectrum has been conceptually designed for the National Ignition Facility. This spectrometer, called MRSt, represents a paradigm shift in our thinking about neutron spectrometry for inertial confinement fusion applications, as it will provide simultaneously information about the burn history and time evolution of areal density (ρR), apparent ion temperature (T{sub i}), yield (Y{sub n}), and macroscopic flows during burn. From this type of data, an assessment of the evolution of the fuel assembly, hotspot, and alpha heating can be made. According to simulations, the MRSt will provide accurate data with a time resolution of ∼20 ps and energy resolution of ∼100 keV for total neutron yields above ∼10{sup 16}. At lower yields, the diagnostic will be operated at a higher-efficiency, lower-energy-resolution mode to provide a time resolution of ∼20 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soil microbial ecology and microbiome-metabolite linkages improve understanding of ecosystem states along terrestrial-aquatic interfaces

These data are from Bandopadhyay et al., "Soil microbial ecology and microbiome-metabolite linkages improve understanding of ecosystem states along terrestrial-aquatic interfaces". This study aims to understand the soil microbial ecology along terrestrial-aquatic interfaces of a freshwater and estuarine region and how it relates to organic matter. We analyzed soil microbial (16S rRNA gene) and organic matter (Fourier-transform ion cyclotron resonance mass spectrometry, FTICR-MS) composition from upland (forested), transition (stressed forest), and wetland positions at three sites in each of the Lake Erie (freshwater) and Chesapeake Bay (estuarine) regions. This dataset includes 16S rRNA gene amplicon data (only processed file types included here) and organic matter composition from FTICR-MS data (raw and processed files included here) from upland (forested), transition (stressed forest), and wetland positions at three sites in each of the Lake Erie and Chesapeake Bay regions. These sites are part of the COMPASS-FME project (https://compass.pnnl.gov/FME/COMPASSFME). File formats and software needed to access files: 16S rRNA gene amplicon data: These files follow the format reported here https://ess-dive.gitbook.io/amplicon-sequencing-reporting-format#updates-in-v1.0.1. As per this format, there are four file types reported: 1. Taxon tables (also called sequence-by-sample or OTU (operational taxonomic unit)/ESV (exact sequence variant) tables) : available in a .txt file format and accessible using TextEdit or MS Excel. 2. Representative sequences (also called consensus sequences) : available in a .fasta format and accessible using TextEdit. 3. Sequencing metadata : available in a MS Excel workbook file format and CSV file format 4. Bioinformatic metadata : available in a MS Excel workbook file format and CSV file format FTICR-MS data: 1. Raw data converted to a processed file with intensities of the peaks in the given samples : available in a MS Excel CSV file format 2. Processed file used in analyses and visualizations (appended as icr_long_) : available in a MS Excel CSV file format 3. Metadata file for ICR features (appended as icr_meta) : available in a MS Excel CSV file format

54 ENVIRONMENTAL SCIENCES↗

Investigation of the potential ultralow Q-value β-decay candidates 89 Sr and 139 Ba using Penning trap mass spectrometry

Background: Ultralow Q-value β decays are interesting processes to study with potential applications to nuclear β-decay theory and neutrino physics. While a number of potential ultralow Q-value β-decay candidates exist, improved mass measurements are necessary to determine which of these are energetically allowed. Purpose: To perform precise atomic mass measurements of 89 Y and 139 La. Use these new measurements along with the precisely known atomic masses of 89 Sr and 139 Ba and nuclear energy level data for 89 Y and 139 La to determine if there could be an ultralow Q-value decay branch in the β decay of 89 Sr → 89 Y or 139 Ba → 139 La. Method: High-precision Penning trap mass spectrometry was used to determine the atomic mass of 89 Y and 139 La, from which β-decay Q values for 89 Sr and 139 Ba were obtained. Results: The 89 Sr → 89 Y and 139 Ba → 139 La β-decay Q values were measured to be Q Sr = 1502.20(0.35) keV and Q Ba = 2308.37(0.68) keV. These results were compared to energies of excited states in 89 Y at 1507.4(0.1) keV, and in 139La at 2310(19) keV and 2313(1) keV to determine Q values of -5.20(0.37) keV for the potential ultralow β-decay branch of 89 Sr and -1.6(19.0) keV and -4.6(1.2) keV for those of 139 Ba. Conclusion: The potential ultralow Q-value decay branch of 89 Sr to the 89 Y (3/2 - , 1507.4 keV) state is energetically forbidden and has been ruled out. The potential ultralow Q-value decay branch of 139 Ba to the 2313 keV state in 139 La with unknown J π has also been ruled out at the 4σ level, while more precise energy level data is needed for the 139 La (1/2 + , 2310 keV) state to determine if an ultralow Q-value β-decay branch to this state is energetically allowed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methodical Aspects of the Determination of Carbon Dioxide in Atmosphere Using FTIR Spectroscopy

Monitoring the state of ground-based spectroscopic systems ensures high accuracy of atmospheric gas composition measurements and the possibility of using measurement data for validating satellite measurements and numerical models. Column-averaged carbon dioxide mixing ratios (XCO{sub 2}) can be used to assess the quality of spectroscopic measurements because its content is stable in the atmosphere. The XCO{sub 2} values were retrieved from spectra measured by Fourier transform IR spectrometry (FTIR) using a Bruker 125HR instrument between 2009 and 2017 at the Peterhof station (St. Petersburg, Russia). The total error of the FTIR CO{sub 2} columns retrieval was 4.18 ± 0.02%, with 0.36 ± 0.06% and 4.16 ± 0.02% for random and systematic errors, respectively. The data obtained are compared with model calculations based on long-term observations at the Mauna Loa station. Various schemes solving for the inverse problem were analyzed and compared among themselves, and estimates of empirical random errors in the determination of XCO{sub 2} were obtained. To improve the accuracy of XCO{sub 2} measurements, it is recommended to determine the error of the Fourier-spectrometer phase and the slope of the zero line of the spectrum simultaneously with the atmospheric gas composition measurements taking into account various continuum sources of error.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High and Ultra-High Temperature Reaction Kinetics by Single Nanoparticle Mass Spectrometry

Methodology is presented for non-destructive, optically-detected single nanoparticle (NP) mass spectrometry, with the goal of extracting surface reaction kinetics for single NPs at high temperatures. Methods for determining the NP charge, mass, and temperature as a function of time are discussed, and the data are used to extract both the absolute kinetics for mass change, as well as the efficiencies of the surface processes that cause them. Factors that contribute to the uncertainties in absolute and relative mass determination, and in the resulting kinetic parameters, are discussed. The method allows the NP-to-NP variations in initial reactivity to be measured directly, along with the time evolution of reactivity resulting from NP structural/compositional changes that occur under reaction conditions. The strengths and limitations of single nanoparticle mass spectrometry as a high temperature surface kinetics tool are discussed in the context of sublimation and O2 oxidation kinetics experiments for single hafnium (Hf) NPs at temperatures ranging above 2400 K. The Hf oxidation kinetics are compared to analogous oxidation experiments for silicon, graphite, and carbon black NPs. In all four cases, the oxidation chemistry was dominated by processes that result in net mass loss, and the distinct mechanisms responsible are discussed. All four NPs also eventually passivated, i.e., the efficiencies for oxidative etching decreased by at least two orders of magnitude, relative to the initial efficiencies. Furthermore, the passivation mechanisms, which are quite different for carbon, compared to silicon or hafnium, are discussed. Carbon NP passivation is attributed to structural isomerization leading to fully coordinated, fullerene-like NP surfaces, while for silicon and hafnium, passivation results from delayed formation of an oxide layer, triggered by accumulation of oxygen in the NP sub-surface region.

36 MATERIALS SCIENCE↗

Spectrometry: Report of panel

Spectroscopic measurements are required to define the spectral background and provide the detailed spectral information that is essential for the design of species-specific systems and the analysis of data obtained from them. This function of spectroscopic measurements is expected to be an important part of any tropospheric remote-sensing program, and both emission and absorption spectroscopy are relevant in this context. The data from such observations are of value to tropospheric science in their own right, during the initial phases while species-specific techniques and instruments are under development. In addition, there are a number of unresolved problems in tropospheric radiative transfer and spectroscopy which presently limit the accuracy and reliability of all remote sensing methods. Only through a supporting program of spectroscopic measurements can progress be made in improving the understanding of these aspects of radiative transfer and ultimately reaching the desired confidence in the accuracy to species-specific monitoring techniques.

Farmer, C. Barney↗

Resolving Graphite‐Electrolyte Interphase of Lithium‐Ion Batteries using Air‐Tight Ambient Mass Spectrometry

Abstract The formation of a stable solid electrolyte interphase (SEI) at graphite electrode is necessary for lithium‐ion batteries (LIB) to prevent excessive degradation of electrolytes. Until now, the exact organic composition of SEI has not been decisively determined with lithium ethylene mono‐carbonate (LEMC) being one of the debated components. An air‐tight ambient mass spectrometry (MS) platform is developed to directly characterize the air‐sensitive organic components present in SEI. Ionization occurs via a solvent‐free field‐induced process at atmospheric pressure. Our experimental data, based on tandem MS analysis, revealed LEMC to be the major organic component in SEI. This result resolves a long‐standing mystery surrounding the composition of native SEI in LIB, where no trace of the other debated compound, lithium ethylene dicarbonate, was detected. The energetics of fragmentation of LEMC and the corresponding stabilities of various ionic species detected during the air‐tight ambient MS analysis were calculated using density functional theory (DFT). Our findings confirmed favorable protonation energies and suggested the molecular structures for many of the detected species. Solvent (i. e., ethylene carbonate)‐induced stabilization effects observed during the ionization process were also confirmed by DFT. The reported study encourages the routine use of ambient mass spectrometry to characterize both anodic and cathodic electrodes of all battery types as well as to study other air‐sensitive materials in their native state.

25 ENERGY STORAGE↗