Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Integrating Carbon Nanomaterials with Metals for Bio-sensing Applications

Age structure in most developed countries is changing fast as the average lifespan is increasing significantly, calling for solutions to provide improved treatments for age-related neurological diseases and disorders. In order to address these problems, a reliable way of recording information about neurotransmitters from in vitro and in vivo applications is needed to better understand neurological diseases and disorders as well as currently used treatments. Likewise, recent developments in medicine, especially with the opioid crisis, are demanding a swift move to personalized medicine to administer patient needs rather than population-wide averages. In order to enable the so-called personalized medicine, it is necessary to be able to do measurements in vivo and in real time. These actions require sensitive and selective detection of different analytes from very demanding environments. Current state-of-the-art materials are unable to provide sensitive and selective detection of neurotransmitters as well as the required time resolution needed for drug molecules at a reasonable cost. To meet these challenges, we have utilized different metals to grow carbon nanomaterials and applied them for sensing applications showing that there are clear differences in their electrochemical properties based on the selected catalyst metal. Additionally, we have combined atomistic simulations to support optimizing materials for experiments and to gain further understanding of the atomistic level reactions between different analytes and the sensor surface. With carbon nanostructures grown from Ni and Al + Co + Fe hybrid, we can detect dopamine, ascorbic acid, and uric acid simultaneously. On the other hand, nanostructures grown from platinum provide a feasible platform for detection of H 2 O 2 making them suitable candidates for enzymatic biosensors for detection of glutamate, for example. Tetrahedral amorphous carbon electrodes have an ability to detect morphine, paracetamol, tramadol, and O-desmethyltramadol. With carbon nanomaterial-based sensors, it is possible to reach metal-like properties in sensing applications using only a fraction of the metal as seed for the material growth. We have also seen that by using nanodiamonds as growth catalyst for carbon nanofibers, it is not possible to detect dopamine and ascorbic acid simultaneously, although the morphology of the resulting nanofibers is similar to the ones grown using Ni. This further indicates the importance of the metal selection for specific applications. However, Ni as a continuous layer or as separate islands does not provide adequate performance. Thus, it appears that metal nanoparticles combined with fiber-like morphology are needed for optimized sensor performance for neurotransmitter detection. This opens up a new research approach of application-specific nanomaterials, where carefully selected metals are integrated with carbon nanomaterials to match the needs of the sensing application in question.

59 BASIC BIOLOGICAL SCIENCES↗

Physical retrieval of precipitation water contents from Special Sensor Microwave/Imager (SSM/I) data. Part 1: A cloud ensemble/radiative parameterization for sensor response (report version)

The physical retrieval of geophysical parameters based upon remotely sensed data requires a sensor response model which relates the upwelling radiances that the sensor observes to the parameters to be retrieved. In the retrieval of precipitation water contents from satellite passive microwave observations, the sensor response model has two basic components. First, a description of the radiative transfer of microwaves through a precipitating atmosphere must be considered, because it is necessary to establish the physical relationship between precipitation water content and upwelling microwave brightness temperature. Also the spatial response of the satellite microwave sensor (or antenna pattern) must be included in the description of sensor response, since precipitation and the associated brightness temperature field can vary over a typical microwave sensor resolution footprint. A 'population' of convective cells, as well as stratiform clouds, are simulated using a computationally-efficient multi-cylinder cloud model. Ensembles of clouds selected at random from the population, distributed over a 25 km x 25 km model domain, serve as the basis for radiative transfer calculations of upwelling brightness temperatures at the SSM/I frequencies. Sensor spatial response is treated explicitly by convolving the upwelling brightness temperature by the domain-integrated SSM/I antenna patterns. The sensor response model is utilized in precipitation water content retrievals.

Olson, William S.↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Investigations of Association Among Atmospheric Radionuclide Measurements

Large networks producing frequent atmospheric radionuclide measurements have additional power in characterizing and localizing radionuclide release events over the analysis done with four or fewer samples. However, adding unrelated samples to an analysis dilutes that advantage, unless models are extended to account for this complexity. A key steppingstone to obtaining network power is to select a group of related sample measurements that are associated with a release event. Such collections of measurements can be assembled by an analyst, or perhaps they can be selected by algorithm. The authors explore, using a year of atmospheric transport calculations and realistic sensor sensitivities, the potential for a computed radionuclide association tool.

Eslinger, Paul W.↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Size-Selectively Biomolecule-Immobilized Nanoprobe-Based Chemiluminescent Lateral Flow Immunoassay for Detection of Avian-Origin Viruses

Here, a signal-amplifiable nanoprobe-based chemiluminescent lateral flow immunoassay (CL-LFA) was developed to detect avian influenza viruses (AIV) and other contagious and fatal viral avian-origin diseases worldwide. Signal-amplifiable nanoprobes are capable of size-selective immobilization of antibodies (binding receptors) and enzymes (signal transducers) on sensitive paper-based sensor platforms. Particle structure designs and conjugation pathways conducive for antigen accessibility to maximum amounts of immobilized enzymes and antibodies have advanced. The detection limit of the CL-LFA using the signal-amplifiable nanoprobe for the nucleoprotein of the H3N2 virus was 5 pM. Sensitivity tests for low pathogenicity avian influenza H9N2, H1N1, and high pathogenicity avian influenza H5N9 viruses were conducted, and the detection limits of CL-LFA were found to be 10 3.5 50% egg infective dose (EID 50 )/mL, 10 2.5 EID 50 /mL, and 10 4 EID 50 /mL, respectively, which is 20 to 100 times lower than that of a commercial AIV rapid test kit. Moreover, CL-LFA demonstrated high sensitivity and specificity against 37 clinical samples. The signal-amplifiable probe designed in this study is a potential diagnostic probe with ultrahigh sensitivity for applications in the field of clinical diagnosis, which requires sensitive antigen detection as evidenced by enhanced signaling capacity and sensitivity of the LFAs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Assessing Forest Level Response to the Death of a Dominant Tree within a Premontane Tropical Rainforest

Small-scale treefall gaps are among the most important forms of forest disturbance in tropical forests. These gaps expose surrounding trees to more light, promoting rapid growth of understory plants. However, the effects of such small-scale disturbances on the distribution of plant water use across tree canopy levels are less known. To address this, we explored plant transpiration response to the death of a large emergent tree, Mortoniodendron anisophyllum Standl. & Steyerm (DBH > 220 cm; height ~40 m). Three suppressed, four mid-story, and two subdominant trees were selected within a 50 × 44 m premontane tropical forest plot at the Texas A&M Soltis Center for Research and Education located in Costa Rica. We compared water use rates of the selected trees before (2015) and after (2019) the tree gap using thermal dissipation sap flow sensors. Hemispherical photography indicated a 40% increase in gap fraction as a result of changes in canopy structure after the treefall gap. Micrometeorological differences (e.g., air temperature, relative humidity, and vapor pressure deficit (VPD)) could not explain the observed trends. Rather, light penetration, as measured by sensors within the canopy, increased significantly in 2019. One year after the tree fell, the water usage of trees across all canopy levels increased modestly (15%). Moreover, average water usage by understory trees increased by 36%, possibly as a result of the treefall gap, exceeding even that of overstory trees. These observations suggest the possible reallocation of water use between overstory and understory trees in response to the emergent tree death. With increasing global temperatures and shifting rainfall patterns increasing the likelihood of tree mortality in tropical forests, there is a greater need to enhance our understanding of treefall disturbances that have the potential to redistribute resources within forests.

54 ENVIRONMENTAL SCIENCES↗

Application of a laser velocimeter for remote wind velocity and turbulence measurements.

Demonstration of the utility of a laser Doppler-type instrument for studying the velocity structure of atmospheric flow. Its value lies in the fact that regions of interest can be sensed remotely without introducing a perturbation at that location. The absence of moving mechanical parts results in a sensor with high frequency response capability. Regions of the atmosphere to be monitored can be selected simply by deflecting a mirror and adjusting the position of the focusing lens.

Lawrence, T. R.↗

The SEASAT-A synthetic aperture radar design and implementation

The SEASAT-A synthetic aperture imaging radar system is the first imaging radar system intended to be used as a scientific instrument designed for orbital use. The requirement of the radar system is to generate continuous radar imagery with a 100 kilometer swath with 25 meter resolution from an orbital altitude of 800 kilometers. These requirements impose unique system design problems and a description of the implementation is given. The end-to-end system is described, including interactions of the spacecraft, antenna, sensor, telemetry link, recording subsystem, and data processor. Some of the factors leading to the selection of critical system parameters are listed. The expected error sources leading to degradation of image quality are reported as well as estimate given of the expected performance from data obtained during a ground testing of the completed subsystems.

Jordan, R. L.↗

Environmental performance evaluation of an advanced-design solid-state television camera

The development of an advanced-design black-and-white solid-state television camera which can survive exposure to space environmental conditions was undertaken. A 380 x 488 element buried-channel CCD is utilized as the image sensor to ensure compatibility with 525-line transmission and display equipment. Specific camera design approaches selected for study and analysis included: (1) component and circuit sensitivity to temperature; (2) circuit board thermal and mechanical design; and (3) CCD temperature control. Preferred approaches were determined and integrated into the final design for two deliverable solid-state TV cameras. One of these cameras was subjected to environmental tests to determine stress limits for exposure to vibration, shock, acceleration, and temperature-vacuum conditions. These tests indicate performance at the design goal limits can be achieved for most of the specified conditions.

Source record↗

The Seasat-A synthetic aperture radar design and implementation

The Seasat-A Synthetic Aperture Imaging Radar System is the first imaging radar system intended to be used as a scientific instrument designed for orbital use. The requirement of the radar system is to generate continuous radar imagery with a 100 kilometer swath with 25 meter resolution from an orbital altitude of 800 kilometers. These requirements impose unique system design problems and a description of the implementation will be given. The end-to-end data system will be described, including interactions of the spacecraft, antenna, sensor, telemetry link, recording subsystem, and data processor. Some of the factors leading to the selection of critical system parameters will be listed. The expected error sources leading to degradation of image quality will be described as well as estimates given of the expected performance from data obtained during ground testing of the completed subsystems.

Jordan, R.↗

Mariner Mark II and the exploration of the solar system

NASA's Solar System Exploration Committee has proposed the Mariner Mark II concept for the next generation of deep-space planetary observation missions, which will yield Voyager- and Galileo-quality focused data sets at a fraction of the costs associated with those spacecraft. Cost-limiting strategies under consideration include the use of reconfigurable designs, a multimission ground support system, and the incorporation of such selected new technologies as an all-X band telemetry system, fiber-optic rate sensors for use as an inertial reference system, image compression, and electronic and optical disk data distribution. It is believed possible to meet cost goals of 150-300 million/mission. The missions under consideration are comet rendezvous and sample return, main belt asteroid flybys, and orbits, flybys and probes of Saturn, Titan, Neptune and Uranus.

Neugebauer, M.↗

Space environment effects (M0006)

The effects of long term exposure to the near Earth space environment on advanced electrooptical and radiation sensor components were examined. The effect of long duration spaceflight on the germination rate of selected terrestrial plant seeds is observed in exobiological experiments.

Angelo, J. A., Jr.↗

The Information Adaptive System - A demonstration of real-time onboard image processing

The Information Adaptive System (IAS) program has the objective to develop and demonstrate, at the brassboard level, an architecture which can be used to perform advanced signal procesing functions on board the spacecraft. Particular attention is given to the processing of high-speed multispectral imaging data in real-time, and the development of advanced technology which could be employed for future space applications. An IAS functional description is provided, and questions of radiometric correction are examined. Problems of data packetization are considered along with data selection, a distortion coefficient processor, an adaptive system controller, an image processing demonstration system, a sensor simulator and output data buffer, a test support and demonstration controller, and IAS demonstration operating modes.

Thomas, G. L.↗

Calibration of satellite sensors in the thermal infrared

The addition of a calibration capability in the 8-14 micron thermal infrared region to the current ground-based calibration of orbiting sensors is discussed. Radiance- and reflectance-based methods are compared. An infrared thermometer was selected as the favored instrument for the determination of ground truth. Three methods to determine the effect of sky background on the thermal emittance of the ground are presented, along with use of LOWTRAN 7 to determine atmospheric effects.

Palmer, James M.↗

Overview of the Oregon Transect Ecosystem Research Project

The Oregon Transect Ecosystem Research (OTTER) project is a study of ecosystem functions in coniferous forests using the methods of computer modeling, experimental and theoretical remote sensing, and ecological field and laboratory techniques. The study is focused on predicting the major fluxes of carbon, nitrogen, and water, and the factors that dynamically regulate them. The OTTER project was conceived to test two major questions: (1) Can a generalized ecosystem simulation model, designed to use mainly parameters available from remote sensing, predict the functioning of forests across an environmentally variable region? and (2) To what extent can the variables required by this model be derived from remotely sensed data? The scientific objectives and scope of the project demanded that a coordinated effort be made to link ground measurements with remote sensing and modeling requirements. OTTER was selected as a focus for a National Aeronautics and Space Administration (NASA)-sponsored Multi-sensor Aircraft Campaign (MAC; combining NASA aircraft and sensors with those of others) on the basis of experience gained in past ecosystem studies and remote-sensing projects, and the importance of the OTTER objectives to NASA's long-range science goals and plans. Having several independent approaches available, both on the ground and from various remote-sensing platforms, proved valuable in estimating and validating many of the critical variables. This experience and cross comparison should help simplify future studies of a similar nature. Edited data sets from the OTTER project are now available to the scientific community on optical disks or via on-line data banks at NASA (Washington, D.C., USA) and Oregon State University (Corvallis, Oregon, USA).

Peterson, David L.↗