Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Quantitative x ray phase contrast imaging of oblique shock wave–interface interactions

Oblique shock wave–interface interactions of gases and liquids have been extensively studied in shock tubes using optical methods to measure equation-of-state (EOS) parameters. However, this is difficult with solids due to their opaqueness to visible light. X ray phase contrast imaging (XPCI) has the penetrative strength to probe solids while still being sensitive to mass density and enhancing the visibility of material boundaries. We investigate the accuracy and repeatability of measuring the mean value of the average mass density (areal density divided by thickness) over region S (B S ) and flow deflection angle (θ) from XPCI images of a sample. To that end, a Hough transform-based method for measuring θ is developed. To measure B S , the XPCI image intensity probability density function (PDF) is modeled accounting for the spatial distribution of x ray energy, scintillator response, and pulse-to-pulse variation in the x ray intensity. In addition, a Monte Carlo-based algorithm for computing the B S PDF is developed. Both methods are validated on an impact-generated oblique shock wave interacting at a solid polymer-to-polymer interface. Furthermore this is accomplished through a comparison to hydrodynamic simulations using well-established EOS. Under the modeling framework for the XPCI image intensity, B S is computed with an accuracy of < 0.1% and precision of 3%–5%, while θ has an uncertainty of 0.2°, respectively. This shows that the XPCI-based model that is developed here could be an invaluable tool for high-fidelity testing of hydrodynamic models in shock polar configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Using real-time nuclear activation detectors for measuring neutron yields from D(D, T)n reactions on the national ignition facility (NIF)

The National Ignition Facility (NIF) has 48 Real-Time Nuclear Activation Detectors distributed around the target chamber capable of measuring deuterium-triton reaction neutron yields with high precision. Here, in this work, we extend this functionality to deuterium–deuterium (DD) reaction neutrons using a nuclear reaction that occurs in the detector’s scintillator material. The corresponding decay of the activated material has a very short half-life of 5 s, which necessitates rapid data collection immediately following an experiment. In this regime, dead time can be very high (>50%) adding significant uncertainty to the measurement. To combat this, we have developed a dead time model that can self-consistently describe the measured data. Initial results show reasonable agreement (within 20%) with DD neutron yields from neutron time-of-flight spectrometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

Welch Method and Bootstrapping Applied to Subcritical Gamma Noise

We measured the prompt neutron decay constant 𝛼 of the CROCUS zero-power reactor at the Swiss Federal Institute of Technology Lausanne using cross-power spectral density (CPSD) analysis of gamma-gamma correlations from two trans-stilbene organic scintillators positioned near the reactor core. We measured critical and subcritical states, with water levels ranging from 960 mm (critical) to 800 mm (𝜌=−1.4 $ subcritical). Our analysis used the Welch method, dividing signal segments for fast Fourier transform (FFT) frequency analysis and applying bootstrapping uncertainty quantification that uses Welch-defined segments. Results demonstrated a clear increase in the measured 𝛼 as reactor reactivity decreased, distinguishing critical from subcritical conditions. At the 960-mm critical level, 𝛼 was estimated at 155.9 ± 0.7 s −1 , and for the 800-mm subcritical level, 𝛼 increased significantly to 367.3 ± 6.9 s –1 . A linear regression of subcritical states yielded a critical estimate of 154.0 ± 3.1 s –1 , aligning with the static 𝛼 estimate at critical. The bootstrapping method produced normally distributed 𝛼 estimates, confirming data consistency. The gamma CPSD 𝛼 estimates clearly distinguish reactor states and improve monitoring of zero-power reactors. The future deployment of modular and microreactors as potential candidates for noise analysis is demonstrated in CROCUS, particularly zero-power mock-ups of new designs. The improvement of noise analysis in the subcritical domain from this work will support experimental data for reactor deployment and procedure.

CROCUS↗

A Thin Alumina Film as a Tritium Adsorption Inhibitor for Stainless Steel 316

The effect of a thin alumina coating on stainless-steel 316 (SS316) samples on tritium adsorption and transport are discussed. Compact films of alumina were produced on the surfaces of pristine SS316 samples using an atomic layer deposition (ALD) technique. Subsequently, these samples were exposed for 24 hours to a deuterium-tritium gas mixture (P T =0.5 atm, 25°C). A combination of methods including selective-etching and programmed thermal desorption were employed to assess both, the depth profile of the tritium concentration in the sample and the total quantity of tritium absorbed respectively. Tritium was quantitatively determined through the measurement of beta radioactivity using liquid-scintillation counting techniques. Data suggest that SS316 with a thin film of alumina reduces the total tritium uptake by ~25% relative to uncoated samples. Significantly, such films appear to reduce, by a factor of 200, tritium diffusion into SS316 and therefore constitute an effective barrier against tritium transport. This observation is of practical importance for tritium and, generally, reactive gas handling.

36 MATERIALS SCIENCE↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of flexible proton beam imaging energy spectrometers (PROBIES)

A simple repeating step-filtered structure has been designed and deployed for the detection of MeV-energy proton beams produced from high-intensity short-pulse laser-driven experiments. Due to the diagnostic's ability to recover energy-resolved images of proton beams, it is called the proton beam imager and energy spectrometer (or PROBIES). The flexible design has two useful applications. First, it can be fielded in a configuration with a scintillator and imaging setup in order to collect proton beam information in high-repetition rate experiments. Here we show a configuration that collects the equivalent of a nine-film radiochromic film (RCF) stack, and a technique for using a neural network (NN) to rapidly analyze the images on millisecond time-scales. Second, when using RCF stacks as the detector, the energy resolution capability is greatly increased compared to traditional RCF stacks, while simultaneously reducing the total number of films required to make each measurement. We demonstrate a configuration that provides up to 90 spatially- and energy-resolved datapoints using just ten films. Both designs presented here can be easily customized for anticipated experimental outputs and manufactured at low cost. Such designs allow for rapid prototyping using modern high-accuracy 3D printers or on-demand computer numerical control machining to reduce the reliance on time-consuming film media, analysis, or bulky electro-magnetically dispersing spectrometers. The analysis of data is discussed and a methodology for constructing a NN that is capable of rapidly analyzing data on-the-fly with greater than 95% accuracy is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical characterization of deep-level defects in n-type Al x In y Ga 1- x - y P for the development of solid-state photomultiplier analogs

Characterizing intrinsic defects is an essential step in evaluating materials for novel optoelectronic device applications. For photomultipliers, suppressing dark currents is critical, but a tradeoff is present between maximizing the band gap while remaining sensitive to the wavelength of interest and minimizing the incorporation of fresh defects by growing not-yet-optimized alloys. We present a series of capacitance-based measurements, including deep-level optical spectroscopy, steady-state photocapacitance, and illuminated capacitance-voltage, on photodiodes with lightly n-type Al x In y Ga 1−x−y P absorber regions. Several deep levels are identified, including one near the midgap. Although the inclusion of aluminum increases each trap density by approximately 10×, the hole capture cross-section also appears to decrease, suggesting that Shockley–Read–Hall dark currents may be suppressed. These materials may be good candidates for the development into silicon photomultiplier analogs with a wider bandgap for scintillator applications.

III–V↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Supernova neutrino detection in NOvA

The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Fermilab NuMI beam. These detectors are also sensitive to the flux of neutrinos which are emitted during a core-collapse supernova through inverse beta decay interactions on carbon at energies of &calO;(10 MeV). This signature provides a means to study the dominant mode of energy release for a core-collapse supernova occurring in our galaxy. We describe the data-driven software trigger system developed and employed by the NOvA experiment to identify and record neutrino data from nearby galactic supernovae. This technique has been used by NOvA to self-trigger on potential core-collapse supernovae in our galaxy, with an estimated sensitivity reaching out to 10 kpc distance while achieving a detection efficiency of 23% to 49% for supernovae from progenitor stars with masses of 9.6 M⊙ to 27 M⊙, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for a diffuse flux of photons with energies above tens of PeV at the Pierre Auger Observatory

Diffuse photons of energy above 0.1 PeV, produced through the interactions between cosmic rays and either interstellar matter or background radiation fields, are powerful tracers of the distribution of cosmic rays in the Galaxy. Furthermore, the measurement of a diffuse photon flux would be an important probe to test models of super-heavy dark matter decaying into gamma-rays. In this work, we search for a diffuse photon flux in the energy range between 50 PeV and 200 PeV using data from the Pierre Auger Observatory. For the first time, we combine the air-shower measurements from a 2 km 2 surface array consisting of 19 water-Cherenkov surface detectors, spaced at 433 m, with the muon measurements from an array of buried scintillators placed in the same area. Using 15 months of data, collected while the array was still under construction, we derive upper limits to the integral photon flux ranging from 13.3 to 13.8 km -2 sr -1 yr -1 above tens of PeV. We extend the Pierre Auger Observatory photon search program towards lower energies, covering more than three decades of cosmic-ray energy. This work lays the foundation for future diffuse photon searches: with the data from the next 10 years of operation of the Observatory, this limit is expected to improve by a factor of ∼20.

cosmic rays detectors↗

Validation of the imaging neutral particle analyzer in nearly MHD quiescent plasmas using injected beam ions on DIII-D

The imaging neutral particle analyzer (INPA) is a scintillator-based diagnostic that provides energy and radially resolved measurements of confined fast ions. To verify operation, understanding, and modeling of the diagnostic performance, distributions of deuterium beam ions in low density, nearly MHD-quiescent plasmas are measured on the DIII-D tokamak using the INPA. Here, the distribution is altered by changing the pitch-angle scattering rate with electron cyclotron heating (ECH). Experimental images are mostly reproduced with simulation of core fast ions charge exchanging with injected beam and edge cold neutrals in classical cases. Image comparisons between the experiment and simulation show agreement with less than 25% discrepancies near the beam injection energy of 50 keV. Other strong passive signals, observed in a localized region on the image, are suggested to come from charge exchange between cold neutrals and fast ions around the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of beam-ion losses induced by magnetic perturbations using the light ion beam probe technique in the ASDEX Upgrade tokamak

The impact of externally applied magnetic perturbations (MPs) on fast-ion losses has been investigated by means of the light ion beam probe (LIBP) technique in the ASDEX Upgrade tokamak. The LIBP technique allows to experimentally infer the fast-ion orbit displacement induced by MPs via first-orbit losses using scintillator based fast-ion loss detector (FILD) measurements. The fast-ion orbit displacement against different applied MP spectra has been studied. These shots were conducted in ELM mitigated H-mode plasmas. A rigid rotation of the MP coils was applied with a frequency of 1 Hz, with an n = 2 configuration and changing the differential phase between the upper and lower set of coils (ΔΦ ul ) on a shot-to-shot basis. Beam sources Q7 (tangential) and Q8 (radial) were used to probe different fast-ion orbits with FILD1. The measured fast-ion orbit displacement ranges from 3 to 20 mm approximately, and no qualitative difference is observed between ions from beam sources Q7 and Q8. The minimum is found for a ΔΦ ul ~ 50°, which is shifted with respect to the minimum of the plasma boundary displacement, found at ΔΦ ul ~ 0°. A first attempt to validate the orbit following code ASCOT—including the plasma response calculated with the MARS-F code—against these experimental measurements is performed. Finally, while the dependence of the first-orbit fast-ion displacement with ΔΦ ul does not match the experimental measurements, these simulations do capture other features such as the order of magnitude of the orbit displacement and the importance of the toroidal spectrum of the applied perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗