Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resistive heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Treatment increases stress-corrosion resistance of aluminum alloys

Overaging during heat treatment of the aluminum alloys immediately followed by moderate plastic deformation, preferably by shock loading achieves near optimum values of both yield strength and resistance to stress corrosion. Similar results may be obtained by substituting a conventional deformation process for the shock loading step.

Jacobs, A. J.↗

Heat transfer/storage fluids and systems that utilize such fluids

Heat transfer/storage fluids that are resistant to oxidation in air at elevated temperatures, and systems that utilize such heat transfer/storage fluids, for example, as part of a concentrating solar power (CSP) system or other electricity-generating systems. The heat transfer/storage fluid is a molten chloride solution comprising two or more chlorides selected from the group consisting of CaCl 2 , SrCl 2 , BaCl 2 , NaCl, and KCl.

Sandhage, Kenneth Henry↗

Thermal Vacuum Testing of a Novel Loop Heat Pipe Design for the Swift BAT Instrument

An advanced thermal control system for the Burst Alert Telescope on the Swift satellite has been designed and an engineering test unit (ETU) has been built and tested in a thermal vacuum chamber. The ETU assembly consists of a propylene loop heat pipe, two constant conductance heat pipes, a variable conductance heat pipe (VCHP), which is used for rough temperature control of the system, and a radiator. The entire assembly was tested in a thermal vacuum chamber at NASA/GSFC in early 2002. Tests were performed with thermal mass to represent the instrument and with electrical resistance heaters providing the heat to be transferred. Start-up and heat transfer of over 300 W was demonstrated with both steady and variable condenser sink temperatures. Radiator sink temperatures ranged from a high of approximately 273 K, to a low of approximately 83 K, and the system was held at a constant operating temperature of 278 K throughout most of the testing. A novel LHP temperature control methodology using both temperature-controlled electrical resistance heaters and a small VCHP was demonstrated. This paper describes the system and the tests performed and includes a discussion of the test results.

Ottenstein, Laura↗

Durable and Low-Cost Fractal Structured Multifunctional Coatings for Next-Generation CSP

Fractal coatings on various low-cost and high-temperature metallic substrates such as SS316, SS347, In800H, In740H, In625, Haynes 230, etc. were fabricated employing our patented novel electrodeposition process at various deposition potentials and deposition times, as well as chemical etching. The best combination of the materials and processing conditions were co-optimized for the reliable and repeatable fabrication of the multifunctional coatings. Surface morphologies were examined using SEM and AFM, and fractal characterization was done using a 3D optical surface profiler. Fractal dimension was used to identify successful fabrication and material parameters. The mechanical durability of the coatings was evaluated using several standardized tests, such as sand abrasion (ASTM D968) and adhesion (ASTM D3359), to fully characterize and demonstrate the mechanical durability of the fabricated surfaces. HTF immersion tests on the fractal multifunctional coatings were conducted based on a modification of the ASTM D870, which is established for static water immersion testing. To calculate the corrosion rates and descaled weight loss of the samples subjected to thermal exposure for different time durations (100 h, 300 h, 500 h, and optionally 750 h) to estimate the corrosion rate. While protecting the substrates from corrosion is an important goal, an allied goals is also to examine the post-corrosion temperature stability and properties of the molten salts themselves due to the dissolution of the constituents of the alloys and the corrosion products from the coatings that cause “fouling” of the molten salts. Fouling characteristics of the different molten salt HTFs exposed to coated and uncoated substrates were investigated. Finally, considering a prototype molten salt/sCO2 heat exchanger, cost/performance model is developed to demonstrate that the coatings on low-cost alloys such as stainless steel provide lower levelized cost of heat exchanger compared to high nickel content Ha230.

14 SOLAR ENERGY↗

Heating of the solar middle chromosphere by large-scale electric currents

A global resistive, two-dimensional, time-dependent magnetohydrodynamic (MHD) model is used to introduce and support the hypothesis that the quiet solar middle chromosphere is heated by resistive dissipation of large-scale electric currents which fill most of its volume. The scale height and maximum magnitude of the current density are 400 km and 31.3 m/sq m, respectively. The associated magnetic field is almost horizontal, has the same scale height as the current density, and has a maximum magnitude of 153 G. The current is carried by electrons flowing across magnetic field lines at 1 m/s. The resistivity is the electron contribution to the Pedersen resitivity for a weakly ionized, strongly magnetized, hydrogen gas. The model does not include a driving mechanism. Most of the physical quantities in the model decrease exponentially with time on a resistive timescale of 41.3 minutes. However, the initial values and spatial; dependence of these quantities are expected to be essentially the same as they would be if the correct driving mechanism were included in a more general model. The heating rate per unit mass is found to be 4.5 x 10(exp 9) ergs/g/s, independent of height and latitude. The electron density scale height is found to be 800 km. The model predicts that 90% of the thermal energy required to heat the middle chromosphere is deposited in the height range 300-760 km above the temperature minimum. It is shown to be consistent to assume that the radiation rate per unit volume is proportional to the magnetic energy density, and then it follows that the heating rate per unit volume is also proportional to the energy from the photosphere into the overlying chromosphere are briefly discussed as possible driving mechanisms for establishing and maintaining the current system. The case in which part of or all of the current is carried by protons and metal ions, and the contribution of electron-proton scattering to the current are also considered, with the conclusion that these effects do not change the qualitative prediction of the model, but probably change the quantitative predictions slightly, mainly by increasing the maximum magntiude of the current density and magnetic field to at most approximately 100 mA/m and approximately 484 G, respectively. The heating rate per unit mass, current density scale height, magnetic field scale height, temperatures, and pressures are unchanged or are only slightly changed by including these additional effects due to protons and ions.

Goodman, M. L.↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗

Mechanisms of paint bake response in resistance spot-welded first and third generation AHSS

Implementation of 3rd generation advanced high strength steels (3GAHSS) in automotive structures requires careful consideration of joining process implications. Due to the presence of increased carbon equivalent in 3GAHSS such as 980 HF relative to commonly-applied 1st generation AHSS such as 980 DP, the resultant properties of the weld nugget and heat affected zones in resistance spot welded must be engineered to provide consistent and acceptable performance, specifically in cross-tension loading mode. Although the as-welded cross-tension strength (CTS) of 980 HF is less than 980 DP, there is a significant improvement of the CTS after paint baking in 980 HF welds. 980 DP steel welds do not exhibit such marked improvement upon baking. The mechanism of the strong and beneficial effect of paint baking on 980 HF in comparison to 980 DP is discussed in light of its effect on residual stress distributions and microstructures. Although residual stress (strain) reduction is observed via synchrotron x-ray diffraction for all tested steels, this effect is demonstrated as secondary to the performance restoration of the weld joint in cross tension. High-resolution electron channeling contrast imaging (ECCI) micrographs reveal that paint baking affects a more beneficial degree of martensite tempering in 980 HF as compared to 980 DP. The martensite tempering is also evidenced by both a reduction in nano-hardness of critical microstructural features and re-emergence of ductile fracture behavior following the paint baking process. The tempering of martensite is concluded to be the dominant mechanism in improving cross tension strength of 3GAHSS welds following paint baking.

36 MATERIALS SCIENCE↗

Large magnetoresistance and first-order phase transition in antiferromagnetic single-crystalline EuAg 4 Sb 2

Here, we present the results of a thorough investigation of the physical properties of EuAg 4 Sb 2 single crystals using magnetization, heat capacity, and electrical resistivity measurements. High-quality single crystals, which crystallize in a trigonal structure with space group 𝑅⁢$\bar{3}$𝑚, were grown using a conventional flux method. Temperature-dependent magnetization measurements along different crystallographic orientations confirm two antiferromagnetic phase transitions around 𝑇 𝑁⁢1 = 10.5K and 𝑇 𝑁⁢2 = 7.5K. Isothermal magnetization data exhibit several metamagnetic transitions below these transition temperatures. Antiferromagnetic phase transitions in EuAg 4 Sb 2 are further confirmed by two sharp peaks in the temperature-dependent heat capacity data at 𝑇 𝑁⁢1 and 𝑇 𝑁⁢2 , which shift to lower temperature in the presence of an external magnetic field. Our systematic heat capacity measurements utilizing a long-pulse and single-slope analysis technique allow us to detect a first-order phase transition in EuAg 4 Sb 2 at 7.5 K. The temperature-dependent electrical resistivity data also manifest two features associated with magnetic order. The magnetoresistance exhibits a broad hump due to a field-induced metamagnetic transition. Remarkably, the magnetoresistance keeps increasing without showing any tendency to saturate as the applied magnetic field increases, and it reaches ∼20 000% at 1.6 K and 60 T. At high magnetic fields, several magnetic quantum oscillations are observed, indicating a complex Fermi surface. A large negative magnetoresistance of about −55% is also observed near 𝑇 𝑁⁢1 . Moreover, the 𝐻−𝑇 phase diagram constructed using magnetization, heat capacity, and magnetotransport data indicates complex magnetic behavior in EuAg 4 Sb 2 .

36 MATERIALS SCIENCE↗

Structured large-pore foams improve thermal performance of LiMIT-style liquid lithium PFC

As magnetically confined fusion devices improve, the conditions at the walls become increasingly intense. Plasma facing components (PFCs) must withstand these extreme heat and particle loads without damage or degradation. Liquid lithium PFCs are known to be quite resilient, and the presence of lithium also serves to improve plasma properties. The liquid metal infused trench (LiMIT) concept is an open surface liquid lithium PFC design that has been tested extensively at the University of Illinois and in fusion devices around the world. LiMIT utilizes thermoelectric magnetohydrodynamics (TEMHD) to passively drive liquid lithium flow. This work demonstrates an extension of the LiMIT trench geometry to three dimensions. Additively manufactured large pore metallic foams maintain TEMHD drive while drastically improving heat flux handling and resistance to lithium dryout, a phenomenon where locally high TEMHD forces depresses the lithium level and exposes underlying solid structure. COMSOL multiphysics modeling of the system yields insight into the forces at play in dryout development, and shows the 3D structures can eliminate dryout. Here, low heat proof-of-concept experimental testing of the system matches computational results, and high heat flux electron beam tests more than double the proven operational range of a LiMIT-style PFC, to 6.8 MW m –2 , with no indications of dryout or impending damage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of laser-generated magnetic fields using long laser pulses

In this work, we report on the experimental investigation of magnetic field generation with a half-loop gold sheet coil driven by long-duration (10 ns) and high-power (0.5 TW) laser pulses. The amplitude of the magnetic field was characterized experimentally using proton deflectometry. The field rises rapidly in the first 1 ns of laser irradiation, and then increases slowly and continuously up to 10 ns during further laser irradiation. The transient dynamics of current shape were investigated with a two-dimensional (2D) numerical simulation that included Ohmic heating of the coil and the resultant change of electrical resistivity determined by the coil material temperature. The numerical simulations show rapid heating at the coil edges by current initially localized at the edges. This current density then diffuses to the central part of the sheet coil in a way that depends both on normal current diffusion as well as temporal changes of the coil resistance induced by the Ohmic heating. The measured temporal evolution of the magnetic field is compared with a model that determines a solution to the coil current and voltage that is consistent with a plasma diode model of the drive region and a 2D simulation of current diffusion and dynamic resistance due to Ohmic heating in the laser coil.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of Nucleation and Growth, Specific Heat and Viscosity of Undercooled Melts of Quasicrystals and Polytetrehedral-Phase-Forming Alloys

By investigating the properties of quasicrystals and quasicrystal-forming liquid alloys, we may determine the role of ordering of the liquid phase in the formation of quasicrystals, leading to a better fundamental understanding of both the quasicrystal and the liquid. A quasicrystal is solid characterized by a symmetric but non-periodic arrangement of atoms, usually in the form of an icosahedron (12 atoms, 20 triangular faces). It is theorized that the short-range order in liquids takes this same form. The degree of ordering depends on the temperature of the liquid, and affects many of the liquid s properties, including specific heat, viscosity, and electrical resistivity. The MSFC role in this project includes solidification studies, phase diagram determination, and thermophysical property measurements on the liquid quasicrystal-forming alloys, all by electrostatic levitation (ESL). The viscosity of liquid quasicrystal-forming alloys is measured by the oscillating drop method, both in the stable and undercooled liquid state. The specific heat of solid, undercooled liquid, and stable liquid are measured by the radiative cooling rate of the droplets.

Source record↗

Measurement of interfacial thermal resistance in high-energy-density matter

Heat transport across interfaces is a ubiquitous phenomenon with many unresolved aspects. In particular, it is unknown if an interfacial thermal resistance (ITR) occurs in matter with high-energy-density where free electrons dominate the heat conduction. Here, we report on the first experimental evidence that a significant heat barrier is present between two different regions of high-energy-density matter: a strongly heated tungsten wire and a surrounding plastic layer that stays relatively cold. We use diffraction-enhanced imaging to track the time evolution of density discontinuities and reconstruct the temperature evolution in the quasi-stationary stage. The clear signatures of a temperature jump demonstrate the importance of the ITR for strongly heated systems with far-reaching implications for interpreting experiments and applications like inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel textured surfaces for superior corrosion mitigation in molten carbonate salts for concentrating solar power

Corrosion of metals in contact with molten salts used for thermal energy storage and heat transport at high temperatures is a serious impediment to the development of next-generation concentrating solar thermal systems. Toward addressing this limitation, novel multiscale fractal-textured Ni coatings on a variety of substrate alloys are presented in this study for exceptional corrosion mitigation in molten carbonate salts at a high temperature. Strongly adherent, durable, single-layer, and double-layer multiscale fractal coatings were fabricated using the electrodeposition method. Corrosion performance of the coatings on SS310, SS316, SS347, and In800H was studied in molten carbonate salt (32% Li 2 CO 3 +33% Na 2 CO 3 +35% K 2 CO 3 ) at 750 °C. Single-layer coatings are stable up to 300 h immersion, whereas double-layer coatings are stable beyond 750 h. The corrosion rate of double-layer Ni coatings on ferrous alloys was reduced by as much as 60% from that of uncoated surfaces and was about 18% below that of higher cost, high Ni content Ha230. The study represents the first-ever report of corrosion characteristics of alloys in carbonate salts at 750 °C and the first demonstration of a means of dramatically reducing corrosion in carbonate salts at a high temperature. The article is significant in that it provides a viable approach for low-cost structural alloys to be corrosion-resistant to molten carbonate heat transfer fluids and storage media in high-temperature concentrating solar thermal applications. Furthermore, the corrosion-resistant coatings provide opportunities for the use of low-cost, ferritic alloys instead of the expensive nickel-based alloys in practice.

14 SOLAR ENERGY↗

Joule heating and runaway electron acceleration in a solar flare

The hard and soft x ray and microwave emissions from a solar flare (May 14, 1980) were analyzed and interpreted in terms of Joule heating and runaway electron acceleration in one or more current sheets. It is found that all three emissions can be generated with sub-Dreicer electric fields. The soft x ray emitting plasma can only be heated by a single current sheet if the resistivity in the sheet is well above the classical, collisional resistivity of 10(exp 7) K, 10(exp 11)/cu cm plasma. If the hard x ray emission is from thermal electrons, anomalous resistivity or densities exceeding 3 x 10(exp 12)/cu cm are required. If the hard x ray emission is from nonthermal electrons, the emissions can be produced with classical resistivity in the current sheets if the heating rate is approximately 4 times greater than that deduced from the soft x ray data (with a density of 10(exp 10)/cu cm in the soft x ray emitting region), if there are at least 10(exp 4) current sheets, and if the plasma properties in the sheets are characteristic of the superhot plasma observed in some flares by Lin et al., and with Hinotori. Most of the released energy goes directly into bulk heating, rather than accelerated particles.

Holman, Gordon D.↗

The fatigue response of the aluminium-lithium alloy, 8090

The fatigue response of an Al-Li-Cu-Mg-Zr (8090) alloy has been studied at room temperature. The initiation and growth of small and long cracks has been examined at R = 0.1 and at a frequency of 100 Hz. Initiation was observed to occur dominantly at sub-grain boundaries. The growth of the small cracks was crystallographic in character and exhibited little evidence of retardation or arrest at the grain boundaries. The long crack data showed the alloy to have a high resistance to fatigue crack growth with underaging providing the optimum heat treatment for fatigue crack growth resistance. In general, this can be attributed to high levels of crack closure which resulted from the presence of extensive microstructurally related asperities.

Birt, M. J.↗

Heat flux microsensor measurements

A thin-film heat flux sensor has been fabricated on a stainless steel substrate. The thermocouple elements of the heat flux sensor were nickel and nichrome, and the temperature resistance sensor was platinum. The completed heat flux microsensor was calibrated at the AEDC radiation facility. The gage output was linear with heat flux with no apparent temperature effect on sensitivity. The gage was used for heat flux measurements at the NASA Langley Vitiated Air Test Facility. Vitiated air was expanded to Mach 3.0 and hydrogen fuel was injected. Measurements were made on the wall of a diverging duct downstream of the injector during all stages of the hydrogen combustion tests. Because the wall and the gage were not actively cooled, the wall temperature reached over 1000 C (1900 F) during the most severe test.

Terrell, J. P.↗

Ferroelectric Stirling-Cycle Refrigerator

A Stirling-cycle refrigerator has a three-pump configuration and pumping sequence, in which one pump serves as a compressor. one pump serves as an expander, and one pump serves as a displacer. The pumps are ferroelectrically actuated diaphragm pumps which are coordinated by synchronizing the ferroelectric-actuator voltages in such a way that the net effect of the displacer is to reduce the deleterious effect of dead space; that is, to circulate a greater fraction of the working fluid through the heat exchangers than would be possible by use of the compressor and expander alone. In addition. the displacer can be controlled separately to make the flow of working fluid in the heat exchangers turbulent (to increase the rate of transfer of heat at the cost of greater resistance to flow) or laminar (to decrease the resistance to flow at the cost of a lower heat-transfer rate).

Jalink, Antony, Jr.↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗