Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “regression testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

SU-D-204-01: A Methodology Based On Machine Learning and Quantum Clustering to Predict Lung SBRT Dosimetric Endpoints From Patient Specific Anatomic Features

Purpose: To develop a data-mining methodology based on quantum clustering and machine learning to predict expected dosimetric endpoints for lung SBRT applications based on patient-specific anatomic features. Methods: Ninety-three patients who received lung SBRT at our clinic from 2011–2013 were retrospectively identified. Planning information was acquired for each patient, from which various features were extracted using in-house semi-automatic software. Anatomic features included tumor-to-OAR distances, tumor location, total-lung-volume, GTV and ITV. Dosimetric endpoints were adopted from RTOG-0195 recommendations, and consisted of various OAR-specific partial-volume doses and maximum point-doses. First, PCA analysis and unsupervised quantum-clustering was used to explore the feature-space to identify potentially strong classifiers. Secondly, a multi-class logistic regression algorithm was developed and trained to predict dose-volume endpoints based on patient-specific anatomic features. Classes were defined by discretizing the dose-volume data, and the feature-space was zero-mean normalized. Fitting parameters were determined by minimizing a regularized cost function, and optimization was performed via gradient descent. As a pilot study, the model was tested on two esophageal dosimetric planning endpoints (maximum point-dose, dose-to-5cc), and its generalizability was evaluated with leave-one-out cross-validation. Results: Quantum-Clustering demonstrated a strong separation of feature-space at 15Gy across the first-and-second Principle Components of the data when the dosimetric endpoints were retrospectively identified. Maximum point dose prediction to the esophagus demonstrated a cross-validation accuracy of 87%, and the maximum dose to 5cc demonstrated a respective value of 79%. The largest optimized weighting factor was placed on GTV-to-esophagus distance (a factor of 10 greater than the second largest weighting factor), indicating an intuitively strong correlation between this feature and both endpoints. Conclusion: This pilot study shows that it is feasible to predict dose-volume endpoints based on patient-specific anatomic features. The developed methodology can potentially help to identify patients at risk for higher OAR doses, thus improving the efficiency of treatment planning. R01-184173.

60 APPLIED LIFE SCIENCES↗

Adsorption Isotherms for Xenon and Krypton using INL HZ-PAN and AgZ-PAN Sorbents

The generation of adsorption isotherms compliments the scale-up of off-gas processes used to control the emission of encapsulated radioactive volatile fission and activation products released during Used Nuclear Fuel (UNF) reprocessing activities. A series of experiments were conducted to obtain capacity results for varying Kr and Xe gas concentrations using HZ-PAN and AgZ-PAN engineered form sorbents. Gas compositions for Kr ranged from 150-40,000 ppmv and 250-5020 ppmv for Xe in a helium balance. The experiments were all performed at 220 K at a flowrate of 50 sccm. Acquired capacities were then respectively fit to the Langmuir equation using the Langmuir linear regression method to obtain the equilibrium parameters Qmax and Keq. Generated experimental adsorption isotherms were then plotted with the Langmuir predicted isotherms to illustrate agreement between the two. The Langmuir parameters were provided for input into the OSPREY model to predict breakthrough of single component adsorption of Kr and Xe on HZ-PAN and AgZ-PAN sorbents at the experimental conditions tested. Kr and Xe capacities resulting from model breakthrough predictions were then compared to experimental capacities for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning-based inversion for acoustic impedance with large synthetic training data: Workflow and data characterization

Where wells are sparse or training data are difficult to label with high-quality wireline-derived impedance logs, machine learning (ML)-based inversion of acoustic impedance typically depends on small training data sets, leading to biased prediction. We have advanced a novel workflow that applies large synthetic seismic training data to reduce facies-related bias. Using a geologically realistic model as the truth model, we randomly select sparse seed wells to perform sequential Gaussian simulation (SGS) for impedance models of the same geometry and simulate facies variability. We implement random forest regression on 30 features extracted from the synthetic volume. We observe that more seed wells tend to reduce facies-induced bias by sampling more types of facies, resulting in a better prediction. We then focus on the responses of SGS models to facies changes, the number of seed wells necessary for a useful synthetic model, and how much a synthetic model can help ML-based inversion. Here, we observe that the SGS synthetic training model outperforms well-direct training in general. For modeled clastic shore-zone systems in Miocene Gulf of Mexico, two or more seed wells are necessary for a significant reduction of root-mean-square error and outliners, and improvement of facies imaging. In a field-data test, we apply a similar workflow to quantitatively predict acoustic impedance, which is then converted to a sand-volume map at a high-frequency sequence (10–100 m), revealing detailed facies and sandstone patterns. Such results are valuable in many geologic and engineering applications, such as hydrocarbon and CO 2 reservoir prospecting, reserve estimation, simulation, etc.

3D seismic↗

Surgical Resection of Brain Metastases and the Risk of Leptomeningeal Recurrence in Patients Treated With Stereotactic Radiosurgery

Purpose: Recent prospective data have shown that patients with solitary or oligometastatic disease to the brain may be treated with upfront stereotactic radiosurgery (SRS) with deferral of whole-brain radiation therapy (WBRT). This has been extrapolated to the treatment of patients with resected lesions. The aim of this study was to assess the risk of leptomeningeal disease (LMD) in patients treated with SRS to the postsurgical resection cavity for brain metastases compared with patients treated with SRS to intact metastases. Methods and Materials: Four hundred sixty-five patients treated with SRS without upfront WBRT at a single institution were identified; 330 of these with at least 3 months' follow-up were included in this analysis. One hundred twelve patients had undergone surgical resection of at least 1 lesion before SRS compared with 218 treated for intact metastases. Time to LMD and overall survival (OS) time were estimated from date of radiosurgery, and LMD was analyzed by the use of cumulative incidence method with death as a competing risk. Univariate and multivariate analyses were performed with competing risk regression to determine whether various clinical factors predicted for LMD. Results: With a median follow-up time of 9.0 months, 39 patients (12%) experienced LMD at a median of 6.0 months after SRS. At 1 year, the cumulative incidence of LMD, with death as a competing risk, was 5.2% for the patients without surgical resection versus 16.9% for those treated with surgery (Gray test, P<.01). On multivariate analysis, prior surgical resection (P<.01) and breast cancer primary (P=.03) were significant predictors of LMD development. The median OS times for patients undergoing surgery compared with SRS alone were 12.9 and 10.6 months, respectively (log-rank P=.06). Conclusions: In patients undergoing SRS with deferral of upfront WBRT for intracranial metastatic disease, prior surgical resection and breast cancer primary are associated with an increased risk for the development of LMD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decentralized Voltage Control of Large-Scale Distribution System with PVs Based on MADRL

This paper proposes a model-free decentralized control framework for the voltage regulation of large-scale distribution systems through the coordinated control of PV inverters. This is achieved by developing a novel interaction mechanism between the surrogate model and the centralized training and decentralized execution multiagent deep reinforcement learning framework. Specifically, the sparse Gaussian processes regression method is first utilized to develop the surrogate model of the original distribution system for reward calculation during the training stage, where each agent represents a sub-region in the centralized fashion for coordination strategy learning. After that, the learned control rules are used to inform controllers within each sub-region for real-time decisions with only local measurements. Comparative tests among various methods on the EPRI Ckt5 test system demonstrate the effectiveness of the proposed method.

distribution system↗

Using ancillary information to improve hypocenter estimation: Bayesian single event location (BSEL)

We have developed and tested an algorithm, Bayesian Single Event Location (BSEL), for estimating the location of a seismic event. The main driver for our research is the inadequate representation of ancillary information in the hypocenter estimation procedure. The added benefit is that we have also addressed instability issues often encountered with historical NLR solvers (e.g., non-convergence or seismically infeasible results). BSEL differs from established nonlinear regression techniques by using a Bayesian prior probability density function (prior PDF) to incorporate ancillary physical basis constraints about event location. P-wave arrival times from seismic events are used in the development. Depth, a focus of this paper, may be modeled with a prior PDF (potentially skewed) that captures physical basis bounds from surface wave observations. This PDF is constructed from a Rayleigh wave depth excitation eigenfunction that is based on the observed minimum period from a spectrogram analysis and estimated near-source elastic parameters. For example, if the surface wave is an Rg phase, it potentially provides a strong constraint for depth, which has important implications for remote monitoring of nuclear explosions. The proposed Bayesian algorithm is illustrated with events that demonstrate its congruity with established hypocenter estimation methods and its application potential. The BSEL method is applied to three events: (1) A shallow Mw 4 earthquake that occurred near Bardwell, KY on June 6, 2003, (2) the Mw 5.6 earthquake of July 26, 2005 that occurred near Dillon, MT, and (3) a deep Mw 5.7 earthquake that occurred off the coast of Japan on April 22, 1980. A strong Rg was observed from the Bardwell, KY earthquake that places very strong constraints on depth and origin time. No Rg was observed for the Dillon, MT earthquake, but we used the minimum observed period of a Rayleigh wave (7 seconds) to reduce the depth and origin time uncertainty. Because the Japan event was deep, there is no observed surface wave energy. We utilize the prior generated from the Dillon, MT event to show that even in the case when a prior is inappropriately applied, high quality data will overcome its influence and result in a reasonable hypocenter estimate.

58 GEOSCIENCES↗

Impact of a Health Information Technology Intervention on the Follow-up Management of Pulmonary Nodules

Lung cancer is the leading cause of cancer deaths in the USA. The most common abnormalities suspicious for lung cancer on CT scan include pulmonary nodules. Recommendations to improve care for patients with pulmonary nodules require follow-up management. However, transitions in care, especially for patients undergoing transitions to ambulatory care sites from the emergency department (ED) and inpatient settings, can exacerbate failures in follow-up testing and compromise patient safety. We evaluate the impact of a discharge module that includes follow-up recommendations for further management of pulmonary nodules on the study outcome and follow-up management of patients with pulmonary nodules within 1 year after discharge. After IRB approval, we collected data on all patients undergoing chest or abdominal CT exams over a 12-month baseline and 12-month intervention period at an academic medical center. The inpatient discharge module was implemented in November 2011; the ED module was implemented in May 2012. Multivariable logistic regression was performed to account for care setting, imaging modality, recommendations, and patient demographics. Implementation of a discharge module resulted in improved follow-up of patients with pulmonary nodules within 1 year after discharge (OR = 1.64, p = 0.01); the ED implementation resulted in better follow-up compared to the inpatient module (OR = 2.24, p < 0.01). Twenty-seven percent of patients with pulmonary nodules received follow-up management, which, although significantly improved from the 18% baseline, remains low. An electronic discharge module is associated with improved follow-up management of patients with pulmonary nodules, and may be combined with interventions to further improve management of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of four learning-based methods for predicting groundwater redox status

Knowing the location where groundwater denitrification occurs, or by proxy the groundwater redox status (oxic, mixed, and anoxic), is valuable information for assessing and managing potential agricultural land-use impacts on freshwater quality. We compare the efficacy of supervised (Linear Discriminant Analysis LDA; Boosted Regression Trees, BRT; and Random Forest, RF) and unsupervised (Modified Self-Organizing Map, MSOM) learning-based methods to predict groundwater redox status in the agriculturally dominated Tasman, Waikato, and Wellington regions of New Zealand. Thresholds applied to regional groundwater-quality samples provide redox status variables and learn heuristics constrained by these variables and applied to spatial factors (climate, elevation, geologic, hydrology soils, and well depth) identify optimal sets of regional predictor variables. A split-sample approach is used to train and test the learning methods ability to predict redox status using the optimal predictor variables. Overall, the supervised methods demonstrate a prediction bias toward oxic conditions and inability to perform statistically well when using independent regional data; for example, consider kappa statistics for BRT (Tasman: 0.42, Waikato: 0.38, Wellington: 0.17), RF (Tasman: 0.42, Waikato: 0.47, Wellington: 0.17 and LDA (Tasman: 0.46, Waikato: 0.32, Wellington: 0.17). By contrast, the unsupervised method performs statistically well when predicting oxic, mixed, and anoxic conditions and corresponding depths when using independent regional data; for example, consider MSOM kappa statistics for Tasman: 0.78, Waikato: 0.80, Wellington: 0.76. The unsupervised learning method provides the added benefits of being (1) able to combine predictions into 3D regional anoxic probability plots for interpreting the spatial influence of paleosols and groundwater flowpaths on redox status, and (2) readily extended to map 3D redox status across New Zealand and other countries despite data bias and sparsity.

machine learning algorithms, Random Forest, booste↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Leveraging visible and near-infrared spectroelectrochemistry to calibrate a robust model for Vanadium(IV/V) in varying nitric acid and temperature levels

Spectroelectrochemistry and optimal design of experiments can be used to rapidly build accurate models for species quantification and enable a greater level of process awareness. Optical spectroscopy can provide vital elemental and molecular information, but several hurdles must be overcome before it can become a widely adopted analytical method for remote analysis in the nuclear field. Analytes with varying oxidation state, acid concentration, and fluctuating temperature must be efficiently accounted for to minimize time and resources in restrictive hot cell environments. The classic one-factor-at-a-time approach is not suitable for frequent calibration/maintenance operations in this setting. Therefore, a novel alternative was developed to characterize a system containing vanadium(IV/V) (0.01–0.1 M), nitric acid (0.1–4 M), and varying temperatures (20–45 °C). Here, spectroelectrochemistry methods were used to acquire a sample set selected by optimal design of experiments. This new approach allows for the accurate analysis of vanadium and HNO 3 concentration by leveraging UV–Vis–NIR absorption spectroscopy with robust and accurate chemometric models. The top model's root mean squared error of prediction percent values were 3.47%, 4.06%, 3.40%, and 10.9% for V(IV), V(V), HNO 3 , and temperature, respectively. These models, efficiently developed using the designed approach, exhibited strong predictive accuracy for vanadium and acid with varying oxidation states and temperature using only spectrophotometry, which advances current technology for real-world hot cell applications. Additionally, Nernstian analysis of the V(IV/V) standard potential was performed using traditional absorbance methods and multivariate curve resolution (MCR). The successful tests demonstrated that MCR Nernst tests may be valuable in highly convoluted spectral systems to better understand the redox processes' behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual-energy CT in the obese: a preliminary retrospective review to evaluate quality and feasibility of the single-source dual-detector implementation

Purpose: To determine the feasibility of performing dual-energy CT with a single-source spectral detector system in obese patients. Materials and methods: Retrospective, IRB-approved review of 28 patients weighing ≥ 270 lbs (122 kg) who underwent CT of the abdomen on a single-source spectral detector system was performed. Two blinded, independent radiologists rated relative preference between conventional CT images taken at 120 kVp (CCT120) and monoenergetic 70 keV equivalent (MonoE70) as well as iodine map image quality in the spleen, pancreas, kidneys, and liver. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between conventional CT and MonoE70 images and correlated with body habitus markers of weight, height, and abdominal diameter. Results: MonoE70 images were preferred by radiologists 100% of the time (1-sample t test, p < 0.0001) over conventional CCT120 images. Noise was significantly lower; SNR and CNR were significantly higher in MonoE70 images than in CCT120 images (paired t tests, p < 0.0001). Mean iodine map rating (scale 1–5) was 4.54 ± 0.58, denoting near homogenous and complete iodine mapping through the spleen, pancreas, kidneys, and liver for the majority of patients. Body habitus markers were not significantly correlated with image preference score; noise; MonoE70 SNR; MonoE70 CNR; change in noise, SNR, or CNR from CCT120 to MonoE70, or iodine map quality; ordinal and linear regression, p = 0.2547, p = 0.6837, p = 0.1888, p = 0.5489, p = 0.9830, p = 0.8849, p = 0.8741, p = 0.1522, respectively. Conclusion: The single-source spectral detector implementation of dual-energy CT provides viable, high-quality imaging for obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scattering insights into shear-induced scission of rod-like micelles

Understanding the scission of rod-like micelles under mechanical forces is crucial for optimizing their stability and behavior in industrial applications. This study investigates how micelle length, flexibility, and external forces interact, offering insights into the design of micellar systems in processes influenced by mechanical stress. Although significant, direct experimental observations of flow-induced micellar scission using scattering techniques remain scarce. Small angle neutron scattering (SANS) is used to explore the shear response of aqueous cetyltrimethylammonium bromide (CTAB) solutions with sodium nitrate. Rheological tests show shear thinning with no shear banding, ensuring a uniform flow field for reliable interpretation of scattering data. As shear rate increases, the scattering spectra show angular distortion, which is analyzed using spherical harmonic decomposition to characterize flow-induced scission and micelle orientation under shear. Two analysis steps are used: a model-independent spectral eigendecomposition reveals a decrease in micellar length, while regression analysis quantifies the evolution of the length distribution and mean length with shear rate. Additionally, micelle alignment increases with shear, quantified by the orientational distribution function. In conclusion, these findings provide experimental evidence for flow-induced alignment and scission, offering a new framework for understanding shear-induced phenomena in micellar systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Catalytic Reduction of Esters over Zirconia-Supported Metal Catalysts

Esters are often produced as unwanted byproducts during the catalytic upgrading of ethanol to diesel fuel precursors through Guerbet coupling. Removal of esters from the product stream is important to prevent the loss of downstream catalyst activity from ester-derived carboxylic acids. In this work, we studied ester hydrogenolysis to the parent alcohols as a viable route for enhanced diesel fuel production. Specifically, we investigated the reduction of hexyl acetate in butanol over ZrO 2 -supported Ni, Co, Cu, Rh, Pd, and Pt catalysts, where Cu/ZrO 2 was the most selective catalyst for the hydrogenolysis of hexyl acetate into hexanol and ethanol. Thermodynamic analysis reveals that a 90% alcohol yield can be obtained at 200 °C, 30 bar, and a relatively high H 2 :hexyl acetate molar ratio of 480:1. Experimentally, an alcohol yield of 88% yield was obtained with a 10 wt % Cu/ZrO 2 catalyst at these conditions with a residence time of 5.4 h kg cat kmol gas –1 . Catalytic tests on the support revealed that ZrO 2 catalyzes the transesterification reaction between hexyl acetate and butanol. However, only the Cu sites can catalyze the hydrogenolysis of the esters into the final alcohols. We developed a kinetic model for our experimental results, which shows that the transesterification and hydrogenolysis reactions run at two different timescales, the former being 10 times faster than the latter. Data regression has been used to develop a model to predict the mole fraction distribution of ester hydrogenolysis products over a wide range of contact times. Cu/ZrO 2 loses half its catalytic activity after 80 h of time on stream. Modeling of deactivation data reveals that the ZrO 2 support conserves a residual activity due to external active sites, while active sites over the Cu surface deactivate at different rates. Furthermore, the catalytic conversion of esters into their parent alcohols is relevant to the production of surrogate liquid fuels since alcohols can be bimolecularly dehydrated to produce a blend of ethers with diesel fuel-like properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

What's inside the cone? Numerically reconstructing the metric from observations

We investigate the possibility of using Gaussian process regression to smooth data on the current past null-cone for use as the input to a relativistic integration scheme. The algorithm we present is designed to reconstruct the metric of spacetime within the class of spherically symmetric dust universes, with or without a cosmological constant. Assuming that gravity is well described by General Relativity, we demonstrate how the algorithm can be employed to test the Copernican principle based on currently available observations. It is shown that currently available data is not sufficient for a conclusive result. The intrinsic noise present in realistic data presents a challenge for our smoothing algorithm and we discuss some of its limitations as well as possible extensions to it. We conclude by demonstrating how a direct determination of the cosmological constant is possible using redshift drift data.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-18A-02: Calibration-Free Combined KV/MV Short Scan CBCT

Purpose: To combine orthogonal kilo-voltage (kV) and Mega-voltage (MV) projection data for short scan cone-beam CT to reduce imaging time on current radiation treatment systems, using a calibration-free gain correction method. Methods: Combining two orthogonal projection data sets for kV and MV imaging hardware can reduce the scan angle to as small as 110° (90°+fan) such that the total scan time is ∼18 seconds, or within a breath hold. To obtain an accurate reconstruction, the MV projection data is first linearly corrected using linear regression using the redundant data from the start and end of the sinogram, and then the combined data is reconstructed using the FDK method. To correct for the different changes of attenuation coefficients in kV/MV between soft tissue and bone, the forward projection of the segmented bone and soft tissue from the first reconstruction in the redundant region are added to the linear regression model. The MV data is corrected again using the additional information from the segmented image, and combined with kV for a second FDK reconstruction. We simulated polychromatic 120 kVp (conventional a-Si EPID with CsI) and 2.5 MVp (prototype high-DQE MV detector) projection data with Poisson noise using the XCAT phantom. The gain correction and combined kV/MV short scan reconstructions were tested with head and thorax cases, and simple contrast-to-noise ratio measurements were made in a low-contrast pattern in the head. Results: The FDK reconstruction using the proposed gain correction method can effectively reduce artifacts caused by the differences of attenuation coefficients in the kV/MV data. The CNRs of the short scans for kV, MV, and kV/MV are 5.0, 2.6 and 3.4 respectively. The proposed gain correction method also works with truncated projections. Conclusion: A novel gain correction and reconstruction method was developed to generate short scan CBCT from orthogonal kV/MV projections. This work is supported by NIH Grant 5R01CA138426-05.

60 APPLIED LIFE SCIENCES↗

Short-wavelength-sensitive 2 (Sws2) visual photopigment models combined with atomistic molecular simulations to predict spectral peaks of absorbance

For many species, vision is one of the most important sensory modalities for mediating essential tasks that include navigation, predation and foraging, predator avoidance, and numerous social behaviors. The vertebrate visual process begins when photons of the light interact with rod and cone photoreceptors that are present in the neural retina. Vertebrate visual photopigments are housed within these photoreceptor cells and are sensitive to a wide range of wavelengths that peak within the light spectrum, the latter of which is a function of the type of chromophore used and how it interacts with specific amino acid residues found within the opsin protein sequence. Minor differences in the amino acid sequences of the opsins are known to lead to large differences in the spectral peak of absorbance (i.e. the λ max value). In our prior studies, we developed a new approach that combined homology modeling and molecular dynamics simulations to gather structural information associated with chromophore conformation, then used it to generate statistical models for the accurate prediction of λ max values for photopigments derived from Rh1 and Rh2 amino acid sequences. In the present study, we test our novel approach to predict the λ max of phylogenetically distant Sws2 cone opsins. To build a model that can predict the λ max using our approach presented in our prior studies, we selected a spectrally-diverse set of 11 teleost Sws2 photopigments for which both amino acid sequence information and experimentally measured λ max values are known. The final first-order regression model, consisting of three terms associated with chromophore conformation, was sufficient to predict the λ max of Sws2 photopigments with high accuracy. This study further highlights the breadth of our approach in reliably predicting λ max values of Sws2 cone photopigments, evolutionary-more distant from template bovine RH1, and provided mechanistic insights into the role of known spectral tuning sites.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling dynamics of acute HIV infection incorporating density-dependent cell death and multiplicity of infection

Understanding the dynamics of acute HIV infection can offer valuable insights into the early stages of viral behavior, potentially helping uncover various aspects of HIV pathogenesis. The standard viral dynamics model explains HIV viral dynamics during acute infection reasonably well. However, the model makes simplifying assumptions, neglecting some aspects of HIV infection. For instance, in the standard model, target cells are infected by a single HIV virion. Yet, cellular multiplicity of infection (MOI) may have considerable effects in pathogenesis and viral evolution. Further, when using the standard model, we take constant infected cell death rates, simplifying the dynamic immune responses. Here, we use four models—1) the standard viral dynamics model, 2) an alternate model incorporating cellular MOI, 3) a model assuming density-dependent death rate of infected cells and 4) a model combining (2) and (3)—to investigate acute infection dynamics in 43 people living with HIV very early after HIV exposure. We find that all models qualitatively describe the data, but none of the tested models is by itself the best to capture different kinds of heterogeneity. Instead, different models describe differing features of the dynamics more accurately. For example, while the standard viral dynamics model may be the most parsimonious across study participants by the corrected Akaike Information Criterion (AICc), we find that viral peaks are better explained by a model allowing for cellular MOI, using a linear regression analysis as analyzed by R 2 . These results suggest that heterogeneity in within-host viral dynamics cannot be captured by a single model. Depending on the specific aspect of interest, a corresponding model should be employed.

60 APPLIED LIFE SCIENCES↗

Laboratory investigation and commercial test for rotors-assembled strand applied in smooth tube

In the commercial test for smooth tube inserted with rotors-assembled strand comparing with non-inserted ones on condensers in electric power plant, using water as working fluid, the single-phase pressure drop and heat transfer were measured. It was found difficult to receive reliable and accurate enough data through commercial test. Meanwhile, the single-phase pressure drop and heat transfer in a rotors-assembled strand inserted tube were measured in laboratory, with the tube side Prandtl numbers varying from 5.67 to 5.80 and the tube side Reynolds numbers varying from 21,300 to 72,200. Before that, a validation experiment based on the same smooth tube was carried out to testify the experimental system and the data reduction method, in which fixed mounts were employed to eliminate entrance effects. The Prandtl numbers varied from 5.64 to 5.76 and the Reynolds numbers varied from 19,000 to 56,000 in the tube. The annular side Reynolds numbers remained nearly constant at the value of around 50,000 for all experiments, with the annular side Prandtl numbers varying from 8.02 to 8.22. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers while it hardly affects the Nusselt numbers. On the other hand, experiment for the tube inserted with rotors-assembled strand show remarkable improvement for heat transfer with the Nusselt number increased by 9.764-11.87% and the overall heat transfer coefficient increased by 7.08-7.49% within the range of Reynolds number from about 21,300 to 55,500. Meanwhile, friction factor increases inevitably by 278.1-353.9% within the same range of Reynolds number. Based on through multivariant linear normal regression method, the Reynolds number and Prandtl number dependencies of the Nusselt number and friction factor were determined to be Nu = 0.0031Re{sup 0.9}Pr{sup 1.0849} and f = 0.993Re{sup -0.22}. (author)

42 ENGINEERING↗