Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Seeing the magnetic monopole through the mirror of topological surface states

Existence of the magnetic monopole is compatible with the fundamental laws of nature, however, this illusive particle has yet to be detected experimentally. In this work, we show that an electric charge near the topological surface state induces an image magnetic monopole charge due to the topological magneto-electric effect. The magnetic field generated by the image magnetic monopole can be experimentally measured, and the inverse square law of the field dependence can be determined quantitatively. We propose that this effect can be used to experimentally realize a gas of quantum particles carrying fractional statistics, consisting of the bound states of the electric charge and the image magnetic monopole charge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved speckle projection profilometry for out-of-plane shape measurement

An improved speckle projection profilometry that combines the projection of computer generated random speckle patterns using an ordinary LCD projector and the two-dimensional digital image correlation technique for in-plane displacements measurement is proposed for accurate out-of-plane shape and displacement measurements. The improved technique employs a simple yet effective calibration technique to determine the linear relationship between the out-of-plane height and the measured in-plane displacements. In addition, the iterative spatial domain cross-correlation algorithm, i.e., the improved Newton-Raphson algorithm using the zero-normalized sum of squared differences correlation criterion and the second-order shape function was employed in image correlation analysis for in-plane displacement determination of the projected speckle patterns, which provides more reliable and accurate matching with a higher correlation coefficient. Experimental results of both a regular cylinder and a human hand demonstrate that the proposed technique is easy to implement and can be applied to a practical out-of-plane shape and displacement measurement with high accuracy.

36 MATERIALS SCIENCE↗

A Brightness Amplifier on Manganese Atom Transitions with a Pulse Repetition Frequency of up to 100 kHz

Results of the development and study of an image brightness amplifier on manganese atom transitions for problems of object visualization in active optical systems are presented. The possibility in principle of using the developed active element for visualization of objects and processes in two spectral ranges—visible and near-IR—is shown. Profiles of the active element radiation beam at pulse repetition frequencies of up to 100 kHz have been obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction 3-dimensional image from 2-dimensional image of status optical coherence tomography (OCT) for analysis of changes in retinal thickness

Optical Coherence Tomography is often used in medical image acquisition to diagnose that change due easy to use and low price. Unfortunately, this type of examination produces a two-dimensional retinal image of the point of acquisition. Therefore, this study developed a method that combines and reconstruct 2-dimensional retinal images into three-dimensional images to display volumetric macular accurately. The system is built with three main stages: data acquisition, data extraction and 3-dimensional reconstruction. At data acquisition step, Optical Coherence Tomography produced six *.jpg images of each patient were further extracted with MATLAB 2010a software into six one-dimensional arrays. The six arrays are combined into a 3-dimensional matrix using a kriging interpolation method with SURFER9 resulting 3-dimensional graphics of macula. Finally, system provides three-dimensional color graphs based on the data distribution normal macula. The reconstruction system which has been designed produces three-dimensional images with size of 481 × 481 × h (retinal thickness) pixels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging the inside of thick structures using cosmic rays

The authors present here a new method to image reinforcement elements inside thick structures and the results of a demonstration measurement performed on a mock-up wall built at Los Alamos National Laboratory. The method, referred to as “multiple scattering muon radiography”, relies on the use of cosmic-ray muons as probes. The work described in this article was performed to prove the viability of the technique as a means to image the interior of the dome of Florence Cathedral Santa Maria del Fiore, one of the UNESCO World Heritage sites and among the highest profile buildings in existence. Its result shows the effectiveness of the technique as a tool to radiograph thick structures and image denser object inside them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Protein Arrays for Quantitative Systems Analysis of the Dynamics of Signaling Pathway Interactions

Astronauts and workers in nuclear plants who repeatedly exposed to low doses of ionizing radiation (IR, <10 cGy) are likely to incur specific changes in signal transduction and gene expression in various tissues of their body. Remarkable advances in high throughput genomics and proteomics technologies enable researchers to broaden their focus from examining single gene/protein kinetics to better understanding global gene/protein expression profiling and biological pathway analyses, namely Systems Biology. An ultimate goal of systems biology is to develop dynamic mathematical models of interacting biological systems capable of simulating living systems in a computer. This Glue Grant is to complement Dr. Boothman’s existing DOE grant (No. DE-FG02-06ER64186) entitled “The IGF1/IGF-1R-MAPK-Secretory Clusterin (sCLU) Pathway: Mediator of a Low Dose IR-Inducible Bystander Effect” to develop sensitive and quantitative proteomic technology that suitable for low dose radiobiology researches. An improved version of quantitative protein array platform utilizing linear Quantum dot signaling for systematically measuring protein levels and phosphorylation states for systems biology modeling is presented. The signals are amplified by a confocal laser Quantum dot scanner resulting in ~1000-fold more sensitivity than traditional Western blots and show the good linearity that is impossible for the signals of HRP-amplification. Therefore this improved protein array technology is suitable to detect weak responses of low dose radiation. Software is developed to facilitate the quantitative readout of signaling network activities. Kinetics of EGFRvIII mutant signaling was analyzed to quantify cross-talks between EGFR and other signaling pathways.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of InGaN/GaN quantum well growth using monochromated valence electron energy loss spectroscopy

The early stages of InGaN/GaN quantum well growth for In-reduced conditions have been investigated for varying thickness and composition of the wells. The structures were studied by monochromated scanning transmission electron microscopy–valence electron energy loss spectroscopy spectrum imaging at high spatial resolution. It is found that beyond a critical well thickness and composition, quantum dots (width >20 nm) are formed inside the well. These are buried by compositionally graded InGaN, which is formed as GaN is grown while residual In is incorporated into the growing structure. It is proposed that these dots act as carrier localization centers inside the quantum wells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Noise-resolution tradeoffs in x-ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. Methods: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 lp/mm was adopted as a single-parameter measure of local spatial resolution. Results: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. Conclusions: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.

60 APPLIED LIFE SCIENCES↗

Universal and State-Resolved Imaging Studies of Chemical Dynamics

The focus of this program is on combining universal ion imaging probes providing global insight, with high-resolution state-resolved probes providing quantum mechanical detail, to develop a molecular-level understanding of chemical phenomena. Particular emphasis is placed upon elementary reactions important in understanding and predicting combustion chemistry. This research is conducted using state-of-the-art molecular beam machines, photodissociation, reactive scattering, and vacuum ultraviolet lasers in conjunction with ion imaging techniques. An ongoing parallel effort is made to develop new tools and experimental methods with which to achieve these goals. A total of 29 publications are reported and DOIs are appended here. This work was included in 8 Ph.D. theses and two M.S. Theses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Use of Graphene and Its Derivatives for Liquid-Phase Transmission Electron Microscopy of Radiation-Sensitive Specimens

We present that one of the key challenges facing liquid-phase transmission electron microscopy (TEM) of biological specimens has been the damaging effects of electron beam irradiation. The strongly ionizing electron beam is known to induce radiolysis of surrounding water molecules, leading to the formation of reactive radical species. In this study, we employ DNA-assembled Au nanoparticle superlattices (DNA-AuNP superlattices) as a model system to demonstrate that graphene and its derivatives can be used to mitigate electron beam-induced damage. We can image DNA-AuNP superlattices in their native saline environment when the liquid cell window material is graphene, but not when it is silicon nitride. In the latter case, initial dissociation of assembled AuNPs was followed by their random aggregation and etching. Using graphene-coated silicon nitride windows, we were able to replicate the observation of stable DNA-AuNP superlattices achieved with graphene liquid cells. We then carried out a correlative Raman spectroscopy and TEM study to compare the effect of electron beam irradiation on graphene with and without the presence of water and found that graphene reacts with the products of water radiolysis. We attribute the protective effect of graphene to its ability to efficiently scavenge reactive radical species, especially the hydroxyl radicals which are known to cause DNA strand breaks. We confirmed this by showing that stable DNA-AuNP assemblies can be imaged in silicon nitride liquid cells when graphene oxide and graphene quantum dots, which have also recently been reported as efficient radical scavengers, are added directly to the solution. Lastly, we anticipate that our study will open up more opportunities for studying biological specimens using liquid-phase TEM with the use of graphene and its derivatives as biocompatible radical scavengers to alleviate the effects of radiation damage.

36 MATERIALS SCIENCE↗

Filming enhanced ionization in an ultrafast triatomic slingshot

Abstract Filming atomic motion within molecules is an active pursuit of molecular physics and quantum chemistry. A promising method is laser-induced Coulomb Explosion Imaging (CEI) where a laser pulse rapidly ionizes many electrons from a molecule, causing the remaining ions to undergo Coulomb repulsion. The ion momenta are used to reconstruct the molecular geometry which is tracked over time (i.e., filmed) by ionizing at an adjustable delay with respect to the start of interatomic motion. Results are distorted, however, by ultrafast motion during the ionizing pulse. We studied this effect in water and filmed the rapid “slingshot” motion that enhances ionization and distorts CEI results. Our investigation uncovered both the geometry and mechanism of the enhancement which may inform CEI experiments in many other polyatomic molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermochemistry of the smallest QOOH radical from the roaming fragmentation of energy selected methyl hydroperoxide ions

Here, the dissociative photoionization processes of methyl hydroperoxide (CH 3 OOH) have been studied by imaging Photoelectron Photoion Coincidence (iPEPICO) spectroscopy experiments as well as quantum-chemical and statistical rate calculations. Energy selected CH 3 OOH + ions dissociate into CH 2 OOH + , HCO + , CH 3 + , and H 3 O + ions in the 11.4–14.0 eV photon energy range. The lowest-energy dissociation channel is the formation of the cation of the smallest “QOOH” radical, CH 2 OOH + . An extended RRKM model fitted to the experimental data yields a 0 K appearance energy of 11.647 ± 0.005 eV for the CH 2 OOH + ion, and a 74.2 ± 2.6 kJ mol -1 mixed experimental-theoretical 0 K heat of formation for the CH 2 OOH radical. The proton affinity of the Criegee intermediate, CH 2 OO, was also obtained from the heat of formation of CH 2 OOH + (792.8 ± 0.9 kJ mol -1 ) to be 847.7 ± 1.1 kJ mol - 1, reducing the uncertainty of the previously available computational value by a factor of 4. RRKM modeling of the complex web of possible rearrangement-dissociation processes was used to model the higher-energy fragmentation. Supported by Born–Oppenheimer molecular dynamics simulations, we found that the HCO + fragment ion is produced through a roaming transition state followed by a low barrier. Lastly, H 3 O + is formed in a consecutive process from the CH 2 OOH + fragment ion, while direct C–O fission of the molecular ion leads to the methyl cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An ab initio investigation of the mechanisms of photodissociation in bromobenzene and iodobenzene

In concert with the latest experiment of velocity imaging technique [X. P. Zhang et al., ChemPhysChem 9, 1130 (2008)], quantum chemical calculations with relativistic effect were performed on the photodissociation of bromobenzene (BrPh) and iodobenzene (IPh) at 266 nm. The method of multistate second order multiconfigurational perturbation theory in conjunction with spin-orbit interaction through complete active space state interaction was employed to calculate the potential energy curves for the ground and low-lying excited states of BrPh and IPh along their photodissociation reaction coordinates. The dissociation mechanisms with products of X({sup 2}P{sub 3/2}) and X{sup *}({sup 2}P{sub 1/2}) (X=Br,I) states were clarified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of Small Pore Microchannel Plates

Small pore size microchannel plates (MCP's) are needed to satisfy the requirements for future high resolution small and large format detectors for astronomy. MCP's with pore sizes in the range 5 micron to 8 micron are now being manufactured, but they are of limited availability and are of small size. We have obtained sets of Galileo 8 micron and 6.5 micron MCP's, and Philips 6 micron and 7 micron pore MCP's, and compared them to our larger pore MCP Z stacks. We have tested back to back MCP stacks of four of these MCP's and achieved gains greater than 2 x 1O(exp 7) with pulse height distributions of less than 40% FWHM, and background rates of less than 0.3 events sec(exp -1) cm(exp -2). Local counting rates up to approx. 100 events/pore/sec have been attained with little drop of the MCP gain. The bare MCP quantum efficiencies are somewhat lower than those expected, however. Flat field images are characterized by an absence of MCP fixed pattern noise.

Siegmund, O. H. W.↗

Quantum Well Infrared Photodetectors (QWIPs) for Astronomy

In recent years, many research groups in the world have demonstrated large format Quantum Well Infrared Photodetector (QWIP) focal plane arrays for various thermal imaging applications. QWIPs as opposed to conventional low bandgap infrared detectors, are limited by thermionic dark current and not tunneling currents down to 30K or less. As a result the performance of QWIPs can be substantially improved (orders of magnitude) by cooling from 70K to 30K. Cooling does not induce any nonuniformity or 1/f noise in QWIP focal plane arrays. In this paper, we discuss the development of highly uniform long- wavelength QWIPs for astronomical applications.

Gunapala, S. D.↗

Resolution of the Klein Paradox within Relativistic Quantum Mechanics

We present a resolution of the Klein paradox within the framework of one-particle relativistic quantum mechanics (no pair production). Not only reflection becomes total but the vacuum remains neutral as well. This is accomplished by replacing the pair production process with virtual negative energy ''incidence'' within the barrier in a process analogous to the introduction of image charges in electrostatic and virtual sources in optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Foucault imaging by using non-dedicated transmission electron microscope

An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strain-induced fundamental optical transition in (In,Ga)As/GaP quantum dots

The nature of the ground optical transition in an (In,Ga)As/GaP quantum dot is thoroughly investigated through a million atoms supercell tight-binding simulation. Precise quantum dot morphology is deduced from previously reported scanning-tunneling-microscopy images. The strain field is calculated with the valence force field method and has a strong influence on the confinement potentials, principally, for the conduction band states. Indeed, the wavefunction of the ground electron state is spatially confined in the GaP matrix, close to the dot apex, in a large tensile strain region, having mainly Xz character. Photoluminescence experiments under hydrostatic pressure strongly support the theoretical conclusions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗