Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An investigation of a mathematical model of an optically pumped Ti(3+):Al2O3 laser system

During the last several years, solid state lasers were developed that have the potential for meeting rigorous performance requirements for space-based remote sensing of the atmosphere. In order to design a stable and efficient laser and to understand the effect on laser output of changes in the physical and design parameters, an understanding of the development of the dynamical processes of the laser is necessary. Typically, the dynamical processes in a laser system are investigated via rate equations describing the evolution of the occupancy in the electronic levels and of the photon density in the laser cavity. There are two approaches to this type of study. Most often, for the sake of simplicity, the spatial variations of the dynamic variables in the laser system are disregarded and the mathematical model consists of a system of first order nonlinear ordinary differential equations (ODE). The second approach is to take into account both spatial and temporal variations in the dynamic variables in the laser cavity. The resulting model consists of a first order semilinear system of partial differential equations (PDE). The model which was studied was studied was generic in the sense that it was a four-level laser system, but the parameters used in the numerical study were specific to Titanium-doped sapphire. For simplicity, a constant, spatially uniform pumping scheme was considered. In addition, a simplification of the model was made so that it treats a single lasing wavelength with a narrow bandwidth. The purpose was to investigate both versions of the mathematical model and to determine whether the numerical solutions are similar both qualitatively and quantitatively. The systems of ordinary differential equations were solved numerically using a Runge-Kutta-Fehlberg algorithm which was very efficient for typical values of the physical parameters. A numerical scheme, based on the Modified Euler method, for computing solutions to the system of partial differential equations was developed and implemented. The PDE model was solved numerically at the expense of greatly increased computer time.

Roberts, Lila F.↗

UEDGE modeling of plasma detachment of CFETR with ITER ‐like divertor geometry by external impurity seeding

Abstract Efficient handling of high heat flux on the plasma‐facing components, particularly the divertor targets, poses a significant challenge for the Chinese Fusion Engineering Testing Reactor (CFETR) with fusion power of Gigawatt. This work investigates the divertor plasma detachment of CFETR with a standard ITER‐like divertor geometry by neon (Ne) or argon (Ar) impurity seeding using UEDGE code. The cross‐field drifts terms are switched off, and fluid neutral models and a “fixed‐fraction” impurity model are applied to enable efficient simulations for the study of CFETR detachment. In order to reduce the heat load on the divertor targets below the acceptable level (<10 MW/m 2 ), the impurity fraction ( f ), pumping speed ( S ), and upstream density are varied to identify the suitable operations window during Ne seeding. The effects of Ne and Ar impurities on the plasma detachment are compared. It is found that with the power across the core‐edge interface P SOL = 200 MW and separatrix density of 2.8 10 19 , Ne impurity fraction ≥1.7%, and Ar impurity fraction ≥0.24% can achieve the partial detachment. Achieving similar total radiation power (˜148 MW), the Ne fraction is 2.3% and the Ar fraction is 0.24%. Moreover, the simulation results indicate that Ar exhibits better power radiation efficiency and core compatibility compared with Ne.

Zhang, M. Z.↗

High-efficiency narrow-bandwidth KTP optical parametric oscillator for kHz–MHz planar laser-induced fluorescence

The electronic excitation of key combustion species or flow tagging of chemical species requires a narrowband tunable UV source. In this work, a potassium titanyl phosphate (KTP) burst-mode optical parametric oscillator (OPO) pumped by a 532 nm laser is developed to generate a spectrally narrow signal and an idler output with 1.48 ± 0.19 cm −1 bandwidth without the need for injection seeding. The idler (1410–1550 nm range) is further mixed with 355 or 266 nm to generate 284 or 226 nm for OH or NO planar laser-induced fluorescence (PLIF), respectively, with up to 1.9% conversion efficiency from 1064 nm to the UV. MHz-rate burst profiles are reported, and OH and NO PLIF are demonstrated in a rotating detonation combustor at rates up to 200 kHz.

Webb, Austin M. (ORCID:0000000155897474)↗

Ultrafast adiabatic frequency conversion

Abstract Ultrafast adiabatic frequency conversion is a powerful method, capable of efficiently and coherently transfering ultrashort pulses between different spectral ranges, e.g. from near-infrared to mid-infrared, visible or ultra-violet. This is highly desirable in research fields that are currently limited by available ultrafast laser sources, e.g. attosecond science, strong-field physics, high-harmonic generation spectroscopy and multidimensional mid-infrared spectroscopy. Over the past decade, adiabatic frequency conversion has substantially evolved. Initially applied to quasi-monochromatic, undepleted pump interactions, it has been generalized to include ultrashort, broadband, fully-nonlinear dynamics. Through significant theoretical development and experimental demonstrations, it has delivered new capabilities and superior performance in terms of bandwidth, efficiency and robustness, as compared to other frequency conversion techniques. This article introduces the concept of adiabatic nonlinear frequency conversion, reviews its theoretical foundations, presents significant milestones and highlights contemporary ultrafast applications that may, or already do, benefit from utilizing this method.

Margules, Peleg (ORCID:0000000335573370)↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phonon-enhanced nonlinearities in hexagonal boron nitride

Abstract Polar crystals can be driven into collective oscillations by optical fields tuned to precise resonance frequencies. As the amplitude of the excited phonon modes increases, novel processes scaling non-linearly with the applied fields begin to contribute to the dynamics of the atomic system. Here we show two such optical nonlinearities that are induced and enhanced by the strong phonon resonance in the van der Waals crystal hexagonal boron nitride (hBN). We predict and observe large sub-picosecond duration signals due to four-wave mixing (FWM) during resonant excitation. The resulting FWM signal allows for time-resolved observation of the crystal motion. In addition, we observe enhancements of third-harmonic generation with resonant pumping at the hBN transverse optical phonon. Phonon-induced nonlinear enhancements are also predicted to yield large increases in high-harmonic efficiencies beyond the third.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advances in 3D transient plasma dynamics and control through MHD and hybrid fluid-kinetic simulations with JOREK

Transient phenomena and their control are of high relevance in magnetic confinement fusion plasmas to guarantee a stable and safe plasma operation. Interpretative simulations can maximize the insights gained from experiments on present machines and predictive simulations can help in the preparation of design, mitigation techniques and operational scenarios for future devices. In this article, we provide an overview of recent advances and novel scientific results obtained with the 3D non-linear hybrid fluid-kinetic code JOREK, covering physics of plasma transients from the core to the scrape-off layer (SOL) both for tokamak and stellarator devices. Substantial progress was made in the physics understanding, model validation with experiments and experiment interpretation, thus, giving confidence for predictions to devices like DTT, ITER and DEMO. The topics addressed comprise a wide range: the edge physics of new operation scenarios and edge localized mode suppression; major disruptions with a focus on runaway electrons and vertical displacement events as well as disruption mitigation by shattered pellet injection; the physics mechanisms and operational limits of the flux pumping regime for sawtooth control; MHD limits of stellarators and work towards incorporating advanced edge/SOL/exhaust dynamics; continuing improvements of the code for more efficient hybrid simulations on conventional and accelerated high performance computing architectures.

disruptions↗

Tulane virus protease as a structural surrogate for inhibitor screening of human norovirus proteases

Human norovirus (HuNoV) is a significant cause of gastroenteritis worldwide, affecting people of all age groups. There are currently no vaccines or drugs available, leaving susceptible populations vulnerable to severe or protracted illness. A HuNoV cultivation system is pivotal for screening norovirus antivirals. While the human intestinal enteroid cultivation system allows robust replication of multiple HuNoV strains, it presents technical and cost barriers. Tulane virus (TV), a surrogate for HuNoV, replicates well in monkey kidney cell lines and is closely related to norovirus in cellular biology. Here, we determined the structures of TV protease (TV-Pro) alone and in complex with rupintrivir, a picornavirus inhibitor that also inhibits HuNoV proteases (HuNoV-Pro). Our data validate TV as an efficient surrogate system for rapid screening of HuNoV protease inhibitors. The TV protease structure exhibits significant backbone similarity to the GI.1 HuNoV protease in the substrate-binding domain, with the BII-CII loop in an open conformation stabilized by hydrogen bonds as present in the GI.1 protease. Structural differences in the S2 pocket and two amino acid changes in the S4 pocket result in slightly altered P2 and P4 substrate and inhibitor conformations. Despite these differences, we confirm previous findings that the TV protease can cleave the GI.1 and GII HuNoV polyprotein substrates with high and moderate efficiency, respectively. We found that rupintrivir efficiently inhibits TV protease in vitro and inhibits TV replication in cell culture with similar efficacy in combination with P-glycoprotein efflux pump inhibitors. We conclude that TV is a valuable surrogate for HuNoV protease inhibitor screening and outline strategies to improve its compatibility as such.

crystal structures↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2.07-micron CW diode-laser-pumped Tm,Ho:YLiF4 room-temperature

Continuous-wave action is obtained at 2.07 microns from a 2-mm-long Tm-sensitized Ho:YLiF4 crystal at room temperature when longitudinally pumped by a pair of diode-laser arrays. Laser output power at 300 K is 26 mW, with a 30-percent slope efficiency and a lasing threshold of 108 mW. A maximum output power of 187 mW is obtained from a 4-mm-long crystal at 77 K, with a 67 percent slope efficiency. A preliminary demonstration of cavity Q switching produced 165 microJ of pulse energy at a repetition rate of 100 Hz.

Hemmati, Hamid↗

A space-based combined thermophotovoltaic electric generator and gas laser solar energy conversion system

This paper describes a spaceborne energy conversion system consisting of a thermophotovoltaic electric generator and a gas laser. As a power source for the converson, the system utilizes an intermediate blackbody cavity heated to a temperature of 2000-2400 K by concentrated solar radiation. A double-layer solar cell of GaAs and Si forms a cylindrical surface concentric to this blackbody cavity, receiving the blackbody radiation and converting it into electricity with cell conversion efficiency of 50 percent or more. If the blackbody cavity encloses a laser medium, the blackbody radiation can also be used to simultaneously pump a lasing gas. The feasibility of blackbody optical pumping at 4.3 microns in a CO2-He gas mixture was experimentally demonstrated.

Yesil, Oktay↗

Space power demonstrator engine, phase 1

The design, analysis, and preliminary test results for a 25 kWe Free-Piston Stirling engine with integral linear alternators are described. The project is conducted by Mechanical Technology under the direction of LeRC as part of the SP-100 Nuclear Space Power Systems Program. The engine/alternator system is designed to demonstrate the following performance: (1) 25 kWe output at a specific weight less than 8 kg/kW; (2) 25 percent efficiency at a temperature ratio of 2.0; (3) low vibration (amplitude less than .003 in); (4) internal gas bearings (no wear, no external pump); and (5) heater temperature/cooler temperature from 630 to 315 K. The design approach to minimize vibration is a two-module engine (12.5 kWe per module) in a linearly-opposed configuration with a common expansion space. The low specific weight is obtained at high helium pressure (150 bar) and high frequency (105 Hz) and by using high magnetic strength (samarium cobalt) alternator magnets. Engine tests began in June 1985; 16 months following initiation of engine and test cell design. Hydrotest and consequent engine testing to date has been intentionally limited to half pressure, and electrical power output is within 15 to 20 percent of design predictions.

Source record↗

A Shocking New Pump

Hydro Dynamics, Inc. received a technical helping hand from NASA that made their Hydrosonic Pump (HPump) a reality. Marshall engineers resolved a bearing problem in the rotor of the pump and recommended new bearings, housings and mounting hardware as a solution. The resulting HPump is able to heat liquids with greater energy efficiency using shock waves to generate heat.

Source record↗

New Hydrophilic, Composite Membranes for Air Removal from Water Coolant Systems

Liquid coolants are commonly used as thermal transport media to increase efficiency and flexibility in aerospace vehicle design. The introduction of gas bubbles into the coolant can have negative consequences, including: loss of centrifugal pump prime, irregular sensor readings, and blockage of coolant flow to remote systems. One solution to mitigate these problems is the development of a passive gas removal device, or gas trap, installed in the flight cooling system. In this study, a new hydrophilic, composite membrane has been developed for passage of the coolant fluid and retention of gas bubbles. The trapped bubbles are subsequently vented from the system by a thin, hydrophobic, microporous membrane. The original design for this work employed a homogeneous membrane that was susceptible to fouling and pore plugging. Spare gas traps of this variety have degraded during storage, and recreation of the membranes has been complicated due to problems with polymer duplication and property variations in the final membranes. In this work, replacements have been developed based on deposition of a hydrophilic polymer on the bore-side of a porous polyethylene (PE) tube. The tube provides excellent chemical and mechanical stability, and the hydrophilic layer provides retention of gas bubbles. Preliminary results have shown that intimate contact is required between the deposited layer and the substrate to overcome material differences. This has been accomplished by presoaking the membrane tube in the solvent to raise its surface energy. Polymer solutions of various concentrations have been used to promote penetration of the polymer layer into the porous substrate and to control separation layer thickness. The resulting composite membranes have shown repeatable decrease in nitrogen permeability, which is indicative of a decrease in membrane pore size. Studies with water permeation have yielded similar results. We have observed some swelling of the added polymer layer, which causes a slight decrease in membrane pore size, and should result in improved bubble retention. Preliminary studies have also been performed on gas retention in flowing systems. Initial results have been promising, with negligible gas permeation for the coated membranes compared to 100% gas permeation in the uncoated tube.

Ritchie, Stephen M. C.↗

The E3 Initiative

The Department of Energy’s Building Technologies Office is developing a national initiative focused on efficient and clean heating and cooling systems in residential and commercial buildings, making it easier to afford and install high-performance heat pump solutions.

HVAC, residential, commercial, Cold Climate Heat P↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗