Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Swab Tensile Testing Results and Procedures - PA11 Rev. 10 Swabs

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. All swabs were provided by HP and were the PA11 material and Rev 10 design. All of the swabs were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. The “Aged” swabs that were not pre-treated using the Autoclave, were tested 7 days after those that were not “Aged.”

36 MATERIALS SCIENCE↗

Measures and Metrics Report for Corporate Procedures (Q4 FY2016)

This quarterly summary report addresses measures and metrics as they pertain to risk, evaluation, and corrective action records in the Assurance Information System (AIS). This quarterly report is the product of a combined effort by the Risk, Assessments, and Take Action procedure subject matter experts (SMEs) to analyze the available data, primarily data from the AIS corporate application. The purpose of this report is to monitor implementation and identify improvement opportunities.

99 GENERAL AND MISCELLANEOUS↗

Tank 50 Simulant Grout and Toxicity Characteristic Leaching Procedure (TCLP) Results for Methyl Mercury Waste Acceptance Criteria (WAC) Limit

Testing of simulated Tank 50 salt solution grout, spiked with methyl mercury (MeHg) and ionic mercury, used the Toxicity Characteristic Leaching Procedure (TCLP) to evaluate leaching performance with respect to Hg and the Waste Acceptance Criteria (WAC) limits for the Saltstone Production Facility (SPF). This report describes the test parameters for simulant preparation and confirmatory analysis, grout preparation, TCLP leach testing and subsequent leachate analyses. These scoping tests were designed to provide an initial evaluation of the effect of increased MeHg and ionic Hg on the TCLP and were requested by Savannah River Remediation LLC (SRR) through a Technical Assistance Request (TAR). It is expected that this preliminary testing will likely lead to future, more detailed, testing involving the mercury (Hg) WAC and Hg limits with respect to the Tank 50 TCLP for mercury. The TCLP concentrations for total Hg have approached 0.06 mg/L in recent years for Tank 50 radioactive solutions containing up to 105 mg/L of Hg in the form of ionic (Hg(I/II), elemental (Hg(0)) and organo-mercury such as MeHg. In discussions with SRR personnel, it was decided for this non-baseline work to target Hg spike concentrations, using predominately MeHg, in the range of 150 to 350 mg/L total Hg to investigate corresponding Hg TCLP leaching behaviors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2019 Megasun Illumination System. Modifications and Operating Procedure Updates [Slides]

The original operating procedure was nearly 20 years old, though it was on a semi-annual review schedule. Some electrical categories had changed, as well as their risk management assessments. The IWD did not reflect these updated guidelines. No injuries have been reported during nearly 20 years of operation (not a bad record), however, several abnormal conditions came to surface during our Hazard Analysis conversations. One of which included an oil based capacitor malfunction which cracked it’s housing and leaked oil within the 2001 system. Our training and qualifications were updated to reflect LANL’s current standards.

42 ENGINEERING↗

Optimized Microwave Digestion and Quantification Procedure for Boron Carbide samples

A microwave-assisted HNO3-H2SO4-HF digestion system was explored/optimized for the total dissolution of Boron Carbide samples followed by multi-elemental determination using ICP-MS and ICP OES, in order to improve the methods used in a previous try using a microwave-assisted H2O2-HNO3-HF digestion system. The samples were microwave digested to accomplish complete dissolution needed to perform quantitative analysis of their metal content. Two Boron Carbide samples were provided to us: JM10 and JM11. The Boron Carbide samples were completely dissolved at the end of the optimized microwave digestion procedure that was developed. The digested samples were analyzed for metals mostly by ICP MS; few elements were analyzed by ICP-OES. Microwave digestion reactions were performed in a Titan MPS instrument (Perkin Elmer, USA). Titan MPS instrument is equipped with Temperature and Pressure regulations and controlled by software. Each microwave digestion batch contained the samples of interest along with a reagent blank and one certified standard (1632e) in order to (i) compensate for the contaminations present in the reagents, (ii) ensure that the digestion was complete and (iii) that there was a good recovery of all the constituents. The certified standard used (1632e) was provided with USGS certificates of analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Saltstone First Quarter Calendar Year 2021 (1QCY21) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled quarterly for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z00023, Revision 0, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the first quarter of calendar year 2021(1QCY21). One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample”. Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Remediation (SRR). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The 1QCY21 saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Carbon Functional Groups in Pyrolysis Bio-Oils using 13 C NMR: Laboratory Analytical Procedure (LAP)

Pyrolysis is a process that can be used to convert biomass to solid, liquid and gaseous products for use as renewable chemicals and fuels. The liquid fraction, known as “bio-oil” is complex and challenging to characterize, particularly by means of GC/MS, GPC, LC and FT-IR. NMR is capable of analyzing whole bio-oil samples and can provide quantitative results to characterize different functional groups or types of carbon present in bio-oil. This Laboratory Analytical Procedure (LAP) quantifies different carbon functional groups in whole bio-oil samples. This information can be used for comparisons between different pyrolysis experimental conditions or different upgrading processes and catalysts, and also allow for comparisons between bio-oils produced at different facilities.

09 BIOMASS FUELS↗

Guide for Determining Energy Savings from Changes in Operations, Behavior, and Maintenance Procedures

This Guide is intended to provide energy savings estimation methodologies for energy performance improvement actions resulting from changes in operations, behavior and maintenance procedures. These improvements are often referred to as “non-capital measures” because such improvements are typically achievable with little or no capital expenditures. This Guide is designed to assist industrial facilities in quantifying and documenting the energy savings resulting from these types of improvements, including the collection of essential data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Procedure and Results for Contact Thermal Conductance Measurements performed during FY 2021

Weapons Test Engineering groups at LANL are responsible for testing and simulating weapon assemblies and subassemblies in support of qualification and certification of nuclear weapon systems. The complex nature of the assemblies themselves coupled with the loading environments, gives rise to low confidence and high uncertainties in the interpretation of both experimental and simulated results. In an effort to reduce these uncertainties, a project was started at LANL to perform focused and systematic experiments combined with simulations to increase confidence in both arenas. A key goal of the work performed under the Delivery Environments (DE) Testbeds to Reduce Uncertainties in Simulations and Tests TRUST program, focuses on identifying and minimizing sources of uncertainty associated with experimental and computational techniques. Specifically, with the above as motivation, a measurement procedure was developed by MST-8 to perform thermal conductivity measurements on cylinders of both similar and dissimilar metallic systems as a function of loading conditions and varying material interface morphologies between these components.

36 MATERIALS SCIENCE↗

Saltstone Third Quarter Calendar Year 2021 (3QCY21) Toxicity Characteristic Leading Procedure (TCLP) Results

The aqueous waste from Tank 50 (salt solution) is sampled quarterly for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00023, Revision 0, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the third quarter of calendar year 2021(3QCY21). One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample”. Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Remediation (SRR). After at least 28 days cured, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The 3QCY21 saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosivity Screening of Pyrolysis Bio-Oils by Short-Term Alloy Exposures. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Bio-oils contain organic acids and oxygenated compounds that can lead to corrosion issues during bio-oil processing and storage. This Laboratory Analytical Procedure (LAP) allows for rapid screening of a bio-oil's corrosivity without the need for complex equipment and long-term exposures. A robust and repeatable method for assessing the corrosivity of bio-oils is necessary in order to remove materials degradation as an obstacle to research, upgrading, use and storage of bio-oils. This LAP involves the incubation of a representative alloy, 410 stainless steel (410 SS), specimen in bio-oil over a period of 48 hours at 50 degrees C in a sealed container. The corrosive species in the bio-oil react with and deplete alloy elements such as iron (Fe) and/or chromium (Cr) from the specimen into the bio-oil solution. The depletion of Fe and Cr from the specimen results in a significant mass loss that can be recorded. The mass loss is directly correlated to the corrosivity of a bio-oil. Examples of bio-oils in scope include the ones produced by fast pyrolysis and catalytic fast pyrolysis, as well as liquids produced from hydrothermal liquefaction.

09 BIOMASS FUELS↗

Identification and Quantification of Photosynthetic Pigments in Algae (Laboratory Analytical Procedure (LAP))

The Laboratory Analytical Procedure (LAP) outlined here describes a method to quantitatively extract phytopigments from microalgae biomass, as well as to identify and quantify individual pigments based on separation and detection with a High-Performance Liquid Chromatography (HPLC) system coupled to a Diode Array Detector (DAD). Pigments were extracted with greater than 95 % extraction efficiency. Chromatographic conditions allowed for isomeric resolution between pigments and identification based on UV/Vis spectra and comparison to analytical standards.

09 BIOMASS FUELS↗

A new TEVA-DGA chromatography procedure to separate Pu, Am, and Np from bulk U materials

Trace actinides present within uranium (U) material are diagnostic signatures of U processing history. For example, the emplacement of U material within the high neutron-flux environment of a nuclear reactor can cause neutron capture of U to form 241-plutonium ( 241 Pu). Plutonium-241 then decays to progeny isotopes 241-americium ( 241 Am) and 237-neptunium ( 237 Np); therefore, the presence and relative abundances of these trace actinides is indicative of the material’s production history and intended employment (Mayer et al., 2013). During a pre-detonation nuclear forensics investigation, measurement of trace actinide 241 Pu, 241 Am, and 237 Np concentrations by an analytical laboratory may be requested. However, chemically purifying these elements from bulk U is a challenging and involved procedure requiring several sequential chromatography columns across 4+ days. To expedite Pu-Am-Np separation from bulk U material, and to improve the yield recovery of these elements, this DHS Postdoc Fellowship has worked to create a new chromatography separation chemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

PTSFA QA Review of Container Procurements: Information Use Procedure

The purpose of this Packaging and Transportation Safety Functional Area (PTSFA) procedure is to describe the process in which the PTSFA Quality Assurance Engineer (QAE) or designee reviews and approves the documentation associated with the procurements of containers to be used for onsite transfer or off-site transportation of hazardous materials and waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization of a Welding Procedure for Making Critical Aluminum Welds on the LBNF Absorber Core Block

he LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. A weld quality optimization was performed to produce National Aeronautical Standard (NAS) 1514 Class I quality welds on the aluminum core blocks. This was not successful in all cases. An existing Gas Tungsten Arc Welding (GTAW) Welding Procedure Specification (WPS) was fine tuned to minimize, in most cases, and eliminate detectable tungsten inclusions in the welds. All the weld coupons however, passed welding inspection as per the piping code: ASME B31.3 Normal Fluid Service. Tungsten electrode diameter, type, and manufacturer were varied. Some of the samples were pre-heated and others were not. It was observed that larger diameter electrodes, 5/32 in., with pre-heated joints resulted in welds with the least number of tungsten inclusions. It is hypothesized that thinner electrodes breakdown easily and get lodged into the weld pool during the welding process. This breakdown is further enhanced by the large temperature differential between the un-preheated sample and the hot electrode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗