Angled injection: Hybrid fluid film bearings for cryogenic applications

A computational bulk-flow analysis for prediction of the force coefficients of hybrid fluid film bearings with angled orifice injection is presented. Past measurements on water-lubricated hybrid bearings with angle orifice injection have demonstrated improved rotordynamic performance with virtual elimination of cross-coupled stiffness coefficients and nul or negative whirl frequency ratios. A simple analysis reveals that the fluid momentum exchange at the orifice discharge produces a pressure rise in the recess which retards the shear flow induced by journal rotation, and consequently, reduces cross-coupling forces. The predictions from the model correlate well with experimental measurements from a radial and 45 deg angled orifice injection, five recess water hybrid bearings (C = 125 microns) operating at 10.2, 17.4, and 24.6 krpm and with nominal supply pressures equal to 4, 5.5, and 7 MPa. An application example for a liquid oxygen six recess/pad hybrid journal bearing shows the advantages of tangential orifice injection on the rotordynamic force coefficients and stability indicator for forward whirl motions and without performance degradation on direct stiffness and damping coefficients. The computer program generated, 'hydrojet,' extends and complements previously developed codes.

SanAndres, Luis↗

Optical emission spectroscopy and imaging of low-pressure N2 plasmas generated by intense fast-pulsed electron beams

An optical emission spectroscopic (OES) and imaging characterization is conducted on N2 plasmas generated by a 100 keV fast-pulsed electron beam. The electron beams are injected into an N2 gas filled volume with a current of 4.5 kA (300 A/cm2) and a 100 ns pulse width. The characterization is conducted at the pressures, 1 Torr and 0.1 Torr, corresponding to two distinct regimes that exhibit significantly different plasma dynamics. Beam impact ionization is shown to be a primary mechanism for producing low temperature plasmas at 1 Torr during beam output. After beam termination, ionization by an inductive electric field becomes the primary mechanism for plasma formation later in time for both pressures. OES and plasma imaging are used in this work as a diagnostic tool to track the distribution of electronic, vibrational, and rotational state transitions and ionized species. This is achieved with the use of a multi-resolution suite of spectrometers capable of acquiring time-resolved spectra. Vibrational and rotational bands of the N2 second positive system (C3Πu→B3Πg) and the N2+ first negative system (B2Σu+→X2Σg+) are identified in both regimes as well as N+ states exclusively in the lower pressure regime. Vibrational and rotational spectra are shown to track the evolution of the time-varying plasma current. Plasma imaging also reveals spatially nonuniform plasma emission at 0.1 Torr. A few hundred shots are recorded to fully characterize the emissions, and results are shown to be highly reproducible (≤±1% with 2σ confidence).

Kaiser, E. R. (ORCID:0000000336493938)↗

CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report)

Our group has recently developed StimuFrac, a non-toxic stimuli-responsive fracturing fluid consisting of a CO 2 -reactive polymer which has shown at the lab-scale to consistently fracture rock cores at significantly lower net pressures in a range of representative geothermal pressure/temperature conditions. However, until now the mechanism/s responsible for more effective fracturing, of critical importance to optimize fracturing performance as well as strategize injection methodologies for field deployment, was not understood. In this document, we report (1) on the two main mechanisms responsible for fracturing rock at lower net pressures with StimuFrac; (2) the phase behavior of StimuFrac/CO 2 under geothermal wellbore conditions; and (3) based on high-temperature true triaxial stimulations, detailed evidence that StimuFrac/CO 2 is the best performing stimulation fluid under EGS T/P conditions as compared to water, waterless CO 2 , and CO 2 /water fracturing fluids. This is because i) it requires significantly lower volumes of CO 2 due to its reduced leak off into the formation by the crosslinked polymer solution; ii) large fractures can be generated reproducibly at both low and high CO 2 injection flow rates, and iii) the reversible (previously reported) viscosity increase of StimuFrac could be beneficial to transport proppants when they become available for EGS. These results were particularly evident for hot nearly dry rock as well as partially and nearly fully water-saturated granitic rock. GTO requires StimuFrac to be evaluated in fully water-saturated rock to determine whether the above-described performance applies under these conditions. Since (1) GTO considers there is no enough evidence for Sa different StimuFrac formulation to work below 90C (where full water-saturation in an open system is possible) and (2) no polyaxial loading frame larger than a few centimeters that can do hydraulic fracturing tests while maintaining the rock sample fully saturated with water at 200 C exists; PNNL concludes that the only way to determine if StimuFrac represents an advanced fracturing fluid alternative for EGS, is to perform a stimulation in an actual EGS reservoir.

15 GEOTHERMAL ENERGY↗

Injection slot location for boundary-layer control in shock-induced separation

An experimental investigation of the effect of tangential air injection, when the injection slot is located inside of what would otherwise have been the dead air zone in a separated flow, in controlling shock-induced turbulent boundary layer separation is presented. The experiments were carried out at a free-stream Mach number of 2.5 in the separated flow induced by a compression corner with a 20 deg angle. The observations made were wall static pressures, pitot profiles, and schlieren visualizations of the flow. The results show that the present location for injection is more effective in suppressing boundary-layer separation than the more conventional one, where the slot is located upstream of where separation would occur in the absence of injection.

Viswanath, P. R.↗

Monitoring Offshore CO 2 Sequestration Using Marine CSEM Methods; Constraints Inferred from Field- and Laboratory-Based Gas Hydrate Studies

Offshore geological sequestration of CO 2 offers a viable approach for reducing greenhouse gas emissions into the atmosphere. Strategies include injection of CO 2 into the deep-ocean or ocean-floor sediments, whereby depending on pressure–temperature conditions, CO 2 can be trapped physically, gravitationally, or converted to CO 2 hydrate. Energy-driven research continues to also advance CO 2 -for-CH 4 replacement strategies in the gas hydrate stability zone (GHSZ), producing methane for natural gas needs while sequestering CO 2 . In all cases, safe storage of CO 2 requires reliable monitoring of the targeted CO 2 injection sites and the integrity of the repository over time, including possible leakage. Electromagnetic technologies used for oil and gas exploration, sensitive to electrical conductivity, have long been considered an optimal monitoring method, as CO 2 , similar to hydrocarbons, typically exhibits lower conductivity than the surrounding medium. We apply 3D controlled-source electromagnetic (CSEM) forward modeling code to simulate an evolving CO 2 reservoir in deep-ocean sediments, demonstrating sufficient sensitivity and resolution of CSEM data to detect reservoir changes even before sophisticated inversion of data. Laboratory measurements place further constraints on evaluating certain systems within the GHSZ; notably, CO 2 hydrate is measurably weaker than methane hydrate, and >1 order of magnitude more conductive, properties that may affect site selection, stability, and modeling considerations.

58 GEOSCIENCES↗

Laboratory simulation of pelagic asteroidal impact Atmospheric injection, benthic topography, and the surface wave radiation field

The hypervelocity impact (1.25-6 km/s) of projectiles into water overlying unconsolidated strata is reported for a variety of water depths. Variation of the background atmospheric pressure is found to be an important additional parameter. The relation of these exploratory experiments to pelagic impact of asteroidal-sized objects is discussed from the standpoint of atmospheric injection of sea water, the modification of bottom (benthic) topography, and the generation of a field of mega-amplitude sea waves and their propagation away from the source.

Gault, D. E.↗

Simulated CO 2 storage efficiency factors for saline formations of various lithologies and depositional environments using new experimental relative permeability data

Saline formations are attractive geologic reservoirs for permanent carbon dioxide (CO 2 ) storage. Here, the U.S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) has worked to develop and refine methods and tools for the calculation of CO 2 storage potential in subsurface reservoirs. DOE-NETL's CO 2 -SCREEN provides an online tool for executing these storage methods. CO 2 storage efficiency terms are input parameters in DOE-NETL's methods and equations embedded in the CO 2 -SCREEN, which assesses pore space available for CO 2 storage. In this work, a modeling workflow was initiated to refine two CO 2 storage efficiency terms - volumetric displacement (E V ) and microscopic displacement (E d ). The models are based on new experimental relative permeability data that are specific to homogenous lithology and depositional environments of key subsurface saline formations targeted for CO 2 storage. In future work, heterogenous features will be added to this initial modeling effort to update efficiency factors as described in DOE-NETL's methods and CO 2 -SCREEN tool. E V accounts for the volume utilized in the reservoir under the areal plume, while E d accounts for saturation values in the plume to assess efficiency of CO 2 storage at the pore scale. The results of this work are significant in that prior values were based on a limited geologically non-specific relative permeability data set that were collected prior to 2009. Specifically, we applied numerical simulations using TOUGH3 models to update CO 2 storage efficiency values for supercritical CO 2 injection into brine-saturated reservoirs for three lithologies (clastics, limestone, dolomite) and six depositional environments (Marginal Marine, Strand Plain, Deltaic Complex Fluvial, Aeolian, Shallow Marine, and Reef) that have a high potential for geologic CO 2 storage. Experimental relative permeability data in cores from these environments were utilized in the models with corresponding rock type/sedimentary environment. Results of this study showed that dolomite followed by limestone generated higher ranges of storage efficiency compared to clastics. The updated values provided a tighter efficiency range for clastics, lower P 10 but higher P 90 range for limestone, and higher P 10 and P 90 for dolomite. In general, tighter reservoirs with relatively low permeability and porosity were associated with higher E V and E d , showing efficient reservoir and pore utilization in these scenarios. High reservoir pressure and temperature associated with increasing depth increased the E V , and high CO 2 injection rates resulted in increases in E V and E d , while the impact of permeability anisotropy was minimal after the 30-year injection period.

03 NATURAL GAS↗

Investigation of fuel film formation and soot emissions in a GDI engine during cold-start with Split-injection strategies

This study investigates the impact of fuel-film formation on engine-out soot emissions in a gasoline direct injection (GDI) engine under cold-start conditions. Split-injection strategies were applied by varying the number of injections, injection duration, and total fuel quantity to affect wall wetting and control the average in-cylinder equivalence ratio. A combined experimental and numerical approach was employed to analyze fuel-film deposition, combustion efficiency, and engine-out soot and unburnt hydrocarbons (UHC) emissions. In particular, fuel film distribution estimated by means of non-reacting, 3-D, computational fluid dynamics (CFD) simulations, together with experimentally measured soot data, were used to investigate fuel film formation and its role in soot generation. In the experiments, a skip-fired engine control strategy was applied to mimic the transient nature of engine cold-start operation. The results indicate that, under the same total number of injections, increasing the average in-cylinder equivalence ratio through longer injection durations improves combustion stability, as indicated by the decrease of the coefficient of variation of IMEP n (Net Indicated Mean Effective Pressure) from 6.0 % to 0.6 %. However, this strategy leads to higher soot emissions, which increased by nearly an order of magnitude, primarily due to enhanced wall-film formation. In contrast, increasing the number of injections while maintaining a constant equivalence ratio significantly impacts fuel-film deposition and, consequently, soot emissions, with a fivefold reduction of the measured engine-out soot, decreasing from 3.5 mg to 0.7 mg. A soot-film correlation was developed and achieved a high coefficient of determination (r 2 = 0.95) and was further extended to account for spark timing effects. These findings confirm the effectiveness of split-injection for avoiding wall film formation and soot emissions, and the critical role of fuel film in soot generation, supporting the hypothesis that pool fires play a crucial role in contributing to soot formation under these cold-start conditions. In conclusion, the study also indicates the value of a predictive soot-film correlation for developing cold-start emission control strategies.

Engine Cold-start↗

Fracture Network Quantification during CO2 Injection

This is the presentation prepared for the ARMA 2025 (59th US Rock Mechanics/Geomechanics Symposium) Conference held in Santa Fe, New Mexico, June 8-11, 2025. Accurate mapping and quantification of these networks are essential to ensure the integrity of CO2 storage reservoirs, understand and reduce potential leakage, and maintain long-term environmental safety. This study presents a novel machine learning-driven approach, integrated with geomechanical analysis, to quantify fracture networks and assess their spatial distribution during CO2 injection. This paper combines microseismic monitoring data with principles of hydraulic diffusivity and geomechanical analysis to characterize reservoir scale fracture network. The novelty of our approach lies in its capacity to assimilate time-dependent pressure data and microseismicity into a cohesive framework, which not only identifies microseismic triggering fronts but also tracks fracture distribution during active injection. Besides, leveraging image log data and analysis our approach also provides another angle of the insights to solidate the fracture networks understanding and geomechanical impacts. Key results from our study include the detection of over 100 distinct fracture clusters across the injection site, with fracture orientations strongly correlated with the prevailing in-situ stress field.

CO2 storage and sequestration↗

Basement rock hybrid drilling

A system for monitoring and controlling downhole pressure of a well borehole relative to a lithostatic pressure of rock surrounding the borehole is provided. The system can include a millimeter wave drilling apparatus including a gyrotron configured to inject millimeter wave radiation energy into a borehole of a well via a waveguide configured for insertion into the borehole. The borehole can be formed via the millimeter wave drilling apparatus and having a downhole pressure monitored at a bottom of the well. The system can also include a compressor fluidically coupled to the borehole and configured to control the downhole pressure via a gas supplied into and/or received from the borehole. The compressor can be configured to control the downhole pressure relative to a lithostatic pressure determined for rock surrounding the well at the bottom of the well.

Araque, Carlos↗

Fracture Network Quantification during CO2 Injection

This is the conference paper accompanying an oral presentation at the ARMA 2025 (59th US Rock Mechanics/Geomechanics Symposium) Conference held in Santa Fe, New Mexico, June 8-11, 2025. Accurate mapping and quantification of these networks are essential to ensure the integrity of CO2 storage reservoirs, understand and reduce potential leakage, and maintain long-term environmental safety. This study presents a novel machine learning-driven approach, integrated with geomechanical analysis, to quantify fracture networks and assess their spatial distribution during CO2 injection. This paper combines microseismic monitoring data with principles of hydraulic diffusivity and geomechanical analysis to characterize reservoir scale fracture network. The novelty of our approach lies in its capacity to assimilate time-dependent pressure data and microseismicity into a cohesive framework, which not only identifies microseismic triggering fronts but also tracks fracture distribution during active injection. Besides, leveraging image log data and analysis our approach also provides another angle of the insights to solidate the fracture networks understanding and geomechanical impacts. Key results from our study include the detection of over 100 distinct fracture clusters across the injection site, with fracture orientations strongly correlated with the prevailing in-situ stress field.

CO2 storage and sequestration↗

Large eddy simulation of a pressurized reactive fluid–particle system: single-particle dynamics analysis

Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Designing an effective burner plays a vital role in developing new combustion technologies. Because of the high pressure, the volume fraction of particles in a pressurized oxy-combustor could be higher than that in the conventional combustor, therefore, the particle dynamics in the pressurized vessel need to be evaluated accordingly. The present computational work is to predict the influence of the particle size and particle injection location on the particle trajectory. The Stokes number based on turbulence fluctuation, St, is adopted to evaluate the impact of the gas phase on the particulate phase. A large eddy simulation (LES) with the environment pressure of 15 bar and the thermal input of the fuel particle of 100 kWth has been performed by means of the commercial CFD package. It is shown that that in this pressurized environment St << 1 for the 25 µm particles, St ~ 1 for the 100 µm particles, while for the particles exceeding 200 µm St >> 1. The trajectories of the sampling particles from the LES results support this conclusion: the particles less than 100 µm tend to be uniformly distributed in the space while the particles exceeding 200 µm tend to concentrate in the combustor.

Li, Lei↗

The Development and Implementation of a Cryogenic Pressure Sensitive Paint System in the National Transonic Facility

The Pressure Sensitive Paint (PSP) method was used to measure global surface pressures on a model at full-scale flight Reynolds numbers. In order to achieve these conditions, the test was carried out at the National Transonic Facility (NTF) operating under cryogenic conditions in a nitrogen environment. The upper surface of a wing on a full-span 0.027 scale commercial transport was painted with a porous PSP formulation and tested at 120K. Data was acquired at Mach 0.8 with a total pressure of 200 kPa, resulting in a Reynolds number of 65 x 106/m. Oxygen, which is required for PSP operation, was injected using dry air so that the oxygen concentration in the flow was approximately 1535 ppm. Results show qualitative agreement with expected results. This preliminary test is the first time that PSP has been successfully deployed to measure global surface pressures at cryogenic condition in the NTF. This paper will describe the system as installed, the results obtained from the test, as well as proposed upgrades and future tests.

Watkins, A. Neal↗

Autoignition in a premixing-prevaporizing fuel duct using 3 different fuel injection systems at inlet air temperatures to 1250 K

Conditions were determined in a continuous-flow, premixing-prevaporizing duct at which autoignition occurred. Test conditions were representative of an advanced, regenerative-cycle, automotive gas turbine. The test conditions inlet air temperatures from 600 to 1250 K (a vitiated preheater was used), pressures from 170 to 600 kPa, air velocities of 10 to 30 m/sec, equivalence ratios from 0.3 to 1.0, mixing lengths from 10 to 60 cm, and residence times of 2 to 100 ms. The fuel was diesel number 2. The duct was insulated and had an inside diameter of 12 cm. Three different fuel injection systems were used: One was a single simplex pressure atomizer, and the other two were multiple-source injectors. The data obtained with the simplex and one of the multiple-source injectors agreed satisfactorily with the references and correlated with an Arrenhius expression. The data obtained with the other multiple source injector, which used multiple cones to improve the fuel-air distribution, did not correlate well with residence time.

Tacina, R. R.↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

Mode transitions and spoke structures in E × B Penning discharge

Two-dimensional particle-in-cell simulations in the (radial-azimuthal) plane perpendicular to the axial direction of a cylindrical $E$ x $B$ Penning discharge are presented. The low-pressure discharge is self-consistently supported by plasma ionization from the electron beam injected axially, along the direction of the external magnetic field. It is shown that with the increasing strength of the external magnetic field, the discharge undergoes a sequence of transitions between several azimuthal modes. Azimuthal m > 1 spiral arm structures are excited at low magnetic field values as plasma confinement improves and the radial density profile becomes peaked. With a larger field, spiral arms with m > 1 are replaced by the m = 1 spoke mode, most clearly seen in plasma density. A transition from spiral arms to the spoke regime occurs when the plasma potential in the center changes from weakly positive (or zero) to negative. Further increase in the magnetic field results in a well-developed m = 1 spoke mode with additional small-scale higher-frequency m > 1 structures inside and around the spoke. It is shown that while ionization and collisions affect some characteristics of the observed fluctuations, the basic features of the spoke and m > 1 spiral structure remained similar without ionization. The role of energy conservation in small-scale high-frequency modes and spoke dynamics is discussed. It is demonstrated that in regimes with the m = 1 spoke mode, additional m = 4 harmonics of the ion and electron fluxes to the wall appear due to the square boundary. The frequency of the m = 1 mode is weakly affected by the geometry of the boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrogen, Methane, Brine Flow Behavior, and Saturation in Sandstone Cores During H 2 and CH 4 Injection and Displacement

Large-scale underground hydrogen storage (UHS) is a critical component in the emerging hydrogen economy. Knowledge of multiphase flow behavior involving hydrogen in storage reservoir formations is crucial to characterizing hydrogen transport properties and essential for the deliverability and storage operations of UHS. There are still many gaps in fully understanding hydrogen–methane–brine multiphase phase flow that require further investigation. In this work, H 2 and CH 4 were injected through brine-saturated sandstone cores using a tri-axial core holder system fitted with flow rate meters and pressure transducers, while the effluent gas concentrations were analyzed using an online micro gas chromatograph. Brine displacement, permeability, and gas breakthrough curves were measured. We studied the flow behavior of hydrogen and methane in sandstone cores through testing brine displacement by gas injection and comparing the hydrogen displacement of methane with the methane displacement of hydrogen. We also tested the differences between horizontal and vertical flow in brine displacement. The results showed that brine displacement was more efficient in a core with higher permeability and porosity, resulting in a higher initial gas saturation. A higher gas injection rate brought about faster gas breakthrough measured by pore volume and sharper concentration curves. Hydrogen did not exhibit abnormal flow in the sandstone when the flow was horizontal and downward vertical. Gas overriding was observed in brine displacements when the flow was horizontal, with hydrogen showing this behavior more profoundly compared to methane. Downward vertical gas injection induced higher efficiency brine displacement compared to horizontal displacement and resulted in a higher initial gas saturation in the sandstone cores. These findings address critical knowledge gaps regarding gas flow patterns and displacement behaviors during hydrogen injection and recovery phases in UHS facilities using methane as the cushion gas. The insights from this research offer valuable guidance for optimizing UHS systems, ensuring operational efficiency, and advancing sustainable energy solutions in alignment with decarbonization goals.

08 HYDROGEN↗