Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prepare”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of CuFeMnAlO 4+δ oxygen carrier with high attrition resistance and 50-kWth methane/air chemical looping combustion tests

A Copper-Ferri-Manganese-Aluminate spinel (CuFeMnAlO 4+δ ) oxygen carrier, developed at the US Department of Energy’s (DOE) National Energy Technology Laboratory (NETL), shows promising results for chemical looping combustion with methane. Attrition resistance of the spinel oxygen carrier (160–600 µm) produced by a wet agglomeration method was significantly higher than that observed previously with a Copper-Ferri-Aluminate (CuFeAlO 4 ) oxygen carrier. Improved attrition resistance of the novel carrier can be attributed to minimal alumina phase segregation and minimal carbon formation. Heats of reaction measured by differential scanning calorimetry indicated exothermicity during reduction with methane. The total oxygen transfer capacity of the material was about 10.5 wt% at 850 °C. The attrition resistance and the oxygen transfer capacity of the carrier prepared at a commercial manufacturing facility (180 kg) were very similar to observed values during the development phase with the lab scale preparations. The material displays satisfactory methane conversion and significantly high particle durability during a 54 h test campaign conducted in NETL’s 50-kWth chemical looping dual fluid bed reactor unit at temperatures ranging from 700 to 900 °C. Low oxygen carrier make-up cost, due to the use of natural ore and pigment grade raw materials during synthesis and very low attrition rates, exceeded the performance goals determined by systems studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A streamlined tandem tip-based workflow for sensitive nanoscale phosphoproteomics

Effective phosphoproteome of nanoscale sample analysis remains a daunting task, primarily due to significant sample loss associated with non-specific surface adsorption during enrichment of low stoichiometric phosphopeptide. We develop a tandem tip phosphoproteomics sample preparation method that is capable of sample cleanup and enrichment without additional sample transfer, and its integration with our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches provides a streamlined workflow enabling sensitive, high-throughput nanoscale phosphoproteome measurements. This approach significantly reduces both sample loss and processing time, allowing the identification of >3000 (>9500) phosphopeptides from 1 (10) µg of cell lysate using the label-free method without a spectral library. It also enables precise quantification of ~600 phosphopeptides from 100 sorted cells (single-cell level input for the enriched phosphopeptides) and ~700 phosphopeptides from human spleen tissue voxels with a spatial resolution of 200 µm (equivalent to ~100 cells) in a high-throughput manner. The new workflow opens avenues for phosphoproteome profiling of mass-limited samples at the low nanogram level.

59 BASIC BIOLOGICAL SCIENCES↗

The sensitive surface chemistry of Co-free, Ni-rich layered oxides: identifying experimental conditions that influence characterization results

Recent studies have suggested that Co-free, Ni-rich layered cathodes (e.g., doped LiNiO2) can provide promising battery performance for practical applications. However, these layered cathodes suffer from significant surface instability during various stages of the sample history, which generates inherent challenges for achieving stable battery performance and obtaining statistically representative characterization results. To reliably report the surface chemistry of these materials, delicate controls of stepwise sample preparation are required. In this study, we aim to reveal how the surface chemistry of LiNiO2 based materials changes with various environments, including human exhalation, sample storage, sample preparation, electrochemistry cycling, and surface doping. Our results demonstrate that the surface of these materials is highly reactive and prone to alter at various stages of sample handling and characterization. The sensitive surface could impact the interpretation of the surface chemical and structural information, including surface carbonate formation, transition metal reduction and dissolution, and surface reconstruction. Importantly, the heterogeneity of the surface degradation calls for a consolidation of nanoscale, high-resolution characterization, and ensemble-averaged methods in order to improve statistical representation. Furthermore, the doping chemistry can effectively mitigate the surface degradation and improve overall battery performance due to the enhanced surface oxygen retention. Our study highlights the necessity of strict measurements through complementary characterizations at multiple length scales to eliminate unintentional biased conclusions.

surface chemistry, Co-free Ni-rich cathodes, Istab↗

CatMass : software for calculating optimal sample masses for X-ray absorption spectroscopy experiments involving complex sample compositions

This paper presents software for calculating the optimal mass of samples with complex compositions ( e.g. supported metal catalysts) for X-ray absorption spectroscopy (XAS) and scattering measurements. The ability to calculate the sample mass and other relevant parameters needed for an XAS measurement allows experimentalists to be better prepared in terms of detector selection, energy range of scan and overall time needed to complete the measurement, thus increasing efficiency. CatMass builds on existing sample mass calculators allowing users to determine the optimum sample preparation, collection geometry, usable energy range for a scan and approximate edge step of the absorption event. Visualization tools present the absorption calculation results in a format familiar to XAS experimentalists, with the added ability to save calculations and plots for future reference or recalculation. CatMass is a program broadly applicable in catalysis and is helpful for users with complex samples due to composition/stoichiometry or multiple competing elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Personal Resiliency Index

A plethora of information exists in literature focusing on different aspects of personal resilience. There are a number of questionnaires available to measure resilience in different aspects of an individual’s life, such as mental health. However, there is a lack of comprehensive information on the subject of personal resilience to natural and man-made disasters. A Personal Resiliency Index identifying four key areas of resilience related to natural and man-made disasters will help fill this gap by providing individuals an idea of where the stand comparatively to their peers on this topics. As an increasing amount of man-made disasters, natural disasters and pandemics occur, we realize that preparation is key.?“Crisis can be experienced at individual, group and mass levels and at local, regional, national or supra-national levels.” 1? Dr. Ron Fisher, the principal investigator has over 20 years’ critical infrastructure protection including developing vulnerability assessment methodology, risk and resiliency analyses and infrastructure interdependencies. Dr. Fisher and his team will research and develop a voluntary survey which evaluates the user’s personal resilience level to natural and man-made disasters. The research team is focusing on 4 main categories:? financial resilience, cyber security, physical and mental health, and emergency preparedness.?The web based application will?provide a resilience score for each of the categories and also a comprehensive personal resiliency score based on the voluntary survey. The application will also provide feedback to the user on actions to take to become more resilient to natural and man-made disasters. Through this effort, we will also be able to identify the areas where participants are excelling as well as opportunities for improvement in terms of resilience. This information will provide insight into areas of further investigation and identify potential areas of support needed for the general public to adopt strategies to become more resilient. 1 Lynott, William. “Surviving a Natural (or Man-Made) Disaster: How to Prepare for and Bounce Back? from a Crisis in Your Business | 2018-02-01 | NOLN.” Home Page, NOLN, 1 Feb. 2018, https://www.noln.net/articles/2683-surviving-a-natural-or-man-made-disaster-how-to-prepare-for-and-bounce-back-from-a-crisis-in-your-business.

99 GENERAL AND MISCELLANEOUS↗

Preparacion de Sistemas Solares Fotovoltaicos Contra Tormentas

Through funding provided by the U.S. Department of Energy, the National Renewable Energy Laboratory (NREL) has used subject matter experts to compile a set of checklists to help Puerto Rico and other communities prepare for storms. Renewable energy and distributed energy systems have the potential to provide power to neighborhoods, vulnerable residents, and certain facilities within a community, if those systems are designed to provide power during a grid disruption. The storm-hardening checklists provide storm preparation actions that can increase the chances that solar photovoltaic (PV) systems are available when communities need them most. This resource was translated from English to Spanish for greater acessibility.

hurricane↗

Lista de Verificacion Antes de la Tormenta: Sistemas Solares Fotovoltaicos (PV) Montados en el Techo

Through funding provided by the U.S. Department of Energy, the National Renewable Energy Laboratory (NREL) has used subject matter experts to compile a set of checklists to help Puerto Rico and other communities prepare for storms. Renewable energy and distributed energy systems have the potential to provide power to neighborhoods, vulnerable residents, and certain facilities within a community, if those systems are designed to provide power during a grid disruption. The storm-hardening checklists provide storm preparation actions that can increase the chances that solar photovoltaic (PV) systems are available when communities need them most. This resource was translated from English to Spanish for greater accessibility.

distributed solar PV↗

Lista de Verificacion Antes de la Tormenta: Sistemas Solares Fotovoltaicos (PV) Montados en el Suelo

Through funding provided by the U.S. Department of Energy, the National Renewable Energy Laboratory (NREL) has used subject matter experts to compile a set of checklists to help Puerto Rico and other communities prepare for storms. Renewable energy and distributed energy systems have the potential to provide power to neighborhoods, vulnerable residents, and certain facilities within a community, if those systems are designed to provide power during a grid disruption. The storm-hardening checklists provide storm preparation actions that can increase the chances that solar photovoltaic (PV) systems are available when communities need them most. This resource was translated from English to Spanish for greater acessibility.

distributed solar PV↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Manufacturing of Continuous Core–Shell Hydrated Salt Fibers for Room Temperature Thermal Energy Storage

The encapsulation of salt hydrate phase change materials (PCMs) in uniform microscale bodies has yet been reported in research due in part to the delicate relationship between thermal performance and water-to-salt ratios which are easily altered during manufacturing. Herein, core–shell composite fibers comprised of a salt hydrate PCM core and a poly(acrylonitrile) (PAN) shell are wet spun in a continuous process using a syringe pump and coaxial die. The PCM phase comprises calcium chloride hexahydrate (CaCl 2 ·6H 2 O) with strontium chloride hexahydrate(SrCl 2 ·6H 2 O) (3 wt%) and fumed silica(SiO 2 ) (2 wt%) as additive, a composition that is prepared from homogenous melt at 40 °C. 15 wt% PAN in dimethylsulfoxide solvent is used to prepare the shell-forming polymer gel. PCM and polymer gel injection rates of 10–40 mL h –1 are used to spin coaxial fibers through a coagulation bath, yielding continuous microtubules with diameters in the range of 850–1500 μm. Cyclic testing shows that after 1000 cycles, melting enthalpies incurred only a 3.5% decline from 131.46 to 126.9 J g –1 . In conclusion, success here overcomes several coincidental drawbacks of PCM fiber performance and manufacturing and delivers the first example of scalable roll-to-roll PCM fiber produced by wet spinning for building material applications.

36 MATERIALS SCIENCE↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Sol–Gel‐Based Advanced Porous Silica Materials for Biomedical Applications

Abstract Porous silica‐based materials have burgeoning applications ranging from fillers and additives, to adsorbents, catalysts, and recently therapeutic agents and vaccines in nanomedicine. The preponderance of these materials is made by sol–gel processing wherein soluble silica precursors are reacted to form amorphous networks composed of siloxane bonds. The facile sol–gel approach allows for an unlimited variety of binary tertiary and more complex chemical compositions including organic ligands and networks resulting in so‐called organic–inorganic hybrid materials. Here, a brief review of the recent progress in sol–gel‐derived silica materials prepared as particles, thin films, biosilica/silica bioreplicas (of molecules, cells and organisms), and their related preparation, properties, and bioapplications is provided. First, it highlights the recent achievements of mesoporous silica nanoparticles in biomedical applications, including therapeutic agent delivery, multimodal imaging and theranostics, and bone tissue engineering and repair. Second, the research in evaporation‐induced self‐assembly (EISA)‐based mesostructured silica thin films and cell‐directed EISA in bio/nano interfaces for various bioapplications, such as bioactive coatings, biosensing, and living cell immobilization, has been reviewed. Third, the pioneering work in biomimetic silicification/immobilization of biomolecules and bio‐organisms and silica bioreplication of complex bio‐organisms is summarized. Finally, it is concluded with personal perspectives on the directions of future work on this field.

Lei, Qi↗

3D Ion-Conducting, Scalable, and Mechanically Reinforced Ceramic Film for High Voltage Solid-State Batteries

Concerning the safety aspects of Li+ ion batteries, an epoxy-reinforced thin ceramic film (ERTCF) is prepared by firing and sintering a slurry-casted composite powder film. The ERTCF is composed of Li + ion conduction channels and is made of high amounts of sintered ceramic Li 1+ x Ti 2-x Al x (PO 4 ) 3 (LATP) and epoxy polymer with enhanced mechanical properties for solid-state batteries. The two- and three-dimensional characterizations are conducted not only for showing continuous Li+ ion channels thorough LATP ceramic channels with over 10-4 S cm-1 of ionic conductivity but also to investigate small amounts of epoxy polymer with enhanced mechanical properties. Solid-state Li + ion cells are fabricated using the ERTCF and they show initial charge–discharge capacities of 139/133 mAh g -1 . Furthermore, the scope of the ERTCF is expanded to high-voltage (>8 V) solid-state Li + ion batteries through a bipolar stacked cell design. Hence, it is expected that the present investigation will significantly contribute in the preparation of the next generation reinforced thin ceramic film electrolytes for high-voltage solid-state batteries.

25 ENERGY STORAGE↗

Acceleration of Crystallization Kinetics in Ge‐Sb‐Te‐Based Phase‐Change Materials by Substitution of Ge by Sn

Abstract Thin films of (Ge 1– x Sn x ) 8 Sb 2 Te 11 are prepared to study the impact of Sn‐substitution on properties relevant for application in phase‐change memory, a next‐generation electronic data storage technology. It is expected that substitution decreases the crystallization temperature, but it is not known how the maximum crystallization rate is affected. Ge 8 Sb 2 Te 11 is chosen from the (GeTe) y (Sb 2 Te 3 ) 1– y system of phase‐change materials as a starting point due to its higher crystallization temperature as compared to the common material Ge 2 Sb 2 Te 5 . In situ X‐ray diffraction at 5 K min −1 heating rate is performed to determine the crystallization temperature and the resulting structure. To measure the maximum crystallization rate, femtosecond optical pulses that heat the material repetitively and monitor the resulting increase of optical reflectance are used. Glasses over the entire composition range are prepared using a melt‐quenching process. While at x = 0, 97, subsequent pulses are required for crystallization, one single pulse is enough to achieve the same effect at x = 0.5. The samples are further characterized by optical ellipsometry and calorimetry. The combined electrical and optical contrast and the ability to cycle between states with single femtosecond pulses renders Ge 4 Sn 4 Sb 2 Te 11 promising for photonics applications.

Zalden, Peter↗

Binder-Free Wood Converted Carbon for Enhanced Water Desalination Performance

Here, the design and synthesis of high-performance and economical carbon electrodes play a critical role in developing energy-efficient water desalination technologies. As a sustainable approach, low-cost and abundant biomass materials are promising candidates to prepare porous carbon for capacitive deionization. In this study, binder-free porous carbon sheets are successfully prepared using natural balsa, pine, and basswood by thermal carbonization and treated by chemical activation. The carbon electrode materials converted from balsa and pine exhibit a comparable salt adsorption performance by capacitive deionization due to the extensive surface area, substantial electrical property, and superior hydrophilic performance. The following activation treatment of the balsa-converted carbon further enhances the surface and electrical properties and benefits the desalination performance. The salt adsorption capacity of the activated balsa electrode exhibits 12.45 mg g -1 . Additionally, 19.52 mg g -1 Pb 2+ and 20.06 mg g -1 Cr 3+ heavy metal adsorption capacity is also observed with the activated balsa electrode in 100 mg L -1 PbCl 2 and 50 mg L -1 CrCl 3 , respectively. To the best of authors’ knowledge, this is the highest NaCl adsorption capacity performance reported thus far by using pure wood converted carbon as the electrode, and these promising results indicate that activated balsa is an extraordinary material for water desalination.

36 MATERIALS SCIENCE↗