Tables of energy losses and ranges of electrons and positrons
Tables of energy losses and ranges of electrons and positrons
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Tables of energy losses and ranges of electrons and positrons
Positron s-wave elastic scattering by atomic hydrogen below inelastic threshold analyzed, using Dalgarno-Lynn second order adiabatic potential
Minimum principle for single channel scattering applied to S-wave elastic-scattering phase shift of positrons by atomic hydrogen
Ratio of electron to positrons in primary cosmic radiation investigated by balloon-borne instrument over Ft. Churchill
Theory of low energy positron helium scattering below positronium threshold - adiabatic method applied
Balloon flight data on cosmic ray electron- positron ratio from 100 MeV to 3 BeV
Positron scattering by atomic hydrogen for various incident energies
Intensity and spectra of cosmic ray electrons and positrons in determining mean confinement time, density and solar modulation
Modified adiabatic scattering function applied to positron annihilation in helium
Modified adiabatic scattering function applied to positron annihilation in helium
Resonances in proton hydrogen and positron hydrogen scattering predicted at energies just below excitation thresholds
We present a novel concept of a low-energy e{sup +} source with projected intensity on the order of 10{sup 10} slow e{sup +}/s. The key components of this concept are a continuous wave e{sup -} beam, a rotating positron-production target, a synchronized raster/anti-raster, a transport channel, and extraction of e{sup +} into a field-free area through a magnetic plug for moderation in a cryogenic solid. Components were designed in the framework of GEANT4-based (G4beamline) Monte Carlo simulation and TOSCA magnetic field calculation codes. Experimental data to demonstrate the effectiveness of the magnetic plug is presented.
This paper reviews the experiments on the laser produced electron-positron jets using large laser facilities worldwide. The goal of the experiments was to optimize the parameter of the pair jets for their potential applications in laboratory-astrophysical experiment. Results on tuning the pair jet’s energy, number, emittance and magnetic collimation will be presented.
Purpose: To evaluate how changes in tumor hypoxia, according to serial fluorine-18-labeled fluoro-misonidazole ({sup 18}F-FMISO) positron emission tomography (PET) imaging, affect the efficacy of intensity-modulated radiotherapy (IMRT) dose painting. Methods and Materials: Seven patients with head and neck cancers were imaged twice with FMISO PET, separated by 3 days, before radiotherapy. Intensity-modulated radiotherapy plans were designed, on the basis of the first FMISO scan, to deliver a boost dose of 14 Gy to the hypoxic volume, in addition to the 70-Gy prescription dose. The same plans were then applied to hypoxic volumes from the second FMISO scan, and the efficacy of dose painting evaluated by assessing coverage of the hypoxic volumes using D{sub max}, D{sub min}, D{sub mean}, D{sub 95}, and equivalent uniform dose (EUD). Results: Similar hypoxic volumes were observed in the serial scans for 3 patients but dissimilar ones for the other 4. There was reduced coverage of hypoxic volumes of the second FMISO scan relative to that of the first scan (e.g., the average EUD decreased from 87 Gy to 80 Gy). The decrease was dependent on the similarity of the hypoxic volumes of the two scans (e.g., the average EUD decrease was approximately 4 Gy for patients with similar hypoxic volumes and approximately 12 Gy for patients with dissimilar ones). Conclusions: The changes in spatial distribution of tumor hypoxia, as detected in serial FMISO PET imaging, compromised the coverage of hypoxic tumor volumes achievable by dose-painting IMRT. However, dose painting always increased the EUD of the hypoxic volumes.
Purpose: To determine the accuracy and prognostic significance of post-treatment [{sup 18}F]-fluorodeoxyglucose positron emission tomography (FDG-PET) in head-and-neck squamous cell carcinoma after radiotherapy (RT). Methods and Materials: This was a retrospective study of 188 patients with head-and-neck squamous cell carcinoma who had undergone FDG-PET within 12 months after completing RT. All living patients had {>=}1 year of follow-up after FDG-PET. All patients had undergone intensity-modulated RT, 128 with definitive and 60 with postoperative intensity-modulated RT. Results: For all patients, the median follow-up after RT completion was 32.6 months and after FDG-PET was 29.2 months. For the neck, 171 patients had negative FDG-PET findings. Of these results, two were falsely negative. Seventeen patients had positive FDG-PET findings, of which 12 were true-positive findings. The sensitivity, specificity, positive predictive value, and negative predictive value for FDG-PET in the assessment of the treatment response in the neck was 86%, 97%, 71%, and 99%, respectively. For the primary site, 151 patients had negative FDG-PET findings, of which two were falsely negative. Thirty-seven patients had positive FDG-PET findings, of which 12 were true-positive findings. The sensitivity, specificity, positive predictive value, and negative predictive value for FDG-PET in the assessment of the treatment response in the primary site was 86%, 86%, 32.4%, and 98.7%, respectively. Patients with positive post-RT PET findings had significantly worse 3-year overall survival and disease-free survival. Conclusion: The results of our study have shown that the findings of post-RT FDG-PET have a high negative predictive value and are a significant prognostic factor. It can provide guidance for the management of head-and-neck cancer after definitive treatment.
Silicon carbide (SiC) has been widely applied or considered in nuclear systems as fuel and structural materials since 1960's, given its high-temperature stability, chemical inertness, and exceptional irradiation resistance. Chemically vapor deposited (CVD) SiC has been considered as the pressure vessel materials for the TRISO fuel particles used in high temperature gas-cooled reactors or novel accident tolerant fuel concepts for light water reactors. The use of SiC/SiC composites as primary structural materials has also been proposed in fusion reactors. Driven by the need to enlarge the safety margins of nuclear reactors in accident scenarios, R and D of accident-tolerant fuel has become an important topic in the nuclear engineering and materials community. A continuous fiber SiC/SiC composite is under consideration for Zr alloy cladding replacement. Microstructural development and mechanical property change in SiC subject to neutron and ion irradiation have been studied extensively and understood well. However, the information of small vacancy cluster (i.e., those invisible in TEM) evolution in SiC exposed to neutron irradiation is still lacking, and such small clusters is suspected to play an important role in swelling, radiation creep, and thermal conductivity degradation. In this study, positron annihilation spectroscopy is used to characterize the vacancy defects in 3C-SiC exposed to various neutron irradiation conditions to capture the dependence of temperature and irradiation dose. The obtained vacancy cluster distribution is then linked to the measured swelling behavior to provide insight into the relationship between microstructure and physical property of SiC. (authors)
The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.
Clouds of electrons in the vacuum chambers of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electron clouds over substantial lengths of the beam pipe. We applied a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave which is independently excited and transmitted over a straight section of the accelerator. The modulation in the wave transmission which appear to increase in depth when the clearing solenoids are switched off, seem to be directly correlated to the electron cloud density in the section. Furthermore, we expect a larger phase shift of a wave transmitted through magnetic dipole field regions if the transmitted wave couples with the gyration motion of the electrons. We have used this technique to measure the average electron cloud density (ECD) specifically for the first time in magnetic field regions of a new 4-dipole chicane in the positron ring of the PEP-II collider at SLAC. In this paper we present and discuss the measurements taken in the Low Energy Ring (LER) between 2006 and 2008.