Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Metal Flow During Friction Stir Welding

The flow of metal during Friction Stir Welding is clarified using a faying surface tracer and a nib frozen in place during welding. It is shown that material is transported by two processes. The first is a wiping of material from the advancing front side of the nib onto a plug of material that rotates and advances with the nib. The material undergoes a helical motion within the plug that both rotates and advances with the plug and descends in the wash of the threads on the nib and rises on the outer part of the plug. After one or more rotations, this material is sloughed off the plug in its wake, primarily on the advancing side. The second process is an entrainment of material from the front retreating side of the nib that fills in between the sloughed off pieces from the advancing side. These two processes produce material with different mechanical properties and the strength of a weld should depend on the relative importance of the processes.

Guerra, M.↗

Material Flow During Friction Stir Welds

The flow of metal during Friction Stir Welding is clarified using a faying surface tracer and a nib frozen in place during welding. It is shown that material is transported in two distinct streams or currents. One stream is a wiping of material from the advancing front side of the nib onto a plug of material that rotates and advances with the nib. The material undergoes a helical motion within the plug that both rotates and advances with the plug and descends in the wash of the threads on the nib and rises on the outer part of the plug. After one or more rotations, this material is sloughed off the plug in the wake of the tool primarily on the advancing side. The second stream of material is an entrainment of material from the retreating side of the nib that fills in between the sloughed off pieces from the advancing side. These two processes produce material with different mechanical properties and the strength of a weld should depend on the relative importance of the processes.

Guerra, M.↗

Adaptation of primate vestibuloocular reflex to altered peripheral vestibular inputs. I. Frequency-specific recovery of horizontal VOR after inactivation of the lateral semicircular canals

1. The adaptive plasticity of the vestibuloocular reflex (VOR) following a selective lesion of the peripheral vestibular organs was investigated in rhesus monkeys whose lateral semicircular canals were inactivated by plugging of the canal lumen in both ears. Gain and phase of horizontal, vertical, and torsional slow-phase eye velocity were determined from three-dimensional eye movement recordings obtained acutely after the plugging operation, as well as in regular intervals up to 10 mo later. 2. Acutely after plugging, horizontal VOR was minimal during yaw rotation with gains of < 0.1 at all frequencies. Horizontal VOR gain gradually increased over time, reaching gains of 0.4-0.5 for yaw oscillations at 1.1 Hz approximately 5 mo after lateral canal inactivation. This response recovery was strongly frequency dependent: horizontal VOR gains were largest at the highest frequency tested and progressively decreased for lower frequencies. Below approximately 0.1 Hz, no consistent horizontal VOR could be elicited even 10 mo after plugging. 3. The frequency-dependent changes in gain paralleled changes in horizontal VOR phase. Below approximately 0.1-0.05 Hz large phase leads were present, similarly as in semicircular canal primary afferents. Smaller phase leads were also present at higher frequencies, particularly at 1.1 Hz (the highest frequency tested). 4. Consistent with the afferent-like dynamics of the adapted horizontal VOR, per- and postrotatory horizontal responses to constant-velocity yaw rotations were short lasting. Time constants of the slow-phase eye velocity envelope of the horizontal postrotatory nystagmus were approximately 2 s. Nonetheless, a consistent horizontal optokinetic afternystagmus was evoked in plugged animals. 5. A torsional component that was absent in intact animals was consistently present during yaw rotation acutely after lateral canal inactivation and remained approximately constant thereafter. The frequency response characteristics of this torsional component resembled those of the adapted horizontal slow-phase responses: gain decreased and large phase leads were introduced at frequencies below approximately 0.05-0.1 Hz. Torsional responses elicited by roll oscillations in supine position, on the other hand, were indistinguishable in their dynamics from intact animals. No consistent vertical nystagmus was elicited during yaw rotation. 6. Our results show that there is a slow, frequency-specific recovery of horizontal VOR after selective inactivation of the lateral semicircular canals. Both the spatial organization and the dynamic properties of the adapted VOR responses are distinctly different from responses in intact animals, suggesting complex changes in the underlying vestibuloocular circuitry.

NASA Program Space Physiology and Countermeasures↗

Quick actuating closure

A quick actuating closure for a pressure vessel 80 in which a wedge ring 30 with a conical outer surface 31 is moved forward to force shear blocks 40, with conical inner surfaces 41, radially outward to lock an end closure plug 70 within an opening 81 in the pressure vessel 80. A seal ring 60 and a preload ramp 50 sit between the shear blocks 40 and the end closure plug 70 to provide a backup sealing capability. Conical surfaces 44 and 55 of the preload ramp 50 and the shear blocks 40 interact to force the seal ring 60 into shoulders 73 and 85 in the end closure plug 70 and opening 81 to form a tight seal. The end closure plug 70 is unlocked by moving the wedge ring 30 rearward, which causes T-bars 32 of the wedge ring 30 riding within T -slots 42 of the shear blocks 40 to force them radially inward. The end closure plug 70 is then removed, allowing access to the interior of the pressure vessel 80.

White, III, Dorsey E.↗

Device for Automated Cutting and Transfer of Plant Shoots

A device that enables the automated cutting and transfer of plant shoots is undergoing development for use in the propagation of plants in a nursery or laboratory. At present, it is standard practice for a human technician to use a knife and forceps to cut, separate, and grasp a plant shoot. The great advantage offered by the present device is that its design and operation are simpler than would be those of a device based on the manual cutting/separation/grasping procedure. [The present device should not be confused with a prior device developed for partly the same purpose and described in Compliant Gripper for a Robotic Manipulator (NPO-21104), NASA Tech Briefs, Vol. 27, No. 3 (March 2003), page 59.]. The device (see figure) includes a circular tube sharpened at its open (lower) end and mounted on a robotic manipulator at its closed (upper) end. The robotic manipulator simply pushes the sharpened open end of the tube down onto a bed of plants and rotates a few degrees clockwise then counterclockwise about the vertical axis, causing the tube to cut a cylindrical plug of plant material. Exploiting the natural friction between the tube and plug, the tube retains the plug, without need for a gripping mechanism and control. The robotic manipulator then retracts the tube, translates it to a new location over a plant-growth tray, and inserts the tube part way into the growth medium at this location in the tray. A short burst of compressed air is admitted to the upper end of the tube to eject the plug of plant material and drive it into the growth medium. A prototype has been tested and verified to function substantially as intended. It is projected that in the fully developed robotic plant-propagation system, the robot control system would include a machine- vision subsystem that would automatically guide the robotic manipulator in choosing the positions from which to cut plugs of plant material. Planned further development efforts also include more testing and refinement of the design and operation described above.

Cipra, Raymond↗

Surface sampling concentration and reaction probe

A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wireless Power Transfer

Wireless Power Transfer is an innovative approach using magnetic resonance coupling of air core transformers designed for today's growing plug-in electric vehicle market. This technology can provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions. Plug-in Electric Vehicles (PEV) are burdened by the need for cable and plug charger, galvanic isolation of the on-board electronics, bulk and cost of this charger and the large energy storage system (ESS) packs needed. With a system where you have to physically plug in there are a number of occasions where the owner could very well forget to charge the vehicle. For stationary applications (like charging of a PHEV at home), ORNL's innovative wireless power transfer technology adds a convenience factor compared to actually plugging in which will mean that the vehicle will have a full charge every morning. Electric vehicle charging must be safe, compact and efficient in order to be convenient for customers. By reconfiguring the transformer and altering the resonance frequency, energy is transferred to the battery with lower energy losses and with fewer demands on the primary circuit by the rest of the transformer system. The ORNL discovery shows that sufficient power for the battery can be transferred from the primary to secondary circuits without significant energy losses if the operating frequency is set at 50% to 95% of the resonance frequency of the circuit. The electrical power is then transmitted to the chargeable battery, which is electrically coupled to the secondary circuit through the air core transformer. Some advantages include: Reduced energy losses during transfer of energy to the battery; A charge potential that is relatively unaffected by up to 25% misalignment of vehicle; and Other receiving components draw less power from the primary circuit. These advantages allow wireless power technology applications to expand at the workplace and beyond as the demand for EV rises. For vehicles that operate over a fixed route such as busses and shuttle vehicles, Wireless Power Transfer (WPT) means that a smaller battery pack can be used. In the traditional system, the battery pack is designed to accommodate the needs of the entire route or shift. With WPT the battery can be downsized because it can be charged when the vehicle stops on its route (a rental car shuttle bus, for example, can charge when it waits in the terminal and again when it waits at the rental car place. Thus the battery only needs enough charge to get to the next stop. This decrease in battery size means significant cost savings to electrify the vehicle. This technology enables efficient "opportunity charging stations" for predefined routes and planned stops reducing down time. Charging can occur in minutes. This improvement also eliminates the harmful emissions that occur in garages while buses are at idle during charging. In larger cities, dynamic charging offers an even greater impact utilizing existing infrastructure. As vehicles travel along busy freeways and interstate systems, wireless charging can occur while the vehicle is in motion. With this technology a vehicle essentially has unlimited electric range while using a relatively small battery pack. In-motion charging stations use vehicle sensors to alert the driver. Traveling at normal speeds, sensors establish in-motion charging. WPT transmit pads sequentially energize to the negotiated power level based on vehicle speed and its requested charging energy. Lower power when vehicle speed is slow and much higher power for faster moving vehicles. Vehicle to Infrastructure communications (V2I) coordinates WPT charging level according to on-board battery pack state-of-charge. V2I activates the roadway transmit pads placing them in standby mode and negotiates charging fee based on prevailing grid rate and vehicle energy demand. Dynamic charging would allow electricity to supply a very large fraction of the energy for the transportation sector and reduce greatly petroleum consumption. Previously worrisome traffic delays now provide longer periods of charge while passing over in-motion chargers. Inclement weather such as rain and snow do not affect the charging capability. At ORNL, we are working to develop the robust nature of wireless power technology to provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Surface sampling concentration and reaction probe with controller to adjust sampling position

A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards improved mesh-designing techniques of spark-ignition engines in the framework of spectral element methods

In the current paper we present an advanced meshing technique to perform high-fidelity numerical simulations in spark ignition (SI) engines. The design of the mesh is critical towards generating physically consistent, high fidelity data especially in regions of complex boundaries inside the cylinder, e.g., near the spark plugs. This is primarily due to the mesh deformation caused by the motion of the valve near the plug and also finer mesh sizes in the spark plug region. In the current work, we demonstrate the use of an overlapping grid (overset) methodology to design the mesh in the spark-plug region in a 2D SI engine-like geometry for a high-order simulation, based on the spectral element method (SEM). The data in the overlapping region is exchanged between the spark-plug geometry and the geometry containing rest of the objects like the piston, cylinder head, valve etc., using a high order spectral interpolation technique. The numerical simulations have been further compared against the standard, single (non-overset) grid, meshing technique for the whole 2D domain. The results further illustrate the capability of overlapping grid methodology in handling mesh deformation compared to the standard grid case and also the ability to capture the flow dynamics with a similar level of fidelity as the standard one

overlapping grids↗

Development of joining technology using local heating for SiC fuel cladding

Silicon carbide (SiC) is an attractive material for an accident-tolerant fuel in light water reactors because of its lower hydrogen-generation rate and lower heat of reaction than conventional Zircaloy. On the other hand, practical application of SiC fuel cladding faces a lot of critical issues, one of which is end-plug joining. The objective of this study is to clarify the feasibility of end-plug joining by silicon brazing using local heating by evaluating the shear strength of joint specimens and producing a circumferential joint experimentally. Silicon is thought to be a compatible joining material with SiC because as well as being a constituent of SiC, its thermal-expansion coefficient is close to that of SiC. Local heating using processes such as laser irradiation and a resistance-heating element needs to be applied for end-plug joining. Brazing is expected to seal a cladding with an end plug by using brief heating without a strong compression force. Shear strength was evaluated using specimens with silicon-brazing joints processed using laser irradiation. The joint sections without defects showed shear strengths higher than or equal to 59 MPa at temperatures from normal room temperature to 1473 K. The average shear strength of the joint (99 MPa) is comparable to that of a diffusion-bonding joint using titanium or molybdenum foil. A tube and a plug were circumferentially joined with silicon brazing using laser irradiation or a graphite heating element. A defocused laser beam was effective for joining without cracking during laser irradiation. Although local heating using a resistance-heating element can more easily control the temperature of the joint, it took longer processing time than that using laser irradiation due to limited temperature-increase rate in order to avoid thermal shock damage. (authors)

36 MATERIALS SCIENCE↗

Design of Removable Shield Modules for Nuclear Plant Applications Using Monte Carlo Modeling - 16264

A new modular shielding system has been designed and developed for nuclear plant applications as a replacement for traditional concrete blocks and plugs. The shield comprises interlocking modules that are custom designed using CAD and Monte Carlo modelling methods. The key benefit of these new modules is that they can be quickly removed and re-installed to allow temporary access to high radiation environments e.g. for maintenance and repair of plant equipment at nuclear power plants or waste handling facilities. The traditional method for construction of these removable concrete blocks and plugs was to cast them in place. Within the aging fleet of commercial reactors, some plants are experiencing concrete degradation of these shield blocks and plugs as well as failure of lifting points. Additionally, the existing plugs are difficult to remove and re-install. The new modular system comprises a rigid steel enclosure filled with lead that can be installed in a fraction of the normal time. This approach can accelerate outage times leading to reduced dose uptake to operators and provide significant long term cost savings. Use of Monte Carlo methods enables the shielding modules to be designed efficiently for neutron and gamma ray attenuation with the minimum necessary thickness of lead and steel. Furthermore, the modelling ensures the design is not compromised by streaming pathways, for example at the overlaps between modules or through internal structural components. Shielding modules were supplied to the Brunswick Nuclear Power station (BNP), operated by Duke Energy, located in southeast United States. These modules have been installed to replace concrete shield plugs that are located on the roof above a Feed Water Heaters (FWH) bay. While specific in application, this project demonstrates that the shield module design concept could be expanded to address vertical block walls routinely found in personnel and equipment access hatches. This approach is applicable to a wide variety of new and existing nuclear facilities and will lead to improved safety and reduced lifetime costs all the way through to future decommissioning and dismantling operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Origins of wear-induced tungsten corrosion defects in semiconductor manufacturing during tungsten chemical mechanical polishing

During chemical mechanical polishing (CMP) process optimization, a unique corrosion defect was identified in the tungsten (W) contact plugs, which were investigated to develop practical solutions to improve CMP mass productivity. The corrosion defect occurred in the absence of external incident energy and was observed to occur only at the W plugs connected to the P + /n-well close to the wafer edge. To examine the root cause of the corrosion, a series of experiments was carried out at each W CMP step, using in-line defect inspection. Additional experiments were conducted using on-line inductively coupled plasma mass spectrometry (ICP-MS) to understand pH- and potential-dependent electrochemical dissolution behaviors of W. Experimentally, W corrosion was confirmed to be exacerbated if the surface oxide of the W plugs is removed by the deionized water (DIW) rinsing step under wafer pressurization, then exposed to DIW and alkaline cleaning solution. Although the DIW rinsing step is commonly performed to clean polishing pads right after the main polishing, a small amount of applied pressure (0.5 psi) without slurry supply can lead to corrosion defects. Finally, this wear-induced corrosion of the W plugs can be prevented by removing the applied pressure during the post DIW rinsing step of W CMP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PHEV Distribution Grid Integration and Smart Systems Testing: Cooperative Research and Development Final Report

To continue NREL's mission, which includes preparing technologies and markets with "speed and scale," NREL researchers will collaborate with Toyota on plug-in electric vehicle technology. Toyota will provide a collection of plug-in hybrid electric vehicles ("PHEVs" [and ultimately including PEVs], collectively, the "Vehicles") to conduct infrastructure interaction testing at NREL facilities. NREL will use available resources in the Vehicle Testing and Integration Facility (VTIF), its staff parking garage with numerous commercial Electric Vehicle Supply Equipment ("EVSEs"), and its Energy Systems Integration Facility (ESIF) to safely execute research experiments that highlight potential distribution system power quality challenges related to plug-in electric vehicles. The expected outcome of this project is a better understanding of the correlation of individual vehicle power quality attributes to a system of vehicles on a distribution network. The data collected and the simulations conducted will be used to guide future experiments and project development that aid in the deployment of plug-in electric vehicles ("PEV").

24 POWER TRANSMISSION AND DISTRIBUTION↗

SODIUM ALUMINOSILICATE FOULING AND CLEANING OF DECONTAMINATED SALT SOLUTION COALESCERS

During initial non-radioactive operations at the Modular Caustic Side Solvent Extraction Unit (MCU), the pressure drop across the decontaminated salt solution coalescer reached {approx}10 psi while processing {approx}1250 gallons of salt solution, indicating possible fouling or plugging of the coalescer. An analysis of the feed solution and the 'plugged coalescer' concluded that the plugging was due to sodium aluminosilicate solids. MCU personnel requested Savannah River National Laboratory (SRNL) to investigate the formation of the sodium aluminosilicate solids (NAS) and the impact of the solids on the decontaminated salt solution coalescer. Researchers performed developmental testing of the cleaning protocols with a bench-scale coalescer container 1-inch long segments of a new coalescer element fouled using simulant solution. In addition, the authors obtained a 'plugged' Decontaminated Salt Solution coalescer from non-radioactive testing in the MCU and cleaned it according to the proposed cleaning procedure. Conclusions from this testing include the following: (1) Testing with the bench-scale coalescer showed an increase in pressure drop from solid particles, but the increase was not as large as observed at MCU. (2) Cleaning the bench-scale coalescer with nitric acid reduced the pressure drop and removed a large amount of solid particles (11 g of bayerite if all aluminum is present in that form or 23 g of sodium aluminosilicate if all silicon is present in that form). (3) Based on analysis of the cleaning solutions from bench-scale test, the 'dirt capacity' of a 40 inch coalescer for the NAS solids tested is calculated as 450-950 grams. (4) Cleaning the full-scale coalescer with nitric acid reduced the pressure drop and removed a large amount of solid particles (60 g of aluminum and 5 g of silicon). (5) Piping holdup in the full-scale coalescer system caused the pH to differ from the target value. Comparable hold-up in the facility could lead to less effective cleaning and precipitation of bayerite solid particles. (6) Based on analysis of the cleaning solutions from the full-scale test, the 'dirt capacity' of a 40 inch coalescer for these NAS solids was calculated to be 40-170 grams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Qualitative Investigation of Deposition Velocities of a Non-Newtonian Slurry in Complex Pipeline Geometries

The External Flowsheet Review Team (EFRT) has identified the issues relating to the Waste Treatment and Immobilization Plant (WTP) pipe plugging. Per the review’s executive summary, “Piping that transports slurries will plug unless it is properly designed to minimize this risk. This design approach has not been followed consistently, which will lead to frequent shutdowns due to line plugging.” To evaluate the potential for plugging, testing was performed to determine critical velocities for the complex WTP piping layout. Critical velocity is defined as the point at which a moving bed of particles begins to form on the pipe bottom during slurry-transport operations. Pressure drops across the fittings of the test pipeline were measured with differential pressure transducers, from which the critical velocities were determined. A WTP prototype flush system was installed and tested upon the completion of the pressure-drop measurements. We also provide the data for the overflow relief system represented by a WTP complex piping geometry with a non-Newtonian slurry. A waste simulant composed of alumina (nominally 50 μm in diameter) suspended in a kaolin clay slurry was used for this testing. The target composition of the simulant was 10 vol% alumina in a suspending medium with a yield stress of 3 Pa. No publications or reports are available to confirm the critical velocities for the complex geometry evaluated in this testing; therefore, for this assessment, the results were compared to those reported by Poloski et al. (2008) for which testing was performed for a straight horizontal pipe. The results of the flush test are compared to the WTP design guide 24590-WTP-GPG-M-0058, Rev. 0 (Hall 2006) in an effort to confirm flushing-velocity requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Particle-based modelling of axisymmetric tandem mirror devices

In this work, we describe the use of a 1D-2V quasi-neutral hybrid electrostatic PIC with Monte-Carlo Coulomb collisions and non-uniform magnetic field to model the parallel transport and confinement in an axisymmetric tandem mirror device. End-plugs, based on simple-mirrors, are positioned at each end of the device and fueled with neutral beams (25 and 100 keV) to produce a sloshing ion population and increase the density of the end-plugs relative to the central cell. Results show the formation of a potential difference barrier between the central cell and the end-plugs. This potential confines a large fraction of the low energy thermal ions in the central cell which would otherwise be lost in a simple mirror, demonstrating the advantage of the beam-driven tandem mirror configuration relative to simple mirrors. In addition, we explore the effect of end-plug electron temperature on the confinement time of the device and compare it with theoretical estimates. Finally, we discuss the limitations of the code in its present form and describe the next logical steps to improve its predictive capability such as a fully nonlinear Fokker–Planck collision operator, multiply nested flux surface solutions and modeling the exhaust region up to the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupling and matching study of the ICRF antenna for W7-X

A tight antenna plug consisting in a pair of straps with strong pre-matching covers the first selected frequency band (25-38MHz) for W7-X and provides the toroidal phasings for heating, current drive and wall conditioning. Another plug-in with two short strap triplets is devoted for operation around 76MHz. The antenna coupling to a reference plasma profile is first analyzed by means of the coupling code ANTITER II. It shows the radiation power spectra for the different phasing cases and indicates the problem of the edge power deposition through the Alfven resonance occurring when the operating frequency is lower than the majority cyclotron frequency. Matrices provided by the TOPICA code are used for the matching-decoupling study of the first antenna plug. The large mutual coupling between the 2 straps is counterbalanced by the use of a decoupler. Finally the tunable 5-port junction used to feed in parallel each triplet of the second plug-in is analyzed by means of MWS simulation together with its decoupling-matching system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Catalyst synthesis and evaluation using an integrated atomic layer deposition synthesis–catalysis testing tool

An integrated atomic layer deposition-catalysis (I-ALD-CAT) tool was developed, combining an ALD manifold with a plug-flow reactor system for the synthesis of supported catalytic materials by ALD and immediate evaluation of catalyst reactivity using gas-phase probe reactions. The I-ALD-CAT system can deliver gaseous reagents comprised of 12 different metal ALD precursors, 4 oxidizing or reducing agents, and 4 catalytic reaction feeds to either of the two plug-flow reactors. The system can employ reactor pressures and temperatures in the range of 10 -3 to 1 bar and 300–1000 K, respectively. Furthermore, the instrument is also equipped with a gas chromatograph and a mass spectrometer unit for the detection and quantification of volatile species from ALD and catalytic reactions. In this report, we demonstrate the use of the I-ALD-CAT tool for the ALD of platinum active sites and Al 2 O 3 overcoats, and evaluation of catalyst propylene hydrogenation activity.

47 OTHER INSTRUMENTATION↗