Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Characterization of carrier behavior in photonically excited 6H silicon carbide exhibiting fast, high voltage, bulk transconductance properties

Abstract Unabated, worldwide trends in CO 2 production project growth to > 43-BMT per year over the next two decades. Efficient power electronics are crucial to fully realizing the CO 2 mitigating benefits of a worldwide smart grid (~ 18% reduction for the United States alone). Even state-of-the-art SiC high voltage junction devices are inefficient because of slow transition times (~ 0.5-μs) and limited switching rates at high voltage (~ 20-kHz at ≥ 15-kV) resulting from the intrinsically limited charge carrier drift speed (< 2 × 10 7 -cm-s −1 ). Slow transition times and limited switch rates waste energy through transition loss and hysteresis loss in external magnetic components. Bulk conduction devices, where carriers are generated and controlled nearly simultaneously throughout the device volume, minimize this loss. Such devices are possible using below bandgap excitation of semi-insulating (SI) SiC single crystals. We explored carrier dynamics with a 75-fs single wavelength pump/supercontinuum probe and a modified transient spectroscopy technique and also demonstrated a new class of efficient, high-speed, high-gain, bi-directional, optically-controlled transistor-like power device. At a performance level six times that of existing devices, for the first time we demonstrated prototype operation at multi-10s of kW and 20-kV, 125-kHz in a bulk conduction transistor-like device using direct photon-carrier excitation with below bandgap light.

36 MATERIALS SCIENCE↗

Noise reduction in X-ray photon correlation spectroscopy with convolutional neural networks encoder–decoder models

Abstract Like other experimental techniques, X-ray photon correlation spectroscopy is subject to various kinds of noise. Random and correlated fluctuations and heterogeneities can be present in a two-time correlation function and obscure the information about the intrinsic dynamics of a sample. Simultaneously addressing the disparate origins of noise in the experimental data is challenging. We propose a computational approach for improving the signal-to-noise ratio in two-time correlation functions that is based on convolutional neural network encoder–decoder (CNN-ED) models. Such models extract features from an image via convolutional layers, project them to a low dimensional space and then reconstruct a clean image from this reduced representation via transposed convolutional layers. Not only are ED models a general tool for random noise removal, but their application to low signal-to-noise data can enhance the data’s quantitative usage since they are able to learn the functional form of the signal. We demonstrate that the CNN-ED models trained on real-world experimental data help to effectively extract equilibrium dynamics’ parameters from two-time correlation functions, containing statistical noise and dynamic heterogeneities. Strategies for optimizing the models’ performance and their applicability limits are discussed.

36 MATERIALS SCIENCE↗

Photon acceleration of high-intensity vector vortex beams into the extreme ultraviolet

Extreme ultraviolet (XUV) light sources allow for the probing of bound electron dynamics on attosecond scales, interrogation of high-energy-density matter, and access to novel regimes of strong-field quantum electrodynamics. Despite the importance of these applications, coherent XUV sources remain relatively rare, and those that do exist are limited in their peak intensity and spatio-polarization structure. Here, we demonstrate that photon acceleration of an optical vector vortex pulse in the moving density gradient of an electron beam–driven plasma wave can produce a high-intensity, tunable-wavelength XUV pulse with the same vector vortex structure as the original pulse. Quasi-3D, boosted-frame particlein- cell simulations show the transition of optical vector vortex pulses with 800-nm wavelengths and intensities below 10 18 W/cm 2 to XUV vector vortex pulses with 36-nm wavelengths and intensities exceeding 10 20 W/cm 2 over a distance of 1.2 cm. The XUV pulses have sub-femtosecond durations and nearly flat phase fronts. The production of such high-quality, high-intensity XUV vector vortex pulses could expand the utility of XUV light as a diagnostic and driver of novel light–matter interactions.

43 PARTICLE ACCELERATORS↗

Photonic Doppler velocimetry of ohmically exploded aluminum surfaces

Photonic Doppler Velocimetry (PDV) was used to measure the exploding surface of coated metal driven by lineal current density increasing at 3 × 10 15 A/m/s. Here, aluminum-6061 rods were coated with three thicknesses (5, 17, and 41 μm) of Parylene-N and driven to 850 kA in approximately 100 ns, with the metal thicker than the skin depth. According to PDV, the metal surface melts at 85 ± 13 T and expands with a constant acceleration. Then, at surface magnetic field 140-180 T, the metal acceleration begins to increase in time. Later, plasma forms on, and is correlated with PDV signal loss from, uncoated aluminum rods, 5-μm-coated rods, and 17-μm-coated rods, while no evidence suggests plasma forms on 41-μm-coated metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme measurements with Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based diagnostic for the extreme conditions created by high-speed impact, explosive detonation, electrical pulsed power, and intense laser ablation. PDV is a conceptually simple application of the optical Doppler effect, but measurements above 1 km/s only became practical at the beginning of the twenty-first century. In this work, I discuss the evolution of PDV, its operational details, practical analysis, and outstanding challenges.

47 OTHER INSTRUMENTATION↗

Two-photon polymerization printed lattices as support structures in multi-shell ICF targets: Platform development and initial assessment

Recent interest in fielding direct drive multi-shell targets on the NIF [K. Molvig et al., Phys. Rev. Lett. 116, 255003 (2016) and S. X. Hu et al., Phys. Rev. E 100, 063204 (2019)] has highlighted the need for a low density structure to support the inner shell(s) and to avoid energy loss in the acceleration and collision process. We have developed a two-shell platform to evaluate the use of low density two-photon polymerization (2PP) printed lattices as a support structure between the shells. Here, 2PP structures are an attractive option because they can be produced at densities as low as 5 mg/cc, which is ideal for multi-shell targets, and their 3D structure can be tailored to the user's needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a large area photon detector for rare event search applications

We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm 2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature T c = 41.5 mK to measure a thermal phonons released from interactions with photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of photon statistics and multimode field correlations by Raman processes

Glauber’s g (2) -function provides a common measure of quantum field statistics through two-photon coincidence counting in Hanbury Brown–Twiss measurements. Here, we propose to use nonlinear optical signals as a tool for the characterization of quantum light. In particular, we show that Raman measurements provide an alternative direct probe for a different component of the four-point correlation function underlying the g (2) -function. We illustrate this capacity for a specific quantum state obtained from a frequency conversion process. Our work points out how the analysis of controlled optical nonlinear processes can provide an alternative window toward the analysis of quantum light sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-photon absorption laser induced fluorescence measurements of absolute neutral deuterium density, temperature, and bulk flow in Proto-MPEX

Neutral particle control is critical for fusion fueling and confinement. Neutral diagnostics for fusion-relevant plasmas are commonly restricted to line-integrated or ex situ methods. A non-perturbative, two-photon absorption laser induced fluorescence (TALIF) diagnostic is implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to probe neutral atomic deuterium in a fusion-relevant plasma at 1 cm intervals along the radius of the vacuum vessel. The diagnostic is situated ~20 m from the vacuum vessel, and a signal is collected along the laser injection axis, requiring only one line-of-sight. TALIF measurements are absolutely calibrated using xenon and krypton. Absolute atomic densities derived from xenon calibration are compared to absolute atomic densities derived from krypton calibration. In this work, preliminary measurements of absolute atomic deuterium density, temperature, and local bulk flow dependence on radial location and input power in Proto-MPEX are presented. Neutral atomic deuterium velocity distribution functions are measured throughout a one-second plasma pulse with a time resolution of 250 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CO 2 laser heating system for in situ radial x-ray absorption at 16-BM-D at the Advanced Photon Source

Here we present a portable CO 2 laser heating system for in situ x-ray absorption spectroscopy (XAS) studies at 16-BM-D (High Pressure Collaborative Access Team, Advanced Photon Source, Argonne National Laboratory). Back scattering optical measurements are made possible by the implementation of a Ge beamsplitter. Optical pyrometry is conducted in the near-infrared, and our temperature measurements are free of chromatic aberration due to the implementation of the peak-scaling method and mode scrambling of the input signal. Laser power stabilization is established using electronic feedback, providing a steady power over second timescales - crucial for longer XAS collections. Examples of in situ high pressure–temperature extended x-ray absorption fine structure measurements of ZrO 2 are presented to demonstrate this new capability.

36 MATERIALS SCIENCE↗

Three-step colloidal gelation revealed by time-resolved x-ray photon correlation spectroscopy

The gelation of PEGylated gold nanoparticles dispersed in a glycerol–water mixture is probed in situ by x-ray photon correlation spectroscopy. Following the evolution of structure and dynamics over 10 4 s, a three-step gelation process is found. First, a simultaneous increase of the Ornstein–Zernike length ξ and slowdown of dynamics is characterized by an anomalous q-dependence of the relaxation times of τ ∝q -6 and strongly stretched intermediate scattering functions. After the structure of the gel network has been established, evidenced by a constant ξ, the dynamics show aging during the second gelation step accompanied by a change toward ballistic dynamics with τ ∝ q -1 and compressed correlation functions. In the third step, aging continues after the arrest of particle motion. Our observations further suggest that gelation is characterized by stress release as evidenced by anisotropic dynamics once gelation sets in.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metasurfaces for photonic devices

Notably, metasurfaces have attracted significant attention owing to their broad capability to achieve exotic electromagnetic responses, and their potential as optical devices for wavefront control. Wide ranging materials may be used to form metasurfaces including noble and non-noble metals, oxides, ceramics, phase change materials, and semiconductors, permitting versatile and reconfigurable properties ideal for applications. In particular, applications that affect the science and technology of light—i.e., photonics—are of interest and will continue to grow in importance as our society becomes more digitally connected, but yet environmentally conscious.

36 MATERIALS SCIENCE↗

Continuous wave room temperature operation of the 2 $μ$m GaSb-based photonic crystal surface emitting diode lasers

Continuous wave room temperature operation of 2 μm GaSb-based photonic-crystal surface-emitting diode lasers has been realized. The deep etched square mesa devices showed threshold current densities of 500 A/cm 2 at 20 °C. The epi-side down mounted lasers generated above 10 mW of output power in the continuous wave regime and tens of milliwatts in pulses from the 200 × 200 μm 2 aperture. Here, the breakthrough in the device performance parameters was achieved thanks to a highly homogeneous air-pocket retaining epitaxial regrowth process optimized for a specifically designed antimonide diode laser heterostructure. The nanofabrication method utilizing low temperature atomic hydrogen surface cleaning yielded low disorder square lattice of droplet-shaped voids covered by uniform p-cladding layer. The laser emission spectrum as well as near/far field patterns demonstrated peculiar features presumably linked to deformation of the void shape during regrowth and formation of the array of filaments.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Observation of bound valence excited electronic states of deprotonated 2-hydroxytriphenylene using photoelectron, photodetachment, and resonant two-photon detachment spectroscopy of cryogenically cooled anions

Polycyclic aromatic hydrocarbons (PAHs) are common atmospheric pollutants, and they are also ubiquitous in the interstellar medium. Here, we report the study of a complex O-containing PAH anion, the deprotonated 2-hydroxytriphenylene (2-OtPh–), using high-resolution photoelectron imaging and photodetachment spectroscopy of cryogenically cooled anions. Vibrationally resolved photoelectron spectra yield the electron affinity of the 2-OtPh radical as 2.629(1) eV and several vibrational frequencies for its ground electronic state. Photodetachment spectroscopy reveals bound valence excited electronic states for the 2-OtPh– anion, with unprecedentedly rich vibronic features. Evidence is presented for a low-lying triplet state (T1) and two singlet states (S1 and S2) below the detachment threshold. Single-color resonant two-photon photoelectron spectroscopy uncovers rich photophysics for the 2-OtPh– anion, including vibrational relaxation in S1, internal conversion to the ground state of 2-OtPh–, intersystem crossing from S2 to T1, and a long-lived autodetaching shape resonance about 1.3 eV above the detachment threshold. The rich electronic structure and photophysics afforded by the current study suggest that 2-OtPh– would be an interesting system for pump–probe experiments to unravel the dynamics of the excited states of this complex PAH anion.

Chemistry↗

A Bayesian approach to time-domain photonic Doppler velocimetry analysis

Photonic Doppler velocimetry (PDV) is an established technique for measuring the velocities of fast-moving surfaces in high-energy-density experiments. In the standard approach to PDV analysis, the short-time Fourier transform (STFT) is used to generate a spectrogram from which the velocity history of the target is inferred. The user chooses the form, duration, and separation of the window function. Here, in this study, we present a Bayesian approach to infer the velocity directly from the PDV oscilloscope trace, without using the spectrogram for analysis. This is clearly a difficult inference problem due to the highly periodic nature of the data, but we find that with carefully chosen prior distributions for the model parameters, we can accurately recover the injected velocity from synthetic data. We validate this method using PDV data collected at the STAR two-stage light gas gun at Sandia National Laboratories, recovering shock-front velocities in quartz that are consistent with those inferred using the STFT-based approach and are interpolated across regions of low signal-to-noise data. Although this method does not rely on the same user choices as the STFT, we caution that it can be prone to misspecification if the chosen model is not sufficient to capture the velocity behavior. Analysis using posterior predictive checks can be used to establish whether a better model is required, although more complex models come with additional computational cost, often taking more than several hours to converge when sampling the Bayesian posterior. We, therefore, recommend it be viewed as a complementary method to that of the STFT-based approach.

Allison, James R. [First Light Fusion Ltd., Yarnto↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗