Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phase correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Reliable prediction of three-body intermolecular interactions using dispersion-corrected second-order Møller-Plesset perturbation theory

Three-body and higher intermolecular interactions can play an important role in molecular condensed phases. Recent benchmark calculations found problematic behavior for many widely used density functional approximations in treating 3-body intermolecular interactions. Here, we demonstrate that the combination of second-order Møller-Plesset (MP2) perturbation theory plus short-range damped Axilrod-Teller-Muto (ATM) dispersion accurately describes 3-body interactions with reasonable computational cost. The empirical damping function used in the ATM dispersion term compensates both for the absence of higher-order dispersion contributions beyond the triple-dipole ATM term and non-additive short-range exchange terms which arise in third-order perturbation theory and beyond. Empirical damping enables this simple model to out-perform a non-expanded coupled Kohn-Sham dispersion correction for 3-body intermolecular dispersion. The MP2 plus ATM dispersion model approaches the accuracy of O(N{sup 6}) methods like MP2.5 or even spin-component-scaled coupled cluster models for 3-body intermolecular interactions with only O(N{sup 5}) computational cost.

74 ATOMIC AND MOLECULAR PHYSICS↗

Bounce inflation cosmology with Standard Model Higgs boson

It is of great interest to connect cosmology in the early universe to the Standard Model of particle physics. In this paper, we try to construct a bounce inflation model with the standard model Higgs boson, where the one loop correction is taken into account in the effective potential of Higgs field. In this model, a Galileon term has been introduced to eliminate the ghost mode when bounce happens. Moreover, due to the fact that the Fermion loop correction can make part of the Higgs potential negative, one naturally obtains a large equation of state(EoS) parameter in the contracting phase, which can eliminate the anisotropy problem. After the bounce, the model can drive the universe into the standard higgs inflation phase, which can generate nearly scale-invariant power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal pulse sequence modifications and no additional scan time, improving ASL’s clinical applicability.

60 APPLIED LIFE SCIENCES↗

Topological Defects Coupling Smectic Modulations to Intra–Unit-Cell Nematicity in Cuprates

We study the coexisting smectic modulations and intra-unit-cell nematicity in the pseudogap states of underdoped Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}}. By visualizing their spatial components separately, we identified 2{pi} topological defects throughout the phase-fluctuating smectic states. Imaging the locations of large numbers of these topological defects simultaneously with the fluctuations in the intra-unit-cell nematicity revealed strong empirical evidence for a coupling between them. From these observations, we propose a Ginzburg-Landau functional describing this coupling and demonstrate how it can explain the coexistence of the smectic and intra-unit-cell broken symmetries and also correctly predict their interplay at the atomic scale. This theoretical perspective can lead to unraveling the complexities of the phase diagram of cuprate high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Respiratory Motional Effect on Cone-Beam CT in Lung Radiation Surgery

The cone-beam CT (CBCT), which is acquired using an on-board imager (OBI) attached to a linear accelerator, is used effectively in the verification of setup accuracy for lung radiation surgery. In this study, the respiratory organ motional effect on the CBCT was evaluated with a properly devised phantom system, and the level of possible error in conditions of a real clinical process was assessed. In a comparison study between the CBCT in static status and CBCT images acquired in 20 different motional cases, we confirmed that the image quality and information of CBCT were degraded, with an increase of motional ranges in the region of inhomogeneous structures. The 4D-CT MIP (50{approx}55%) for the planning of lung radiation surgery and the 4D-CT MIP (full phase) were compared with CBCT in the various motional cases for the evaluation of the influence of the motional effect on CBCT in the process of the setup error correction. The average ratio of relative difference between plan CT: 4D-CT MIP (50%{approx}55%) and CBCT was 5.79% and between plan CT: 4D-CT MIP (50%{approx}55%) and 4D-CT MIP (full phase) was 42.95% in the phantom study. In the analysis of clinical cases of lung radiation surgery, the gross tumor volumes were compared in each CT image. The average ratio of relative difference between plan CT: 4D-CT MIP (50{approx}55%) and CBCT was 10.72% and between plan CT: 4D-CT MIP (50{approx}55%) and 4D-CT MIP (full phase) was 28.19%. These results showed that, although a respiratory organ motional effect on CBCT introduced variation in image quality, the error as a result of this variation could be estimated relatively low in the setup error correction for a gated-lung radiation surgery when the planning was performed in 4D-CT MIP (50{approx}55%), which already included a related signal of motional effect.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiple interaction points in ghost collisions

The Ghost Collider makes use of unique “ghost” bunches, which are electrically neutral combinations of electrons and positrons within the same RF bucket, eliminates the beam-beam effects typically present at the interaction point (IP) in conventional colliders. This allows for the novel possibility of placing multiple interaction regions in series, achieving additive luminosity without introducing significant disruption. However, to get higher luminosity, the beta functions at the IP reaches millimeter scale, which in turn adds significant chromatic contribution to the collider. Correcting these chromatic effects is essential to maintain beam stability and ensure high luminosity during collider operation. By carefully adjusting the phase advance between two IRs that are placed in series, it becomes possible to cancel chromaticity globally, enabling stable collider operation while preserving high luminosity. In this paper we discuss the design of such IR/IRs to be used in a ghost collider.

Accelerator Physics↗

Detecting chaos in particle accelerators through the frequency map analysis method

The motion of beams in particle accelerators is dominated by a plethora of non-linear effects, which can enhance chaotic motion and limit their performance. The application of advanced non-linear dynamics methods for detecting and correcting these effects and thereby increasing the region of beam stability plays an essential role during the accelerator design phase but also their operation. After describing the nature of non-linear effects and their impact on performance parameters of different particle accelerator categories, the theory of non-linear particle motion is outlined. The recent developments on the methods employed for the analysis of chaotic beam motion are detailed. In particular, the ability of the frequency map analysis method to detect chaotic motion and guide the correction of non-linear effects is demonstrated in particle tracking simulations but also experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The climate of HD 189733b from fourteen transits and eclipses measured by Spitzer

We present observations of six transits and six eclipses of the transiting planet system HD 189733 taken with the Spitzer Space Telescope IRAC camera at 8 microns, as well as a re-analysis of previously published data. We use several novel techniques in our data analysis, the most important of which is a new correction for the detector 'ramp' variation with a double-exponential function which performs better and is a better physical model for this detector variation. Our main scientific findings are: (1) an upper limit on the variability of the day-side planet flux of 2.7% (68% confidence); (2) the most precise set of transit times measured for a transiting planet, with an average accuracy of 3 seconds; (3) a lack of transit-timing variations, excluding the presence of second planets in this system above 20% of the mass of Mars in low-order mean-motion resonance at 95% confidence; (4) a confirmation of the planet's phase variation, finding the night side is 64% as bright as the day side, as well as an upper limit on the night-side variability of 17% (68% confidence); (5) a better correction for stellar variability at 8 micron causing the phase function to peak 3.5 hours before secondary eclipse, confirming that the advection and radiation timescales are comparable at the 8 micron photosphere; (6) variation in the depth of transit, which possibly implies variations in the surface brightness of the portion of the star occulted by the planet, posing a fundamental limit on non-simultaneous multi-wavelength transit absorption measurements of planet atmospheres; (7) a measurement of the infrared limb-darkening of the star, which is in good agreement with stellar atmosphere models; (8) an offset in the times of secondary eclipse of 69 seconds, which is mostly accounted for by a 31 second light travel time delay and 33 second delay due to the shift of ingress and egress by the planet hot spot; this confirms that the phase variation is due to an offset hot spot on the planet; (9) a retraction of the claimed eccentricity of this system due to the offset of secondary eclipse, which is now just an upper limit; and (10) high precision measurements of the parameters of this system. These results were enabled by the exquisite photometric precision of the Spitzer IRAC camera; for repeat observations the scatter is less than 0.35 mmag over the 590 day time scale of our observations after decorrelating with detector parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study

Purpose: To determine detector-specific output correction factors,k{sub Q} {sub c{sub l{sub i{sub n}}}} {sub ,Q} {sub m{sub s{sub r}}} {sup f{sub {sup {sub c}{sub l}{sub i}{sub n}{sub {sup ,f{sub {sup {sub m}{sub s}{sub r}{sub ,}}}}}}}} in 6 MV small photon beams for air and liquid ionization chambers, silicon diodes, and diamond detectors from two manufacturers. Methods: Field output factors, defined according to the international formalism published byAlfonso et al. [Med. Phys. 35, 5179–5186 (2008)], relate the dosimetry of small photon beams to that of the machine-specific reference field; they include a correction to measured ratios of detector readings, conventionally used as output factors in broad beams. Output correction factors were calculated with the PENELOPE Monte Carlo (MC) system with a statistical uncertainty (type-A) of 0.15% or lower. The geometries of the detectors were coded using blueprints provided by the manufacturers, and phase-space files for field sizes between 0.5 × 0.5 cm{sup 2} and 10 × 10 cm{sup 2} from a Varian Clinac iX 6 MV linac used as sources. The output correction factors were determined scoring the absorbed dose within a detector and to a small water volume in the absence of the detector, both at a depth of 10 cm, for each small field and for the reference beam of 10 × 10 cm{sup 2}. Results: The Monte Carlo calculated output correction factors for the liquid ionization chamber and the diamond detector were within about ±1% of unity even for the smallest field sizes. Corrections were found to be significant for small air ionization chambers due to their cavity dimensions, as expected. The correction factors for silicon diodes varied with the detector type (shielded or unshielded), confirming the findings by other authors; different corrections for the detectors from the two manufacturers were obtained. The differences in the calculated factors for the various detectors were analyzed thoroughly and whenever possible the results were compared to published data, often calculated for different accelerators and using the EGSnrc MC system. The differences were used to estimate a type-B uncertainty for the correction factors. Together with the type-A uncertainty from the Monte Carlo calculations, an estimation of the combined standard uncertainty was made, assigned to the mean correction factors from various estimates. Conclusions: The present work provides a consistent and specific set of data for the output correction factors of a broad set of detectors in a Varian Clinac iX 6 MV accelerator and contributes to improving the understanding of the physics of small photon beams. The correction factors cannot in general be neglected for any detector and, as expected, their magnitude increases with decreasing field size. Due to the reduced number of clinical accelerator types currently available, it is suggested that detector output correction factors be given specifically for linac models and field sizes, rather than for a beam quality specifier that necessarily varies with the accelerator type and field size due to the different electron spot dimensions and photon collimation systems used by each accelerator model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of a Pressure Correction Term in the CTF Subchannel Code

CTF is a modernized and improved version of the legacy subchannel code COBRA-TF, being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 to help address CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF user group, and developing the code for use in coupled applications. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model augmented by equations for the droplet field, and it also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent effort to improve CTF capabilities for simulating flows in boiling water reactors (BWRs). The six-equation two-phase flow model is not strongly hyperbolic, meaning that some of its eigenvalues are either not real or not distinct. In a Cauchy sense, and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness, which ensures the uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations. Such terms are often referred to as virtual mass or interfacial pressure correction terms. From a mathematical perspective, this approach adds terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix, thus the imaginary part of the eigenvalues. For this work, an interfacial pressure correction (IPC) term on the same model as what was used for the CATHARE system code, is implemented in CTF. This allows for recovery of a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled, along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem at a pressure of 10 bar. Finally, conclusions and future work are addressed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synchrotron X-ray nanotomographic and spectromicroscopic study of the tricalcium aluminate hydration in the presence of gypsum

The rheology of modern Portland cement (PC) concrete critically depends on the correct dosage of gypsum (calcium sulfate hydrate) to control the hydration of the most reactive phase - tricalcium aluminate (C{sub 3}A). The underlying physio-chemical mechanism, however, remains unsolved mainly due to the lack of high-spatial-resolved and chemistry-sensitive characterization of the C{sub 3}A dissolution frontier. Here, we fill this gap by integrating synchrotron-radiation based crystallographic, photon-energy-dependent spectroscopic and high-resolution morphological studies of the C{sub 3}A hydration product layer. We propose that ettringite (6CaO·Al{sub 2}O{sub 3}·SO{sub 3}·32H{sub 2}O) is the only hydration product after the initial reaction period and before complete gypsum dissolution. We quantify the 2D and 3D morphology of the ettringite network, e.g. the packing density of ettringite at various surface locations and the surface dissolution heterogeneity. Our results show no trace of a rate-controlling diffusion barrier. We expect our work to have significant impact on modeling the kinetics and morphological evolution of PC hydration.

36 MATERIALS SCIENCE↗

The surface triple-coupling on single crystalline cathode for lithium ion batteries

Single crystalline (SC) cathode materials, which are less susceptible to micro/nano-cracks formation and offer better structure stability compared to the polycrystalline counterpart, have attained great attention. However, the parasitic side reactions at the cathode-electrolyte interface induces the loss of active species, which consequently leads to continual degradation of the electrochemical performances. Herein, a triple coupling of concentration-gradient Na+, F- co-doping and surface NaF coating are exploited for the first time on SC LiNi 0.5C o 0.2 Mn 0.3 O 2 cathode by the hydrolysis of NaPF 6 . This process regulates the external structure of materials by constructing a “sandwich” configuration from surface to bulk: rock salt - mixing zone - layered phase. The detailed interface transformation mechanism is revealed by Neutron powder diffraction (NPD), spherical aberration corrected high-resolution scanning transmission electron microscopy (HR-STEM), electron energy loss spectroscopy (EELS), and Ar+ sputtering assisted X-ray photoelectron spectroscopy (XPS). The synergistic effects endow the SC cathode with outstanding capacity retentions: 91.3% at 25 °C and 85% at 45 °C, after 500 cycles at 5 C between 3.0 and 4.5 V. In addition, a high full-cell reversible capacity of 168.9 mAh g -1 with a capacity retention of 92.4% is achieved after 300 cycles at 1 C. Multiple characterizations further indicate that these superior results are mainly ascribed to the overall structure integrity of SC material, the thin cathode electrolyte interface, high content of lithium fluoride, and the low solubility of transition metal ions. This work opens a new avenue to construct a benign interface towards high-performance lithium ion batteries.

lithium ion batteries↗

Size quantization of an exciton: A toy model of the “dead layer”

In this paper, size-quantization levels of an exciton in large nanocrystals is studied theoretically. For the nanocrystal size, L , much bigger than the Bohr radius, a B , the level positions do not depend on a B . The correction to the levels in a small parameter a B / L depends on the reflection phase of the exciton from the boundary. Calculation of this phase constitutes a three-body problem: electron, hole, and the boundary. This calculation can be performed analytically in the limit when the hole is much heavier than the electron. Physically, a slow motion of the hole towards the boundary takes place in the effective potential created by the fast motion of the electron orbiting the hole and touching the boundary. As a result, the hole is reflected before reaching the boundary. The distance of the closest approach of the hole to the boundary (the dead layer) exceeds a B parametrically .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗

Revealing the reaction mechanisms of Li–O2 batteries using environmental transmission electron microscopy

The capacity, Coulombic efficiency, rate, and cyclability of a Li-O2 battery critically depend on the electrode reaction mechanism and the structure/morphology of the reaction product as well as their spatial and temporal evolution1-8, which are all further complicated by the choice of different electrolyte. For the case of aprotic cell, the discharge product, Li2O2, is formed through solution and surface mechanisms9,10, but little is known on the formation mechanism of the perplexing morphology of the reaction product11-15. For the case of Li-O2 battery using solid electrolyte, neither electrode reaction mechanism nor the nature of the reaction production is known. Herein, we reveal the full cycle reaction pathway for Li-O2 batteries and its correlation with the nature of the reaction product. Using an aberration-corrected environmental TEM under oxygen environment, we captured, for the first time, the morphology and phase evolution on the carbon nanotube (CNT) cathode of a working solid-state Li-O2 nano-battery16 and directly correlated these features with electrochemical reaction. We found that the oxygen reduction reaction on CNTs initially produces LiO2, which subsequently evolves to Li2O2 and O2 through disproportionation reaction. Surprisingly it is just the releasing of O2 that inflates the particles to a hollow structure with a Li2O outer surface layer and Li2O2 inner-shell, demonstrating that, in general, accommodation of the released O2 coupled with the Li+ ion diffusion and electron transport paths across both spatial and temporal scales critically governs the morphology of the discharging/charging product in Li-O2 system. We anticipate that the direct observation of Li-O2 reaction mechanisms and their correlation with the morphology of the reaction product set foundation for quantitative understanding/modeling of the electrochemical processes in the Li-O2 system, enabling rational design of both solid-state and aprotic Li-O2 batteries.

25 ENERGY STORAGE↗

Comparison of SiC MOSFET‐based and GaN HEMT‐based high‐efficiency high‐power‐density 7.2 kW EV battery chargers

As two exemplary candidates of wide‐bandgap devices, SiC MOSFETs and GaN HEMTs are regarded as successors of Si devices in medium‐to‐high‐voltage (>1200 V) and low‐voltage (<650 V) domains, respectively, thanks to their excellent switching performance and thermal capability. With the introduction of 650 V SiC MOSFETs and GaN HEMTs, the two technologies are in direct competition in <650 V domains, such as Level 2 battery chargers for electric vehicles (EVs). This study applies 650 V SiC and GaN to two 240 VAC/7.2 kW EV battery chargers, respectively, aiming to provide a head‐to‐head comparison of these two devices in terms of overall efficiency, power density, thermal performance, and cost. The charger essentially is an indirect matrix converter with a dual‐active‐bridge stage handling the power factor correction and power delivery simultaneously. These two chargers utilise the same control strategy, varying the phase‐shift and switching frequency to cover the wide input range (80–260 VAC) and wide output range (200 V–450 VDC). Experimental results indicated that at the same efficiency level, the GaN charger is smaller, more efficient and cheaper, while the SiC charger has a better thermal performance.

Taylor, Allan↗

1-D profiling using highly dispersive guided waves

Corrosion is one of the industries major issues regarding the integrity of assets. Currently, inspections are conducted at regular intervals to ensure a sufficient integrity level of these assets. Cost reduction while maintaining a high level of reliability and safety of installations is a major challenge. There are many situations where the actual defect location is not accessible, e.g., a pipe support or a partially buried pipe. Guided wave tomography has been developed to reconstruct the wall thickness of steel pipes. In case of bottom of the line corrosion, i.e., a single corrosion pit, a simpler approach may be followed. Data is collected in a pitch-catch configuration at the 12 o'clock position using highly dispersive guided waves. After dispersion correction the data collapses to a short pulse, any residual dispersion indicates wall loss. The phase spectrum is used to invert for the wall thickness profile in the circumferential direction, assuming a Gaussian defect profile. The approach is evaluated on numerically simulated and on measured data. The method is intended for rapid, semi-quantitative screening of pipes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An algorithm to unveil the inner structure of objects concealed by beam divergence in radiographic image acquisition systems

Two main parameters rule the performance of an Image Acquisition System, namely, spatial resolution and contrast. For radiographic systems using cone beam arrangements, the farther the source, the better the resolution, but the contrast would diminish due to the lower statistics. A closer source would yield a higher contrast but it would no longer reproduce the attenuation map of the object, as the incoming beam flux would be reduced by unequal large divergences and attenuation factors. This work proposes a procedure to correct these effects when the object is comprised of a hull - or encased in it - possessing a shape capable to be described in analytical geometry terms. Such a description allows the construction of a matrix containing the attenuation factors undergone by the beam from the source until its final destination at each coordinate on the 2D detector. Each matrix element incorporates the attenuation suffered by the beam after its travel through the hull wall, as well as its reduction due to the square of distance to the source and the angle it hits the detector surface. When the pixel intensities of the original image are corrected by these factors, the image contrast, reduced by the overall attenuation in the exposure phase, are recovered, allowing one to see details otherwise concealed due to the low contrast. In order to verify the soundness of this approach, synthetic images of objects of different shapes, such as plates and tubes, incorporating defects and statistical fluctuation, have been generated, recorded for further comparison and afterwards processed to improve their contrast. The developed algorithm which, generates processes and plots the images has been written in Fortran 90 language. As the resulting final images exhibit the expected improvements, it therefore seemed worthwhile to carry out further tests with actual experimental radiographies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗