Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A highly oxygen reduction reaction active and CO 2 durable high-entropy cathode for solid oxide fuel cells

One big obstacle for the oxygen reduction reaction (ORR) electrode in solid oxide fuel cells (SOFCs) is the poor reaction activity and fast degradations caused by CO 2 poisoning. Here, in this study, we report our design of an active A-site Ca-rich high-entropy Pr 0.1875 Ba 0.1875 Sr 0.1875 La 0.1875 Ca 0.25 CoO 3-δ (PBSLC 25 C) electrode, guided by the O p-band theory. Here, when applied as a cathode in solid oxide fuel cells (SOFCs), it demonstrates high ORR activity and excellent CO 2 tolerance under realistic operating conditions. Ni-YSZ-based anode-supported cells with PBSLC 25 C cathodes demonstrate excellent peak power densities of 1.14 W cm -2 , 1.04 W cm -2 , and 0.77 W cm -2 in the air with 1%, 5%, and 10% CO 2 , respectively, at 750 °C. The engineered high-entropy PBSLC 25 C effectively diminishes the CO 2 poisoning effect and maintains active surfaces for fast oxygen exchange, as confirmed by the cell durability test in air containing CO 2 (5 and 10 vol%), Raman spectroscopy, and density functional theory calculations.

30 DIRECT ENERGY CONVERSION↗

In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane

There are two strategies to lower overall project costs to an extent that will make many potential sustainable hydropower sites economically viable: (1) design standardized/modular components; (2) use advanced tools to reduce environmental evaluation costs. In this study an autonomous sensor device (Sensor Fish) was used to study a Francis turbine retrofitted with a modular guide vane. The median nadir pressures measured were 74.7, 66.6, and 56.6 kPaA for 90-, 190-, and 380-kW operating conditions respectively. These nadir pressures were compared to other Francis turbines studied using Sensor Fish and were found to be within the same range. The proportion of Sensor Fish releases with severe acceleration events (acceleration = 95G) was also investigated. The proportion ranged from 73 to 80% (runner region), 50 to 64% (guide vane region), and 9 to 28% (draft tube region), which was within the range of the other turbines used for comparison. The Sensor Fish testing that was conducted at Hurley Dam demonstrates that the modular guide vane that was retrofitted to the existing Francis turbine is potentially a suitable replacement that can provide biological performance similar to the guide vane used with other existing Francis turbines, but with the benefit of reduced fabrication costs.

13 HYDRO ENERGY↗

Thermochemical reduction modeling in a high-temperature moving-bed reactor for energy storage: 1D model

The design of robust and efficient high-temperature thermochemical reactors and determination of operating conditions are critical steps toward enabling high-efficiency long-duration solar energy storage. This work presents a computational model for the thermal reduction of a metal oxide material (Mg-Mn-O) up to 1450 °C and the coupled complex transport phenomena in a novel tubular thermal reactor design that features the capability for a high extent-of-reduction (high energy storage density) and inherent heat recuperation. A one-dimensional model coupling counter-current gas–solid flow, two-phase heat transfer, thermochemical redox reactions, and species transport in a moving-bed reactor is developed. Simplified versions of the model are validated with published results in the literature for packed beds with both inert and reactive particles; the fully coupled model is also validated with experimental measurements of a moving-bed reactor in terms of local temperatures and oxygen release at the exit. Detailed comparisons on the effects of different boundary conditions in the reaction zone (prescribed wall temperature vs. heat flux conditions) and formulations based on a simple uniform flow assumption vs. plug flow using Ergun equation for gas flow are investigated. The results are compared with experimental measurements, and for all cases, the energy flow components in the reactor system and the thermal to chemical conversion efficiency and overall system efficiency are computed. Finally, the predicted high thermal-to-chemical efficiency ~95% and system efficiency ~30% agree with experimental measurements.

25 ENERGY STORAGE↗

Analysis of controls for integrated energy storage system in energy arbitrage configuration with concrete thermal energy storage

Novel highly detailed NuScale reactor and turbo-generator models have been built in Modelica to analyze potential controls for an integrated energy system (IES) configuration combining a nuclear reactor and concrete thermal energy storage (CTES) operating in energy arbitrage. A shakedown test demonstrates the viability of the control schemes to operate across expected operating conditions while maintaining safety limits and buffers. A five-day data set from Idaho is used to show a load-following application of this system that increases the average reactor power level by 20% over the data set and matching demand at nearly all points. Here, by integrating these models, feedback mechanisms across the primary and secondary sides of the nuclear reactor are integrated, and realistic control evaluation is done. All models are consistent with the Hybrid repository, a suite of Modelica models, maintained at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A continuum model for heat and mass transfer in moving-bed reactors for thermochemical energy storage

In this work, a continuum heat and mass transfer model coupling transport phenomena and high-temperature thermochemical reactions is developed for stationary packed-bed and counter-flow moving-bed reactors. After presenting the general modeling framework, we focus on the 2D axisymmetric version of the model for which validation is conducted with experimental results for a packed-bed reactor in the literature for manganese-iron oxide reduction/oxidation and an in-house counter-flow moving-bed reactor for magnesium-manganese oxide reduction up to 1450 °C. Transient simulation results including the local distributions of gas/solid temperatures, oxygen concentration and the extent of reaction, as well as the various energy flow components and energy conversion efficiencies are reported. The results based on the 2D axisymmetric model are also compared with those obtained from a previous 1D model. The comparison shows that capturing the radial variation is critical in reactor modeling and the 2D results demonstrate improved agreement with experiments. Specifically, large temperature variations along the radial direction are observed especially in the reaction zone; this non-uniform radial temperature distribution has a significant effect on the chemical reaction extent due to its strong dependence on temperature; and the overall oxygen concentration at the reactor exit and the predicted system efficiency are slightly lower in the 2D model compared to the 1D model. Finally, the present heat and mass transfer model can provide valuable insights into reactor design, scale-up, and operating conditions selection to maximize system energy storage efficiency.

25 ENERGY STORAGE↗

Optimizing the physical design and layout of a resilient wind, solar, and storage hybrid power plant

We report as wind and solar technologies improve and their costs decrease, the share of power produced by these sources will increase. As the market penetration increases, these power sources will need to provide grid services, such as dispatchability, in addition to providing energy. One way to reduce variability, provide higher quality power to the grid, and address local grid stability issues is through colocating wind and solar power plants. In addition to operating reliably during normal operating conditions, in scenarios with high penetrations of renewable generation, it is important that these hybrid plants can withstand production disruptions and continue to supply power despite prolonged resource reduction, extreme weather events, or other disruptions. In this paper, we present a methodology to optimize a wind-solar-battery hybrid power plant down to the component level that is resilient against production disruptions and that can continually produce some minimum required power. We introduce the models and assumptions we used to simulate a hybrid power plant as well as the design variable parameterization and specific methods we used to optimize the plant. We demonstrate the performance of our method by comparing a plant optimized for different objectives, generation outage durations, minimum power requirements, and power purchase agreements. Although the plant design is sensitive to model parameters and various other assumptions, our results demonstrate some of the optimal designs that occur in different scenarios and what one should expect when designing a hybrid wind-solar-storage power plant.

14 SOLAR ENERGY↗

Coupled loads analysis of a novel shared-mooring floating wind farm

Shared mooring lines are a method to reduce the stationkeeping cost of floating offshore wind farms; however, their impacts on floating array dynamics are not yet well understood. Here this article presents advancements to floating wind farm simulation capabilities that allow the dynamic modeling of shared-mooring floating wind arrays - specifically, platform coupling through shared lines and proper phasing of wave loads across the array. These capabilities are demonstrated on a 10-turbine shared-mooring array featuring two staggered rows of wind turbines. A baseline array design with individually moored turbines is used as a basis for comparison. Coupled analysis using FAST.Farm shows that the shared-mooring design has smaller fluctuations in surge when compared to the baseline design. The mean and maximum platform offsets are highest in normal operating conditions, but the maximum mooring line tensions are highest in 50-year storm conditions. Power spectral density analysis of platform surge and sway motions shows that the shared mooring configuration does not introduce any significant inter-platform resonances. The tower-base bending moment statistics and the line tension damage equivalent loads indicate no consequential differences in turbine loading or mooring fatigue life. Anchor load analysis shows that the total required anchor capacity for the shared-mooring array is decreased by approximately 25% when shared anchors are used. Dynamic simulations of the shared mooring system under line failures show that remaining line tensions stay within bounds and that offsets are significantly smaller when compared to the baseline design. Overall, the results show that shared moorings do not introduce any dynamic response concerns in this floating wind array design.

17 WIND ENERGY↗

A valuation framework for customers impacted by extreme temperature-related outages

Extreme temperature outages can lead to not just economic losses but also various non-energy impacts (NEI), such as increased mortality rates, property damage, and reduced productivity, due to significant degradation of indoor operating conditions caused by service disruptions. However, existing resilience assessment approaches lack specificity for extreme temperature conditions. They often overlook temperature-related mortality and neglect the customer characteristics and grid response in the calculation, despite the significant influence of these factors on NEI-related economic losses. This paper aims to address these gaps by introducing a comprehensive framework to estimate the impact of resilience enhancement not only on the direct economic losses incurred by customers but also on potential NEI, including mortality and the value of statistical life during extreme temperature-related outages. The proposed resilience valuation integrates customer characteristics and grid response variables based on a scalable grid simulation environment. This study adopts a holistic approach to quantify customer-oriented economic impacts, utilizing probabilistic loss scenarios that incorporate health-related factors and damage/loss models as a function of exposure for valuation. The proposed methodology is demonstrated through comparative resilient outage planning, using grid response models emulating a Texas weather zone during the 2021 winter storm Uri. The case study results show that enhanced outage planning with hardened infrastructure can improve the system resilience and thereby reduce the relative risk of mortality by 16% and save the total costs related to non-energy impacts by 74%. In conclusion, these findings underscore the efficacy of the framework by assessing the financial implications of each case, providing valuable insights for decision-makers and stakeholders involved in extreme-weather related resilience planning for risk management and mitigation strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Broad range material-to-system screening of metal–organic frameworks for hydrogen storage using machine learning

Hydrogen is pivotal in the transition to sustainable energy systems, playing major roles in power generation and industrial applications. Metal–organic frameworks (MOFs) have emerged as promising mediums for efficient hydrogen storage. However, identifying potential candidates for deployment is challenging due to the vast number of currently available synthesized MOFs. This study integrates molecular simulations, machine learning, and techno-economic analysis to evaluate the performance of MOFs across broad operation conditions for hydrogen storage applications. While previous screenings of MOF databases have predominantly emphasized high hydrogen capacities under cryogenic conditions, this study reveals that optimal temperatures and pressures for cost minimization depend on the raw price of the MOF. Specifically, when MOFs are priced at $15/kg, among the 9720 MOFs tested, 9692 MOFs achieve the lowest cost at temperatures between 170 K and 250 K and a pressure of 150 bar. Under these optimal conditions, 362 MOFs deliver a lower levelized cost of storage than 350 bar compressed gas hydrogen storage. Furthermore, this study reveals key material properties that result in low system cost, such as high surface areas (>3000 m2/g), large void fractions (>0.78), and large pore volumes (>1.1 cm3/g).

Hydrogen storage↗

Open data sets for assessing photovoltaic system reliability

Photovoltaic (PV) systems have become a cornerstone of renewable energy strategies, particularly due to the significant reduction in solar power costs over the past decade. However, the long-term reliability of PV installations presents a persistent challenge, requiring the development of advanced monitoring and predictive maintenance strategies. A wide range of data types is used to evaluate the health of PV systems, including environmental conditions, electrical performance, and inspection imagery. These data enable methodologies such as machine learning (ML) models for lifetime prediction and computer vision techniques for defect detection. However, the acquisition of high-quality and comprehensive data is difficult, particularly in terms of long-term consistency and data variety. Publicly available data sets serve as valuable resources for addressing these challenges, but they often suffer from fragmentation and are difficult to access. This paper presents a comprehensive review of existing open-source data sets related to PV degradation, analyzing their features, functionalities, and potential applications. We categorize these data sets based on the specific aspects of PV system information they cover, such as environmental conditions, operational monitoring, image inspection and module materials, and propose relevant tools and ML models for processing them. In addition, we propose practices for future data collection and usage, while also discussing potential directions in data-driven research. Our aim is to enhance data utilization and publication among researchers and industry professionals, promoting a deeper understanding of the role of data in enhancing the performance and durability of PV systems.

14 SOLAR ENERGY↗

Benchmark of numerical modeling approaches on the systematic performance evaluation of wave energy converters

Different numerical modeling methods have been developed and applied to evaluate a variety of performance indicators of wave energy converters (WECs), including the power performance, structural loads, levelized cost of energy, etc. Based on the modeling fidelity, the commonly used numerical modeling approaches can be classified as linear modeling, weakly nonlinear modeling and fully nonlinear modeling approaches. Each method differs in accuracy and computational efficiency, making them suitable for different stages of WEC design. However, the selection of modeling approach could significantly impact evaluation outcomes. For instance, simplified linear models may underestimate structural loads or overestimate energy production in some operational conditions, potentially leading to less cost-effective designs. Given the widespread utilization of these models, it is essential to understand the uncertainties brought by them in performance evaluations. This work is dedicated to benchmarking different linear-potential-flow-based numerical models for evaluating the systematic performance of WECs. Three representative numerical modeling approaches are considered in this work, including linear frequency-domain modeling, statistically linearized spectral-domain modeling and Cummins equation-based nonlinear time-domain modeling. A generic point absorber WEC is considered as the research reference in this work, and different sea sites are taken into account. The numerical models are utilized to predict critical performance indicators, including power performance, the annual energy production, the capacity factor, the levelized cost of energy and the PTO fatigue loads. By comparing the results, this work identifies the uncertainties associated with different modeling approaches in evaluating WEC performance.

Fatigue↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Combined Cr and S poisoning behaviors of La 1-x Sr x MnO 3±δ and La 1-x Sr x Co 1-y FeyO 3-δ cathodes in solid oxide fuel cells

Although the individual effects of airborne Cr and S contaminants on SOFC cathode performance degradation have been extensively studied, the combined effects of Cr and S contaminants remain largely unexplored. Under the real SOFC operating condition where the Cr and S species coexist, their effects may compete, affecting the poisoning behavior. Here, our investigation reveals that the combined Cr and S poisoning behavior of LSCF remains different from those of individual Cr and S poisonings, while the combined poisoning mechanism of LSM is equivalent to the sum of those of individual Cr and S effects. For LSCF electrode, gaseous Cr species are deposited mainly at the LSCF/GDC interface by electrochemical reduction, rather than forming SrCrO 4 on LSCF surfaces (as in the case of Cr-only poisoning), indicating no reaction between Cr vapors and SrO on the LSCF surface. Thermodynamic analysis demonstrates that the SrO on LSCF surface absorbs SO 2 (g) and thereby loses the Cr-gettering effect, allowing Cr vapors to flow through LSCF and to reach the LSCF/GDC interface where the Cr deposition occurs. Unlike LSCF, LSM electrode shows cumulative effects of Cr and S, as Cr accumulation occurs at the triple-phase boundary and S absorption takes place at localized Sr-rich regions.

36 MATERIALS SCIENCE↗

A new perspective on the initial hydrogenation of $\mathrm{TiFe_{0.9}M_{0.1}}$ ($\mathrm{M = V, Cr, Fe, Co, Ni}$) gained from surface oxide analysis and nucleation thermodynamics

Despite the promise of TiFe-based alloys as low-cost solid-state hydrogen storage materials with mild operating conditions and reasonable hydrogen capacity, their initial hydrogenation process is difficult, hindering broad utilization. The effect of alloying element on the initial hydrogenation kinetics of TiFe alloys, TiFe 0.9 M 0.1 (M = V, Cr, Fe, Co and Ni), was evaluated by analyzing changes to the passivating surface oxide layer that inhibits hydrogen permeation, as well as the ease of initial-stage hydrogen absorption into the underlying matrix. X-ray photoelectron spectroscopy and atom probe tomography revealed key variations in surface oxide compositions and thinning of the passivating oxide layer compared to pure TiFe, which suggests suppressed oxide growth by alloying-induced elemental redistribution. At the same time, density functional theory calculations predicted exothermic formation of hydride nuclei when alloying with V or Cr, as well as a reduced nucleation barrier when alloying with Co or Ni. Overall, these results are consistent with the observed experimental trend of the activation kinetics. We propose that improvements in activation kinetics of TiFe with alloying arises from the combined effect of reduced passivating oxide thickness and easier hydride nucleation, offering a starting point for alloy design strategies towards further improvement.

25 ENERGY STORAGE↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗