Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear physics detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Evaporation residue excitation function from complete fusion of {sup 19}F with {sup 184}W

Evaporation residue cross sections for {sup 19}F+{sup 184}W have been measured at beam energies in the range of 90-130 MeV using the Heavy Ion Reaction Analyzer at the Inter University Accelerator Centre. A new approach, based on Monte Carlo calculations, has been adopted for estimating evaporation residue (ER) transmission efficiency. The challenges in the detection of ERs caused by the presence of isomeric states with longer half-lives have been thoroughly discussed. Measured cross sections have been fitted with statistical model calculations treating the fission barrier as an adjustable parameter. Comparison with other neighboring systems with nearly similar entrance-channel mass asymmetry indicates the onset of instability in the compound nucleus {sub 83}{sup 203}Bi{sub 120} after crossing of the Z=82 shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of nonplanar field emission via secondary electron detection in near field emission scanning electron microscopy

Nonplanar field emission from electrochemically etched tungsten field emitters has been observed using near field emission scanning electron microscopy. Close-proximity field emission in adequate ultrahigh vacuum conditions was implemented to attain Fowler-Nordheim plots using typical imaging parameters. The emission radii deduced via a detailed, spherical surface field emission theory, by [Edgcombe and de Jonge, J. Phys. D 40, 4123 (2007)], reveal that our sharpest tip asperities are less than a nanometer. This yields a spatial resolution on the order of one nanometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inelastic partial {gamma}-ray cross sections of {sup 150}Sm+n reactions for E{sub n} = 1-15 MeV

The {sup 150}Sm(n,n'{gamma}) reaction was measured from E{sub n} = 1 to 15 MeV at the Los Alamos Neutron Science Cemter (LANSCE). The {gamma} rays were detected with the Compton-suppressed Germanium Array for Neutron Induced Excitations (GEANIE). Measured {gamma}-ray excitation functions were converted to partial {gamma}-ray cross sections, Twenty four individual {gamma}-rays up to E{sub x} = 1.8 MeV in {sup 150}Sm were measured. Results are compared with enhanced Hauser Feshbach model calculations: the spin distribution in the pre-equilibrium reaction is calculated with the quantum mechanical model of Feshbach, Kerman and Koonin. The particle transmission coefficients were calculated with two different global optical model potential parameter sets. We employed the coupled-channel optical model based on the soft rotor model and with spherical potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Luminous dark matter

We propose a dark matter model in which the signal in direct detection experiments arises from electromagnetic, not nuclear, energy deposition. This can provide a novel explanation for the DAMA result while avoiding many direct detection constraints. The dark matter state is taken nearly degenerate with another state. These states are naturally connected by a dipole moment operator, which can give both the dominant scattering and decay modes between the two states. The signal at DAMA then arises from dark matter scattering in the Earth into the excited state and decaying back to the ground state through emission of a single photon in the detector. This model has unique signatures in direct detection experiments. The density and chemical composition of the detector is irrelevant - only the total volume affects the event rate. In addition, the spectrum is a monoenergetic line, which can fit the DAMA signal well. This model is readily testable at experiments such as CDMS and XENON100 if they analyze their low-energy, electronic recoil events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of Europium-Doped Strontium Iodide, Transparent Ceramics and Bismuth-loaded Polymer Scintillators

Recently discovered scintillators for gamma ray spectroscopy, single crystal SrI{sub 2}(Eu), GYGAG(Ce) transparent ceramic and Bismuth-loaded plastics, offer resolution and fabrication advantages compared to commercial scintillators, such as NaI(Tl) and standard PVT plastic. Energy resolution at 662 keV of 2.7% is obtained with SrI{sub 2}(Eu), while 4.5% is obtained with GYGAG(Ce). A new transparent ceramic scintillator for radiographic imaging systems, GLO(Eu) offers high light yield of 70,000 Photons/MeV, high stopping, and low radiation damage. Implementation of single crystal SrI{sub 2}(Eu), Gd-based transparent ceramics, and Bi-loaded plastic scintillators can advance the state-of-the art in ionizing radiation detection systems.

36 MATERIALS SCIENCE↗

Indirect Estimation of Radioactivity in Containerized Cargo

Detecting illicit nuclear and radiological material in containerized cargo challenges the state of the art in detection systems. Current systems are being evaluated and new systems envisioned to address the need for the high probability of detection and extremely low false alarm rates necessary to thwart potential threats and extremely low nuisance and false alarm rates while maintaining necessary to maintain the flow of commerce impacted by the enormous volume of commodities imported in shipping containers. Maintaining flow of commerce also means that primary inspection must be rapid, requiring relatively indirect measurements of cargo from outside the containers. With increasing information content in such indirect measurements, it is natural to ask how the information might be combined to improved detection. Toward this end, we present an approach to estimating isotopic activity of naturally occurring radioactive material in cargo grouped by commodity type, combining container manifest data with radiography and gamma spectroscopy aligned to location along the container. The heart of this approach is our statistical model of gamma counts within peak regions of interest, which captures the effects of background suppression, counting noise, convolution of neighboring cargo contributions, and down-scattered photons to provide physically constrained estimates of counts due to decay of specific radioisotopes in cargo alone. Coupled to that model, we use a mechanistic model of self-attenuated radiation flux to estimate the isotopic activity within cargo, segmented by location within each container, that produces those counts. We demonstrate our approach by applying it to a set of measurements taken at the Port of Seattle in 2006. This approach to synthesizing disparate available data streams and extraction of cargo characteristics holds the potential to improve primary inspection using current detection capabilities and to enable simulation-based evaluation of new candidate detection systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasmonic light yield enhancement of a liquid scintillator

We demonstrate modifications to the light yield properties of an organic liquid scintillator due to the localization of the tertiary fluorophore component to the surface of Ag-core silica-shell nanoparticles. We attribute this enhancement to the near-field interaction of Ag nanoparticle plasmons with these fluor molecules. The scintillation light yield enhancement is shown to be equal to the fluorescence enhancement within measurement uncertainties. With a suitable choice of plasmon energy and scintillation fluor, this effect may be used to engineer scintillators with enhanced light yields for radiation detection applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of the performance of {sup 3}He alternative detectors with MCNPX

This paper describes the techniques that are available to calculate the performance of {sup 3}He alternative detectors using MCNPX. Calculations of the performance of safeguards detectors that use {sup 3}He have been successfully carried out for many years. In the case of coincidence or multiplicity counting, specific tallies have been implemented to calculate the Singles, Doubles and Triples counting rates. The implementation of the method was done in such a way that it equates every capture in some nuclide in the detection zone with the production of an electronic pulse from the detector. This is a very good approximation for {sup 3}He detectors and BF{sub 3} detectors. However it is not appropriate for detectors such as boron-lined proportional counters, in which the fraction of capture events leading to an electronic pulse above threshold is very dependent on the geometric arrangement, in particular the thickness and composition of the boron-containing layer. This paper gives calculations of the ideal pulse height distributions to be expected from different detector types and gives values for the probability, as a function of detector energy threshold, that a neutron capture reaction will cause an electronic pulse from the detector. This is termed the electronic efficiency. This electronic detection efficiency depends very little on the energy of the captured neutron, which in most practical cases are heavily weighted towards thermal energies. It does not depend on the position of the source neutron or moderation in the sample. For cases of interest to nuclear safeguards, measurement of uranium and plutonium in specially designed detectors, the spectrum of detected neutrons is fairly constant and thus the electronic detection efficiency becomes a detector constant. The paper discusses how the electronic detection efficiency needs to be included in the calculation of Singles, Doubles and Triples, and describes proposals to improve the tallying capability of MCNPX for such cases. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FERMI LARGE AREA TELESCOPE GAMMA-RAY DETECTION OF THE RADIO GALAXY M87

We report the Fermi Large Area Telescope (LAT) discovery of high-energy (MeV/GeV) gamma-ray emission positionally consistent with the center of the radio galaxy M87, at a source significance of over 10sigma in 10 months of all-sky survey data. Following the detections of Cen A and Per A, this makes M87 the third radio galaxy seen with the LAT. The faint point-like gamma-ray source has a >100 MeV flux of 2.45 (+-0.63) x 10{sup -8} photons cm{sup -2} s{sup -1} (photon index = 2.26 +- 0.13) with no significant variability detected within the LAT observation. This flux is comparable with the previous EGRET upper limit (<2.18 x 10{sup -8} photons cm{sup -2} s{sup -1}, 2sigma), thus there is no evidence for a significant MeV/GeV flare on decade timescales. Contemporaneous Chandra and Very Long Baseline Array data indicate low activity in the unresolved X-ray and radio core relative to previous observations, suggesting M87 is in a quiescent overall level over the first year of Fermi-LAT observations. The LAT gamma-ray spectrum is modeled as synchrotron self-Compton (SSC) emission from the electron population producing the radio-to-X-ray emission in the core. The resultant SSC spectrum extrapolates smoothly from the LAT band to the historical-minimum TeV emission. Alternative models for the core and possible contributions from the kiloparsec-scale jet in M87 are considered, and cannot be excluded.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron-10 Lined Proportional Counter Wall Effects

The Department of Energy Office of Nuclear Safeguards (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a boron-lined proportional tube based system in the configuration of a coincidence counter. This report provides information about how variations in proportional counter radius and gas pressure in a typical coincident counter design might affect the observed signal from boron-lined tubes. A discussion comparing tubes to parallel plate counters is also included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent progress in low energy neutrino scattering physics and its implications for the standard and beyond the standard model physics

Neutrinos continue to provide a testing ground for the structure of the standard model of particle physics as well as hints towards the physics beyond the standard model. Neutrinos of energies spanning over several orders of magnitude, originating in many terrestrial and astrophysical processes, have been detected via various decay and interaction mechanisms. At MeV scales, there has been one elusive process, until a few years ago, known as coherent elastic neutrino-nucleus scattering (CEvNS) that was theoretically predicted over five decades ago but was never observed experimentally. The recent experimental observation of the CEvNS process by the COHERENT collaboration at a stopped pion neutrino source has inspired physicists across many subfields. This has vital implications for nuclear physics, high-energy physics, astrophysics, and beyond. CEvNS, being a low-energy process, provides a natural window to study light, weakly-coupled, new physics in the neutrino sector. In this review, we intend to provide the current status of low energy neutrino scattering physics and its implications for the standard and beyond the standard model physics. We discuss the general formalism of calculating the tree-level CEvNS cross section and present estimated theoretical uncertainties on the CEvNS cross section stemming from different sources. We also discuss the inelastic scattering of tens of MeV neutrinos that have implications for supernova detection in future neutrino experiments. We discuss how the CEvNS experiments can be used as a testing ground for the Standard Model (SM) weak physics as well as in searching for the Beyond the Standard Model (BSM) physics signals. Any deviation from the SM predicted event rate either with a change in the total event rate or with a change in the shape of the recoil spectrum, could indicate new contributions to the interaction cross-section. The SM implications include the study of weak nuclear form factor and weak mixing angle. The BSM studies include non-standard interactions, neutrino electromagnetic properties, and sterile neutrino searches. In conclusion, stopped pion facilities are also a copious source of neutral and changed mesons that allow study of several dark sector physics scenarios such as vector portal models, leptophobic dark matter as well as axion-like particle searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact molecular beam machine

We have developed a compact, low cost, modular, crossed molecular beam machine. The new apparatus utilizes several technological advancements in molecular beams valves, ion detection, and vacuum pumping to reduce the size, cost, and complexity of a molecular beam apparatus. We apply these simplifications to construct a linear molecular beam machine as well as a crossed-atomic and molecular beam machine. The new apparatus measures almost 50 cm in length, with a total laboratory footprint less than 0.25 m{sup 2} for the crossed-atomic and molecular beam machine. We demonstrate the performance of the apparatus by measuring the rotational temperature of nitric oxide from three common molecular beam valves and by observing collisional energy transfer in nitric oxide from a collision with argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detectability prediction for a thermoacoustic sensor in the breazeale nuclear reactor pool

Laboratory experiments have suggested that thermoacoustic engines can be in- corporated within nuclear fuel rods. Such engines would radiate sounds that could be used to measure and acoustically-telemeter information about the op- eration of the nuclear reactor (e.g., coolant temperature or uxes of neutrons or other energetic particles) or the physical condition of the nuclear fuel itself (e.g., changes in temperature, evolved gases) that are encoded as the frequency and/or amplitude of the radiated sound [IEEE Measurement and Instrumen- tation 16(3), 18-25 (2013)]. For such acoustic information to be detectable, it is important to characterize the vibroacoustical environments within reactors. Measurements will be presented of the background noise spectra (with and with- out coolant pumps) and reverberation times within the 70,000 gallon pool that cools and shields the fuel in the 1 MW research reactor on Penn State's campus using two hydrophones, a piezoelectric projector, and an accelerometer. Sev- eral signal-processing techniques will be demonstrated to enhance the measured results. Background vibrational measurement were also taken at the 250 MW Advanced Test Reactor, located at the Idaho National Laboratory, using ac- celerometers mounted outside the reactor's pressure vessel and on plumbing will also be presented. The detectability predictions made in the thesis were validated in September 2015 using a nuclear ssion-heated thermoacoustic sensor that was placed in the core of the Breazeale Nuclear Reactor on Penn State's campus. Some features of the thermoacoustic device used in that experiment will also be revealed. [Work supported by the U.S. Department of Energy.]

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Long-term stabilization of a heterodyne metrology interferometer down to a noise level of 20 pm over an hour

A heterodyne metrology interferometer was stabilized down to a noise level of 20 picometers (pm) as a root-mean-square (RMS) value integrated between 0.3 mHz and 1 Hz. This noise level was achieved by employing active and passive interferometer stabilization techniques. The heterodyne interferometer was built on a 50 mm square ultralow expansion glass plate in order to reduce an optical path length change caused by temperature variation. An optical configuration of the interferometer is a Mach-Zehnder interferometer with a design as symmetric as possible so that a detection signal can be insensitive to homogeneous thermal expansion of the glass plate. The heterodyne frequency is actively controlled in order to suppress residual noises caused by optical path length changes outside of the glass plate as well as phase fluctuations of the heterodyne frequency source. Our stabilization scheme is considered useful in achieving the 20 pm noise level without a stable heterodyne frequency source, as well as temperature stabilization around a whole apparatus. This interferometer can be used in precise metrology applications, such as characterization of deformation for satellite optical components against thermal exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Neutron Based Scanner to Detect Explosives in Small, Sealed Containers

A scanning system has been designed for portal protection applications, with the capability of detecting explosive materials after an initial scan of 30 seconds. The scanner operates using the principle of neutron induced return gamma-ray spectrometry. This system utilizes high purity germanium detectors, a neutron generator based on deuterium-tritium fusion and a unique neutron reflector and guide design. The neutron reflector amplifies the flux and alters the energy spectrum of neutrons produced by the generator. A depleted uranium reflector is shown to perform 7.3 times better than no reflector, and is found to perform 1.5 times better than a tungsten reflector using MCNP simulation. This improvement is due to neutron knockout and induced fission occurring in depleted uranium. The system is capable of detecting 300 g of explosives with 90% detection probability, which includes a 15% rescan rate after a 30 second initial scan.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Studies Of An Exotic Decay Mode At The Proton Drip-Line: The Two-Proton Radioactivity

Two-proton radioactivity is an exotic decay mode for very proton-rich nuclei. It was observed experimentally for the first time in 2002 for the nucleus {sup 45}Fe but the two protons could not be directly detected. So a new detector has been developed, a Time Projection Chamber, to individually observe the two protons emitted. It was used successfully during two experiments for the study of {sup 45}Fe and {sup 54}Zn. Energy correlations have been studied and the relative angle between the two protons is calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗