Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

The perspective awareness model - Eliciting multiple perspectives to formulate high quality decisions

A great deal of attention is given to the importance of communication in environmental remediation and radioactive waste management. However, very little attention is given to eliciting multiple perspectives so as to formulate high quality decisions. Plans that are based on a limited number of perspectives tend to be narrowly focused whereas those that are based on a wide variety of perspectives tend to be comprehensive, higher quality, and more apt to be put into application. In addition, existing methods of dialogue have built-in limitations in that they typically draw from the predominant thinking patterns which focus in some areas but ignore others. This can result in clarity but a lack of comprehensiveness. This paper presents a Perspective Awareness Model which helps groups such as partnering teams, interagency teams, steering committees, and working groups elicit a wide net of perspectives and viewpoints. The paper begins by describing five factors that makes cooperation among such groups challenging. Next, a Perspective Awareness Model that makes it possible to manage these five factors is presented. The two primary components of this model --- the eight 'Thinking Directions' and the 'Shared Documentation' --- are described in detail. Several examples are given to illustrate how the Perspective Awareness Model can be used to elicit multiple perspectives to formulate high quality decisions in the area of environmental remediation and radioactive waste management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulations of the propagation of multiple-FM smoothing by spectral dispersion on OMEGA EP

A one-dimensional (1-D) smoothing by spectral dispersion (SSD) system for smoothing focal-spot nonuniformities using multiple modulation frequencies has been commissioned on one long-pulse beamline of OMEGA EP, the first use of such a system in a high-energy laser. Frequency modulation (FM) to amplitude modulation (AM) conversion in the infrared (IR) output, frequency conversion, and final optics affected the accumulation of B-integral in that beamline. Modeling of this FM-to-AM conversion using the code Miró. was used as input to set the beamline performance limits for picket (short) pulses with multi-FM SSD applied. This article first describes that modeling. The 1-D SSD analytical model of Chuang is first extended to the case of multiple modulators and then used to benchmark Miró simulations. Comparison is also made to an alternative analytic model developed by Hocquet et al. With the confidence engendered by this benchmarking, Miró results for multi-FM SSD applied on OMEGA EP are then presented. The relevant output section(s) of the OMEGA EP Laser System are described. The additional B-integral in OMEGA EP IR components upstream of the frequency converters due to AM is modeled. The importance of locating the image of the SSD dispersion grating at the frequency converters is demonstrated. In conclusion, since frequency conversion is not performed in OMEGA EP’s target chamber, the additional AM due to propagation to the target chamber’s vacuum window is modeled.

36 MATERIALS SCIENCE↗

Combining multiple FDG-PET radiotherapy target segmentation methods to reduce the effect of variable performance of individual segmentation methods

Purpose: Many approaches have been proposed to segment high uptake objects in 18F-fluoro-deoxy-glucose positron emission tomography images but none provides consistent performance across the large variety of imaging situations. This study investigates the use of two methods of combining individual segmentation methods to reduce the impact of inconsistent performance of the individual methods: simple majority voting and probabilistic estimation. Methods: The National Electrical Manufacturers Association image quality phantom containing five glass spheres with diameters 13-37 mm and two irregularly shaped volumes (16 and 32 cc) formed by deforming high-density polyethylene bottles in a hot water bath were filled with 18-fluoro-deoxyglucose and iodine contrast agent. Repeated 5-min positron emission tomography (PET) images were acquired at 4:1 and 8:1 object-to-background contrasts for spherical objects and 4.5:1 and 9:1 for irregular objects. Five individual methods were used to segment each object: 40% thresholding, adaptive thresholding, k-means clustering, seeded region-growing, and a gradient based method. Volumes were combined using a majority vote (MJV) or Simultaneous Truth And Performance Level Estimate (STAPLE) method. Accuracy of segmentations relative to CT ground truth volumes were assessed using the Dice similarity coefficient (DSC) and the symmetric mean absolute surface distances (SMASDs). Results: MJV had median DSC values of 0.886 and 0.875; and SMASD of 0.52 and 0.71 mm for spheres and irregular shapes, respectively. STAPLE provided similar results with median DSC of 0.886 and 0.871; and median SMASD of 0.50 and 0.72 mm for spheres and irregular shapes, respectively. STAPLE had significantly higher DSC and lower SMASD values than MJV for spheres (DSC, p < 0.0001; SMASD, p= 0.0101) but MJV had significantly higher DSC and lower SMASD values compared to STAPLE for irregular shapes (DSC, p < 0.0001; SMASD, p= 0.0027). DSC was not significantly different between 128 Multiplication-Sign 128 and 256 Multiplication-Sign 256 grid sizes for either method (MJV, p= 0.0519; STAPLE, p= 0.5672) but was for SMASD values (MJV, p < 0.0001; STAPLE, p= 0.0164). The best individual method varied depending on object characteristics. However, both MJV and STAPLE provided essentially equivalent accuracy to using the best independent method in every situation, with mean differences in DSC of 0.01-0.03, and 0.05-0.12 mm for SMASD. Conclusions: Combining segmentations offers a robust approach to object segmentation in PET. Both MJV and STAPLE improved accuracy and were robust against the widely varying performance of individual segmentation methods. Differences between MJV and STAPLE are such that either offers good performance when combining volumes. Neither method requires a training dataset but MJV is simpler to interpret, easy to implement and fast.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-06: Online Adaptive Re-Planning to Account for Independent Motions Between Multiple Targets During Radiotherapy of Lung Cancer

Purpose: To quantify interfractional independent motions between multiple targets in radiotherapy (RT) of lung cancer, and to study the dosimetric benefits of an online adaptive replanning method to account for these variations. Methods: Ninety five diagnostic-quality daily CTs acquired for 9 lung cancer patients treated with IGRT using an in-room CT (CTVision, Siemens) were analyzed. On each daily CT set, contours of the targets (GTV, CTV, or involved nodes) and organs at risk were generated by populating the planning contours using an auto-segmentation tool (ABAS, Elekta) with manual editing. For each patient, an IMRT plan was generated based on the planning CT with a prescription dose of 60 Gy in 2Gy fractions. Three plans were generated and compared for each daily CT set: an IGRT (repositioning) plan by copying the original plan with the required shifts, an online adaptive plan by rapidly modifying the aperture shapes and segment weights of the original plan to conform to the daily anatomy, and a new fully re-optimized plan based on the daily CT using a planning system (Panther, Prowess). Results: The daily deviations of the distance between centers of masses of the targets from the plans varied daily from -10 to 8 mm with an average −0.9±4.1 mm (one standard deviation). The average CTV V100 are 99.0±0.7%, 97.9±2.8%, 99.0±0.6%, and 99.1±0.6%, and the lung V20 Gy 928±332 cc, 944±315 cc, 917±300 cc, and 891±295 cc for the original, repositioning, adaptive, and re-optimized plans, respectively. Wilcoxon signed-rank tests show that the adaptive plans are statistically significantly better than the repositioning plans and comparable with the reoptimized plans. Conclusion: There exist unpredictable, interfractional, relative volume changes and independent motions between multiple targets during lung cancer RT which cannot be accounted for by the current IGRT repositioning but can be corrected by the online adaptive replanning method.

60 APPLIED LIFE SCIENCES↗

TU-A-18A-01: Basic Principles of PET/CT, Calibration Methods and Contrast Recovery Across Multiple Cameras

This continuing education session will discuss the physical principles of PET/CT imaging and characterization of contrast recovery using accreditation phantoms. A detailed overview will be given on the physical principles of PET including positron decay physics, 2D and 3D data acquisition, time-of-flight, scatter correction, CT attenuation correction, and image reconstruction. Instrument quality control and calibration procedures will be discussed. Technical challenges, common image artifacts and strategies to mitigate these issues will also be discussed. Data will be presented on acquisition techniques and reconstruction parameters affecting contrast recovery. The discussion will emphasize the minimization of reconstruction differences in quantification metrics such as SUV and contrast recovery coefficients for the NEMA and ACR clinical trial phantoms. Data from new and older generation scanners will be shown including comparison of contrast recovery measurements to their analytical solutions. The goal of this session is to update attendees on the quality control and calibration of PET/CT scanners, on methods to establish a common calibration for PET/CT scanners to control for instrument variance across multiple sites. Learning Objectives: Review the physical principles of PET/CT, quality control and calibration Gain further understanding on how to apply techniques for improving quantitative agreement across multiple cameras Describe the differences between measured and expected contrast recovery for the NEMA and ACR PET phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 64: Preliminary investigation of arc configurations for optimal sparing of normal tissue in hypofractionated stereotactic radiotherapy (HF-SRT) of multiple brain metastases using a 5mm interdigitating micro-multileaf collimator

Purpose: To evaluate normal tissue sparing in intra-cranial HF-SRT, comparing various arc configurations with the Synergy Beam Modulator (SynBM) and Agility linacs, the latter incorporating leaf interdigitation and backup jaws. Methods: Five patients with multiple brain metastases (BMs), (5 BMs (n=2), 3 BMs (n=3)) treated with HF-SRT using 25 Gy (n=2) or 30 Gy (n=3) in 5 fractions, were investigated. Clinical treatment plans used the SynBM. Each patient was retrospectively re-planned on Agility, employing three planning strategies: (A) one isocenter and dedicated arc for each BM; (B) a single isocenter, centrally placed with respect to BMs; (C) the isocenter and arc configuration used in the SynBM plan, where closely spaced (<5cm) BMs used a dedicated isocenter and arcs. Agility plans were normalized for PTV coverage and heterogeneity. Results and Conclusion: Strategy A obtained the greatest improvements over the SynBM plan, where the maximum OAR dose, and mean dose to normal brain (averaged for all patients) were reduced by 55cGy and 25cGy, respectively. Strategy B was limited by having a single isocenter, hence less jaw shielding and increased MLC leakage. The maximum OAR dose was reduced by 13cGy, however mean dose to normal brain increased by 84cGy. Strategy C reduced the maximum OAR dose and mean dose to normal brain by 32cGy and 9cGy, respectively. The results from this study indicate that, for intra-cranial HF-SRT of multiple BMs, Agility plans are equal or better than SynBM plans. Further planning is needed to investigate dose sparing using Strategy A and the SynBM.

60 APPLIED LIFE SCIENCES↗

SU-E-J-101: Improved CT to CBCT Deformable Registration Accuracy by Incorporating Multiple CBCTs

Purpose: Combining prior day CBCT contours with STAPLE was previously shown to improve automated prostate contouring. These accurate STAPLE contours are now used to guide the planning CT to pre-treatment CBCT deformable registration. Methods: Six IGRT prostate patients with daily kilovoltage CBCT had their original planning CT and 9 CBCTs contoured by the same physician. These physician contours for the planning CT and each prior CBCT are deformed to match the current CBCT anatomy, producing multiple contour sets. These sets are then combined using STAPLE into one optimal set (e.g. for day 3 CBCT, combine contours produced using the plan plus day 1 and 2 CBCTs). STAPLE computes a probabilistic estimate of the true contour from this collection of contours by maximizing sensitivity and specificity. The deformation field from planning CT to CBCT registration is then refined by matching its deformed contours to the STAPLE contours. ADMIRE (Elekta Inc.) was used for this. The refinement does not force perfect agreement of the contours, typically Dice’s Coefficient (DC) of > 0.9 is obtained, and the image difference metric remains in the optimization of the deformable registration. Results: The average DC between physician delineated CBCT contours and deformed planning CT contours for the bladder, rectum and prostate was 0.80, 0.79 and 0.75, respectively. The accuracy significantly improved to 0.89, 0.84 and 0.84 (P<0.001 for all) when using the refined deformation field. The average time to run STAPLE with five scans and refine the planning CT deformation was 66 seconds on a Telsa K20c GPU. Conclusion: Accurate contours generated from multiple CBCTs provided guidance for CT to CBCT deformable registration, significantly improving registration accuracy as measured by contour DC. A more accurate deformation field is now available for transferring dose or electron density to the CBCT for adaptive planning. Research grant from Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-T-52: A New Device for Quality Assurance of a Single Isocenter Technique for the Simultaneous Treatment of Multiple Brain Metastases

Purpose: Comprehensive quality assurance (QA) of a single isocenter technique for the simultaneous treatment of multiple brain metastases is presently impractical due to the time consuming nature of measuring each lesion’s dose on film or with a micro-chamber. Three dimensional diode array and full field film measurements are sometimes used to evaluate these plans, but gamma analysis may not reveal local errors that have significant effects on one or a few of several targets. This work aimed to design, build and test a phantom to simplify comprehensive measurement and evaluation. Methods: A phantom was designed with 28 stackable slabs. The top and bottom slabs are 1.5 centimeters (cm) in thickness, and central 26 slabs are 0.5 cm thick. When assembled with radiochromic film in all 27 gaps, the phantom measures 16.5 x 15 x 19 cm. Etchings were designed to aide in identification of specific film planes on computed tomography (CT) images and correlation of individual PTVs with closest bisecting planes. Patient verification plans with a total of 16 PTVs were calculated on the phantom CT, and test deliveries both with and without couch kicks were performed to test the ability to identify correct film placements and subsequent PTV specific dose distributions on the films. Results: Bisecting planes corresponding to PTV locations were easily identified, and PTV specific dose distributions were clear for all 16 targets. For deliveries with couch kicks, the phantom PTV dose distributions closely approximated those calculated on the patient’s CT. For deliveries without couch kicks, PTV specific dosimetry was also possible, although the distributions had ‘ghosts’ equaling the number of couch kicks, with distance between ghosts increasing with distance from the isocenter. Conclusion: A new phantom facilitates fast comprehensive commissioning validation and PTV specific dosimetry for a single isocenter technique for treating multiple brain metastases. This work was partially funded by CIRS, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-306: Dosimetric Comparison of Leaf with Or Without Interdigitation in Multiple Brain Metastasis VMAT Treatment Planning

Purpose: To evaluate the effects of leaf with or without interdigitation in multiple brain metastasis volumetric modulated arc therapy (VMAT) plans. Methods: Twenty patients with 2 to 6 brain metastases of our hospital were retrospectively studied to be planned with dual arc VMAT using Monaco 3.3 TPS on the Elekta Synergy linear accelerator. The prescription dose of PTV was 60Gy/30 fractions. Two plans with or without leaf interdigitation were designed. The homogeneity index (HI), conformity index (CI), dose volume histograms (DVHs), monitor unit (MU), treatment time (T), the segments, the dose coverage of the target, were all evaluated. Results: The plans with leaf interdigitation could achieve better CI (p<0.05) than without leaf interdigitation, while no significant difference were found in HI (p> 0.05) and the dose coverage of the target (p> 0.05).The MU,T, and the segments of the plan with leaf interdigitation were more than the plan without leaf interdigitation (p<0.05). There was no significant difference found in radiation dose of spinal cord, lenses and parotids, while the maximum dose of brain stem of leaf without interdigitation was higher than leaf with interdigitation (p< 0.05). It was worth noting that the areas of low dose regions with leaf interdigitation plan were much less than the without leaf interdigitation plan in the doublication planes (p< 0.05). Conclusion: This study shows that leaf with interdigitation has some advantages than leaf without interdigitation in multiple brain metastasis VMAT plans although the clinical relevance remains to be proven.

60 APPLIED LIFE SCIENCES↗

SU-E-T-799: Verification of a Simultaneous Treatment of Multiple Brain Metastases Using VMAT Technique by a Composite Alanine-Gel Dosimeter Phantom

Purpose: This work presents an end-to-end test using a Gel-Alanine phantom to validate the three-dimensional (3D) dose distribution (DD) delivered by a single isocenter VMAT technique on the simultaneous treatment of multiple brain metastases. Methods: Three cylindrical phantons containing MAGIC-f gel dosimeter were used to measure the 3D DD of a VMAT treatment, the first two were filled with the gel dosimeter (Gel 1 and 2) and the third one was filled with gel and 12 alanine dosimeters distributed along it (Gel 3). Gels 1 and 3 were irradiated and gel 2 was used to map the magnetic resonance image (MRI) scanner field inomogeneities. A CT scan of gel 3 was used for the VMAT treatment planning and 5 alanine pellets were chosen as lesions, around them a PTV was grown and different dose prescriptions were assigned for each one, varying from 5 to 9Gy. Before treatment, the plan was approved in a QA based on an ionization chamber absolute dose measurement, a radiochromic film planar dose measurement and a portal dosimetry per field verification; and also the phantons positioning were verified by ExacTrac 6D correction and OBI kV Cone Beam CT. The gels were irradiated, the MRIs were acquired 24 hours after irradiation and finally, the alanine dosimeters were analysed in a X-band Electron Spin Resonance spectrometer. Results: The association of the two detectors enabled the 3D dose evaluation by gel and punctually inside target volumes by alanine. In the gamma analyses (3%/3mm) comparing the 5 PTVs’ central images DD with TPS expected DD more than 95% of the points were approved. The alanine absolute dose measurements were in agreement with TPS by less than 5%. Conclusion: The gel-alanine phantom enabled the dosimetric validation of multiple brain metastases treatment using VMAT, being an almost ideal tool for this application. This work is partially supported by FAPESP.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-01: Radiosurgery of Multiple Brain Metastases with Single-Isocenter VMAT: Optimizing Treatment Geometry to Reduce Normal Brain Dose

Purpose: To develop an optimization algorithm to reduce normal brain dose by optimizing couch and collimator angles for single isocenter multiple targets treatment of stereotactic radiosurgery. Methods: Three metastatic brain lesions were retrospectively planned using single-isocenter volumetric modulated arc therapy (VMAT). Three matrices were developed to calculate the projection of each lesion on Beam’s Eye View (BEV) by the rotating couch, collimator and gantry respectively. The island blocking problem was addressed by computing the total area of open space between any two lesions with shared MLC leaf pairs. The couch and collimator angles resulting in the smallest open areas were the optimized angles for each treatment arc. Two treatment plans with and without couch and collimator angle optimization were developed using the same objective functions and to achieve 99% of each target volume receiving full prescription dose of 18Gy. Plan quality was evaluated by calculating each target’s Conformity Index (CI), Gradient Index (GI), and Homogeneity index (HI), and absolute volume of normal brain V8Gy, V10Gy, V12Gy, and V14Gy. Results: Using the new couch/collimator optimization strategy, dose to normal brain tissue was reduced substantially. V8, V10, V12, and V14 decreased by 2.3%, 3.6%, 3.5%, and 6%, respectively. There were no significant differences in the conformity index, gradient index, and homogeneity index between two treatment plans with and without the new optimization algorithm. Conclusion: We have developed a solution to the island blocking problem in delivering radiation to multiple brain metastases with shared isocenter. Significant reduction in dose to normal brain was achieved by using optimal couch and collimator angles that minimize total area of open space between any of the two lesions with shared MLC leaf pairs. This technique has been integrated into Eclipse treatment system using scripting API.

60 APPLIED LIFE SCIENCES↗

SU-C-207A-06: On-Line Beam Range Verification with Multiple Scanning Particle Beams: Initial Feasibility Study with Simulations

Purpose: To investigate the feasibility and requirement for intra-fraction on-line multiple scanning particle beam range verifications (BRVs) with in-situ PET imaging, which is beyond the current single-beam BRV with extra factors that will affect the BR measurement accuracy, such as beam diameter, separation between beams, and different image counts at different BRV positions. Methods: We simulated a 110-MeV proton beam with 5-mm diameter irradiating a uniform PMMA phantom by GATE simulation, which generated nuclear interaction-induced positrons. In this preliminary study, we simply duplicated these positrons and placed them next to the initial protons to approximately mimic the two spatially separated positron distributions produced by two beams parallel to each other but with different beam ranges. These positrons were then imaged by a PET (∼2-mm resolution, 10% sensitivity, 320×320×128 mm^3 FOV) with different acquisition times. We calculated the positron activity ranges (ARs) from reconstructed PET images and compared them with the corresponding ARs of original positron distributions. Results: Without further image data processing and correction, the preliminary study show the errors between the measured and original ARs varied from 0.2 mm to 2.3 mm as center-to-center separations and range differences were in the range of 8–12 mm and 2–8 mm respectively, indicating the accuracy of AR measurement strongly depends on the beam separations and range differences. In addition, it is feasible to achieve ≤ 1.0-mm accuracy for both beams with 1-min PET acquisition and 12 mm beam separation. Conclusion: This study shows that the overlap between the positron distributions from multiple scanning beams can significantly impact the accuracy of BRVs of distributed particle beams and need to be further addressed beyond the established method of single-beam BRV, but it also indicates the feasibility to achieve accurate on-line multi-beam BRV with further improved method.

60 APPLIED LIFE SCIENCES↗

SU-F-T-495: Method for Simultaneous Commissioning of Multiple Truebeam (TB) Linacs: Small Field Data and the Choice of Dosimetric Lead Gap (DLG)

Purpose: Many times a set of multiple Varian-Truebeam (TB) linacs are acquired by an institution. Since “beam matching” is an important requirement for many facilities, we developed a strategy to perform a “simultaneous” commissioning between multiple linacs.Methods and Materials: We first commissioned the required photon beam data for eclipse on the 1st TB for all the energy modalities with a beam scanning system, while integrated measurements for output factors, of all field sizes (from 1×1 to 40×40cm{sup 2}) were conducted on the 2nd TB. Care was exercised during small field dosimetry so the appropriate detectors were used with data taken between two detectors be “linked” to a larger field size (4×4cm{sup 2}) with the “daisy-chaining” technique via: OF=[M-PTW(fs)×(M-PTW(4×4))-1]×[MA12s(4×4)×(M-A12S(10×10))−1]. For all energy modalities, data that span the entire range of field size, was repeated on the next TB linac, for verification. The primarily energy-dependent dosimetric leaf gap (DLG) which was measured separately on each TB. The modeled data was validated with special measurements conducted on both linacs during commissioning. Results: Our data agreed with the “TB representative beam data” to within 0.5% for all energy modalities and field sizes ≥3×3cm2. Sample depth-doses and cross-profiles of a 3×3cm2 between the linacs agreeing to within 1% between linacs. The measured DLGs were quite different with a uniform difference of 1.3% between the two linacs. The measured DLG values are independent of the average dose rate and medium used for the measurements. Conclusion: A comprehensive method of commissioning identical Varian-TB linacs, outlining the critical issues, especially small field dosimetry and DLG. The dosimetric effect of different DLG values, when it comes to, dynamic delivery and data comparisons will be presented. The dependence of DLG value on the measurement medium (in-air vs. water) or dose rate used will also be discussed. This work was supported by CAMC Cancer Center and Alliance Oncology.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-510: Single Isocenter Radiosurgery for the Simultaneous Treatment of Multiple Brain Metastases: Volumetric Modulated Arc Therapy Or Dynamic Conformal Arc?

Purpose: This study evaluates a novel algorithm that can be used with any treatment planning system for simple and rapid generation of stereotactic radiosurgery (SRS) plans for treating multiple brain metastases using a single isocenter dynamic conformal arc (DCA) approach. This technique is compared with a single isocenter volumetric modulated arc therapy (VMAT) technique in terms of delivery time, conformity, low dose spread and delivery accuracy. Methods: Five patients, with a total of 37 (5 – 11) targets were planned using a previously published method for generating optimal VMAT plans and using the proposed DCA algorithm. All planning target volumes (PTVs) were planned to 20 Gy, meeting a minimum 99% coverage and maximum 135 % hot spot for both techniques. Quality assurance was performed using radiochromic film, with films placed in the high dose regions of each PTV. Normal tissue volumes receiving 12 Gy and 6 Gy (V12 and V6) were computed for each plan. Conformity index (CI) and gamma evaluations (95% of points passing 4%/0.5mm) were computed for each PTV. Results: Delivery times, including beam on and table rotation times, were comparable: 17 – 22 minutes for all deliveries. V12s for DCA plans were (18.5±15.2 cc) vs. VMAT (19.7±14.4 cc). V6s were significantly lower for DCA (69.0±52.0 cc) compared with VMAT (154.0±91.0 cc) (p <<0.05). CIs for VMAT targets were (1.38±0.50) vs. DCA (1.61±0.41). 36 of 37 DCA planned targets passed gamma tests, while 29 of 37 VMAT planned targets passed. Conclusion: Single isocenter DCA plans were easily achieved. The evaluation suggests that DCA may represent a favorable technique compared with VMAT for multiple target SRS by reducing dose to normal tissue and more accurately depicting deliverable dose.

60 APPLIED LIFE SCIENCES↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-05: Conundrum for VMAT Cranial Multiple Lesions Treated with HD120 MLC

Purpose: To commission a custom 6MV-SRS-AAA Eclipse beam model for VMAT multiple lesions cranial SRS treatment on a Varian TrueBeam STx. Methods: Six clinical plans were created using a customized beam model with dosimetric-leaf-gap(DLG) optimized for clinical treatments. Each plan had 4–6 non-isocentric targets with size from 0.2 to 7.1cc. All fields were measured with EBT3 film in the coronal plane in a solid water phantom and with an AS1000 EPID using gantry rotation. In addition, an end-to-end test was performed with coronal and sagittal films in an anthropomorphic phantom verifying dosimetry and localization accuracy. Portal dose distributions were generated with a custom portal dosimetry algorithm(PDIP). Measured dose distributions were compared with calculations using average dose difference (DD), and gamma function, γ. Using a 1.25mm grid, the γ criteria, local DD ≤ 3% and 2mm distance-to-agreement, were applied in regions with dose 50% of maximum. Results: The respective DD and γ for all films were <±2% and >94.2%. The portal dose γ scores for all the plans were >94.9%. However, local regions with underdose >10%, were observed when targets were treated with the 5mm leaves. The same plans re-optimized with two isocenters such that all lesions were under the 2.5mm leaves did not show this effect. The DD and localization error of the end-to-end test were within 3.4% and 1.0mm respectively. Conclusion: The custom AAA beam model is capable of calculating acceptable dosimetry for targets using only the 2.5 mm leaves. This restricts lesions to within ±4cm of isocenter. The observed underdose beneath the 5mm leaves is attributed to a limitation in Eclipse that uses a single DLG representing the DLG’s of both 2.5mm and 5mm leaves. If lesions are >4cm from isocenter, a multiple isocenter technique should be considered to allow the use of only the 2.5mm leaves.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-06: Evaluation of a Novel Radiosurgery Software for Treating Multiple Brain Metastases Simultaneously in a Single Fraction

Purpose: To evaluate a new, automated brain metastases planning software designed to treat up to ten brain metastases simultaneously. Methods: We treated 61 patients with multiple brain metastases using the Elements software by BrainLab (Munich, Germany). Patients had between 2–10 metastases ranging from 0.01–8.64 cc. Dose prescription was 18–24 Gy. Plans use up to 5 non-coplanar arcs with a single isocenter at the metastases’ center of mass. The high degree of automation shortens the planning time to 15–20 minutes per patient.For comparison we planned 21 of the patients using Rapid Arc (Varian, Palo Alto CA) (RA). We used two coplanar arcs so as to keep planning times comparable to the Elements. We also planned 8 patients using iPlan software (BrainLab). We compared conformity index (CI), volume of brain receiving over 12 Gy (V{sub 12}) and mean brain dose (MBD) for the three different planning systems (TPSs). Results: Plans from all TPSs were judged clinically acceptable. V{sub 12} and MBD were not statistically significantly different between TPSs.CI between RA and Elements was similar, however for iPlan CI was significantly worse compared to both RA and Elements (p<0.001). RA plans took approximately 40 minutes to plan (despite fusion and contouring being done in the Elements), and iPlan plans over an hour each. Delivery times were approximately 30 minutes for Elements, 10 minutes for RA, and up to 300 minutes for iPlan. Conclusion: Elements plans had good CI values and low brain doses. While treatment times for Elements were longer than for RA, 30 minutes is a significant improvement over conventional radiosurgery techniques where each metastasis is treated individually and delivery times to 10 metastases are close to 300 minutes.BrainLab Elements is a novel software allowing fast, automated planning and efficient irradiation of multiple brain metastases with minimal dose to healthy brain.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

60 APPLIED LIFE SCIENCES↗