At least 955 records · Page 53

Effects of the Electron Beam Welding Process on the Microstructure, Tensile, Fatigue and Fracture Properties of Nickel Alloy Nimonic 80A

The purpose of this study was to evaluate rotary bending high-cycle fatigue properties and crack growth of Nimonic 80A-based metal and electron beam-welded joints. All the tests were performed at room temperature. Fracture surfaces under high-cycle fatigue and fatigue crack growth were observed by scanning electron microscopy. Microstructure, hardness and tensile properties were also evaluated in order to understand the effects on the fatigue results obtained. It was found that the tensile properties, hardness and high-cycle fatigue properties of the welded joint are lower than the base metal. The fracture surface of the high-cycle fatigue shows that fatigue crack initiated from the surface under the high stress amplitude and from the subsurface under the low stress amplitude. The effect of the welding process on the statistical fatigue data was studied with a special focus on probabilistic life prediction and probabilistic lifetime limits. The fatigue crack growth rate versus stress intensity factor range data were obtained from the fatigue crack growth tests. From the results, it was evident that the fatigue crack growth rates of the welded are higher than the base metal. The mechanisms and fracture modes of fatigue crack growth of welded specimens were found to be related to the stress intensity factor range ΔK. In addition, the effective fatigue crack propagation thresholds and mismatch of welded joints were described and discussed.

36 MATERIALS SCIENCE↗

Stress Wave Attenuation in Aluminum Alloy and Mild Steel Specimens Under SHPB Tensile Testing

Investigations on the effect of intensity of incident pressure wave applied through the striker bar on the specimen force histories and stress wave attenuation during split Hopkinson pressure bar (SHPB) tensile testing are presented. Details of the tensile SHPB along with Lagrangian x–t diagram of the setup are included. Studies were carried out on aluminum alloy 7075 T651 and IS 2062 mild steel. While testing specimens using the tensile SHPB setup, it was observed that the force calculated from the transmitter bar strain gauge was smaller than the force obtained from the incident bar strain gauge. This mismatch between the forces in the incident bar and the transmitter bar is explained on the basis of stress wave attenuation in the specimens. A methodology to obtain force histories using the strain gauges on the specimen during SHPB tensile testing is also presented. Further, scanning electron microscope images and photomicrographs are given. Correlation between the microstructure and mechanical properties is explained. Further, uncertainty analysis was conducted to ascertain the accuracy of the results.

36 MATERIALS SCIENCE↗

High-Temperature Mechanical Properties of the P/M Extruded Mg-SiC{sub p} Composites

In the present study, pure magnesium reinforced with 0, 5, 10 and 15 vol.% SiC particulates was successfully prepared by powder metallurgy technique before being hot extruded. The average 14 μm grain size of the composite specimens remained almost unchanged after addition of SiC particles, while their dimensional stability was improved because of the reduction in the coefficient of thermal expansion (CTE) from 28.6 × 10{sup −6} K{sup −1} in pure Mg to 27.3, 25.3 and 23.4 × 10{sup −6} K{sup −1} in the Mg-5% SiC, Mg-10% SiC and Mg-15% SiC composites, respectively. Mechanical properties of the specimens were investigated in the temperature range of 298-498 K, implementing shear punch testing and hot hardness techniques. Depending on the test temperature, addition of SiC particles to the pure Mg matrix increased shear yield stress and ultimate shear strength of the materials by 5-25 and 6-23 MPa, respectively. The shear strength improvement was mainly attributed to the CTE mismatch strengthening mechanism (9.5-25.5 MPa), and to a lesser extent (1-4.5 MPa), to the load transfer mechanism. Finally, using the modified Clyne model, the contribution of different strengthening mechanisms to the total shear strength improvement in the composites was evaluated.

36 MATERIALS SCIENCE↗

Development of Graphene Nanoplatelet-Reinforced AZ91 Magnesium Alloy by Solidification Processing

It is a challenging task to effectively incorporate graphene nanoplatelets (GNPs) which have recently emerged as potential reinforcement for strengthening metals into magnesium-based matrices by conventional solidification processes due to their large surface areas and poor wettability. A solidification processing which combines mechanical stirring and ultrasonic dispersion of reinforcements in liquid matrix was employed to develop AZ91 magnesium alloy matrix composites reinforced with 0.25 and 0.5 wt.% GNPs. The microstructural studies conducted with scanning and transmission electron microscopes revealed that fairly uniform distribution and dispersion of GNPs through the matrix were achieved due to effective combination of mechanical and ultrasonic stirring. The GNPs embedded into the magnesium matrix led to significant enhancement in the hardness, tensile strength and ductility of the composites compared to those of unreinforced AZ91 alloy. The strength enhancement was predominantly attributed to the grain refinement by the GNP addition and dislocation generation strengthening due to the coefficient of thermal expansion mismatch between the matrix and reinforcement. The improved ductility was attributed to the refinement of β eutectics by transforming from lamellar to the divorced eutectics due to the GNP additions. In addition, the strengthening efficiency of the composite with 0.25 wt.% GNP was found to be higher than those of the composite with 0.5 wt.% GNP as the agglomeration tendency of GNPs is increased with increasing GNP content. These results were compared with those of the GNP-reinforced magnesium composites reported in the literature, indicating the potential of the process introduced in this study in terms of fabricating light and high-performance metal matrix composites.

36 MATERIALS SCIENCE↗

Impact Behavior of Polyetheretherketone/Nickel Foam Co-continuous Composites

In this study, we prepared eight types of polyetheretherketone/nickel (PEEK/Ni) foam co-continuous phase composites (named “PEEK-Nis”) in which virgin PEEK was infiltrated into homologous hollow Ni structures by using hot pressing. Their Charpy impact behavior was investigated in accordance with ISO: 179-1, and the effect of the structure of the foam Ni on the impact properties of the PEEK-Nis was also studied. Compared with unfilled PEEK, the Ni prisms can effectively disperse, transfer, and absorb the energy of the pendulum, further improve the impact toughness of the PEEK-Nis and eventually lead to different fracture modes. The impact toughness of PEEK-Nis was mainly affected by Ni volume fraction, coating thickness, and pores per inch (PPI) value, which are mutually restricted. When the Ni content was less than 8.5%, the impact toughness of PEEK-Nis increased with an increase in PPI value. When the Ni content was between 8.5 and 18%, the impact toughness of PEEK-Nis increased with the coating thickness. When the Ni content exceeded 18%, the impact toughness decreased dramatically possibly because of the mechanical mismatch of the two-phase materials in PEEK-Nis. For further optimization, PEEK-NiB-2 was fabricated and had the most reasonable structure of the reinforcing phase. Among all PEEK-Nis, PEEK-NiB-2 exhibited the best impact toughness, with a value over two times that of unfilled PEEK.

36 MATERIALS SCIENCE↗

Beyond Atomic Sizes and Hume-Rothery Rules: Understanding and Predicting High-Entropy Alloys

High-entropy alloys constitute a new class of materials that provide an excellent combination of strength, ductility, thermal stability, and oxidation resistance. Although they have attracted extensive attention due to their potential applications, little is known about why these compounds are stable or how to predict which combination of elements will form a single phase. Here, we present a review of the latest research done on these alloys focusing on the theoretical models devised during the last decade. We discuss semiempirical methods based on the Hume-Rothery rules and stability criteria based on enthalpies of mixing and size mismatch. To provide insights into the electronic and magnetic properties of high-entropy alloys, we show the results of first-principles calculations of the electronic structure of the disordered solid-solution phase based on both Korringa Kohn Rostoker coherent potential approximation and large supercell models of example face-centered cubic and body-centered cubic systems. Furthermore, we discuss in detail a model based on enthalpy considerations that can predict which elemental combinations are most likely to form a single-phase high-entropy alloy. The enthalpies are evaluated via first-principles high-throughput density functional theory calculations of the energies of formation of binary compounds, and therefore it requires no experimental or empirically derived input. Finally, the model correctly accounts for the specific combinations of metallic elements that are known to form single-phase alloys while rejecting similar combinations that have been tried and shown not to be single phase.

36 MATERIALS SCIENCE↗

Avoiding surface instability and slurry jamming in simultaneous multilayer coating of structured particulate films

Simultaneous multilayer coating techniques are widely known, but their industrial application remains limited to narrow market sectors. One barrier to adoption may be the mismatch between industries that are familiar with such processes but have no need, and industries that have need but are not familiar. Moreover, there are application-specific technical challenges to developing multilayer-coating processes. In this article, we describe our resolution of two specific issues in simultaneous multilayer coating of all aqueous highly loaded slurries for new and emerging energy applications. The first issue is particle jamming (associated with Shear-thickening) of the highly loaded slurries in the die internals, which we alleviated by adding small amounts of viscosity modifiers without reducing the solid loading. The second issue is a Marangoni-driven surface instability that resembles top layer de-wetting, which we solved by carefully selecting surfactants to tune the dynamic surface tensions of each slurry. Both issues were resolved early in a step-wise development, saving significant development cost which in our case was driven by expensive materials.

08 HYDROGEN↗

Geometrical quasi-ballistic effects on thermal transport in nanostructured devices

In this work, we employ thermoreflectance thermal imaging to directly measure the steady-state two-dimensional (2D) temperature field generated by nanostructured heat sources deposited on silicon substrate with different geometrical configurations and characteristic sizes down to 400nm. The analysis of the results using Fourier’s law not only breaks down as size scales down, but it also fails to capture the impact of the geometry of the heat source. The substrate effective Fourier thermal conductivities fitted to wire-shaped and circular-shaped structures with identical characteristic lengths are found to display up to 40% mismatch. Remarkably, a hydrodynamic heat transport model reproduces the observed temperature fields for all device sizes and shapes using just intrinsic Si parameters, i.e., a geometry and size-independent thermal conductivity and nonlocal length scale. The hydrodynamic model provides insight into the observed thermal response and of the contradictory Fourier predictions. We discuss the substantial Silicon hydrodynamic behavior at room temperature and contrast it to InGaAs, which shows less hydrodynamic effects due to dominant phonon-impurity scattering.

42 ENGINEERING↗

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

Aim: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF). Methods: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting {sup 99m}Tc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and {sup 18}F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually. Results: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT. Conclusion: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion

Background: The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Methods and Results: Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of {sup 18}F-fluorodeoxyglucose (FDG) abnormalities were assessed using {sup 99m}Tc-sestamibi and {sup 18}F–FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of {sup 18}F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Conclusions: Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tuning the melting point and phase stability of rare-earth oxides to facilitate their crystal growth from the melt

The challenge of growing rare-earth (RE) sesquioxide crystals can be overcome by tailoring their structural stability and melting point via composition engineering. This work contributes to the advancement of the field of crystal growth of high-entropy oxides. A compound with only small REs (Lu,Y,Ho,Yb,Er) 2 O 3 maintains a cubic C-type structure upon cooling from the melt, as observed via in-situ high-temperature neutron diffraction on aerodynamically levitated samples. On the other hand, a compound with a mixture of small and large REs (Lu,Y,Ho,Nd,La) 2 O 3 crystallizes as a mixture of a primary C-type phase with an unstable secondary phase. Crystals of compositions (Lu,Y,Ho,Nd,La) 2 O 3 and (Lu,Y,Gd,Nd,La) 2 O 3 were grown by the micro-pulling-down (mPD) method with a single monoclinic B-type phase, while a powder of (Lu,Y,Ho,Yb,Er) 2 O 3 did not melt at the maximum operating temperature of an iridium-rhenium crucible. The minimization of the melting point of the two grown crystals is attributed to the mismatch in cation sizes. The electron probe microanalysis reveals that the general element segregation behavior in the crystals depends on the composition.

36 MATERIALS SCIENCE↗

Hybridization of IMC and PID control structures based on filtered GPC using genetic algorithm

Classical and advanced hybridization methods are employed in the control literature to calibrate the tuning parameters of internal model control (IMC) and proportional-integral-derivative (PID) controllers. This paper presents an alternative tuning design for the generalized predictive controller (GPC) that is based on both the positional process model and cost function. The proposed method involves the selection of an integral polynomial weighting filter for reference and output signals to deal with reference tracking, disturbance rejection, model-plant mismatch (MPM), minimum control energy and closed-loop robustness. The filter positional GPC (FP-GPC) obtained is transformed into a two-degree-of-freedom polynomial filtered RST structure and then into filtered internal model control (F-IMC) and PID controllers. Also, a multi-objective optimization based on genetic algorithm is applied to tune the filter parameters. Numerical and experimental essays show the effectiveness of the proposed control methodology.

97 MATHEMATICS AND COMPUTING↗

Sparse approximation of fitting surface by elastic net

The goal of this paper is to develop a computational model and corresponding efficient algorithm for obtaining a sparse representation of the fitting surface to the given scattered data. The basic idea of the model is to utilize the principal shift invariant space and the balanced l{sub 1},l{sub 2} norm minimization (named elastic net). The elastic net can be solved efficiently by an adapted split Bregman iteration algorithm. Numerical experiments indicate that by choosing appropriate regularization parameters, the model can efficiently provide an acceptable compromise between the minimization of the data mismatch term and the sparsity of the solution.

97 MATHEMATICS AND COMPUTING↗

Reducing systematic bias in machine learning applications to J/ψ signal extraction in high-energy nuclear physics

Machine learning techniques are increasingly used in high-energy nuclear physics because they can exploit multivariate correlations more efficiently than conventional cut-based analyses. A central challenge is the construction of training samples that faithfully reproduce the detector response observed in data. Signal samples are usually derived from detector simulations; therefore, mismatches between simulation and data can degrade classifier performance and introduce systematic biases. This work presents two practical correction procedures, namely cumulative distribution function (CDF) mapping and a shift-and-scale transformation, to align simulated signal features with those measured in data. Their performance is demonstrated with $J$/$\psi$ yield measurements in $\sqrt{s_{nn}}$ = 200 GeV Ru+Ru and Zr+Zr collisions recorded by STAR. A set of self-consistency tests shows that these procedures substantially suppress the systematic bias associated with data-simulation discrepancies in machine-learning-based signal extraction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting mesoscale spectral thermal conductivity using advanced deterministic phonon transport techniques

We present a review, demonstration and simulation of phonon transport for the purposes of predicting materials performance at the mesoscale. We focus primarily on the development and implementation of a unified methodology to enable predictive heat transport. We report on the current state of the art as it pertains to deterministic phonon transport methodologies, discussing various topics concerning phonons. In application, we focus on the Self-Adjoint Angular Flux (SAAF) formulation of the Boltzmann transport equation for phonons, and develop the spatial, angular, and material property discretization required to accurately simulate the predictive physics of heat transport in dielectrics. We discuss thermal interfacial resistance and present our formulation of the diffuse mismatch model for simulating phonon interactions at internal boundaries. We have recently developed a deterministic, spectral phonon transport method for predicting effective thermal conductivity ($\kappa_{\textrm{eff}}$), using Bose-Einstein source terms coupled through an average material temperature. In this method, we introduce a closure term to the phonon transport system which acts as a redistribution function for the total energy of the system, and serves as a guide for the amount of non-equilibrium behavior occurring in the system. This method predicts thermal conductivity and equilibrium temperature distributions in homogeneous and heterogeneous materials using data generated by ab initio density functional theory methods. We employ polarization, density of states and full dispersion spectra to resolve thermal conductivity with numerous angular and spatial discretizations. Our implementation utilizes a Richardson iteration on a modified version of the phonon scattering source. The equations associated with this method are solved via a modification of traditional source iteration. We compare the performance of source iteration applied to an existing uncoupled, traditional SAAF method to our new method and comment on the iterative performance of each. We observe ballistic and diffusive phonon scattering as acoustic thickness of the domain changes, and are able to make comparisons between the accuracy and efficiency of both methods.

36 MATERIALS SCIENCE↗

Through-thickness determination of phase composition and residual stresses in thermall barrier coatings using high- energy x-rays.

High-energy X-rays were used to determine the local phase composition and residual stresses through the thickness of as-sprayed and heat-treated plasma-sprayed thermal barrier coatings consisting of a NiCoCrAlY bond coat and an yttria-stabilized zirconia (YSZ) topcoat produced with through-thickness segmentation cracks. The as-sprayed residual stresses reflected the combined influence of quenching stresses from the plasma spray process, thermal expansion mismatch between the topcoat, bond coat and substrate, and stress relief from the segmentation cracks. Heat treatments led to the formation of a thermally grown oxide (TGO) which was in compression in the plane, as well as relief of quenching stresses and development of a stress gradient in the YSZ topcoat. The high-energy X-ray technique used in this study revealed the effects that TGO and segmentation cracks have on the in-plane stress state of the entire coating.

36 MATERIALS SCIENCE↗

Structure of Cr Film Epitaxially Grown on MgO (001)

Cr(001) films of thickness ~100 nm were epitaxially grown on MgO (001) using molecular beam epitaxy at both room temperature and 550 °C. The structure of the films was characterized using high resolution transmission electron microscopy, electron diffraction, and electron energy-loss spectroscopy. Room temperature growth leads to highly oriented columnar structured grains in the film, while growth at 550 °C yields high quality single crystal Cr film, possessing a 45 degree rotational epitaxial relationship between the film and the substrate. For the single crystal film, the interface exhibited coherent regions separated by equally-spaced misfit dislocations. When imaged from the MgO[100]//Cr[110] direction, the dislocation spacing is 5.38 nm and 4.64 nm for the films grown at room temperature and 550 °C, respectively, which is slightly smaller than the expected value of 6.25 nm calculated from the differences in lattice spacing based on known lattice constants. The results presented here indicate that the lattice mismatch between the film and the substrate is accommodated mainly by interface misfit dislocations above some critical thickness. The electronic structure of the interface between the film and the substrate is also explored using electron energy-loss spectroscopy.