Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

The Large Area Pulsed Solar Simulator (LAPSS)

A Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, California, occupies an area measuring about 3 meters wide by 12 meters long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than +/- 2 percent uniformity of irradiance at the test plane and better than +/- 0.3 percent measurement repeatability after warm-up. Glass absorption filters are used to reduce the level of ultraviolet light emitted from the xenon flash lamps. This provides a close match to standard airmass zero and airmass 1.5 spectral irradiance distributions. The 2 millisecond light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices.

Mueller, R. L.↗

Status of a UAV SAR Designed for Repeat Pass Interferometry for Deformation Measurements

Under the NASA ESTO sponsored Instrument Incubator Program we have designed a lightweight, reconfigurable polarimetric L-band SAR designed for repeat pass deformation measurements of rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes. This radar will be installed on an unmanned airborne vehicle (UAV) or a lightweight, high-altitude, and long endurance platform such as the Proteus. After a study of suitable available platforms we selected the Proteus for initial development and testing of the system. We want to control the repeat track capability of the aircraft to be within a 10 m tube to support the repeat deformation capability. We conducted tests with the Proteus using real-time GPS with sub-meter accuracy to see if pilots could fly the aircraft within the desired tube. Our results show that pilots are unable to fly the aircraft with the desired accuracy and therefore an augmented autopilot will be required to meet these objectives. Based on the Proteus flying altitude of 13.7 km (45,000 ft), we are designing a fully polarimetric L-band radar with 80 MHz bandwidth and 16 km range swath. This radar will have an active electronic beam steering antenna to achieve Doppler centroid stability that is necessary for repeat-pass interferometry (RPI). This paper will present are design criteria, current design and expected science applications.

radar↗

Development of a Coherent Doppler Lidar for Precision Maneuvering and Landing of Space Vehicles

A coherent Doppler lidar has been developed to address NASA’s need for a high-performance, compact, and cost-effective velocity and altitude sensor onboard its landing vehicles. Future robotic and manned missions to planetary bodies require precise ground-relative velocity vector and altitude data to execute complex descent maneuvers and safe, soft landing at a pre-designated site. This lidar sensor, referred to as a Navigation Doppler Lidar, meets the required performance of landing missions while complying with vehicle size, mass, and power constraints. Operating from over five kilometers altitude, the lidar obtains velocity and range precision measurements with 2 cm/sec and 2 meters, respectively, dominated by the vehicle motion. After a series of flight tests onboard helicopters and rocket-powered free-flyer vehicles, the Navigation Doppler Lidar is now being ruggedized for future missions to various destinations in the solar system.

Amzaherdian, Farzin↗

Validation of Simplified Load Equations through Loads Measurement and Modeling of a Small Horizontal-Axis Wind Turbine Tower; NREL (National Renewable Energy Laboratory)

As part of an ongoing effort to improve the modeling and prediction of small wind turbine dynamics, NREL tested a small horizontal axis wind turbine in the field at the National Wind Technology Center (NWTC). The test turbine was a 2.1-kW downwind machine mounted on an 18-meter multi-section fiberglass composite tower. The tower was instrumented and monitored for approximately 6 months. The collected data were analyzed to assess the turbine and tower loads and further validate the simplified loads equations from the International Electrotechnical Commission (IEC) 61400-2 design standards. Field-measured loads were also compared to the output of an aeroelastic model of the turbine. Ultimate loads at the tower base were assessed using both the simplified design equations and the aeroelastic model output. The simplified design equations in IEC 61400-2 do not accurately model fatigue loads. In this project, we compared fatigue loads as measured in the field, as predicted by the aeroelastic model, and as calculated using the simplified design equations.

17 WIND ENERGY↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DISTRIBUTION TRANSFORMER ASSET MONITORING ON THE GRID EDGE USING SMART SENSOR DATA

As new loads such as rooftop photovoltaics, electric vehicles and other distributed energy resources become commonplace on the distribution grid, the stress on already aging assets begins to escalate. This increased loading and changing dynamics can exacerbate failure rates. While traditional monitoring efforts focus on transmission and generation assets, utilities are now beginning to pay close attention to distribution assets in order to increase reliability indices and reduce cost from unexpected outages. This research develops low-cost and scalable methods to monitoring the health of a critical distribution grid asset: the service transformer. Existing methods in literature are either invasive and thus difficult to implement or require the device to be tested offline in an expensive lab setting. Data from the ubiquitous smart meter as well as a novel Bluetooth based transformer monitor are leveraged to automatically notify the utility of deteriorating or damaged transformers. Voltage, temperature, and vibration are some of the signals measured and analyzed by the proposed algorithms to predict transformer failures. Furthermore, these algorithms are designed to keep the implementation and processing costs low by taking advantage of edge computing where possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On-Sun Characterization of Microchannel Supercritical Carbon Dioxide Solar Thermal Receivers - Preliminary Findings

The design of, and preliminary on-sun tests on, an 8 cm x 8 cm microchannel supercritical carbon dioxide (sCO2) receiver is presented. The receiver has a laminated design, wherein sheets of Haynes 230 nickel superalloy are patterned and diffusion bonded to form microscale flow passages. The microscale pattern is in the form of square pins with width and height of 500 μm and 200 μm respectively. The pins are arranged in an in-line pattern with respect to the flow direction. The longitudinal and transverse pitch ratios of the micro pin fins are identical and equal to two times the side width of the pillar. A sCO2 test facility is developed with the ability to supply sCO2 at 200 bar pressure and at temperatures between 300-500°C to the receiver inlet. The sCO2 facility is coupled to a seven meter diameter parabolic dish with a 25 kW rating and a concentration ratio of about 800. On-sun tests are performed at a receiver inlet pressure of 150 bar and a receiver inlet temperature between 110-130°C. Receiver and thermal efficiencies in excess of 0.91 and 0.96 respectively for the incident heat flux ranging from 8 to 80 W/cm2, and average surface temperatures ranging from 150-550°C are obtained in these experiments.

14 SOLAR ENERGY↗

Full-scale altitude engine test of a turbofan exhaust-gas-forced mixer to reduce thrust specific fuel consumption

The specific fuel consumption of a low-bypass-ratio, confluent-flow, turbofan engine was measured with and without a mixer installed. Tests were conducted for flight Mach numbers from 0.3 to 1.4 and altitudes from 10,670 to 14,630 meters (35,000 to 48,000 ft) for core-stream-to-fan-stream temperature ratios of 2.0 and 2.5 and mixing-length-to-diameter ratios of 0.95 and 1.74. For these test conditions, the reduction in specific fuel consumption varied from 2.5 percent to 4.0 percent. Pressure loss measurements as well as temperature and pressure surveys at the mixer inlet, the mixer exit, and the nozzle inlet were made.

Cullom, R. R.↗

Thermal characterization of full-scale PCM products and numerical simulations, including hysteresis, to evaluate energy impacts in an envelope application

This article presents combined measurements of fatty acid-based organic PCM products and numerical simulations to evaluate the energy benefits of adding a PCM layer to an exterior wall. The thermal storage characteristics of the PCM were measured using a heat flow meter apparatus (HFMA). The PCM characterization is based on a recent ASTM International standard test method, ASTM C1784. The PCM samples were subjected to step changes in temperature and allowed to stabilize at each temperature. By measuring the heat absorbed or released by the PCM, the temperature-dependent enthalpy functions for melting and freezing were determined.Here, the simulations were done using a previously-validated two-dimensional (2D) wall model containing a PCM layer and incorporating the HFMA-measured enthalpy functions. The wall model was modified to include the hysteresis phenomenon observed in PCMs, which is reflected in different melting and freezing temperatures of the PCM. Simulations were done with a single enthalpy curve based on the PCM melting tests, both melting and freezing enthalpy curves, and with different degrees of hysteresis between the melting and freezing curves. Significant differences were observed between the thermal performances of the modeled wall with the PCM layer under the different scenarios.

2D wall model with PCM↗

Fractal-Like Materials Design with Optimized Radiative Properties for High-Efficiency Solar Energy Conversion

Novel designs to increase light trapping and thermal efficiency of concentrating solar receivers at multiple length scales have been conceived, designed, and tested. The fractal-like geometries and features are introduced at both macro (meters) and meso (millimeters to centimeters) scales. Advantages include increased solar absorptance, reduced thermal emittance, and increased thermal efficiency. Radial and linear structures at the meso (tube shape and geometry) and macro (total receiver geometry and configuration) scales redirect reflected solar radiation toward the interior of the receiver for increased absorptance. Hotter regions within the interior of the receiver can reduce thermal emittance due to reduced local view factors to the environment, and higher concentration ratios can be employed with similar surface irradiances to reduce the effective optical aperture, footprint, and thermal losses. Coupled optical/fluid/thermal models have been developed to evaluate the performance of these designs relative to conventional designs. Modeling results showed that fractal-like structures and geometries can increase the effective solar absorptance by 5 – 20% and the thermal efficiency by several percentage points at both the meso and macro scales, depending on factors such as intrinsic absorptance. Meso-scale prototypes were fabricated using additive manufacturing techniques, and a macro-scale bladed receiver design was fabricated using Inconel 625 tubes. On-sun tests were performed using the solar furnace and solar tower at the National Solar Thermal Test facility. The test results demonstrated enhanced solar absorptance and thermal efficiency of the fractal-like designs.

14 SOLAR ENERGY↗

A possible method for preventing the autorotation of airplane wings

At the suggestion of Professor Betz, the following device was tested with the object of reducing the autorotational speed of airplane wings. The model of a normal wing with the Gottigen profile 420, 1 meter span and 0.2 meter chord was provided with a pair of symmetrical slots on the suction side, connected with each other inside the wing. The arrangement of the testing equipment and models are given and the effect of the slots can be seen in the experimental curves that are included.

Schrenk, Oskar↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Development of a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab for advancing TW technologies necessary more for future accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing) and the lessons learned from the 3-cell, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Here we report a preliminary RF design, development plans, and activities.

43 PARTICLE ACCELERATORS↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Completion Report for Well ER-4-1 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 0

Well ER-4-1 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled and completed from March 23 to April 13, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Yucca Flat/Climax Mine Corrective Action Unit (CAU) 97. The primary purpose of the well was to collect hydrogeologic data to assist in validating concepts of the groundwater flow system within the Yucca Flat/Climax Mine CAU, and to test for potential radionuclides in groundwater from the STRAIT (U4a) underground test. The completed well includes one piezometer (p1), to a depth of 663.16 meters (m) (2,175.71 feet [ft]) below ground surface (bgs) and open from the Alluvial aquifer (AA3) to the Oak Spring Butte confining unit (OSBCU) hydrostratigraphic units; and a main completion (m1), which includes 6.625-inch (in.) casing with slotted interval (m1) installed to 906.80 m (2,975.05 ft) bgs in the Lower carbonate aquifer (LCA). A 13.375-in. diameter surface casing was installed from the surface to a depth of 809.00 m (2,654.21 ft) bgs. Well ER-4-1 experienced a number of technical issues during drilling, including borehole instability and sloughing conditions. An intermediate, 10.75-in./9.625-in. casing string was installed to 856.94 m (2,811.48 ft) bgs to control these issues. Borehole stability and erosion problems appear to be associated with the Tunnel Formation (Tn) and the Older tunnel beds (Ton). Overall efforts to stabilize the borehole were successful. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), a partial suite of geophysical logs to a maximum depth of 766.57 m (2,515 ft) bgs, water-quality measurements (including tritium), water-level measurements, and two depth-discrete bailer samples collected at 538.89 m and 646.18 m (1,768 ft and 2,120 ft) bgs respectively. The well penetrated 187.45 m (615 ft) of Quaternary/Tertiary alluvium (QTa), 671.47 m (2,203 ft) of Tertiary Volcanic rocks (Tv), and 66.20 m (217.19 ft) of Paleozoic rocks (|). The stratigraphy and lithology were generally as expected with some exceptions. The top of Paleozoic rocks (|) was predicted to occur at 822.35 m (2,698 ft) bgs and was intercepted at 858.93 m (2,818 ft), a difference of 36.58 m (120 ft). As expected, the Paleozoic rocks (|) are the principal water producing formation in Well ER-4-1. Depth to water was measured after drilling as follows: In the piezometers: p1 at 320.39 m (1,051.16 ft) bgs, (measured January 4, 2017); and in the main production casing interval: m1 at 539.17 m (1,768.92 ft) bgs, (measured December 12, 2016) Geophysical logs and depth-discrete bailer sample analytical results suggest likely zones of prompt injection (underground-test-related) fission products from 472.44 to 481.48 m (1,550 to 1,580 ft) bgs and at approximately 539.50 m (1,770 ft) bgs. Subsequent work at Well ER-4-1 will be included in future reports. Field measurements for tritium were mostly below the Safe Drinking Water Act limit (20,000 picocuries per liter) with the exception of two zones showing elevated tritium concentrations. The first zone is located at approximately 365.76 to 390.14 m (1,200 to 1,280 ft) bgs and a second zone at approximately 542.54 to 566.93 m (1,780 to 1,860 ft) bgs. All Fluid Management Plan requirements were met.

54 ENVIRONMENTAL SCIENCES↗

Aeolian Removal of Dust Types from Photovoltaic Surfaces on Mars

Dust elevated in local or global dust storms on the Martian surface could settle on photovoltaic (PV) surfaces and seriously hamper their performance. Using a recently developed technique to apply a uniform dust layer, PV surface materials were subjected to simulated Martian winds in an attempt to determine whether natural aeolian processes on Mars would sweep off the settled dust. Three different types of dust were used. The effects of wind velocity, angle of attack, height above the Martian surface, and surface coating material were investigated. It was found that arrays mounted on an angle of attack approaching 45 deg show the most efficient clearing. Although the angular dependence is not sharp, horizontally mounted arrays required much higher wind velocities to clear off the dust. From this test it appears that the arrays may be erected quite near the ground, but previous studies have suggested that saltation effects can be expected to cause such arrays to be covered by soil if they are set up less than about a meter from the ground. Particle size effect appear to dominate over surface chemistry in these experiments, but additional tests are required to confirm this.

Gaier, James R.↗

Leica Absolute Distance Meter

The principle of operation and measured accuracy of the ADM will be presented. Results of the Acceptance Test will be reported.

Hadaway, James↗

Aeolian Removal of Dust Types from Photovoltaic Surfaces on Mars

Dust elevated in local or global dust storms on the Martian surface could settle on photovoltaic (PV) surfaces and seriously hamper their performance. Using a recently developed technique to apply a uniform dust layer, PV surface materials were subjected to simulated Martian winds in an attempt to determine whether natural Aeolian processes on Mars would sweep off the settled dust. Three different types of dust were used; an optical polishing powder, basaltic "trap rock", and iron (III) oxide crystals. The effects of wind velocity, angle of attack, height above the Martian surface, and surface coating material were investigated. It was found that arrays mounted with an angle of attack approaching 45 degrees show the most efficient clearing. Although the angular dependence is not sharp, horizontally mounted arrays required significantly higher wind velocities to clear off the dust. From this test it appears that the arrays may be erected quite near the ground, but previous studies have suggested that saltation effects can be expected to cause such arrays to be covered by soil if they are set up less than about a meter from the ground. Particle size effects appear to dominate over surface chemistry in these experiments, but additional tests are required to confirm this. Providing that the surface chemistry of Martian dusts is not drastically different from simulated dust and that gravity differences have only minor effects, the materials used for protective coatings for photovoltaic arrays may be optimized for other considerations such as transparency, and chemical or abrasion resistance. The static threshold velocity is low enough that there are regions on Mars which experience winds strong enough to clear off a photovoltaic array if it is properly oriented. Turbulence fences proved to be an ineffective strategy to keep dust cleared from the photovoltaic surfaces.

Gaier, James R.↗