Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Flow pattern and void fraction characterization in nitrogen/water flows through a diamond-type triply periodic minimal surface lattice

Here, this study presents, to the authors knowledge, the first experimental investigation on the void fraction and flow patterns in two-phase flows through a diamond-type Triply Periodic Minimal Surface (TPMS) lattice. An additively manufactured TPMS structure was tested under upward co-current flow of a water/nitrogen mixture. Superficial velocities varied for a total of 42 test conditions (gas: 0.01–2.4 m/s; liquid: 0.01–2.4 m/s; mass flux: 20–2370 kg/m 2 ·s). High-speed video and X-ray imaging enabled time-averaged void fraction measurements and identified six distinct flow regimes which were used to develop a flow pattern map. Comparison of the void fraction data with correlations from literature demonstrated the Rouhani and Axelsson (1970) [49] correlation modified by Steiner (1993) [52] provided the best agreement, which was improved with empirically fit coefficients. This approach predicted the void fraction with errors < ±20% for 64% of the data, with a mean absolute percent deviation (MAPD) of 23%. The measured frictional pressure drop was compared to correlations from literature which captured the observed trends but did not provide good accuracy. The best agreement was found after optimizing the empirical coefficients of the Muller-Steinhagen & Heck (1986) [56] correlation; this approach captured 33% of the data within ±20% with a MAPD of 46% over the full range and captured 71% of the data within ±20% a MAPD of 13.3% at mass fluxes >1100 kg/m 2 -s. These results provide foundational insight into TPMS two-phase flow behavior and inform modeling and design of advanced heat exchange components incorporating TPMS geometries.

42 - ENGINEERING↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Distributed quantum sensing enhanced by continuous-variable error correction

Abstract A distributed sensing protocol uses a network of local sensing nodes to estimate a global feature of the network, such as a weighted average of locally detectable parameters. In the noiseless case, continuous-variable (CV) multipartite entanglement shared by the nodes can improve the precision of parameter estimation relative to the precision attainable by a network without shared entanglement; for an entangled protocol, the root mean square estimation error scales like 1/ M with the number M of sensing nodes, the so-called Heisenberg scaling, while for protocols without entanglement, the error scales like 1 / M . However, in the presence of loss and other noise sources, although multipartite entanglement still has some advantages for sensing displacements and phases, the scaling of the precision with M is less favorable. In this paper, we show that using CV error correction codes can enhance the robustness of sensing protocols against imperfections and reinstate Heisenberg scaling up to moderate values of M . Furthermore, while previous distributed sensing protocols could measure only a single quadrature, we construct a protocol in which both quadratures can be sensed simultaneously. Our work demonstrates the value of CV error correction codes in realistic sensing scenarios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved limits on Fierz interference using asymmetry measurements from the Ultracold Neutron Asymmetry (UCNA) experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the β-decay asymmetry parameter, A 0 , for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their β-decay electrons are detected with ≈4π acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to b n , the Fierz interference term in the neutron β-decay rate. In this work, we determine bn from the energy dependence of A 0 using the data taken during the UCNA 2011–2013 run. In addition, we present the same type of analysis using the earlier 2010 A dataset. Furthermore, motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new b n measurement using the weighted average of our asymmetry dataset fits, to obtain b n = 0.066 ± 0.041 stat ± 0.024 syst which corresponds to a limit of -0.012 < b n < 0.144 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurement of 27 P to constrain type-I x-ray burst models and validate the isobaric multiplet mass equation for the $A = 27, T = \frac{3}{2}$ isospin quartet

Background: Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in rp process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the rp process path. Purpose: Perform a precise atomic mass measurement of 27 P. Use this new measurement to calculate rp process reaction rates and input these rates into an x-ray burst model to reduce simulated light curve uncertainty. Use the mass measurement of 27 P to validate the isobaric multiplet mass equation (IMME) for the A = 27 T = 3/2 isospin quartet which 27 P belongs to. Method: High-precision Penning trap mass spectrometry utilizing the time-of-flight ion cyclotron resonance technique was used to determine the atomic mass of 27 P. The MESA code (Modules for Experiments in Stellar Astrophysics) was then used to simulate x-ray bursts using a one-dimensional multizone model to produce updated light curves. Results: The mass excess of 27 P was measured to be –670.7(6) keV, a 14-fold precision increase over the mass reported in the 2020 Atomic Mass Evaluation (AME2020). The 26 Si(p, $γ$) 27 P– 27 P($γ$, p) 26 Si rate equilibrium has been determined to a higher precision based on the precision mass measurement of 27 P. x-ray burst light curves were produced with the MESA code using the new reaction rates. Changes in the mass of 27 P seem to have minimal effect on light curves, even in burster systems tailored to maximize impact. Conclusion: The mass of 27 P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models do not just provide more precise results, but often qualitatively different ones. This result brings us a step closer to being able to extract stellar parameters from individual x-ray burst observations. In addition, the IMME has been validated for the A = 27, T = 3/2 quartet. The normal quadratic form of the IMME using the latest data yields a reduced $χ$ 2 of 2.9. Finally, the cubic term required to generate an exact fit to the latest data matches theoretical attempts to predict this term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Asymmetric errors

We present a procedure for handling asymmetric errors. Many results in particle physics are presented as values with different positive and negative errors, and there is no consistent procedure for handling them. We consider the difference between errors quoted, using pdfs and using likelihoods, and the difference between the rms spread of a measurement and the 68% central confidence region. We provide a comprehensive analysis of the possibilities, and software tools to enable their use.

Asymmetric↗

Sidelobe modeling and mitigation for a three mirror anastigmat cosmic microwave background telescope

Telescopes measuring cosmic microwave background (CMB) polarization on large angular scales require exquisite control of systematic errors to ensure the fidelity of the cosmological results. In particular, far-sidelobe contamination from wide angle scattering is a potentially prominent source of systematic error for large aperture microwave telescopes. Here we describe and demonstrate a ray-tracing-based modeling technique to predict far sidelobes for a three mirror anastigmat telescope designed to observe the CMB from the South Pole. Those sidelobes are produced by light scattered in the receiver optics subsequently interacting with the walls of the surrounding telescope enclosure. After comparing simulated sidelobe maps and angular power spectra for different enclosure wall treatments, we propose a highly scattering surface that would provide more than an order of magnitude reduction in the degree-scale far-sidelobe contrast compared to a typical reflective surface. Finally, we conclude by discussing the fabrication of a prototype scattering wall panel and presenting measurements of its angular scattering profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic uncertainties in the measurement of the neutron lifetime using the Lunar Prospector neutron spectrometer

The lifetime of free neutrons measured in the laboratory has a longstanding disparity of ≈9 s. A space-based technique has recently been proposed to independently measure the neutron lifetime using interactions between the galactic cosmic rays and a low atmosphere planetary body. This technique has not produced competitive results yet due to constraints of nonoptimized data that contain large systematic errors. We use data from the neutron spectrometer on-board NASA's Lunar Prospector, and study two large systematics in the measurement of neutron lifetime: the lunar subsurface temperature and the lunar surface composition. We use the HeCd and HeSn neutron spectrometer data when the spacecraft was in a highly elliptical orbit during the orbit insertion period. We report the neutron lifetime using four different models that each have different choices of surface temperature and composition. The 5° [Prettyman et al ., J. Geophys. Res.: Planets 111, 2005JE002656 (2006)] and 2° [Wilson et al., Phys. Rev. C 104, 045501 (2021)] rebinned maps result in 777.6±11.7 s and 739.6±10.8 s, respectively. For the 20° map (Prettyman et al., 2006), constant equatorial and a latitude-dependent temperature model result in 738.6±10.8 s and 767.3±11.2 s, respectively. Increasing the complexities of the models accounting for the systematic effects increase the measured lifetime. However, the reported measurements are not competitive with the laboratory results due to large unaccounted systematics resulting from nonoptimized measurements and modeling assumptions. This work serves as a study of systematic uncertainties for future neutron lifetime measurements using the space-based technique. We estimate the effect on the lifetime from the choice of temperature model to be to be 28.7 ±15.5 s, and choice of compositional map (for 20° and 5° maps) to be 10.3 ±12.2 s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-map framework for noise characterization of quantum computers

In order to understand the capabilities and limitations of quantum computers, it is necessary to develop methods that efficiently characterize and benchmark error channels present on these devices. In this paper, we present a method that faithfully reconstructs a marginal (local) approximation of the effective noise (MATEN) channel, that acts as a single layer at the end of the circuit. We first introduce a dual-map framework that allows us to analytically derive expectation values of observables with respect to noisy circuits. These findings are supported by numerical simulations of the quantum approximate optimization algorithm (QAOA) that also justify the MATEN, even in the presence of nonlocal errors that occur during a circuit. Finally, we demonstrate the performance of the method on Rigetti's Aspen-11 quantum computer for QAOA circuits up to six qubits, successfully predicting the observed measurements on a majority of the qubits.

Sud, James↗

Measuring the Loschmidt Amplitude for Finite-Energy Properties of the Fermi-Hubbard Model on an Ion-Trap Quantum Computer

Calculating the equilibrium properties of condensed-matter systems is one of the promising applications of near-term quantum computing. Recently, hybrid quantum-classical time-series algorithms have been proposed to efficiently extract these properties from a measurement of the Loschmidt amplitude ⟨ ψ | e − i H ^ t | ψ ⟩ from initial states | ψ ⟩ and a time evolution under the Hamiltonian H ^ up to short times t . In this work, we study the operation of this algorithm on a present-day quantum computer. Specifically, we measure the Loschmidt amplitude for the Fermi-Hubbard model on a 16 -site ladder geometry (32 orbitals) on the Quantinuum H2-1 trapped-ion device. We assess the effect of noise on the Loschmidt amplitude and implement algorithm-specific error-mitigation techniques. By using a thus-motivated error model, we numerically analyze the influence of noise on the full operation of the quantum-classical algorithm by measuring expectation values of local observables at finite energies. Finally, we estimate the resources needed for scaling up the algorithm. Published by the American Physical Society 2024

Physics↗

Additive manufacturing enabled hot-wire apparatus with suppressed edge effect error

This invention describes a method of structuring a metal or metal coated wire in a manner such that it provides enhanced accuracy when used in a hot-wire apparatus for transient thermal conductivity measurements for low-density materials. This is accomplished by using a diameter varying structure with two ends of the wire of sufficiently small diameter that the edge-effect induced error can be reduced by generating a more uniform temperature profile along the wire, whereas in conventional apparatus the temperatures always drop at the ends of a finite wire due to its ends that are being cooled by the wire-supports.

36 MATERIALS SCIENCE↗

Baryon acoustic oscillation theory and modelling systematics for the DESI 2024 results

This paper provides a comprehensive overview of how fitting of baryon acoustic oscillations (BAO) is carried out within the upcoming Dark Energy Spectroscopic Instrument’s (DESI) 2024 results using its DR1 data set, and the associated systematic error budget from theory and modelling of the BAO. We derive new results showing how non-linearities in the clustering of galaxies can cause potential biases in measurements of the isotropic (⁠α iso ⁠) and anisotropic (⁠α ap ) BAO distance scales, and how these can be effectively removed with an appropriate choice of reconstruction algorithm. We then demonstrate how theory leads to a clear choice for how to model the BAO and develop, implement, and validate a new model for the remaining smooth-broad-band (i.e. without BAO) component of the galaxy clustering. Finally, we explore the impact of all remaining modelling choices on the BAO constraints from DESI using a suite of high-precision simulations, arriving at a set of best practices for DESI BAO fits, and an associated theory and modelling systematic error. Overall, our results demonstrate the remarkable robustness of the BAO to all our modelling choices and motivate a combined theory and modelling systematic error contribution to the post-reconstruction DESI BAO measurements of no more than 0.1 per cent (0.2 per cent) for its isotropic (anisotropic) distance measurements. We expect the theory and best practices laid out to here to be applicable to other BAO experiments in the era of DESI and beyond.

79 ASTRONOMY AND ASTROPHYSICS↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Forward sensitivity approach for estimating eddy viscosity closures in nonlinear model reduction

In this paper, we propose a variational approach to estimate eddy viscosity using forward sensitivity method (FSM) for closure modeling in nonlinear reduced order models. FSM is a data assimilation technique that blends model's predictions with noisy observations to correct initial state and/or model parameters. We apply this approach on a projection based reduced order model (ROM) of the one-dimensional viscous Burgers equation with a square wave defining a moving shock, and the two-dimensional vorticity transport equation formulating a decay of Kraichnan turbulence. We investigate the capability of the approach to approximate an optimal value for eddy viscosity with different measurement configurations. Specifically, we show that our approach can sufficiently assimilate information either through full field or sparse noisy measurements to estimate eddy viscosity closure to cure standard Galerkin reduced order model (GROM) predictions. Therefore, our approach provides a modular framework to correct forecasting error from a sparse observational network on a latent space. We highlight that the proposed GROM-FSM framework is promising for emerging digital twin applications, where real-time sensor measurements can be used to update and optimize surrogate model's parameters.

42 ENGINEERING↗

Reduction of baseplate distortion during directed energy deposition using compliant features

Distortion in additive manufacturing (AM) remains a barrier to its adoption in precision industries. Baseplate warpage is one such issue which compromises the feasibility of post-process precision machining. The restriction to thermal contraction of the deposited part, imposed by the baseplate, generates bending moments, that in turn causes warpage. A novel distortion mitigation strategy using baseplates with integrated compliant features, which enables thermal contraction of the build is presented. Six unique design concepts are evaluated, including a solid reference, using two deposition geometries. A laser, hot-wire, directed energy deposition (DED) process is used to deposit a symmetric cylindrical part (C-part) and a T-shaped asymmetric part (T-part). Flatness deviation of baseplates is measured using structured light 3D scanning. Measurements reveal a reduction in net flatness deviation of 58.8% for the C-part and 40.9% for the T-part, compared to the solid reference. While most designs yielded reductions exceeding 30% and 20% for the C- and T-parts, respectively, one configuration resulted in increased deviation. Finite element (FE) simulations are performed to elucidate the underlying mechanisms affecting distortion of compliant baseplates during DED. Despite variations between predictions and measurements, agreement in the general trend is observed. It also revealed that initial flatness errors in baseplates significantly affect its deviation during deposition. Predictions indicate that compliant features significantly affect the thermal distribution as well as the evolution of flatness deviation in the baseplate during deposition. Notably, one design exhibited a reduction in distortion during cooling, following its initial increase during deposition. FE predictions show a maximum reduction of 60.9% and 38.8% in net flatness deviation for the C- and T-parts, respectively. The performance of compliant baseplates is found to be governed by both its the thermal and mechanical characteristics, which are crucial factors to be considered during design.

Mathews, Ritin [ORNL] (ORCID:0000000301440828)↗

Two-layer transient heat transfer using impulse response methods

Solutions to the inverse heat conduction problem (IHCP) are methods that can be used to quantify surface heat flux in multi-layer materials for components in which there are limited subsurface (internal) temperature measurements, such as coated components. A critical consideration is to capture high frequency fluctuations using a practical heat flux sensor. To that end, this paper highlights key parameters for calculating accurate surface heat transfer. Specifically, this research extends the available solutions to the IHCP for multi-substrate structures through an impulse response methodology. The sensitivity of the impulse method was quantified with respect to practical measurements. Further, when compared to the inverse case, the impulse method resulted in lower errors when calculating surface heat flux over a range of conditions. Overall, this work provides a foundation for deducing heat flux from a subsurface heat flux sensor while maintaining a high-frequency response.

42 ENGINEERING↗

Constructing a spatiotemporally coherent long-term PM2.5 concentration dataset over China during 1980–2019 using a machine learning approach

The lack of long-term observations and satellite retrievals of health-damaging fine particulate matter in China has demanded the estimates of historical PM 2.5 (particulate matter less than 2.5 µm in diameter) concentrations. This study constructs a gridded near-surface PM 2.5 concentration dataset across China covering 1980–2019 using the space-time random forest model with atmospheric visibility observations and other auxiliary data. The modeled daily PM2.5 concentrations are in excellent agreement with ground measurements during 2015–2019, with a coefficient of determination of 0.95 and mean relative error of 12%. Besides the atmospheric visibility which explains 30% of total importance of variables in the model, both emissions and meteorological conditions are also essential factors affecting PM2.5 predictions. From 1980 to 2014, the model-predicted PM2.5 concentrations increased constantly with the maximum growth rate of 5–10 µg/m3/decade over eastern China. Due to the clean air actions, PM 2.5 concentrations have decreased effectively at a rate over 50 µg/m 3 /decade in the North China Plain and 20–50 µg/m 3 /decade over eastern China during 2014–2019. The newly generated dataset of 1-degree gridded PM 2.5 concentrations for the past 40 years across China provides a useful means for investigating interannual and decadal environmental and climate impacts related to aerosols.

54 ENVIRONMENTAL SCIENCES↗