Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Initial Mobility Analysis for ORNL VA-EDH Synthetic Populations

Travel burdens are a major barrier to healthcare access among US Veteran patient populations, particularly those residing in rural areas. Spatial accessibility to points of care for US Veteran populations is commonly assessed in two ways. The first approach uses open data from the US Census to represent collective travel burdens, for example the distance between population-weighted census tract centroids and VHA points of care. The second approach uses restricted-access VHA patient data to measure travel costs (e.g., distance, time) for accessing points of care with respect to geolocated patient addresses and real or approximated transportation networks. While the advantage of the open data approach lies in its reproducibility, it has notable limitations in its tendency to infer individual travel behavior from aggregate population characteristics, a problem known as ecological fallacy. Conversely, while the patient data approach is able to account for individual travel behavior, its ability to account for localized access disparities (e.g., a neighborhood with exceptionally high transportation costs) and patient demographics is limited as protecting individual patient data requires their storage in closed systems with limited capacity for adequately modeling real-world travel patterns or for supplementing patient attributes. Additionally, the patient data approach cannot account for veterans who are not enrolled in the VHA system but who may be eligible for care. These challenges limit the ability to perform “what if” analyses on the effects of place-specific interventions on veteran populations with high access barriers to healthcare. To address these challenges, we explore the application of realistic synthetic populations to examine travel burdens and spatial accessibility issues among veteran patient populations. Synthetic populations provide a virtual, individually-resolved and cross-sectional representation of the veteran patient population that enables investigation of spatial access to points of care in ways in which aggregate data and patient data do not. First, synthetic populations allow one to directly assess how individuals access points of care, from synthesized residential locations to outpatient facilities on real-world transportation networks. Modeling access to points of care at the individual scale addresses the ecological fallacy problem associated with using aggregated census data to represent veteran populations and patterns of movement. Second, synthetic populations provide a means of completely representing an area’s veteran population using only publicly available, anonymized census microdata from the American Community Survey (ACS) to ensure the privacy of real-world individuals. Generating synthetic populations from the ACS also expands descriptive characteristics beyond what patient data typically offers to include socio-demographic, economic, housing, and mobility attributes. More detailed profiles of both VHA patient populations and veterans not enrolled in the VA system will provide a comprehensive picture of groups that may benefit from interventions or outreach. As an initial exercise for using synthetic populations to measure veteran travel burdens to VA care, we apply Oak Ridge National Laboratory’s (ORNL) UrbanPop capability to generate a series of synthetic VHA patient populations for 9 Veterans Integrated Services Networks (VISN) market areas in 9 Census Divisions across the continental United States, which are listed in Table 1. We use UrbanPop to produce synthetic populations for the VISN markets selected for each US Census Division, then assign VA outpatient clinic destinations to synthetic VHA patients based on travel about each VISN market’s road network. To demonstrate using the synthetic populations to evaluate healthcare travel burdens, we compare the time-based impedance between simulated home locations and VA outpatient clinics in each VISN market. We then perform validation exercises on the synthetic populations with respect to neighborhood (block group) demographic composition as well as patient mobility, comparing aggregate origin-destination statistics for the synthetic population to outpatient visits available in restricted patient data from the VA’s Corporate Data Warehouse (CDW) database.

97 MATHEMATICS AND COMPUTING↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetism and spin dynamics in room-temperature van der Waals magnet Fe 5 GeTe 2

Two-dimensional van der Waals (vdWs) materials have gathered a lot of attention recently. However, the majority of these materials have Curie temperatures that are well below room temperature, making it challenging to incorporate them into device applications. In this work, we synthesized a room-temperature vdW magnetic crystal Fe 5 GeTe 2 with a Curie temperature T c = 332 K, and studied its magnetic properties by vibrating sample magnetometry (VSM) and broadband ferromagnetic resonance (FMR) spectroscopy. The experiments were performed with external magnetic fields applied along the c -axis (H∥ c ) and the ab -plane (H∥ ab ), with temperatures ranging from 300 to 10 K. We have found a sizable Landé g -factor difference between the H∥ c and H∥ ab cases. In both cases, the Landé g -factor values deviated from g = 2. This indicates contribution of orbital angular momentum to the magnetic moment. The FMR measurements reveal that Fe 5 GeTe 2 has a damping constant comparable to Permalloy. With reducing temperature, the linewidth was broadened. Together with the VSM data, our measurements indicate that Fe 5 GeTe 2 transitions from ferromagnetic to ferrimagnetic at lower temperatures. Our experiments highlight key information regarding the magnetic state and spin scattering processes in Fe 5 GeTe 2 , which promote the understanding of magnetism in Fe 5 GeTe 2 , leading to implementations of Fe 5 GeTe 2 based room-temperature spintronic devices.

36 MATERIALS SCIENCE↗

Analysis and Validation of Spectral Irradiance Simulations for 75 kW Bifacial Solar Test Field

This work investigates how the spectrum of irradiance incident on the rear of bifacial modules impacts their performance. Light incident on the rear of bifacial modules can be reflected from the ground, mounting structures, and other nearby objects, causing both the intensity and spectrum to be modified. As a result, PV cells and sensors with different spectral responses report different values for the rear irradiance, leading to increased uncertainty when modeling performance. Here, we calculate the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single-axis-tracked bifacial test site. Spectral responses for different sensors and PV cells are applied and compared with field measurements for four days. Based on these results, a method for improving non-spectral simulations is proposed. In addition, a linear regression is applied to the modeled spectral results as a method to gain insight into the contributions of ground reflected light to total rear irradiance.

bifacial photovoltaics↗

Big Data Processing for Power Grid Event Detection

In this paper we present the application of big data processing for the development of machine learning (ML) models to detect relevant events in power grid operations. This is based on almost 20TB of phasor measurement unit data corresponding to up to two years of operation of three grid interconnections which provide power to most of the United States. A significant aspect of the work consists in having all data processing performed on a single standard GPU server, from pre-processing to ML model training and testing. We describe the data and computational infrastructure, challenges faced and methods used in data processing, main findings and results. The ML approach employed for best utilization of the big data is also discussed, including sample results.

Paes Leao, Bruno↗

Status of the RRR evaluations for 233,235 U and 239 Pu [Slides]

The presentation discusses the R -Matrix Analysis of 233 U, 235 U, and 239 Pu and how their interplay among PFNS, TNC, RRR, and neutron multiplicities has a significant impact on benchmarks. The presentation also discusses the 233 U improved agreement on benchmarks, an additional investigation on the thickness of beryllium reflectors, work on URR (up to 40 keV) and/or extension of RRR (600 eV to 2 keV). Also discussed is how the 235 U progresses on understanding reactivity rates related to depletion calculations, improved agreement with measured (capture) data is quite insensitive to resolve the negative slope, and how the 239 Pu negative slope as a function of the temperature is not understood yet (bias over 2σ lower than measured).

07 ISOTOPE AND RADIATION SOURCES↗

CHELAX-BNF: Turbulent Parameters by airborne measurements

The original data were collected on board the ARM Aerial Facility ArcticShark uncrewed aerial system (UAS; https://www.arm.gov/capabilities/observatories/aaf/uas ) during the “Characterizing HEterogeneous Land-Atmosphere eXchanges at BNF” field campaign (CHEAX-BNF; https://arm.gov/research/campaigns/aaf2025CHELAX-BNF ). The ARM Aerial Facility ArcticShark UAS was based at the public-use airport of Posey Field, AL (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from May 28 through June 23, 2025. The ArcticShark UAS performed 5 flights, including 4 research flights over the BNF Main Site (ARM Mobile Facility 3, https://arm.gov/capabilities/observatories/amf ) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration, and aerosol size distribution. The current data set presents a collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe.

Aircraft Integrated Meteorological Measurement Sys↗

Status of the RRR evaluations for 233,235 U and 239 Pu [Slides]

The presentation discusses the R -Matrix Analysis of 233 U, 235 U, and 239 Pu and how their interplay among PFNS, TNC, RRR, and neutron multiplicities has a significant impact on the benchmarks. The presentation also discusses the 233 U improved agreement on benchmarks, an additional investigation on the thickness of beryllium reflectors, work on URR (up to 40 keV) and/or extension of RRR (600 eV to 2 keV). Also discussed is how the 235 U progresses on understanding reactivity rates related to depletion calculations, improved agreement with measured (capture) data is quite insensitive to resolve the negative slope, and how the 239 Pu negative slope as a function of the temperature is not understood yet (bias over 2σ lower than measured).

07 ISOTOPE AND RADIATION SOURCES↗

Utah FORGE: Pump and Probe Test on an Intact Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally increased from 1 MPa to 17 MPa before being reduced back to 1 MPa. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Consensus International Solar Resource Standards and Best Practices Development

Standardization and best practices of data sets and models enable the industry to develop widely accepted protocols adapted to various stages of solar project development and operations. In collaboration with the International Energy Agency Photovoltaic Power Systems Programme Task 16, the National Renewable Energy Laboratory (NREL) developed and regularly updates the Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications. In collaboration with ASTM's radiometry subcommittee, NREL leads the development of various radiometric standards. These contribute to increased accuracy in the measurement of the solar resource available to conversion systems and boost the development and improvement of radiative models. These models can then provide the long-term geographic or climatic distribution of solar radiation for areas where measured solar data are not available. Further, these standards play a preeminent role in all aspects of solar energy projects, including standard conditions, methods and instrumentation, accelerated testing, and service lifetime of materials.

ASTM↗

Synthesizing realistic sand assemblies with denoising diffusion in latent space

Abstract The shapes and morphological features of grains in sand assemblies have far‐reaching implications in many engineering applications, such as geotechnical engineering, computer animations, petroleum engineering, and concentrated solar power. Yet, our understanding of the influence of grain geometries on macroscopic response is often only qualitative, due to the limited availability of high‐quality 3D grain geometry data. In this paper, we introduce a denoising diffusion algorithm that uses a set of point clouds collected from the surface of individual sand grains to generate grains in the latent space. By employing a point cloud autoencoder, the three‐dimensional point cloud structures of sand grains are first encoded into a lower‐dimensional latent space. A generative denoising diffusion probabilistic model is trained to produce synthetic sand that maximizes the log‐likelihood of the generated samples belonging to the original data distribution measured by a Kullback‐Leibler divergence. Numerical experiments suggest that the proposed method is capable of generating realistic grains with morphology, shapes and sizes consistent with the training data inferred from an F50 sand database. We then use a rigid contact dynamic simulator to pour the synthetic sand in a confined volume to form granular assemblies in a static equilibrium state with targeted distribution properties. To ensure third‐party validation, 50,000 synthetic sand grains and the 1542 real synchrotron microcomputed tomography (SMT) scans of the F50 sand, as well as the granular assemblies composed of synthetic sand grains are made available in an open‐source repository.

Vlassis, Nikolaos N.↗

High-Impedance Non-Linear Fault Detection via Eigenvalue Analysis with low PMU Sampling Rates

This work presents a hybrid data-driven and physics-based framework for high-impedance fault detection in power systems. An innovative method based on eigenvalue analysis is expanded and validated. Phasor Measurement Unit data is used to estimate eigenvalues corresponding to the powerlines being monitored. The projection and drift of these eigenvalues is then tracked and evaluated. Faults are detected as they drive eigenvalues outside of their normal zones. Eigenvectors are leveraged to support and validate the decisions made by the main algorithm. This technique holds several advantages over contemporary techniques in that it utilizes technology that is already deployed in the field, it offers a significant degree of generality, and so far it has displayed a very high-level of sensitivity without sacrificing accuracy. Validation takes place in the form of simulations in the IEEE 13 Node System considering a popular high-impedance non-linear fault model. Test results are encouraging indicating potential for real-life applications.

Paramo, Gian↗

Radiometric Standards and Best Practices: Recent Progress

International standards and best practices for solar resource assessments provide assurance for traceable measurements associated with a low uncertainty. This benefits the solar energy industry by reducing the investment risks through heightened confidence in the solar resource information. NREL, in collaboration with international organizations, such as subcommittees G03 of ASTM (Radiometry) and TC180/SC1 of ISO (Climate measurement and data), recently revised some standards that are widely used by the solar industry. These include radiometric standards that assist in (i) maintaining calibration traceability; (ii) uncertainty analysis; (iii) measurement quality assurance, and (iv) establishing reference spectral irradiance distributions. The latter are widely used by the solar community to evaluate the actual absorptance, reflectance, and transmittance of solar energy materials, or the performance of solar energy devices and systems, relative to standard conditions. This paper provides a summary of the recent changes brought to these standards as a way to better support the solar energy industry.

industries↗

CHELAX-BNF: Fast Response Temperature by airborne measurements

The original data were collected on board the ARM Aerial Facility ArcticShark uncrewed aerial system (UAS; https://www.arm.gov/capabilities/observatories/aaf/uas ) during the “Characterizing HEterogeneous Land-Atmosphere eXchanges at BNF” field campaign (CHEAX-BNF; https://arm.gov/research/campaigns/aaf2025CHELAX-BNF ). The ARM Aerial Facility ArcticShark UAS was based at the public-use airport of Posey Field, AL (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from May 28 to June 23, 2025. The ArcticShark UAS performed 5 flights, including 4 research flights over the BNF Main Site (ARM Mobile Facility 3, https://arm.gov/capabilities/observatories/amf ) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration, and aerosol size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in the form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization↗