Compositional Analysis of Water-Soluble Materials in Switchgrass
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In this memo, the dose to an O-ring from the alpha decay of 238 PuO 2 is calculated. These calculations were made in order to assess possible radiation damage to the O-ring, which could lead to failure and loss of integrity of the seal created by the O-ring. The O-ring being discussed here provides the seal between the lid and bottom of a nuclear materials container. The container will be used for the storage and transport of a number of different radioactive materials. The analysis is made using 238 PuO 2 as it would create the greatest damage to the O-ring when considering the materials that may be stored in it. Contamination of the O-ring is not expected to occur. But in the event radioactive material comes in contact with the O-ring, these calculations provide an estimate of the radiation damage.
A new photoluminescence material, tris (2-methyl-8-hydroxy quinoline) lanthanum has been synthesized and characterized by different techniques. The prepared material La(mq){sub 3} was characterized for structural, thermal and photoluminescence analysis. Structural analysis of this material was done by fourier transformed infrared spectroscopy (FTIR) and mass spectroscopy. Thermal analysis of this material was done by thermal gravimetric analysis (TGA) shows the thermal stability up to 400°C. Absorption and emission spectra of the material was measured by UV-visible spectroscopy and photoluminescence spectroscopy. Solution of this material La(mq){sub 3} in ethanol showed absorption peak at 385 nm respectively which may be attributed due to (π – π*) transitions. The photoluminescence spectra of La(mq){sub 3} in ethanol solution showed intense peak at 430 nm.
Atomic absorption and emission spectroscopy, and neutron activation for ultratrace chemical analysis of materials for semiconductor
The rising demand for food and energy crops has triggered interest in the use of nanoparticles for agronomy. Specifically, iron oxide-based engineered nanoparticles are promising candidates for next-generation iron-deficiency fertilizers. We used iron oxide and hybrid Pt-decorated iron oxide nanoparticles, at low and high concentrations, and at varied pHs, to model seed pre-soaking solutions for investigation of their effect on embryonic root growth in legumes. This is an environmentally friendly approach, as it uses less fertilizer, therefore less nanoparticles in contact with the soil. Analysis from varied material characterization techniques combined with a statistical analysis method found that iron oxide nanoparticles could enhance root growth by 88–366% at low concentrations (5.54 × 10 -3 mg L -1 Fe). Hybrid Pt-decorated iron oxide nanoparticles and a higher concentration of iron oxide nanoparticles (27.7 mg L -1 Fe) showed reduced root growth. The combined materials characterization and statistical analysis used here can be applied to address many environmental factors to finely tune the development of vital nanofertilizers for high efficiency food production.
Redistribution of zinc over the electrode surface, also known as shape change, is a major problem and a cause of failure in alkaline zinc anode batteries. To mitigate this phenomenon, we propose a scalable approach based on an in situ formed, highly porous electrochemically synthesized ZnO matrix with uniformly electrodeposited zinc particles. This results in ∼70% improvement in cycle life performance at a rate of 10 mA cm −2 compared to control Zn anodes, which have not gone through the formation process. A quantitative electrolyte analysis revealed under-saturated zincate ion concentration in the electrochemically synthesized ZnO/Zn cells indicating reduced zincate movement. Post mortem analysis of the anodes indicated higher retention of both Zn and ZnO on the electrochemically synthesized ZnO anodes signifying reduced redistribution of active material. Image analysis of the cycled anodes revealed a narrower Zn particle size distribution (62−79 μ m) in contrast to a wider particle size distribution of 51–96 μ m observed in the control anodes. The formation approach results in electrochemically synthesized ZnO/Zn anodes providing a stable ZnO matrix in which Zn particles retain their localized distribution on cycling better than control electrodes conventionally made by pasting zinc particles together with a binder.
The Sample Analysis at Mars (SAM) Instrument Suite on the Mars Science Laboratory (MSL) Rover Curiosity made its first solid sample evolved gas analysis of unconsolidated material at aeolian bedform Rocknest in Gale Crater. The magnitude of O2 evolved in each run as well as the chlorinated hydrocarbons detected by SAM gas chromatograph/ mass spectrometer (GCMS) [1] suggest a chlorinated oxidant such as perchlorate in Rocknest materials [2]. Perchlorate induced combustion of organics present in the sample would contribute to the CO2 volatile inventory, possibly overlapping with CO2 from inorganic sources. The resulting carbon and oxygen isotopic composition of CO2 sent to the Tunable Laser Spectrometer (TLS) for analysis would represent mixed sources. This work was undertaken to better understand a) how well the carbon isotopic composition ( 13C) of CO2 from partially combusted products represents their source and b) how the 13C of combusted products can be deconvolved from other carbon sources such as thermal decomposition of carbonate.
Heat flow in a disc due to moving heat generated by electron beam was studied analytically. Computer programs based on the finite-element method were developed for the analysis of two and three dimensional mathematical models. The limited experimental data were compared with the analytical results, and factors which had influence on heat flow in the disc were studied. The computer programs were modified to consider the effects of metal melting and solidification as well as radiation. Temperature dependency of thermophysical properties was also considered.
Purpose: To determine our institutional vertebral compression fracture (VCF) rate after spine stereotactic radiosurgery (SRS) and determine contributory factors. Methods and Materials: Retrospective analysis from 2001 to 2013 at a single institution was performed. With institutional review board approval, electronic medical records of 1905 vertebral bodies from 791 patients who were treated with SRS for the management of primary or metastatic spinal lesions were reviewed. A total of 448 patients (1070 vertebral bodies) with adequate follow-up imaging studies available were analyzed. Doses ranging from 10 Gy in 1 fraction to 60 Gy in 5 fractions were delivered. Computed tomography and magnetic resonance imaging were used to evaluate the primary endpoints of this study: development of a new VCF, progression of an existing VCF, and requirement of stabilization surgery after SRS. Results: A total of 127 VCFs (11.9%; 95% confidence interval [CI] 9.5%-14.2%) in 97 patients were potentially SRS induced: 46 (36%) were de novo, 44 (35%) VCFs progressed, and 37 (29%) required stabilization surgery after SRS. Our rate for radiologic VCF development/progression (excluding patients who underwent surgery) was 8.4%. Upon further exclusion of patients with hematologic malignancies the VCF rate was 7.6%. In the univariate analyses, females (hazard ratio [HR] 1.54, 95% CI 1.01-2.33, P=.04), prior VCF (HR 1.99, 95% CI 1.30-3.06, P=.001), primary hematologic malignancies (HR 2.68, 95% CI 1.68-4.28, P<.001), thoracic spine lesions (HR 1.46, 95% CI 1.02-2.10, P=.02), and lytic lesions had a significantly increased risk for VCF after SRS. On multivariate analyses, prior VCF and lesion type remained contributory. Conclusions: Single-fraction SRS doses of 16 to 18 Gy to the spine seem to be associated with a low rate of VCFs. To the best of our knowledge, this is the largest reported experience analyzing SRS-induced VCFs, with one of the lowest event rates reported.
The emerging advanced porous materials, e.g. extended framework materials and porous molecular materials, offer an unprecedented level of control of their structure and function. The enormous possibilities for tuning these materials by changing their building blocks mean that, in principle, optimally performing materials for a variety of applications can be systematically designed. However, the process of finding a set of optimal structures for a given application requires computational high-throughput tools to analyze and sieve through many candidate materials. In particular, in the case of porous molecular materials, the analysis and selection of a molecule is one of the key aspects as the structure of the molecule determines the structure of the resulting material, and very often the porosity of the molecule significantly contributes to the porous properties of the resulting material. In this work, we introduce definitions and algorithms to characterize porosity at the molecular level, along with a software implementation of these algorithms. We demonstrate applications of the software tool in the discovery and characterization of porous molecules among ca. 94 million molecules currently enlisted in the PubChem database.
Topics covered include: Introduction and motivation; Research objectives and approach; Nuclear materials; Core analysis techniques; Current work; and preliminary results.
Not Available
A new photoluminescence material, (8-hydroxy quinoline) bis (2-2’bipyridine) lanthanum has been synthesized and characterized by different techniques. The prepared material La(Bpy){sub 2}q was characterized for structural, thermal and photoluminescence analysis. Structural analysis of this material was done by Fourier transformed infrared spectroscopy (FTIR) and mass spectroscopy. Thermal analysis of this material was done by thermal gravimetric analysis (TGA) shows the thermal stability up to 190°C.Absorption and emission spectra of the material was measured by UV-visible spectroscopy and photoluminescence spectroscopy. Solution of this material La(Bpy){sub 2}q in ethanol showed absorption peak at 385nm, which may be attributed due to (π – π*) transitions. The photoluminescence spectra of La(Bpy){sub 2}q in ethanol solution showed intense peak at 490 nm.
The ability to spatially resolve the chemical distribution of compounds on a surface is important in many applications ranging from biological to material science. To this extent, we have recently introduced a hybrid atomic force microscopy (AFM)-mass spectrometry (MS) system for direct thermal desorption and pyrolysis of material with nanoscale chemical resolution. However, spatially resolved direct surface heating using local thermal desorption becomes challenging on material surfaces with low melting points, because the material will undergo a melting phase transition due to heat dissipation prior to onset of thermal desorption. Therefore, here we developed an approach using mechanical sampling and collection of surface materials on an AFM cantilever probe tip for real-time analysis directly from the AFM tip. This approach allows for material to be concentrated directly onto the probe for subsequent MS analysis. We evaluate the performance metrics of the technique and demonstrate localized MS sampling from a candelilla wax matrix containing UV stabilizers avobenzone and oxinoxate from areas down to 250 nm × 250 nm. Overall, this approach removes heat dissipation into the bulk material allowing for a faster desorption and concentration of the gas phase analyte from a single heating pulse enabling higher signal levels from a given amount of material in a single sampling spot.
A frontier challenge in implementing femtosecond electron microscopy is to gain precise optical control of intense beams to mitigate collective space charge effects for significantly improving the throughput. Here, we explore the flexible uses of an RF cavity as a longitudinal lens in a high-intensity beam column for condensing the electron beams both temporally and spectrally, relevant to the design of ultrafast electron microscopy. Through the introduction of a novel atomic grating approach for characterization of electron bunch phase space and control optics, we elucidate the principles for predicting and controlling the phase space dynamics to reach optimal compressions at various electron densities and generating conditions. We provide strategies to identify high-brightness modes, achieving ∼100 fs and ∼1 eV resolutions with 106 electrons per bunch, and establish the scaling of performance for different bunch charges. These results benchmark the sensitivity and resolution from the fundamental beam brightness perspective and also validate the adaptive optics concept to enable delicate control of the density-dependent phase space structures to optimize the performance, including delivering ultrashort, monochromatic, high-dose, or coherent electron bunches.
Composite or polymeric insulators are being used in various parts of the world for high-voltage transmission and distribution lines. In some parts of India, places in the states like Rajasthan and Gujarat experience an increase in the daytime temperature up to 50 °C, while the nighttime temperature reduces as low as 3-5 °C. Because of these extreme temperature variations along with electric stress and humidity conditions, composite insulators have to perform well over their lifetime to ensure the reliability of the transmission network. In the present work, experimental conditions are simulated with temperature variation from 50 to 3-5 °C along with electrical stress, humidity variation, pollution, and ultraviolet radiations. Accelerated aging studies with these stresses are conducted to understand the degradation on the insulator similar to the field conditions. Surface resistivity measurements, leakage current analysis, and surface degradation studies using thermogravimetric analysis, scanning electron microscopy, energy-dispersive x-ray, and Fourier transform infrared spectroscopy (FTIR) are conducted. Some interesting results obtained from the study are presented. Experimentation under extreme conditions with polluted insulators showed considerable degradation which was inferred from the material testing analysis. The insulator slabs on which electrical stress was not applied showed a considerable peak at 1500 cm{sup −1} in the FTIR spectra, indicating the generation of low molecular weight PDMS chains from the bulk due to UV aging and thermal stress, while the degradation pattern of non-polluted sample was severe compared to the slab treated but was considerably less severe in comparison with the polluted insulator sample exhibiting pollution can considerably increase degradation rate.
Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.
In support of Savannah River Remediation’s (SRR) deployment of an ion exchange process to remove radioactive cesium from waste supernate, referred to as the Tank Closure Cesium Removal (TCCR) process, SRNL was tasked with validating the field protocol for pretreating the crystalline silicotitanate (CST) material to be used in the columns, preparing CST for use in in-tank batch contact testing, as well as developing a digestion standard to verify complete dissolution of the CST prior to characterization after each in-tank batch contact test. A procedure (SRNL L29 Manual, ITS-0229) was developed to document the protocol for pretreating CST utilizing conditions similar to what will be performed in the field. Analysis of material pretreated following the procedure confirmed similar conversion to the Na+ form of the resin as had been obtained previously. Portions of the batch of material pretreated according to the developed protocol were also used for development of a digestion standard. Results from digestion and analysis of this standard were used to establish a set of control limits for the measured Ti, Zr, and Nb concentrations in digested CST material. An aliquot of this standard CST material will be digested and analyzed alongside each in-tank batch contact sample, and the measured concentrations of Ti, Zr, and Nb will be compared against the established control limits to confirm complete digestion has occurred.