Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

An Update on Microreactor Automated Control System (MACS)

Automation of control systems is expected to be important in the economic and safe operation of microreactors. There is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a microreactor automated control system (MACS) testbed developed to test control system automation. While a future goal is to demonstrate this system using a prototypic microreactor such as MARVEL, the present focus is on developing and testing within a non-nuclear testbed. The testbed, developed in collaboration with Idaho National Laboratory, includes hardware-in-the-loop simulation and uses a Modelica-based model of a prototypic microreactor for use in testing control automation. Research to date at Oak Ridge National Laboratory has focused on the development of prototypic software for automating plant-level control under selected scenarios. Empirical testing on the integrated MACS testbed was performed to quantify key characteristics of the integrated testbed and to demonstrate the use of the software for automating the calculation and use of actuation setpoints for selected load-following scenarios. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

FY25 Status Update on A709 Code Case Testing at ANL

This report provides an update on the status of the creep rupture testing on the precipitation-treated (PT) Alloy 709 samples fabricated from the first, the second and the third commercial heats, in support of the first, 100,000-hour Alloy 709 Code Case development under the American Society of Mechanical Engineers (ASME) Section III, Division 5 for high-temperature reactor construction. In Fiscal Year (FY) 25, no new tests were initiated, while 5 previously loaded tests were completed. This report presents an overview of the creep-rupture data gathered at Argonne National Laboratory (ANL) since FY21 that totaled 52 completed tests. Metallographic images showing crack morphologies in some representative samples ruptured in FY25 are also included. Key conclusions include: 1) the creep behavior of the three heats of Alloy 709 can be well described by the Larson-Miller relationship; 2) higher temperatures and larger stresses lead to shorter creep life and higher minimum creep rate; 3) Alloy 709 is overall very ductile under creep; 4) the crack morphologies near fracture surfaces are dependent on material’s grain size and test conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiphysics Simulation of Supercritical CO2 Gasification for Hydrogen Production

A bench-scale supercritical CO2 gasifier is being considered by the U.S. Department of Energy’s National Energy Technology Laboratory (NETL). A reacting computational fluid dynamics (CFD) model was developed using ANSYS/Fluent in order to investigate the impact of various operating parameters on syngas composition. The model was validated using available data in the literature. Simulations were conducted over a range of coal-slurry loadings, reaction temperatures, system pressures, and oxygen mass flowrates with the goal of optimizing hydrogen production for the considered reactor. The results from the simulations identified a positive correlation between slurry loading and hydrogen production, while reactor temperature and pressure had a limited impact on H2 production at the conditions of interest. Additionally, the simulations indicated that oxygen mass flowrate has less of an impact on hydrogen production at higher slurry loadings.

Prlina, Alexander↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

Side-by-Side Comparison of Subhourly Clipping Models: Preprint

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to inter-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of said approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating two different clipping correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons will be performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The models can improve accuracy up to 3% in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

clipping↗

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Deployment of inference as a service at the US CMS Tier-2 data centers

Coprocessors, especially GPUs, will be a vital ingredient of data production workflows at the HL-LHC. At CMS, the GPU-as-a-service approach for production workflows is implemented by the SONIC project (Services for Optimized Network Inference on Coprocessors). SONIC provides a mechanism for outsourcing computationally demanding algorithms, such as neural network inference, to remote servers, where requests from multiple clients are intelligently distributed across multiple GPUs by a load-balancing service. This talk highlights the recent progress in deploying SONIC at selected U.S. CMS Tier-2 data centers. Using realistic CMS Run3 data processing workflows, such as those containing transformer-based algorithms, we demonstrate how SONIC is integrated into the production-like environment to enable accelerated inference offloading. We will present developments from both the client and server sides, including production job and data center configurations for NVIDIA and AMD GPUs. We will also present performance scaling benchmarks and discuss the challenges of operating SONIC in CMS production, such as server discovery, GPU saturation, fallback server logic, etc.

Holzman, Burt↗

Physics-informed Data-driven Degradation and Prognostic For Hydropower System

The hydropower system is a cyber-physical system, and the industry is experiencing high operation and maintenance (O&M) costs along with increasing unplanned outages, primarily due to aging equipment and new asset loading patterns. Current (O&M) practices in asset management are predominantly reactive rather than predictive and systematic. To address these challenges, a proposed physics-informed data-driven degradation model aims to simulate the health of components in various environments. Its purpose is to accurately characterize wear and fatigue in the pilot components of hydropower systems. Additionally, the model provides informed confidence in prognostic predictions concerning asset degradation and remaining life.

13 HYDRO ENERGY↗

Exploration of Domain Aware Machine Learning for Grid Analytics: Transfer-Learnt Energy Models to Assist Buildings Control with Sparse Field Data

Buildings are a primary consumer of energy in the United States and are also increasingly being perceived as providers of grid services such as load shifting, shedding and modulation. High fidelity models of building energy consumption are needed to set appropriate baselines for measurement and verification (M&V) of controllers designed for energy efficient operation of buildings and to enable buildings to provide grid services via. participation in demand response programs. State-of-the-art building energy modeling techniques either rely on Physics based models, or extensive instrumentation of the building envelope to gather “big” data to train machine learning based models such as deep neural networks. While Physics based models are often limited by their accuracy, it is not always feasible to gather a significant amount of field data required to train machine learning based models with sufficient accuracy. In this paper, we explore the use of transfer learning-based strategies to address unsatisfactory accuracy of models for estimating building energy consumption when available field data for training is sparse or of unacceptable quality. In particular, we transfer knowledge in the form of data and parameters, from Physics based simulation frameworks to the field to improve the model accuracy, thus resulting in a Physics-informed Machine Learning framework. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that the proposed transfer learning based models provide comparative (and in some cases better) accuracy than state-of-the-art machine learning and deep learning solutions, with just one month of field data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗

Detecting damage in composites using volume decomposition analysis of tomographic data

Detection of damage in a single tow ceramic matrix composite specimen has been achieved using orthogonal decomposition of volumetric tomographic datasets collected at four tensile loads. This decomposition approach has been applied at two different length scales: (i) individual fibres and (ii) bulk volumes containing fibres and matrix material. Volumes were first decomposed to feature vectors, orders of magnitude smaller than the original volume they describe, and then comparisons between datasets at different load levels were made in feature vector space. The results show quantitative measurements of damage location, damage morphology and the relative growth of this damage with increased load when compared with a dataset with less or no damage. No prior knowledge of the dataset or training of algorithms is required for damage to be detected, it is only necessary that at least two datasets are available for comparison, e.g. from in situ or repeated scanning measurements. Results are generated on significantly shorter timescales when compared with previous automated approaches to tomography data processing. This approach has the potential to be applied to damage detection in a range of materials through comparisons of volumetric datasets from a range of measurement or computational techniques.

Middleton, Ceri A.↗