Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intermittency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

An energy storage dispatch optimization for demand-side management in industrial facilities

An energy storage (ES) dispatch optimization was implemented to test lithium-ion battery ES, supercapacitor ES, and compressed air ES on two different industrial facilities – one intermittent process facility and one continuous process facility. The model first shows the capability of optimizing the size of a single technology on a single industrial facility to maximize the return on investment. Then, for the same profile, the model identifies significant differences in the optimal size for different technologies based on their performance parameters. Third, the model identifies differences in the optimal size for each technology based on the facilities profile. Here the results show compressed air ES yields the highest return on investment for both facilities and provides insight for future development of ES systems.

25 ENERGY STORAGE↗

Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 °C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30°, 45° and 60°) leads to significant temperature differences in the floor, between 57 °C and 62 °C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 °C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.

14 SOLAR ENERGY↗

Computationally efficient models for aqueous organic redox flow batteries

The rising usage of intermittent energy has garnered the need for large scale energy storage systems. Redox flow batteries (RFB) based energy storage system shows promising potential. Numerical simulations and machine learning approaches have been widely used to study RFB performance. The development of autonomous material discovery framework and digital twin of energy storage system usually needs to query cell performance through fast response models. In this study, two computationally efficient models are introduced: a physics-based analytical flow battery model (EZBattery), and a machine learning operator model (Deep Operator Network, denoted by DeepONet). Both models can provide cell performance near instantly, and prediction accuracy was systematically examined on an application of evaluating the performances of a 780 cm 2 aqueous organic redox flow battery (AORFB), using potential anolyte candidates in dihydroxyphenazine (DHP)-based family of organic materials. A validated computationally expansive 3-dimensional multi-physics finite element model by COMSOL was used as the ground truth and provided the training data set for the DeepONet. 1280 samples were generated with 10 properties to mimic the different possible anolyte candidates, and the cell performances were evaluated under 10 different combined operating conditions. The accuracy comparisons for the two computationally efficient models show that both models can provide comparable accuracy in predicting cell charging/discharging voltage curves. DeepONet can provide slightly higher overall accuracy than EZBattery with faster calculation speed, but highly relies on the training dataset. EZBattery does not need a training dataset and can provide interpretable physics-based explanations of the results, while being more flexible to adjust to adapt any different cell designs, flow battery architectures, and electrolyte materials.

Analytical model↗

Experimental investigations on flashing-induced instabilities in one and two-parallel channels: A comparative study

In this investigation, experiments conducted in a natural circulation test facility at low power and low pressure conditions, in the one single and two-parallel channels configuration are presented and discussed in detail. The novel manner of visualizing the results allowed characterizing the facility at any time and position which helped to thoroughly understand the instability mechanisms. Different modes were observed for each configuration. In the case of having two-parallel channels, four different behaviors have been observed: stable flow circulation, periodic high subcooling oscillations, a-periodical oscillations and out-of-phase periodical oscillations. In addition, stability maps were constructed in order to clarify the region in which each mode is dominant. The results obtained from both the one and two-parallel channels configurations are thus analyzed and compared. As a result, some similarities have been observed between the intermittent flow oscillations found in the single channel experiments and the high subcooling oscillations found in the two-parallel channels experiments. Moreover, similarities have also been found between the sinusoidal flow oscillations existing in the single channel experiments and the out-of-phase oscillations from the two-parallel channels experiments. The experiments presented in this work can be used to benchmark numerical codes and modeling techniques developed to study the start-up of natural circulation BWRs. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Odor Mortis

This study, the third of a series on the odor signature of human decomposition, reports on the intermittent nature of chemical evolution from decomposing human remains, and focuses primarily on headspace analysis from soil associated with older human remains (10-60+ years) from different environments around the globe. Fifty grams of soil were collected in 40mL glass vials with polypropylene sealed lids from soil above known or suspected graves and from subsurface chemical plumes associated with human decompositional events. One hundred eighty six separate samples were analyzed using gas chromatography-mass spectrometry (GC-MS). After comparison to relevant soil controls, approximately fifty volatile chemical compounds were identified as being associated with human remains. This manuscript reports these findings and identifies when and where they are most likely to be detected showing an overall decrease in cyclic and halogenated compounds and an increase in aldehydes and alkanes as time progresses. This research identifies the 'odor signatures' unique to the decomposition of human remains with projected ramifications on cadaver dog training procedures and in the development of field portable analytical instruments which can be used to locate human remains in shallow burial sites.

54 ENVIRONMENTAL SCIENCES↗

Making coal relevant for small scale applications: Modular gasification for syngas/engine CHP applications in challenging environments

Small-scale coal gasification technology, coupled to a reciprocating engine generator, has the potential for making coal a cost competitive resource for meeting the flexible energy needs and resiliency requirements of utilities across the United States. To maintain grid stability and reliability, electrical generation must be regulated to match the load at the proper voltage and frequency. With the expansion of intermittent sources into the grid, such as wind and solar, frequency and voltage regulation become increasingly important and challenging. This work presents the results of a Front End Engineering Design (FEED) effort to detail the engineering and preliminary economics of a small-scale, air blown, fixed-bed gasification process, operating at near-atmospheric pressure, with gas cleanup to provide syngas and pyrolysis liquid fuels for use in reciprocating engine generators for combined heat and power at the University of Alaska Fairbanks. A very detailed assessment of capital and operating costs allows the evaluation of a levelized cost of electricity of 208.06 $/MWh, which can be reduced through the selling of by-products (steam for heating purposes and pyrolysis liquids to be used for power generation in an existing diesel engine). Here, a combined sensitivity analysis, based on the Monte Carlo approach, has been carried out to evaluate the effects of the uncertainties (capital and operating costs and plant annual availability) on the LCOE.

01 COAL, LIGNITE, AND PEAT↗

Utilization of an Advanced Sensor network to determine fuel heating value and Real-Time net unit heat rate during transient operation

Coal-fired utility boilers are being increasingly used as variable electricity generation to resolve the imbalance in the energy market from the expansion of intermittent renewable energy. The frequent transient operation required to meet residual energy demand has created a challenge for coal-fired units to operate efficiently. This work utilizes an advanced sensor network (ASN) to calculate net unit heat rate (NUHR) of a coal-fired boiler in real time through combustion calculations and statistical correlations to provide the tools for optimizing dynamic operation. Real-time heating values that were necessary to determine fuel input energy to calculate accurate NUHR were found using both fundamental and data-driven methods. Real-time NUHR shows distinct shifts that reflect changes in process conditions that will improve the ability to optimize transient operation. Data-driven heating value correlations had 24% lower root mean square error (RMSE) than the fundamental combustion calculation approach when compared to daily retrospective proximate analysis. Furthermore, the data-driven method RMSE improved by 7% with the inclusion of ASN data. Future work is to validate by comparing unit performance with and without the inclusion of NUHR as a control parameter for the dynamic neural network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fluidization and drying of biomass particles in a vibrating fluidized bed with pulsed gas flow

Fluidization of biomass particles in the absence of inert bed materials has been tested in a pulsed fluidized bed with vibration, with the pulsation frequency ranging from 033 to 6.67 Hz. Intermittent fluidization at 033 Hz and apparently 'normal' fluidization at 6.67 Hz with regular bubble patterns were observed. Pulsation has proven to be effective in overcoming the bridging of irregular biomass particles induced by strong inter-particle forces. The vibration is only effective when the pulsation is inadequate, either at too low a frequency or too low in amplitude. We dried biomass in order to quantify the effectiveness of gas pulsation for fluidized bed dryers and torrefiers in terms of gas-solid contact efficiency and heat and mass transfer rates. Furthermore, the effects of gas flow rate, bed temperature, pulsation frequency and vibration intensity on drying performance have been systematically investigated. While higher temperature and gas flow rate are favored in drying, there exists an optimal range of pulsation frequency between 0.75 Hz and 1.5 Hz where gas-solid contact is enhanced in both the constant rate drying and falling rate drying periods.

09 BIOMASS FUELS↗

Workflow-based automatic processing for Internet of Floating Things crowdsourced data

Data from sensors incorporated into mobile devices, such as networked navigational sensors, can be used to capture detailed environmental information. We describe here a workflow and framework for using sensors on boats to construct unique new datasets of underwater topography (bathymetry). Starting with a large number of measurements of position, depth, etc., obtained from such an Internet of Floating Things, we illustrate how, with a specialized protocol, data can be communicated to cloud resources, even when using delayed, intermittent, or disconnected networks. We then propose a method for automatic sensor calibration based on a novel reputation approach. Sampled depth data are interpolated efficiently on a cloud computing platform in order to provide a continuously updated bathymetric database. Our prototype implementation uses the FACE-IT Galaxy workflow engine to manage network communication and exploits the computational power of GPGPUs in a virtualized cloud environment, working with a CUDA-parallel algorithm, for efficient data processing. We report on an initial evaluation involving data from a sailing vessel in Italian coastal waters.

97 MATHEMATICS AND COMPUTING↗

Sulfur, iron-, and calcium cycling associated with natural electric currents running through marine sediment

Anaerobic oxidation of organic matter in marine sediment is traditionally considered to be coupled to oxygen reduction via a cascade of redox processes and transport of intermittent electron donors and acceptors. Long distance electron transmission (LDET) has recently been shown to shortcut this cascade and directly couple oxygen reduction at the surface to sulphide oxidation in deeper anoxic layers. Here we show that spatial separation of oxidation and reduction processes in marine sediment causes non-conventional sulphur, iron, and calcium cycling. Reduced sediment was incubated with overlying oxic water and the vertical distribution of solutes and solids analysed 45 days later. As much as 44% of sediment oxygen consumption proved to be mediated by LDET, and electrogenic oxidation of sulphide to sulphate resulted in significant dissolution of iron sulphides and calcium carbonates in the anoxic layers of the sediment. Most of the mobilised iron diffused to the oxic zone where it formed oxidised iron minerals. Calcium precipitated out in the oxic zone as magnesium-calcite. In marine sediment, LDET thus generates unique chemical conditions whereby key minerals are mobilised and relocated, probably along with trace elements and nutrients. We suggest that LDET flourishes in marine sediments after transient oxygen depletion, leaving distinct signatures of such events in the geological record.

54 ENVIRONMENTAL SCIENCES↗

Effective kinetics driven by dynamic concentration gradients under coupled transport and reaction

Biogeochemical reaction kinetics are generally established from batch reactors where concentrations are uniform. In natural systems, many biogeochemical processes are characterized by spatially and temporally variable concentration gradients that often occur at scales which are not resolved by field measurements or biogeochemical and reactive transport models. Yet, it is not clear how these sub-scale chemical gradients affect reaction kinetics compared to batch kinetics. Here we investigate this question by studying the paradigmatic case of localized pulses of solute reacting with a solid or a dissolved species in excess. Additionally, we consider non-linear biogeochemical reactions, representative of mineral dissolution, adsorption and redox reactions, which we quantify using simplified power-law kinetics. The combined effect of diffusion and reaction leads to effective kinetics that differ quantitatively and qualitatively from the batch kinetics. Depending on the nonlinearity (reaction order) of the local kinetics, these effects lead to either enhancement or decrease of the overall reaction rate, and result in a rich variety of reaction dynamics. We derive analytical results for the effective kinetics, which are validated by comparison to direct numerical simulations for a broad range of Damköhler numbers and reaction order. Our findings provide new insights into the interpretation of imperfectly mixed lab experiments, the effective kinetics of field systems characterized by intermittent reactant release and the integration of sub-scale concentration gradients in reactive transport models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of curtailment at The Geysers geothermal Field, California

Geothermal energy has traditionally been viewed as a baseload energy source, but the rapid growth of intermittent renewable energy has led to a need for more flexibility in power generation to avoid mandatory curtailment imposed by grid operators. This study of curtailment at The Geysers provides insights into the magnitude, duration, frequency, temporal and spatial distribution, and potential causes of curtailment events between 2013 and 2018. Annual levels of curtailment range during this period from 9 to 47 GW h, representing 0.15 to 0.81 % of the net generation. Most curtailments occurred at the power plants connected to a lower capacity transmission line and may result from transmission constriction. There is a clear link between negative pricing and economic curtailment, especially when solar production is higher. Economic curtailment events tend to be only a few hours and vary in magnitude up to almost 300 MW, whereas transmission-related curtailment events can be up to several weeks in duration. It is likely that curtailment of geothermal power will be an increasing concern, and could be mitigated by flexible generation strategies and increases in energy storage. It is critical to know the nature of curtailment events so that flexible generation options can be assessed properly.

15 GEOTHERMAL ENERGY↗

Analysis of Neptune’s 2017 bright equatorial storm

Herein we report the discovery of a large (~8500 km diameter) infrared-bright storm at Neptune’s equator in June 2017. We tracked the storm over a period of 7 months with high-cadence infrared snapshot imaging, carried out on 14 nights at the 10 m Keck II telescope and 17 nights at the Shane 120 inch reflector at Lick Observatory. The cloud feature was larger and more persistent than any equatorial clouds seen before on Neptune, remaining intermittently active from at least 10 June to 31 December 2017. Our Keck and Lick observations were augmented by very high-cadence images from the amateur community, which permitted the determination of accurate drift rates for the cloud feature. Its zonal drift speed was variable from 10 June to at least 25 July, but remained a constant 237.4 ± 0.2 m s – 1 from 30 September until at least 15 November. The pressure of the cloud top was determined from radiative transfer calculations to be 0.3-0.6 bar; this value remained constant over the course of the observations. Multiple cloud break-up events, in which a bright cloud band wrapped around Neptune’s equator, were observed over the course of our observations. No “dark spot” vortices were seen near the equator in HST imaging on 6 and 7 October. The size and pressure of the storm are consistent with moist convection or a planetary-scale wave as the energy source of convective upwelling, but more modeling is required to determine the driver of this equatorial disturbance as well as the triggers for and dynamics of the observed cloud break-up events.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Optimization of adsorption processes for climate control and thermal energy storage

Adsorption based heat-pumps have received significant interest owing to their promise of higher efficiencies and energy savings when coupled with waste heat and solar energy compared to conventional heating and cooling systems. While adsorption systems have been widely studied through computational analysis and experiments, general design guidelines to enhance their overall performance have not been proposed. In this work, we identified conditions suitable for the maximum utilization of the adsorbent to enhance the performance of both intermittent as well as continuously operating adsorption systems. A detailed computational model was developed based on a general framework governing adsorption dynamics in a single adsorption layer and pellet. We then validated the computational analysis using experiments with a model system of zeolite 13X-water for different operating conditions. A dimensional analysis was subsequently carried out to optimize adsorption performance for any desired operating condition, which is determined by the choice of adsorbent-vapor pair, adsorption duration, operational pressure, intercrystalline porosity, adsorbent crystal size, and intracrystalline vapor diffusivity. The scaling analysis identifies the critical dimensionless parameters and provides a simple guideline to determine the most suitable geometry for the adsorbent particles. Based on this selection criterion, the computational model was used to demonstrate maximum utilization of the adsorbent for any given operational condition. By considering a wide range of parametric variations for performance optimization, these results offer important insights for designing adsorption beds for heating and cooling systems. (C) 2014 Elsevier Ltd. All rights reserved.

Narayanan, S↗

Process intensification approach to enhancing heat and mass transfer during drying: Ultrasonic (US) assisted drying of paper and board

Drying of paper and board is conventionally achieved through alternating conduction (steam-heated cylinders) and pocket convection (heated air over the paper web surface). These conventional drying systems rely heavily on steam from fossil fuels, resulting in inefficiencies, high energy usage, and thermal losses due to surface-driven mechanisms. Here, to address these challenges, an experimental system, with in-situ drying characteristics measurements, was developed to investigate process intensification using ultrasonic-based dewatering—a volumetric, pressure-driven acoustic energy system—integrated with conventional drying. The objectives of this study are to assess the impact of ultrasonics (US) on dewatering; compare performances to conventional drying systems; identify improvements in drying rate and energy use as a function of moisture content; and gain potential insights on heat and mass transfer mechanisms during US-assisted drying. US performance was evaluated across frequencies, power levels, pulp types, and basis weights. Results show that improvements to ultrasonic applications in conjunction with convection were 30-43% in drying rate and 20-35% in drying time over continuous and intermittent applications. When combined with conduction and convection, ultrasonics yielded up to 20% improvement in both rate and time and up to 20% reduction in energy consumption. Observations support a hypothesis of extension of the constant rate period due to improved capillary flow at higher moisture content and enhancing vapor diffusion and boundary layer disruption at lower moisture contents during falling rate period. These findings will inform future modeling, simulation, design and optimization of advanced drying systems.

42 ENGINEERING↗

Optimization of metal-supported solid oxide electrolysis cells with infiltrated catalysts

We report metal-supported solid oxide electrolysis cells (MS-SOECs) are being developed for steam-to-hydrogen electrolysis, especially for utilization of dynamic or intermittent electrical power from renewable sources. Various aspects of the electrocatalyst processing and composition, and metal support structure were explored. Catalyst materials, infiltration temperature and infiltration cycles were optimized for high performance and durability. Numerous catalyst materials were screened for both oxygen and steam electrodes. The oxygen catalyst had moderate impact on both initial cell performance and durability. Reducing Ni content in the steam electrode had little effect on durability, but reduced initial performance. Ex-situ XRD analysis and cell assessment of catalyst infiltration temperature revealed that the optimal range is 750–850 °C. The best cell performance and durability was achieved with LSCF-SDC oxygen electrocatalyst and SDC-Ni (60:40 vol%) steam electrocatalyst infiltrated 11 times at 800 °C and operated at 700 °C. At low steam content, a significant mass transport limitation on the steam side results in limiting current behavior. Thinner and more porous metal supports were implemented, and found to improve steam mass transport at low steam content, relevant for SOECs operating under high H 2 recycle rate or high steam utilization.

08 HYDROGEN↗