Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Initial cone-in-shell fast-ignition experiments on OMEGA

Fast ignition is a two-step inertial confinement fusion concept where megaelectron volt electrons ignite the compressed core of an imploded fuel capsule driven by a relatively low-implosion velocity. Initial surrogate cone-in-shell, fast-ignitor experiments using a highly shaped driver pulse to assemble a dense core in front of the cone tip were performed on the OMEGA/OMEGA EP Laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997); L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)]. With optimal timing, the OMEGA EP pulse produced up to {approx}1.4 x 10{sup 7} additional neutrons which is a factor of {approx}4 more neutrons than without short-pulse heating. Shock-breakout measurements performed with the same targets and drive conditions demonstrate an intact cone tip at the time when the additional neutrons are produced. Velocity interferometer system for any reflector measurements show that x-rays from the shell's coronal plasma preheat the inner cone wall of thin-walled Au cones, while the thick-walled cones that are used in the integrated experiments are not affected by preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and characterization of optical heads for interferometric ballistic velocity measurements

The design of optical fiber based heads offering high accuracy and bandwidth for use in VISAR (velocity interferometer system for any reflector) experiments measuring ballistic velocities is described. A new, expanded, model for predicting the distance-dependent collection efficiency of the heads is presented. The model is shown to agree very well with experimental results, both within and outside the ''depth of field''. Various optical heads are demonstrated, to suit different experimental setups and conditions. Designs offering options for high bandwidths, accurate prealignment, and large stand-off distances are discussed. Results from a typical VISAR experiment are presented, verifying that our designs yield high-quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structured scintillator for hard x-ray grating interferometry

Grating interferometry at conventional x-ray tubes improves the quality of radiographies and tomograms by providing phase and scattering contrast data. The main challenge encountered when applying this technique at high photon energies, as required by many applications to obtain sufficient penetration depth, is to maintain a high fringe visibility. In this letter, we report on a substantial improvement in fringe visibility and according improvements in image quality achieved by replacing the absorbing analyzer grating of the interferometer with a structured scintillator grating. This development represents a significant step toward the implementation of this technique in industrial testing and medical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed nano-metrology

For manufacturing at the nanometre scale a method for rapid and accurate measurement of the resultant functional devices is required. Although atomic force microscopy (AFM) has the requisite spatial resolution, it is severely limited in scan speed, the resolution and repeatability of vertical and lateral measurements being degraded when speed is increased. Here we present a new approach to AFM that makes a direct and feedback-independent measurement of surface height using a laser interferometer focused onto the back of the AFM tip. Combining this direct height measurement with a passive, feedback-free method for maintaining tip-sample contact removes the constraint on scan speed that comes from the bandwidth of the z-feedback loop. Conventional laser reflection detection is used for feedback control, which now plays the role of minimising tip-sample forces, rather than producing the sample topography. Using the system in conjunction with a rapid scanner, true height images are obtained with areas up to (36 x 36) {mu}m{sup 2} at 1 image/second, suitable for in-line applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of laser-induced periodic surface structures on fused silica upon multiple cross-polarized double-femtosecond-laser-pulse irradiation sequences

The formation of laser-induced periodic surface structures (LIPSS) upon irradiation of fused silica with multiple irradiation sequences consisting of five Ti:sapphire femtosecond (fs) laser pulse pairs (150 fs, 800 nm) is studied experimentally. A Michelson interferometer is used to generate near-equal-energy double-pulse sequences with a temporal pulse delay from -20 to +20 ps between the cross-polarized individual fs-laser pulses ({approx}0.2 ps resolution). The results of multiple double-pulse irradiation sequences are characterized by means of Scanning Electron and Scanning Force Microscopy. Specifically in the sub-ps delay domain striking differences in the surface morphologies can be observed, indicating the importance of the laser-induced free-electron plasma in the conduction band of the solids for the formation of LIPSS.

36 MATERIALS SCIENCE↗

High resolution 3D gas-jet characterization

We present a tomographic characterization of gas jets employed for high-intensity laser-plasma interaction experiments where the shape can be non-symmetrically. With a Mach-Zehnder interferometer we measured the phase shift for different directions through the neutral density distribution of the gas jet. From the recorded interferograms it is possible to retrieve 3-dimensional neutral density distributions by tomographic reconstruction based on the filtered back projections. We report on criteria for the smallest number of recorded interferograms as well as a comparison with the widely used phase retrieval based on an Abel inversion. As an example for the performance of our approach, we present the characterization of nozzles with rectangular openings or gas jets with shock waves. With our setup we obtained a spatial resolution of less than 60 {mu}m for an Argon density as low as 2 x 10{sup 17} cm{sup -3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-Planck structures and Quantum Metrology

The significance of sub-Planck structures in relation to quantum metrology is explored, in close contact with experimental setups. It is shown that an entangled cat state can enhance the accuracy of parameter estimations. The possibility of generating this state, in dissipative systems has also been demonstrated. Thereafter, the quantum Cramer-Rao bound for phase estimation through a pair coherent state is calculated, which achieves the maximum possible resolution in an interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multimode terahertz-wave generation using coherent Cherenkov radiation

Multimode terahertz(THz)-wave generation using coherent Cherenkov radiation (CCR) was investigated. The frequency spectra of CCR, which utilized a metal-wrapped hollow dielectric tube of 7 mm outer radius and a picosecond electron bunch of 27 MeV beam energy, were measured by a Michelson interferometer with a 4.2 K silicon bolometer. In this study, discrete spectral components at frequencies of 0.09, 0.14, and 0.36 THz were observed experimentally and explained as transverse magnetic (TM) modes of TM{sub 03}, TM{sub 04}, and TM{sub 09}, respectively, according to a theoretical calculation for the tube.

43 PARTICLE ACCELERATORS↗

Note: Frequency-conversion photonic Doppler velocimetry with an inverted circulator

Photonic Doppler velocimetry (PDV) is a fiber-based interferometer used in dynamic compression research. Conventional PDV systems are simple to construct but do not perform well in all measurement conditions, while universal PDV systems that support many different configurations are complex and expensive. A simpler approach is the use of external, inverted circulators which can be added and removed in a modular fashion. This technique permits frequency-conversion measurements with a conventional PDV system. Using a correction to remove baseline effects, frequency conversion systems can resolve low velocity transients that conventional PDV cannot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-chord fiber-coupled interferometry of supersonic plasma jets andcomparisons with synthetic data

A multi-chord fiber-coupled interferometer [Merritt et al., Rev. Sci. Instrum. 83, 033506 (2012)] is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment [Hsu et al., Bull. Amer. Phys. Soc. 56, 307 (2011)]. The long coherence length of the laser (> 10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which an initially positive phase shift becomes negative when the ionization fraction drops below a certain threshold. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx} 15-50 km/s), jet length ({approx} 20-100 cm), and 3D expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with {approx}8 cm spacing. The source is a 432 {mu}m (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub Up-Tack} < 1.3 cm{sup -1}, corresponding k{sub Up-Tack }{rho}{sub s} < 1.3 ({rho}{sub s} is the ion-sound Larmor radius), the region of primary interest for turbulent fluctuation-induced transport. The perpendicular wavenumber consists of toroidal, poloidal, and radial contributions, which vary with chord position. Coherent modes associated with tearing instabilities and neutral-beam driven fast particles are observed along with broadband turbulence at frequencies up to 500 kHz. Changes in frequency are consistent with a Doppler shift due to parallel plasma flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Core density gradient fluctuation measurement by differential interferometry in the helically symmetric experiment stellarator

The interferometer system on the Helically Symmetric eXperiment (HSX) stellarator uses an expanded beam and linear detector array to realize a multichord measurement. Unlike conventional interferometry which determines the plasma phase shift with respect to a reference, directly evaluating the phase between two adjacent chords can be employed to measure the change in plasma phase with impact parameter. This approach provides a measure of the equilibrium density gradient or the density gradient fluctuations and is referred to as differential interferometry. For central chords, measurements are spatially localized due to a geometrical weighting factor and can provide information on core density gradient fluctuations. The measurement requires finite coherence between fluctuations in the two spatially offset chords. This technique is applied on the HSX stellarator to measure both broadband turbulence and coherent modes. Spatial localization is exploited to isolate core turbulence changes associated with change in magnetic configuration or heating location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-chord fiber-coupled interferometry of supersonic plasma jets (invited)

A multi-chord fiber-coupled interferometer is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment. The long coherence length of the laser (>10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which both positive and negative phase shift values are observed depending on the ionization fraction. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx}15-50 km/s), jet length ({approx}20-100 cm), and 3D expansion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron density and temperature profile diagnostics for C-2 field reversed configuration plasmas

The 9-point Thomson scattering diagnostic system for the C-2 field reversed configuration plasmas is improved and the measured electron temperature profiles are consistent with theoretical expectations. Rayleigh scattering revealed a finite line width of the ruby laser emission, which complicates density calibration. Taking advantage of the plasma wobble motion, density profile reconstruction accuracy from the 6-chord two-color CO{sub 2}/HeNe interferometer data is improved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of neutral density profiles using a deuterium Balmer-alpha diagnostic in the C-2 FRC plasma

In C-2 field-reversed configuration (FRC) device, low neutral density outside the FRC separatrix is required to minimize the charge exchange loss of fast particles. Titanium gettering is used in C-2 to reduce the wall recycling and keep the neutral density low in plasma edge. The measurements of neutral density radial profile are desirable to understand the plasma recycling and the effects of titanium gettering. These measurements are also needed to study the interaction of neutral beams with FRC plasma and confinement of fast ions. Diagnostic based on absolute deuterium Balmer-alpha (D-alpha) radiation measurements is developed and deployed on C-2 device to measure the radial profile of neutral density. Simultaneous measurements of electron density and temperature are done using CO{sub 2} interferometer, Thomson scattering, and triple probes diagnostics along with absolute D-alpha radiation. Abel inversion was performed to get the time dependent radial profile of the local D-alpha emission density. Neutral density profiles are obtained under different machine conditions of titanium deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards nanometer period gratings for hard x-ray phase-contrast imaging

Transmission grating-based x-ray interferometers have been developed into wide-field imaging devices that are sensitive to x-ray refraction and diffraction in the sample. While current grating designs rely on UV and x-ray lithography processes to produce periodic vertical structures, it becomes prohibitively difficult to make the grating periods below 1 - 2 microns due to the high aspect ratios of the structures. Since the phase-contrast sensitivity is inversely related to the grating period, we describe a new grating design for sub-micron to nanometer grating periods. In this design, multiple bi-layers of two alternating materials are deposited on a stair like substrate, and mostly on the floor surfaces of the steps only. The incident x-ray beam is parallel to the planes of the layers (side illumination). Thus, the multilayer structure on each step serves as a micro grating whose grating period is the thickness of a bi-layer. The array of micro gratings over the whole length of the stair can act as a single continuous grating, when certain continuity conditions between neighboring steps are met. Since the layer thickness can be as small as tens of nanometers, as has been demonstrated in multilayer x-ray zone plates, this design allows nanometer grating periods over large grating areas. Here we describe a prototype intensity grating of 440 nm period. We show x-ray projection images of the grating which were obtained by contact lithography.

36 MATERIALS SCIENCE↗

X-ray phase imaging-From static observation to dynamic observation-

We are attempting to expand the technology of X-ray grating phase imaging/tomography to enable dynamic observation. X-ray phase imaging has been performed mainly for static cases, and this challenge is significant since properties of materials (and hopefully their functions) would be understood by observing their dynamics in addition to their structure, which is an inherent advantage of X-ray imaging. Our recent activities in combination with white synchrotron radiation for this purpose are described. Taking advantage of the fact that an X-ray grating interferometer functions with X-rays of a broad energy bandwidth (and therefore high flux), movies of differential phase images and visibility images are obtained with a time resolution of a millisecond. The time resolution of X-ray phase tomography can therefore be a second. This study is performed as a part of a project to explore X-ray grating interferometry, and our other current activities are also briefly outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design aspects of X-ray grating interferometry

Considerations are made for the design of X-ray grating interferometers in general and, in particular, for the case of a parallel beam with a high degree of spatial coherence. We specifically discuss the properties of different types of gratings and the interdependence of instrument parameters and performance characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗