Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interconnection networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

The git based ATLAS data acquisition configuration service in LHC Run 3

The ATLAS experiment at the LHC at CERN uses a large, distributed trigger and data acquisition system composed of many computing nodes, networks, and hardware modules. Its configuration service is used to provide descriptions of control, monitoring, diagnostic, recovery, dataflow and data quality configurations, interconnections, and parameters for modules, chips, and channels of various online systems, detectors, and the whole ATLAS experiment. Those descriptions have historically been stored in more than one thousand interconnected XML files, which are updated by various experts many times per day. Maintaining error-free and consistent sets of such files and providing reliable and fast access to current and historical configurations is a major challenge. This paper gives details of the configuration service upgrade on the modern Git version control system backend for LHC Run 3 and its exploitation experience. It may be interesting for developers using human-readable file formats, where consistency of the files, performance, access control, traceability of modifications, and effective archiving are key requirements.

Soloviev, Igor [Univ. of California, Irvine, CA (U↗

International organizations to enable world-wide mobile satellite services

Numbers of systems exist or have been proposed to provide world-wide mobile satellite services (MSS). Developers of these systems have formulated institutional structures they consider most appropriate for profitable delivery of these services. MSS systems provide niche services and complement traditional telecommunications networks; they are not integrated into world-wide networks. To be successful, MSS system operators must be able to provide an integrated suite of services to support the increasing globalization, interconnectivity, and mobility of business. The critical issue to enabling 'universal roaming' is securing authority to provide MSS in all of the nations of the world. Such authority must be secured in the context of evolving trends in international telecommunications, and must specifically address issues of standardization, regulation and organization. Today, only one existing organization has such world-wide authority. The question is how proponents of new MSS systems and services can gain similar authority. Securing the appropriate authorizations requires that these new organizations reflect the objectives of the nations in which services are to be delivered.

Anglin, Richard L., Jr.↗

Systems and methods for rapid processing and storage of data

Systems and methods of building massively parallel computing systems using low power computing complexes in accordance with embodiments of the invention are disclosed. A massively parallel computing system in accordance with one embodiment of the invention includes at least one Solid State Blade configured to communicate via a high performance network fabric. In addition, each Solid State Blade includes a processor configured to communicate with a plurality of low power computing complexes interconnected by a router, and each low power computing complex includes at least one general processing core, an accelerator, an I/O interface, and cache memory and is configured to communicate with non-volatile solid state memory.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for rapid processing and storage of data

Systems and methods of building massively parallel computing systems using low power computing complexes in accordance with embodiments of the invention are disclosed. A massively parallel computing system in accordance with one embodiment of the invention includes at least one Solid State Blade configured to communicate via a high performance network fabric. In addition, each Solid State Blade includes a processor configured to communicate with a plurality of low power computing complexes interconnected by a router, and each low power computing complex includes at least one general processing core, an accelerator, an I/O interface, and cache memory and is configured to communicate with non-volatile solid state memory.

Stalzer, Mark A.↗

Systems and methods for rapid processing and storage of data

Systems and methods of building massively parallel computing systems using low power computing complexes in accordance with embodiments of the invention are disclosed. A massively parallel computing system in accordance with one embodiment of the invention includes at least one Solid State Blade configured to communicate via a high performance network fabric. In addition, each Solid State Blade includes a processor configured to communicate with a plurality of low power computing complexes interconnected by a router, and each low power computing complex includes at least one general processing core, an accelerator, an I/O interface, and cache memory and is configured to communicate with non-volatile solid state memory.

Stalzer, Mark A.↗

Concurrent communication among multi-transceiver stations over shared media

In order to increase a local-area network's throughput beyond a single bus data rate without using dedicated switching nodes, multiple buses and multitransceiver stations are required. The design space of single-hop interconnections is explored among such stations. Interconnections are presented whose throughput can grow quadratically with the number of transmitters and receivers per station. These are referred to as selective broadcast interconnections (SBIs). The performance of various SBIs are studied. A spread-spectrum channel can accommodate several current successful transmission, and a single-transceiver node can thus utilize only a small fraction of the channel capacity. In order to allocate the appropriate fraction of capacity to a busy node, it is proposed to equip it with several transmitters and receivers, thereby turning it into a supernode. Several architectures and operation policies for supernodes are suggested and compared. It is shown that a supernode can significantly outperform a collection of independent conventional nodes with the same total numbers of transmitters and receivers. Packet-radio networks with half-duplex nodes, as well as networks with full-duplex nodes, are considered.

Birk, Yitzhak↗

Nanofibrous electrocatalyst including nanofibrous continuous network of graphitic nanofibers having embedded catalytically active metal moieties

A nanofibrous catalyst and method of manufacture. A precursor solution of a transition metal based material is formed into a plurality of interconnected nanofibers by electro-spinning the precursor solution with the nanofibers converted to a catalytically active material by a heat treatment. Selected subsequent treatments can enhance catalytic activity.

36 MATERIALS SCIENCE↗

ESR, optical absorption, IR and Raman studies of xTeO{sub 2} + (70 - x)B{sub 2}O{sub 3} + 5TiO{sub 2} + 24R{sub 2}O:1CuO (x = 10, 35 and 60 mol%; R = Li, Na and K) quaternary glass system

Highlights: Black-Right-Pointing-Pointer Peak of Cu{sup 2+} is found to be maximum at around 794 nm for lithium boro tellurite glasses. Black-Right-Pointing-Pointer Variation in g{sub ||} and A{sub ||} values is due to change in environment of Cu{sup 2+} ion due to the structural change in the glass. Black-Right-Pointing-Pointer BO{sub 3}-BO{sub 4}{sup -} ring structure is interconnected by TeO{sub 3}{sup -} and TeO{sub 4}{sup -} groups, where the BO{sub 4}{sup -} groups are neighbors of TeO{sub 3}{sup -}groups. Black-Right-Pointing-Pointer The structure comprising, isolate a BO{sub 3}{sup -}, B{sub 2}O{sub 5}, BO{sub 4}{sup -}, and metaborates, which enables glass forming for Borate rich glasses. Black-Right-Pointing-Pointer Distorted TeO{sub 4/2} network with BO{sub 3}{sup -}-BO{sub 4}{sup -} ring structure and TeO{sub 3}{sup -} group is enables glass forming for tellurite rich glasses. -- Abstract: xTeO{sub 2} + (70 - x)B{sub 2}O{sub 3} + 5TiO{sub 2} + 24R{sub 2}O:1CuO (x = 10, 35 and 60; R = Li, Na and K) glass system were studied by spectroscopic techniques such as ESR, optical absorption, Raman and IR. From ESR spectra, the spin Hamiltonian parameter values indicate that the ground state of Cu{sup 2+} is d{sub x{sup 2}-y{sup 2}} and the site symmetry around the Cu{sup 2+} ion is tetragonally distorted octahedral coordination. Bonding parameters calculated from optical absorption and ESR data are found to change with alkali oxide and TeO{sub 2} content. Bonding parameters indicate a slight covalency for the in-plane {sigma} bonding as compared to in-plane and out-of-plane {pi} bonds. Both Raman and IR results show that glass network consists of TeO{sub 3}, TeO{sub 4}, BO{sub 3}, BO{sub 4} and RiO{sub 4} group as basic structural groups. BO{sub 3}-BO{sub 4}{sup -} ring structure interconnected by TeO{sub 3}{sup -} and TeO{sub 4}{sup -} groups, where the BO{sub 4}{sup -} groups are neighbors of the TeO{sub 3}{sup -} groups. BO{sub 3} {yields} BO{sub 4} transition is also observed, which correlates with the transition of TeO{sub 4} {yields} TeO{sub 3} via TeO{sub 3+1}.

36 MATERIALS SCIENCE↗

Resilient Cooperative Voltage Control for Distribution Network with High Penetration Distributed Energy Resources

Here, this paper considers the problem of designing a resilient distributed voltage control algorithm for distribution systems with high penetration of distributed energy resources in the presence of an unknown cyber-attack. The purpose of the attack is to force the system to violate the operating voltage limit by intercepting its communication channels and inserting exogenous signals to perturb and/or modify the information being exchanged. We first review the cooperative voltage control proposed in our previous work and provide a new stability analysis for it. Next, we present a resilient cooperative voltage control algorithm by introducing a virtual system interconnected with the original system such that the voltage can be maintained within the operational limit under unknown attacks. The resiliency of the proposed algorithm is demonstrated via simulations on the IEEE 8500-node system when subjected to an attack which consists of corrupting the data being exchanged in the communication network between two generation units.

cooperative control↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Site specific porosity-thermal performance correlations in neutron irradiated U-10Zr fuel

In this work, we present a site-specific three-dimensional analysis of porosity evolution in neutron-irradiated U–10Zr metallic fuel using high-resolution synchrotron X-ray tomography. Focused ion beam cubic lift-outs from four radial positions—fuel center, middle, edge, and fuel-cladding interaction (FCCI) zones—were imaged, reconstructed, and segmented to quantify pore volume, density, morphology, and pore connectivity. Porosity increased modestly from 5.5% at the center to 10.5% at the edge, yet pore number density increased by over two orders of magnitude in the fuel portion near the FCCI interface (from 4.8 x 10 4 to 6.0 x 10 6 pores/mm 3 ). Morphological classification revealed a progression from small spherical pores at the center to equiaxed and tortuous networks at the periphery, with enhanced orientation along the radial direction. Connectivity and permeability analysis reveal that the FCCI region maintains dense, highly interconnected pores despite a moderate volume fraction, enabling rapid fission gas transport and lanthanide migration. Effective thermal conductivity models incorporating sodium logging confirm that these site-specific pore features critically influenced heat transport during reactor irradiation. These findings demonstrate that pore topology—not just porosity fraction—controls thermal performance and thermal pathways in U–10Zr fuels, impacting fuel thermal performance in a reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A distributed telerobotics system for space operations

Robotic systems for space operations will require a combination of teleoperation, closely supervised autonomy, and loosely supervised autonomy. They may involve multiple robots, multiple controlling sites, and long communication delays. We have constructed a distributed telerobotics system as a framework for studying these problems. Our system is based on a modular interconnection scheme which allows the components of either manual or autonomous control systems to communicate and share information. It uses a wide area network to connect robots and operators at several different sites. This presentation will describe the structure of our system, the components used in our configurations, and results of some of our teleoperation experiments.

Wise, James D.↗

Using manufacturing message specification for monitor and control at Venus

The flexibility and robustness of a monitor and control (M&C) system are a direct result of the underlying interprocessor communications architecture. A new architecture for M&C at the Deep Space Communications Complexes (DSCC's) has been developed based on the Manufacturing Message Specification (MMS) process control standard of the Open System Interconnection (OSI) suite of protocols. This architecture has been tested both in a laboratory environment and under operational conditions at the Deep Space Network (DSN) experimental Venus station (DSS-13). The Venus experience in the application of OSI standards to support M&C has been extremely successful. MMS meets the functional needs of the station and provides a level of flexibility and responsiveness previously unknown in that environment. The architecture is robust enough to meet current operational needs and flexible enough to provide a migration path for new subsystems. This paper will describe the architecture of the Venus M&C system, discuss how MMS was used and the requirements this imposed on other parts of the system, and provide results from systems and operational testing at the Venus site.

Heuser, W. Randy↗

DSS-13 - Using an OSI process control standard for monitor and control

The flexibility and robustness of a monitor and control (M&C) system are a direct result of the underlying inter-processor communications architecture. A new architecture for M&C at the Deep Space Communications Complexes has been developed based on the manufacturing message specification (MMS) process control standard of the open system interconnection (OSI) suite of protocols. This architecture has been tested both in a laboratory environment and under operational conditions at the Deep Space Network experimental station (DSS-13). The DSS-13 experience in the application of OSI standards to support M&C has been extremely successful. MMS meets the functional needs of the station and provides a level of flexibility and responsiveness previously unknown in that environment. The architecture is robust enough to meet current operational needs and flexible enough to provide a migration path for new subsystems. This paper describes the architecture of the DSS-13 M&C system, discuss how MMS was used and the requirements this imposed on other parts of the system, and provides results from systems and operational testing at DSS-13.

Heuser, W. R.↗

Numerical Modeling of the Chilldown of Cryogenic Transfer Lines Using a Sinda/GFSSP Integrated Solver

An important first step in cryogenic propellant loading is the chilldown of transfer lines. During the chilldown of the transfer line, the flow is two-phase and unsteady, with solid to fluid heat transfer and therefore a coupled thermo-fluid analysis is necessary to model the system. This paper describes a numerical model of pipe chilldown that utilizes the Sinda/GFSSP Conjugate Integrator (SGCI). SGCI is a new analysis tool developed at NASA's Marshall Space Flight Center (MSFC). SGCI facilitates the solution of thermofluid problems in interconnected solid-fluid systems. The solid component of the system is modeled in MSC Patran and translated into an MSC Sinda thermal network model. The fluid component is modeled in GFSSP, the Generalized Fluid System Simulation Program. GFSSP is a general network flow solver developed at NASA/MSFC. GFSSP uses a finite-volume approach to model fluid systems that can include phase change, multiple species, fluid transients, and heat transfer to simple solid networks. SGCI combines the GFSSP Fortran code with the Sinda input file and compiles the integrated model. Sinda solves for the temperatures of the solid network, while GFSSP simultaneously solves the fluid network for pressure, temperature, and flow rate. The two networks are coupled by convection heat transfer from the solid wall to the cryogenic fluid. The model presented here is based on a series of experiments conducted in 1966 by the National Bureau of Standards (NBS). A vacuum-jacketed, 200 ft copper transfer line was chilled by liquid nitrogen and liquid hydrogen. The predictions of transient temperature profiles and chilldown time of the integrated Sinda/GFSSP model will be compared to the experimental measurements.

LeClair, Andre↗

DSS-13: Using an OSI Process Control Standard for Monitor & Control

The flexibility and robustness of a monitor and control (M&C) system are a direct result of the underlying inter-processor communications architecture. A new architecture for M&C at the Deep Space Communications Complexes (DSCCs) has been developed based on the Manufacturing Message Specification (MMS) process control standard that is part of the Open System Interconnection (OSI) suite of protocols. This architecture has been tested both in a laboratory environment and under operational conditions at the Deep Space Network (DSN) experimental station (DSS-13)...

Stockett, Michael H.↗

DSS-13: Using an OSI Process Control Standard for Monitor and Control

The flexibility and robustness of a monitor and control (M&C) system are a direct result of the underlying inter-processor communications architecture. A new architecture for M&C at the Deep Space Communications Complexes (DSCCs) has been developed based on the Manufacturing Message Specification (MMS) process control standard of the Open System Interconnection (OSI) suite of protocols. This architecture has been tested both in a laboratory environment and under operational conditions at the Deep Space Network (DSN) experimental station (DSS-13). The DSS-13 experience in the application of OSI standards to support M&C has been extremely successful. MMS meets the functional needs of the station and provides a level of flexibility and responsiveness previously unknown in that environment.

Stockett, Michael H.↗