Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Trigger-DAQ and Slow Controls Systems in the Mu2e Experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far. Mu2e's Trigger and Data Acquisition System (TDAQ) uses otsdaq as its solution. Developed at Fermilab, otsdaq uses the artdaq DAQ framework and art analysis framework, under the-hood, for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability, while providing a multi-user, web-based, interface accessible through the Chrome or Firefox web browser. The detector Read Out Controller (ROC), from the tracker and calorimeter, stream out zero-suppressed data continuously to the Data Transfer Controller (DTC). Data is then read over the PCIe bus to a software filter algorithm that selects events which are finally combined with the data flux that comes froma Cosmic Ray Ve to System (CRV). A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) Open Source Platform. The DCS System has also been itegrated into otsdaq. The installation of the TDAQ and the DCS systems in the Mu2e building is planned for 2021-2022, and a prototype has been built at Fermilab's Feynman Computing Center. We report here on the developments and achievements of the integration of Mu2e's DCS system into the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utah FORGE: Phase 1a Tensor Strainmeter Data for the April, 2022 Stimulation of Well 16A(78)-32

Data from two Tensor Optical Fiber Strainmeters that were operational during Stages 1, 2, and 3 of the April, 2022 stimulation of well 16A(78)-32. Each csv file contains data from each stimulation stage (stage1, stage2, stage3) for both Phase 1a strainmeter installations (FS01, formerly FS-C, and FS02, formerly FS1-2) in human-readable comma-separated value text files. There are two header lines in each file describing the data contained in that column along with their units, respectively. Data have been decimated from 2 to 1 Hz to match the Pason data found in the linked GDR dataset below (16A78-32 Stimulation Pason Data). These files contain the time series spanning the same time interval as the Pason data as well as ambient data for 5 hours before the stimulation and 5 hours following shut in. The station locations were chosen based on their proximity to the borehole seismometers owned and operated by the University of Utah. See README.txt for more information.

15 GEOTHERMAL ENERGY↗

Expanding the Solar Workforce through the Illinois Community College System

The Illinois Green Economy Network (IGEN) is a consortium of all 39 Illinois community college districts working to grow the green economy in the state. The network aims to build capacity in sustainability and transform education by connecting business/industry and educators to resources, curating information and tools, cultivating partnerships, and advocating for change. Led by IGEN, the goal of the “Expanding the Solar Workforce through the Illinois Community College System” project was to create and sustain a comprehensive, statewide strategy that equips education and training providers, workers, businesses, and communities with resources and tools to prepare a solar workforce. A cohort of five Illinois community colleges participated in the program based on their capacity and interest, as well as their potential for and proximity to industry growth in the state: City Colleges of Chicago, John A. Logan College, Kankakee Community College, Lewis and Clark Community College, and Lincoln Land Community College. The project had three Objectives, 1) Address an unmet need by increasing the pool of skilled solar workers, 2) Keep pace with evolving needs of the solar workforce by improving programs to be more accessible and industry-driven, 3) Strengthen IGEN’s capacity as a statewide resource for solar education, training, and workforce initiatives. Overall, over 400 students were trained in solar installation practices, with over 40 businesses engaged. Additionally. the project spurred a number of innovations and the development of effective practices related to establishing and maintaining a solar installation program at a community college. This project sought to identify effective and scalable practices for developing a solar installation program which included the following components: enrolling students into aligned programs; developing curriculum and courses which meet industry needs; placing students in solar installation or related employment; and sustaining programming past grant funding. Through this project- IGEN was able to identify critical components of a solar installation program. Detailed further in this report these components describe 1) Necessary conditions for establishing a solar installation program, 2) Program structures use cases for different contexts, 3) Effective practices related to student pipeline development and program throughout. As a result of this project- all five participating community colleges have expressed support for continuing to offer solar installation training to their students. Additionally, three nonparticipating colleges in IGEN have expressed interest in adopting practice, courses, or curriculum developed through this program. IGEN has also committed to making the curriculum, course structure and other materials available on their website for accelerated adoption of effective practices both state and nationwide.

14 SOLAR ENERGY↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

S AP F LOWER : an automated tool for sap flow data preprocessing, gap-filling, and analysis using deep learning

Sap flow, a critical process in plant water use and ecosystem water cycles, is often measured using thermal dissipation probes (TDP) due to their ease of installation and continuous data collection. However, sap flow data frequently include noise, outliers, and gaps, creating challenges for analysis and requiring substantial manual processing. We developed S AP F LOWER , a tool that automates data preprocessing, model training, gap-filling, sapwood area scaling and modeling, and water use analysis. It integrates autocleaning, machine learning and deep learning models (e.g. random forest, Gaussian process regression, long short-term memory (LSTM), bidirectional LSTM (BiLSTM)), and efficient workflows to process sap flow data. S AP F LOWER can remove over 90% of noisy data while preserving legitimate variations and achieve high accuracy in gap-filling based on user-determined parameters. Random forest, LSTM, and BiLSTM models reduced root mean square error to 10% or less for long-term gaps. Model training and prediction can be performed efficiently within seconds. S AP F LOWER significantly enhances the efficiency and accessibility of TDP data analysis by automating complex tasks, enabling researchers without programming expertise to employ advanced techniques. Future improvements will focus on species-specific corrections for TDP and support for additional measurement methods. S AP F LOWER is openly available on GitHub (https://github.com/JiaxinWang123/SapFlower) and Zenodo (doi: 10.5281/zenodo.13665919).

ecosystem water balance↗

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]↗

Mechanistic modeling of CO 2 well leakage in a generic abandoned well through a bridge plug cement-casing gap

Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.

58 GEOSCIENCES↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

City-Wide Distributed Roof-Top Photovoltaic System Adoption Forecast, Grid Impact Simulation, & Neighborhood Microgrid Contribution Assessment

The adoption of distributed photovoltaic (PV) systems grew significantly in recent years. Market projections anticipate future growth for both residential and commercial installations. To understand grid impacts associated with distributed PV, useful hosting capacity studies require accurate representations of the spatial distribution of PV adoptions. Prediction of PV locations and numbers depends on median income data, building use zoning maps, and permit records to understand existing trends and predict future adoption rates and locations throughout an entire city. Using the PV adoption data, advanced and realistic simulations were performed to capture the distributed PV impacts on the grid. Also, using graph theory community detection hundreds of neighborhood microgrids can be discovered for the entire city by identifying densely connected loads that are sparsely connected to other communities. Then, based on the PV adoption predictions, this work identified the contribution of PV within each of the newly discovered graph theory defined microgrid communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable Energy Landscapes: Designing Place-Based Infrastructure for Scale

This paper offers a pathway for developing community-centered renewable energy at scale, outlining how renewable energy landscapes can be envisioned alongside the high environmental and social equity standard that is at the heart of the future clean energy system. We call this “place-based at scale” and “renewable energy landscapes” because the ultimate aim is to adapt technology and infrastructure coherently and collectively toward community objectives, and to organize it to allow replicability and scaled approaches across the country. Realizing this type of development in practice will require reconciling the challenges and tensions that currently existing between top-down and bottom-up approaches. It will also require reckoning with greenhouse gas emission goals, large investments in infrastructure, and community self-determination as the driving priority in those investments. We believe a window of opportunity is presenting itself to shape and envision the future of renewable energy installations and move into action to create them. Six pathways that draw upon new cooperation between disciplines for designing renewable energy landscapes at scale are presented and historical perspectives are explored.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding and modeling current and future coastal wetland methane dynamics (Final Report)

The coastal terrestrial-aquatic interface (TAI) is a highly dynamic component of the Earth system that plays a critical role in biogeochemical cycling. Due to its dynamic nature, the processes that regulate decomposition and methane (CH 4 ) emissions are of greater significance at the TAI than in upland systems. Despite this, we have limited mechanistic understanding of how climate stressors interact to regulate the electron acceptors and donors that determine decomposition pathways within TAIs, including the generation of hot spots and hot moments. Accurately modeling these processes is critical for incorporating the coastal TAI into Earth systems models, such as DOE’s E3SM. With previous DOE support, we adapted an aerobic terrestrial representation of decomposition using PFLOTRAN, a reactive flow and transport model, and added anerobic decomposition pathways, salinity, and oxygen (O 2 ) that fluctuates independently of water table level. However, because this model (PFLOTRAN TAI ) is based on decomposition rates and organic matter carbon to nitrogen ratios from terrestrial systems, its performance in TAI systems is currently limited by the lack of empirical data to properly parameterize variables. In addition, while PFLOTRAN TAI can simulate movement of O 2 into sediments, it is not currently capable of tracking the movement of CH 4 gas through plant tissues due to both current model structure and lack of available data. Our overall objective of the project was the increase our mechanistic understanding of CH 4 dynamics in response to environmental change, such that we can improve the representation of these dynamics in PFLOTRAN. We installed automated flux chambers in a new field-scale active soil warming experiment and set up marsh organs (mesocosms) to test effects of warming, flooding, and salinity. This resulted in a new dataset consisting of chamber-level CH 4 flux measurements across multiple sites, ecological conditions, and timeframes, as well as corresponding measurements on porewater chemistry, soil carbon quality, plant biomass, and redox reaction rates. Using these data, we improved PFLOTRAN TAI to more accurately model CH 4 dynamics and successfully tested our hypotheses. This grant contributed to the professional development of 3 postdocs, 4 undergraduate interns, 4 teacher interns, 17 technicians, and 15 participatory scientists. The automated chamber technology designed for this grant has also been shared with multiple new projects.

54 ENVIRONMENTAL SCIENCES↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Regional Representation of Wind Stakeholders' End-of-Life Behaviors and Their Impact on Wind Blade Circularity

Wind plant power has seen tremendous growth in the US and worldwide, representing the most significant renewable energy installed capacity besides hydropower. While wind power enables decarbonizing the electricity grid, the rising amount of end-of-life (EOL) wind blades - which are arduous to recycle - present a challenge for landfills if disposed of whole and a missed opportunity to recover valuable composite materials. The circular economy (CE) concept proposes strategies to rethink, reuse and recover products, components, and materials. However, transitioning to a CE implies changing how business models, supply chains, and behaviors deal with products and waste; changes arduously captured with traditional methods used to assess circularity such as life cycle assessment or material flow analysis (MFA). Here we present an agent-based model (ABM) that captures behavioral aspects impacting wind blade circularity in the US. The ABM also accounts for wind plant projects and landfills heterogeneity - a characteristic not easily included in top-down approaches such as MFA, input-output analysis, or system dynamics. Results show that recycling is divided as most recycling facilities are on the eastern side of the country, a challenge that could be alleviated by shredding blades before transportation. Recycling programs from the wind industry could also seed recycling behaviors within wind plant owners. Better yet, new blade designs could increase circularity if original equipment manufacturers accept the risks involved with the investments needed to adapt the production lines.

17 WIND ENERGY↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Characterization of core neutrals using passive measurements of the D α spectrum near the X -point in the DIII-D tokamak

New spectroscopic measurements of deuterium Balmer-α emission are used to infer the spatial distribution of neutral particles near the X-point in a diverted high confinement mode plasma. The charge exchange neutral spectroscopy (CENS) diagnostic—recently installed on the DIII-D tokamak—uses 15 lines of sight extending from the edge of the confined region (ρ ≈ 0.7) to the X-point in lower single-null plasmas. Each CENS line of sight is spectrally resolved around the deuterium Balmer-α wavelength (6561 Å) to measure the Doppler shift, line broadening, and intensity of Dα emission. Thermal line broadening is used to identify emission from neutrals undergoing charge-exchange (CX) with high temperature ions in the confined plasma. This spectral information allows a more accurate determination of the neutral density deeper inside the confined plasma compared to traditional filter-based diagnostics. We present two methods of analyzing CENS measurements: (1) fitting the spectrum from each view-chord separately, and (2) a tomographic method for inverting the neutral density over a 2D region of space using all CENS views collectively. The neutral density profile is found to decay exponentially in the radial direction with two scale-lengths. In the pedestal region the neutral density decays at a rate approximately equal to the local mean-free-path for CX collisions, $L_{n_\mathrm{D0}}\approx \lambda_\text{CX}$. Further inside the plasma the neutral density decays at a rate equal to the mean-free-path for ionization, $L_{n_\mathrm{D0}}\approx \lambda_\text{inz.}$. The separatrix $n_\mathrm{D0}$ value is found to be approximately $2\times10^{15}$ m−3. Based on results from the 2D inversion, the density of neutrals is found to increase along the separatrix approaching the X-point by a factor of $\approx 5\times$ over the region covered by the CENS diagnostic.

X-point neutrals↗

Aluminum Electrolytic Capacitor Vulnerability Evaluation in DC Power Supplies at the Spallation Neutron Source

The service life of electrolytic capacitors is a concern for long-term reliable operation of power supplies. The Power Conversion Group at the Spallation Neutron Source (SNS) facility of Oak Ridge National Laboratory is responsible for more than 500 power supplies with over 1000 electrolytic capacitors installed in these power supplies. Most of the electrolytic capacitors have been in operation since 2007 and are either well over or close to the manufacturer provided lifetime. This paper addresses this vulnerability to ensure continued reliable operation of the SNS. The power supply circuit is simulated in a MATLAB/Simulink environment to quantify the capacitor ripple current and operating voltage. Combined with manufacturer data, this information is used to estimate capacitor lifetime. Utilizing the simulation results and lifetime projections of the capacitors, capacitor replacements for the power supplies is prioritized. To assess end-of-life, the ambient temperature and ripple current of the capacitor is used. Based on the manufacturer's data and scientific literature review, capacitor end-of-life is established. The results of the simulations and analysis is presented. Data on the highest priority supplies will also be presented, and statistics on the capacitor performance, reliability and remaining lifetime will be shown.

Harave, Sudarshan↗