Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Photometric imaging of Mars during the 1973 opposition

The paper discusses imaging of Mars at 20 wavelengths in the spectral region from 0.35 to 1.10 microns performed during the 1973 opposition with a photometric imaging system that uses a silicon vidicon tube as the detector. The imaging system and data-reduction procedures are described in detail, and relative reflectance spectra for several small areas in the images are presented along with vidicon images obtained during early phases in the development of the 1973 dust storms. Several anomalous blue brightenings are examined and attributed to ground fog and H2O frost. It is suggested that anomalously large amounts of H2O were pulsed into the atmosphere from the regolith by the storm system. An apparent fading and recession of the north polar hood is noted, surface units revealed in contrast-enhanced ratio images are identified, and the need for higher-spatial-resolution orbital spectroscopy of dark areas is emphasized.

Mccord, T. B.↗

An ultrasonic scanning system for arterial imaging

A transcutaneous system for real-time imaging of arteries is described. A transducer probe containing three linear arrays of elements scans tissues within the element Fresnel zones. Each element is multiplexed in turn to a pulsed Doppler processor to permit real-time visualizations of moving targets. Applications of the motion-indicating B-scans are discussed, with special attention to problems in transcutaneous measurement of blood flow.

Hottinger, C. F.↗

The evolution of the spaceborne imaging radar system toward Eos

Progress to date and intended goals in the development of the Spaceborne Imaging Radar (SIR), a SAR remote sensing instrument targeted for carriage on one of the three polar orbiting earth observation system (EOS) platforms in the 1990s, are described. The Shuttle is the current testbed for the SIR, with spaceborne trials being used for testing continually upgraded versions of the three major components of the SIR: the electronics, the antenna and the digital data system. Experimentation is being performed in X-, K-, C- and P-bands in terms of the SNR, view angle, resolution and specific terrestrial features. The test flights are also serving to identify the most effective orbits, with consideration given to the capabilities of other instrumentation being developed for the EOS.

Cimino, J.↗

The integration of remote sensing data into global weather prediction, wave forecasting, and ocean circulation computer based systems

Data from infrared imaging systems and satellite infrared spectrometer (SIRS) for determining sea surface temperature and the atmospheric structure in cloudless areas over the oceans are discussed. Although some interpretations differ, it is clear that simultaneous measurements of radar sea return and passive microwave temperature will provide estimates of the wind speed, and perhaps wind direction, over the oceans, especially in cloudless areas, for a wide range of wind speeds. The problem of integrating the data that would be obtained by a spacecraft, especially one with a combination radar-radiometer, into global analysis procedures for meteorological, wave, and oceanographic predictions is described.

Pierson, W. J., Jr.↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A unified approach to the classification of visual data systems.

Description of an approach to attaining a unified means of characterizing film, TV, and optical data systems. The concept is based on the premise that all of these imaging systems can be described by an equation similar to the ideal imaging system described by Rose (1948). This technique permits the direct comparison of film and TV performance without converting speed, film resolution lines, TV resolution lines, highlight output current and video bandwidth into compatible units, only to find some essential element of the conversion has been omitted from the particular specification in use. Most important, it permits system performance criteria to be based on input and output criteria without extensive manipulation of the elements between input and output.

Black, J.↗

Optical alignment device

A patent application was presented for an invention whose principal objective is the provision of an improved alignment device for observing the degree of coalignment of a pair of objects. The device includes a beamsplitter to be interposed between a pair of objects for observing the degree of coalignment. Light from one of the objects is reflected from the beamsplitter into a retroreflector which reflects the light back through the beamsplitter into an imaging system. Light from the other object is reflected from the beamsplitter into the same imaging system. The amount of displacement of the two images is inversely related to the degree of coalignment of the two objects. The optical alignment device is useful for aligning a mirror with an object, two objects or two mirrors.

Thomas, N. L.↗

A database system to support image algorithm evaluation

The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.

Lien, Y. E.↗

Model development for flash boiling spray and validations with isooctane, hexane, ethanol and their binary mixtures

The objective of this study is to develop a comprehensive model for spray atomization under the consideration of flash boiling, which includes nucleation, bubble growth, and droplet breakup. Although flash boiling has been previously studied, there is still no well-established analytical and numerical model of their mechanisms, or general guidelines on the implementation of this atomization strategy. In this study, detailed formulations are elaborated for the unified spray atomization model under both non-flash and flash boiling conditions. Next, the model was implemented into CFD software and 3-D simulations were performed for model validations. Two fuel blends are tested: ethanol-isooctane blends and hexane-isooctane blends. Simulation results were compared with the experimental measurements conducted using two methodologies, DBI (Diffuse Backlight Imaging) system for spray images captured by a high-speed camera, and a PDA (Phase Doppler Anemometry) system for droplet size measurement during the spray injection process. It was found that the current flash boiling model can accurately capture the spray characteristics under different environment conditions, such as the spray plume interactions and liquid penetration. The averaged Sauter mean diameter (SMD) calculations match the measurement sufficiently well. The spray structures for both single- and multi-component fuels during the injection process are well represented by current model.

42 ENGINEERING↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗

A positron projection imager for whole-body mouse imaging

Certain experimental questions in molecular imaging can be answered with projection imaging systems rather than tomographs. Accordingly, we have designed, assembled and are now testing a projection imaging system able to visualize the whole-body distribution of positron-emitting compounds in mouse-size animals. When completed, this positron projection imager (PPI) will plug into the MONICA portable dual gamma camera system to provide the user with a positron projection imaging capability and all of the data acquisition and analysis features available with MONICA for single photon projection imaging.

Seidel, J.↗

Development of a mini-PET Detector based on Silicon Photomultiplier Arrays for Plant Imaging Applications

Certain experimental questions in molecular imaging can be answered with projection imaging systems rather than tomographs. Accordingly, we have designed, assembled and are now testing a projection imaging system able to visualize the whole-body distribution of positron-emitting compounds in mouse-size animals. When completed, this positron projection imager (PPI) will plug into the MONICA portable dual gamma camera system to provide the user with a positron projection imaging capability and all of the data acquisition and analysis features available with MONICA for single photon projection imaging.

Zorn, Carl↗

Parameter trade-offs for imaging spectroscopy systems

With the advent of the EOS era and of configurable sensors, users of these instruments are faced with the twin problems of specifying data acquisition parameters and extracting desired information from the voluminous data. An application of a system model is made to explore system parameter trade-offs for a model sensor based on the High Resolution Imaging Spectrometer. Radiometric performance was studied, along with the effect on classification accuracy of several system parameters. Using a model scene based on typical agricultural reflectance and atmospheric conditions, the atmosphere and sensor are seen to have significant effects on the mean received signal and noise performance. The effect of random uncorrelated errors in the radiometric calibration of the detector array is seen to degrade system performance, especially in the spectral bands below 1 micron. Accurate pixel-to-pixel relative radiometric calibration and the use of the Image Motion Compensation option are seen to improve classification accuracy, especially at high solar zenith angles. Feature sets chosen from characteristics of the scene performed best overall, but ones chosen based on signal-to-noise ratios were seen to be more robust.

Kerekes, John P.↗

STS-85 Day 09 Highlights

On this ninth day of the STS-85 mission, the flight crew, Cmdr. Curtis L. Brown, Jr., Pilot Kent V. Rominger, Payload Cmdr. N. Jan Davis (Ph.D.), Mission Specialists Robert L. Curbeam, Jr. and Stephen K. Robinson (Ph.D.), and Payload Specialist Bjarni V. Tryggvason watch over the Manipulator Flight Demonstration (MFD) experiment while Japanese investigators again maneuvere the Small Fine Arm remotely from a control room near Mission Control. It is the final planned work with the arm during this mission. While MFD operations are ongoing, Robinson again uses the Southwest Ultraviolet Imaging System's ultraviolet imaging telescope to observe Comet Hale-Bopp and Curbeam continue his work with the Bioreactor Demonstration System designed to perform cell biology experiments under controlled conditions. Tryggvason spends his day supporting data gathering with the Microgravity Vibration Isolation Mount experiment. Before the crew's workday began, they discussed the mission's progress with reporters in the U.S. and Canada as part of the traditional crew news conference. Questions ranged from life in space for the first time space travelers to providing a report card on the more than 24 experiments being conducted throughout the mission.

Source record↗

Self characterization of a coded aperture array for neutron source imaging

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-29: Generalized Relative Object Detectability (G-ROD): A Metric for Comparing X-Ray Imaging Detector Systems

Purpose: To determine the relative task-specific performance of two x-ray imaging detectors including the effect of other components of the imaging chain. Methods: The relative object detectability (ROD) was defined as the ratio of the integral of the detective-quantum efficiency (DQE) of a detector weighted by the square of the Fourier Transform (or frequency spectrum) of the object to the same integral for a second detector. The generalized ROD (G-ROD) is calculated by replacing DQE by the generalized DQE (GDQE) which includes geometric unsharpness and scatter to evaluate the total imaging chain. The G-ROD was calculated for the micro-angiographic fluoroscope (MAF) relative to a flat-panel detector (FPD) for low (1.05) and high (1.2) magnifications with two focal-spot sizes, small (0.3 mm) and medium (0.5 mm), and for the same value of scatter fraction. Solid spheres from 50 to 600 microns were simulated as the objects for this evaluation. The G-ROD results were compared with those of the ROD which considers the detectors alone. Results: For 50-micron spheres, the ROD is 7.93 and, for the small [medium] focus, the G-ROD is 6.74 [5.22] at low magnification and 3.03 [1.66] at high magnification, indicating superior performance of the MAF particularly at low magnification. Both ROD and G-ROD decrease monotonically with size and remain around one above 400-microns. The G-ROD decreases more dramatically with low compared to high magnification for both focal spots. Conclusion: In all cases, the MAF performs better than the FPD and the decreasing trend of the G-ROD indicates that the performance of both detectors becomes similar as the object size increases and becomes nearly equal above 400-micron diameter sphere size. Finally, increased magnification and focal-spot size decrease the G-ROD, indicting that they degrade the performance of the MAF more than that of the FPD for a small-object viewing task. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

60 APPLIED LIFE SCIENCES↗