Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Spectroscopic photoelectric imaging Fabry-Perot interferometer - Its development and preliminary observational results

In order to observe extended astronomical objects at high spatial and spectral resolution, we have constructed a spectroscopic photoelectric imaging Fabry-Perot interferometer (SPIFI). Among the properties chosen for the instrument are an air-spaced, piezoelectrically scanned design allowing an accurately settable free spectral range and employing a single etalon of high finesse. Careful design of the etalon mountings and optical train preserves high light throughput. We either obtain spectra of single spatial elements with a photomultiplier or use an SEC vidicon detector to record a series of images through the interferometer while scanning the wavelength in discrete steps. The latter procedure yields sufficient information to reconstruct spectral features over the entire object. For the conditions assumed, either series of observations requires only a small fraction of a rotational period for Jupiter or Saturn, for example.

Smith, W. H.↗

Bevalac calibration of the SOFIE range and hodoscope detectors

The scintillating optical fiber isotope experiment (SOFIE) is a Cerenkov-dE/dx-Range experiment which was developed initially for balloon flight to study the isotopic composition of cosmic rays in the iron region. The electronic range and hodoscope detectors use scintillating optical fibers to image the tracks of stopping charged particles and to determine their trajectory. The particle range is determined and used together with a Cerenkov measurement to determine the mass of the stopping particle. Preliminary results of a Bevalac calibration performed in August, 1984 with a prototype of the balloon flight instrument, to study the measurement precision in range and trajectory which could be attained with this detector are described.

Binns, W. R.↗

Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images

Characterization was conducted under the Memorandum of Understanding among Orbital Sciences Corp., ORBIMAGE, Inc., and NASA Applied Sciences Directorate. Acquired five OrbView-3 panchromatic images of the permanent Stennis Space Center edge targets painted on a concrete surface. Each image is available at two processing levels: Georaw and Basic. Georaw is an intermediate image in which individual pixels are aligned by a nominal shift in the along-scan direction to adjust for the staggered layout of the panchromatic detectors along the focal plane array. Georaw images are engineering data and are not delivered to customers. The Basic product includes a cubic interpolation to align the pixels better along the focal plane and to correct for sensor artifacts, such as smile and attitude smoothing. This product retains satellite geometry - no rectification is performed. Processing of the characterized images did not include image sharpening, which is applied by default to OrbView-3 image products delivered by ORBIMAGE to customers. Edge responses were extracted from images of tilted edges in two directions: along-scan and cross-scan. Each edge response was approximated with a superposition of three sigmoidal functions through a nonlinear least-squares curve-fitting. Line Spread Functions (LSF) were derived by differentiation of the analytical approximation. Modulation Transfer Functions (MTF) were obtained after applying the discrete Fourier transform to the LSF.

Blonski, Slawomir↗

Model-Based Reconstruction for Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a novel technology for imaging inside multi-layered structures such as geothermal wells. Such systems include a transmitter and multiple receivers to capture reflected signals. Common algorithms for ultrasound reconstruction use delay-and-sum (DAS) approaches; these have low computational complexity but produce inaccurate images in the presence of complex structures and specialized geometries such as collimated beams.In this paper, we propose a multi-layer, ultrasonic, model-based iterative reconstruction algorithm designed for collimated beam systems. We introduce a physics-based forward model to accurately ac-count for the propagation of a collimated ultrasonic beam in multi-layer media and describe an efficient implementation using binary search. We model direct arrival signals, detector noise, and a spatially varying image prior, then cast the reconstruction as a maximum a posteriori estimation problem. Using simulated and experimental data we obtain significantly fewer artifacts relative to DAS while running in near real time using commodity compute resources.

Alanazi, Abdulrahman M.↗

Machine Learning for DUNE Supernova Trigger

One of the major scientific goals of the Deep Underground Neutrino Experiment (DUNE) is to detect and measure the neutrino flux from galactic core-collapse supernovae. These neutrinos, which exist in the low energy range of up to a few tens of MeV and are responsible for carrying away over 99% of the gravitational binding energy of the supernova, provide an opportunity to study the end of life evolution of massive stars, as well as unique properties and interactions of neutrinos. Because galactic supernovae are expected to occur only on the timespan of every few decades, it is crucial that DUNE is able to detect supernova neutrino interactions when they occur. However, detecting these supernova interactions requires sifting through a large amount of data, and DUNE detectors require a trigger to signal when supernova neutrino events occur. Machine learning provides a potential approach to creating this trigger. This project generates ADC and ground truth images of neutrino interactions in a LArTPC detector as simulated by the Model of Argon Reaction Low Energy Yields (MARLEY) to be used for machine learning. The eventual goal of this work is to facilitate DUNE s detection of supernova neutrino interactions by building a machine learning pipeline that will train the trigger algorithm.

Damish, Stephanie↗

Machine Learning for DUNE Supernova Trigger

One of the major scientific goals of the Deep Underground Neutrino Experiment (DUNE) is to detect and measure the neutrino flux from galactic core-collapse supernovae. These neutrinos, which exist in the low energy range of up to a few tens of MeV and are responsible for carrying away over 99% of the gravitational binding energy of the supernova, provide an opportunity to study the end of life evolution of massive stars, as well as unique properties and interactions of neutrinos. Because galactic supernovae are expected to occur only on the timespan of every few decades, it is crucial that DUNE is able to detect supernova neutrino interactions when they occur. However, detecting these supernova interactions requires sifting through a large amount of data, and DUNE detectors require a trigger to signal when supernova neutrino events occur. Machine learning provides a potential approach to creating this trigger. This project generates ADC and ground truth images of neutrino interactions in a LArTPC detector as simulated by the Model of Argon Reaction Low Energy Yields (MARLEY) to be used for machine learning. The eventual goal of this work is to facilitate DUNE s detection of supernova neutrino interactions by building a machine learning pipeline to train the trigger algorithm.

Damish, Stephanie↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Far-ultraviolet MAMA detector imagery and emission-line CCD imagery of NGC 6240

An image of the luminous infrared galaxy NGC 6240 at 1480 A was obtained using a multianode microchannel array (MAMA) detector with a rocket-borne telescope. At distances greater than 12 arcsec from the nucleus, the measured ultraviolet luminosity implies intensive star formation activity equal to 2-3 times that of a spiral galaxy such as M83. Optical images in the H-beta and forbidden O III 5007 A emission lines reveal a region of high excitation east of the nucleus between the centers of disks 1 and 2 as described by Bland-Hawthorn et al.

Smith, Andrew M.↗

Detector for Particle Surface Contamination

A system and method for detecting and quantizing particle fallout contamination particles which are collected on a transparent disk or other surface employs an optical detector, such as a CCD camera, to obtain images of the disk and a computer for analyzing the images. From the images, the computer detects, counts and sizes particles collected on the disk The computer also determines, through comparison to previously analyzed images, the particle fallout rate, and generates an alarm or other indication if the rate exceeds a maximum allowable value. The detector and disk are disposed in a housing having an aperture formed therein for defining the area on the surface of the disk which is exposed to the particle fallout. A light source is provided for evenly illuminating the disk. A first drive motor slowly rotates the disk to increase the amount of its surface area which is exposed through the aperture to the particle fallout. A second motor is also provided for incrementally scanning the disk in a radial direction back and forth over the camera so that the camera eventually obtains images of the entire surface of the disk which is exposed to the particle fallout.

Mogan, Paul A.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

Ring artifact and Poisson noise attenuation via volumetric multiscale nonlocal collaborative filtering of spatially correlated noise

X-ray micro-tomography systems often suffer from high levels of noise. In particular, severe ring artifacts are common in reconstructed images, caused by defects in the detector, calibration errors, and fluctuations producing streak noise in the raw sinogram data. Furthermore, the projections commonly contain high levels of Poissonian noise arising from the photon-counting detector. This work presents a 3-D multiscale framework for streak attenuation through a purposely designed collaborative filtering of correlated noise in volumetric data. A distinct multiscale denoising step for attenuation of the Poissonian noise is further proposed. By utilizing the volumetric structure of the projection data, the proposed fully automatic procedure offers improved feature preservation compared with 2-D denoising and avoids artifacts which arise from individual filtering of sinograms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

X-Ray Detector for 1 to 30 keV

Array of silicon X-ray detecting diodes measures photon energy and provides image of X-ray pattern. Regardless of thickness of new X-ray detector, depletion region extends through it. Impinging X-rays generate electrons in quantities proportional to X-ray energy. X-ray detector is mated to chargecoupled-device array for image generation and processing. Useful in industrial part inspection, pulsed-plasma research and medical application.

Alcorn, G.↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Diffraction-limited 10 microns imaging with 3 meter telescopes

An IR imaging system that achieves diffraction-limited spatial resolution (about 0.8 arcsec) at 10 microns on 3-meter ground-based telescopes. The system uses a linear array of sensitive HgCdTe photodiodes, scanned in the direction perpendicular to the array axis, to form two-dimensional images. Scans are completed rapidly enough to freeze atmospheric fluctuations. Individual detectors are small compared to the diameter of the Airy disk, and images are oversampled heavily in the scan direction. This method has a number of advantages for studying small fields with very high spatial resolution, and has been applied successfully to the problem of directly imaging faint circumstellar dust shells.

Bloemhof, E. E.↗

SIRTF - Capabilities for planetary science

Major research areas of the Space Infrared Telescope Facility (SIRTF) are discussed which include Kuiper-belt comets, IR spectroscopy of comets, and circumstellar planetary debris disks. SIRTF instrumentation will include the infrared array camera (IRAC) and multiband imaging photometer (MIP). The IRAC uses large area, 2D infrared array detectors to provide wide-field (7 arcmin) and diffraction-limited imaging over the spectral region from 2 to 30 microns. The MIP will provide background-limited imaging and photometry over the wavelength range from 30 to 200 microns, wide-field, high resolution imaging from 50 to 120 microns, and broad band photometry and mapping from 200 to 700 microns.

Cruikshank, D. P.↗

Multi-Particle Three-Dimensional Covariance Imaging: “Coincidence” Insights into the Many-Body Fragmentation of Strong-Field Ionized D 2 O

We demonstrate the applicability of covariance analysis to three-dimensional velocity-map imaging experiments using a fast timestamping detector. Studying the photofragmentation of strong-field doubly ionized D$_2$O molecules, we show that combining high count rate measurements with covariance analysis yields the same level of information typically limited to the `gold standard' of true, low count rate coincidence experiments, when averaging over a large ensemble of photofragmentation events. This increases the effective data acquisition rate by approximately two orders of magnitude, enabling a new class of experimental studies. This is illustrated through an investigation into the dependence of three-body D$_2$O$^{2+}$ dissociation on the intensity of the ionizing laser, revealing mechanistic insights into the nuclear dynamics driven during the laser pulse. Here, the experimental methodology laid out, with its drastic reduction in acquisition time, is expected to be of great benefit to future photofragment imaging studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of High-Performance Detector Technology for UV and IR Applications

Sensing and imaging for ultraviolet (UV) and infrared (IR) bands has many applications for NASA, defense, and commercial systems. Recent work has involved developing UV avalanche photodiode (UVAPD) arrays with high gain for high resolution imaging. Various GaN/AlGaN p-i-n UV-APDs have been fabricated from epitaxial structures grown by metalorganic chemical vapor deposition (MOCVD) on GaN substrates with avalanche gains greater than 5×105, and high responsivities. Similarly, the IR spectral band is useful for measuring ocean temperatures, atmospheric aerosols, forest fires, etc. We are also developing room temperature operating graphene-enhanced PbSe midwave infrared (MWIR) detectors and focal plane arrays (FPAs). These compact and low-cost MWIR sensors can benefit various NASA remote sensing applications. Here we present recent results from these high performance UV- and IR-band detector and FPA technologies.

Sood, Ashok K.↗