Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

The All Sky Monitor for the X-ray Timing Explorer

The All Sky Monitor (ASM) for the X-ray Timing Explorer (XTE), whose purpose is to record a photometric history of known objects and to detect and locate transient objects, is discussed. This instrument uses the multiple pinhole approach to avoid photon starvation for good photometric capability together with good angular resolution and an excellent capability for locating transients. While the XTE ASM does not have the ideal imaging qualities of the uniformly redundant array-based designs, it is simpler to build and requires a modest telemetry bandwidth; since the ASM is intended for detection, location, and photometry of discrete point sources, imaging is of secondary importance.

Doty, John P.↗

Studies of optical and biological properties of terrestrial land cover using multispectral linear array technology

A series of experiments to study the optical and biological properties of terrestrial land cover are planned for late 1987 using a six-channel imaging spectroradiometer based on newly developed multispectral linear array (MLA) detector technology. Data from selected portions of the Sahel and rain forests of Africa and South America will be used to delineate biomass classes and estimate spherical albedos. A spatial resolution of 15 meters in the four visible-near IR channels and 30 meters in two shortwave IR channels, including a 'new' channel centered at 1.24 micrometers when combined with a spectral width of 20 nm for all channels, will be used to investigate possible improvements in land cover classification. Technology demonstrations include a test of data compression on data quality, the first spaceborne utilization of short wave infrared Schottky barrier Pd2Si detector arrays, and the use of close-butted, multi-array modules with attached spectral filters.

Barnes, W. L.↗

Surface-Micromachined Planar Arrays of Thermopiles

Planar two-dimensional arrays of thermopiles intended for use as thermal-imaging detectors are to be fabricated by a process that includes surface micromachining. These thermopile arrays are designed to perform better than do prior two-dimensional thermopile arrays. The lower performance of prior two-dimensional thermopile arrays is attributed to the following causes: The thermopiles are made from low-performance thermoelectric materials. The devices contain dielectric supporting structures, the thermal conductances of which give rise to parasitic losses of heat from detectors to substrates. The bulk-micromachining processes sometimes used to remove substrate material under the pixels, making it difficult to incorporate low-noise readout electronic circuitry. The thermoelectric lines are on the same level as the infrared absorbers, thereby reducing fill factor. The improved pixel design of a thermopile array of the type under development is expected to afford enhanced performance by virtue of the following combination of features: Surface-micromachined detectors are thermally isolated through suspension above readout circuitry. The thermopiles are made of such high-performance thermoelectric materials as Bi-Te and Bi-Sb-Te alloys. Pixel structures are supported only by the thermoelectric materials: there are no supporting dielectric structures that could leak heat by conduction to the substrate.

Foote, Marc C.↗

Simulation of the photogrammetric appendage structural dynamics experiment

The Photogrammetric Appendage Structural Dynamics Experiment (PASDE) uses six video cameras in the Space Shuttle cargo bay to measure vibration of the Russian Mir space station Kvant-ll solar array. It occurs on Shuttle/Mir docking mission STS-74 scheduled for launch in November 1995. The objective of PASDE is to demonstrate photogrammetric technology for measuring 'untargeted' spacecraft appendage structural dynamics. This paper discusses a pre-flight simulation test conducted in July 1995, focusing on the image processing aspects. The flight camera system recorded vibrations of a full-scale structural test article having grids of white lines on black background, similar in appearance to the Mir solar array. Using image correlation analysis, line intersections on the structure are tracked in the video recordings to resolutions of less than 0.1 pixel. Calibration and merging of multiple camera views generated 3-dimensional displacements from which structural modal parameters are then obtained.

Pappa, Richard S.↗

Multi-element metasurface system for imaging in the near-infrared

Metasurfaces are optically thin 2D arrays of subwavelength scatterers that modify scalar and vector properties of incident electromagnetic fields. Metasurface lenses are of particular interest for imaging applications for their flat form factor, compatibility with CMOS fabrication processes, and potential for correcting aberrations with a small number of elements. Here, we advance this capability by realizing a millimeter-diameter, polarization-independent metalens triplet system with chromatic aberration correction over the wavelength range of 1.30–1.60 μm and monochromatic aberration correction enabling a field of view of 50°.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An adaptable technique for comparative image assessment: Application to crosswell electromagnetic survey design for fluid monitoring

Reservoir integrity stewardship accompanying carbon capture and sequestration considers fluid extraction and reinjection as a risk-mitigating method against overpressuring that could lead to caprock damage and ensuing [Formula: see text] leakage. Crosswell electromagnetics offers a technically viable monitoring method with the spatial volume coverage necessary for reservoir-encompassing pressure management. However, a certain logistic dilemma for deep gas sequestration into saline and thus electrically conductive aquifers is that crosswell magnetic-field measurements underperform in the imaging of more resistive plume bodies, further exacerbated when vertical arrays intersect, as opposed to surround, plumes. Furthermore, comparative synthetic-data plume imaging of such scenarios rates the information content of magnetic-field versus electric-field 3D crosswell layouts for reservoir and infrastructure conditions of a representative pilot site in a coastal area in Florida. The image quality of the resulting plume replications can be ranked numerically through a newly proposed semblance qualifier, appraising the model goodness of fit to a given reference. In contrast to common least-squares measures for goodness of fit, the semblance formulation uses classifying logistic function types, thus enabling a better distinction of predefined anomaly features.

58 GEOSCIENCES↗

Ge/Si Integrated Circuit For Infrared Imaging

Proposed integrated circuit consists of focal-plane array of metal/germanium Schottky-barrier photodetectors on same chip with silicon-based circuits that processes signals from photodetectors. Made compatible with underlying silicon-based circuitry by growing germanium epitaxially on silicon circuit wafers. Metal deposited in ultrahigh vacuum immediately after growth of germanium. Combination of described techniques results in high-resolution infrared-imaging circuits of superior performance.

Fathauer, Robert W.↗

Correlation Between Bulk Material Defects and Spectroscopic Response in Cadmium Zinc Telluride Detectors

One of the critical challenges for large area cadmium zinc telluride (CdZnTe) detector arrays is obtaining material capable of uniform imaging and spectroscopic response. Two complementary nondestructive techniques for characterizing bulk CdZnTe have been developed to identify material with a uniform response. The first technique, infrared transmission imaging, allows for rapid visualization of bulk defects. The second technique, x-ray spectral mapping, provides a map of the material spectroscopic response when it is configured as a planar detector. The two techniques have been used to develop a correlation between bulk defect type and detector performance. The correlation allows for the use of infrared imaging to rapidly develop wafer mining maps. The mining of material free of detrimental defects has the potential to dramatically increase the yield and quality of large area CdZnTe detector arrays.

Parker, Bradford H.↗

Coherent Detector Arrays for Continuum and Spectral Line Applications

This viewgraph presentation reviews the requirements for improved coherent detector arrays for use in continuum and spectral line applications. With detectors approaching fundamental limits, large arrays offer the only path to sensitivity improvement. Monolithic Microwave Integrated Circuit (MMIC) technology offers a straightforward path to massive focal plane millimeter wave arrays: The technology will readily support continuum imagers, polarimeters and spectral line receivers from 30-110 GHz. Science programs, particularly large field blind surveys will benefit from simultaneous observations of hundreds or thousands of pixels 1000 element array is competitive with a cost less than $2M.

instrumentation↗

Light field X-ray optics

Devices, systems and methods for performing X-ray scans with a single line of sight using a lens array for capturing the light field of the X-rays are described. In one example aspect, an X-ray optical system includes a primary optics subsection positioned to receive incoming X-rays after traversal through an object and to redirect the received incoming X-rays onto an intermediate image plane. The system also includes a microlens array positioned at or close to the intermediate image plane to receive at least some of the received incoming X-rays after redirection by the primary optics subsection to diffract the X-rays that are incident thereupon.

Kozioziemski, Bernard J.↗

Use of Very Long Baseline Array Interferometric Data for Spacecraft Navigation

The main VLBI technique that is used at JPL is known as the Delta Differential One-way Ranging ((Delta)DOR). Two DSN antennas simultaneously track a source, and alternate between sources. The signals recorded at the antennas from each source are correlated to obtain the delay in arrival to the two antennas, and the delays are differenced to remove common-source errors. An alternative technique is to use carrier phase differences between antennas. This is routinely done by the Very Large Baseline Array (VLBA) as part of source imaging. The VLBA capabilities are used for scientific research, but also have the potential to be used for navigation. Two main experiments were performed with the VLBA and JPL spacecraft. This paper describes and analyzes these experiments and discusses the possible uses of VLBA tracking for spacecraft navigation.

Very Large Baseline Array (VLBA)↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

COSMIC: A high resolution, large collecting area telescope

The spaceborne Coherent Optical System of Modular Imaging Collectors (COSMIC) is presented. It has high angular resolution and can produce images of complex, low-surface-brightness objects such as distant galaxies. If configured as a 36 m filled linear array, COSMIC can have 15 times better angular resolution and 10 times greater collecting area than the Space Telescope. Alternatively, if the collecting area is spread out to create an unfilled two-dimensional array, there is the additional advantage of not needing to rotate the array in order to build up a reconstructed image. Considerations which led to the design concept, scientific goals, and the potentially useful role of a space station for assembly are discussed.

Traub, W. A.↗

Low frequency propagation in the earth's magnetosphere

Using a model to simulate wave propagation, estimates were obtained on the effect of the earth's magnetosphere on the imaging potential of the Low-Frequency Space Array mission for observations above the ionosphere at frequencies below about 10 MHz. Results of this simulation show that, for imaging at 1.5 MHz, large orbital radii will be required. It is concluded that successful imaging from within the plasmasphere may depend upon the feasibility of correction schemes.

Dennison, Brian↗

Directivity of a Sparse Array in the Presence of Atmospheric-Induced Phase Fluctuations for Deep Space Communications

Widely distributed (sparse) ground-based arrays have been utilized for decades in the radio science community for imaging celestial objects, but have only recently become an option for deep space communications applications with the advent of the proposed Next Generation Deep Space Network (DSN) array. But whereas in astronomical imaging, observations (receive-mode only) are made on the order of minutes to hours and atmospheric-induced aberrations can be mostly corrected for in post-processing, communications applications require transmit capabilities and real-time corrections over time scales as short as fractions of a second. This presents an unavoidable problem with the use of sparse arrays for deep space communications at Ka-band which has yet to be successfully resolved, particularly for uplink arraying. In this paper, an analysis of the performance of a sparse antenna array, in terms of its directivity, is performed to derive a closed form solution to the expected array loss in the presence of atmospheric-induced phase fluctuations. The theoretical derivation for array directivity degradation is validated with interferometric measurements for a two-element array taken at Goldstone, California. With the validity of the model established, an arbitrary 27-element array geometry is defined at Goldstone, California, to ascertain its performance in the presence of phase fluctuations. It is concluded that a combination of compact array geometry and atmospheric compensation is necessary to ensure high levels of availability.

Nessel, James A.↗

The Advanced X-ray Spectroscopy and Imaging Observatory (AXSIO)

Following recommendations from the 2010 "New Worlds, New Horizons" (NWNH) report, the Advanced X-ray Spectroscopy and Imaging Observatory (AXSIO) concept streamlines the International X-ray Observatory (IXO) mission to concentrate on the science objectives that are enabled by high-resolution spectroscopic capabilities. AXSIO will trace orbits close to the event horizon of black holes, measure black hole spin for tens of supermassive black holes (SMBH), use spectroscopy to characterize outflows and the environment of AGN during their peak activity, observe 5MBH out to redshift z=6, map bulk motions and turbulence in galaxy clusters, find the missing baryons in the cosmic web using background quasars, and observe the process of cosmic feedback where black holes and supernovae inject energy on galactic and intergalactic scales. These measurements are enabled by a 0.9 sq m collecting area at 1.25 keV, a micro calorimeter array providing high-resolution spectroscopic imaging and a deployable high efficiency grating spectrometer. AXSIO delivers a 30-fold increase in effective area for high resolution spectroscopy. The key simplifications are guided by recommendations in the NWNH panel report include a reduction in focal length from 20m to 10m, eliminating the extendable optical bench, and a reduction in the instrument complement from six to two, avoiding a movable instrument platform. A focus on spectroscopic science allows the spatial resolution requirement to be relaxed to 10 arc sec (with a 5 arc sec goal). These simplifications decrease the total mission cost to under the $2B cost to NASA recommended by NWNH. AXSIO will be available to the entire astronomical community with observing allocations based on peer-review.

White, Nicholas E.↗