Advantages of Dual Mode Imaging for Managing Sensitive Imaging Information
Paper addressing information security management of sensitive images in an Arms Control regime, to be presented at the 2010 INMM Meeting.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Paper addressing information security management of sensitive images in an Arms Control regime, to be presented at the 2010 INMM Meeting.
The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.
Purpose: To evaluate the feasibility of minimally invasive magnetic resonance imaging (MRI)-guided free-hand aspiration of symptomatic nerve route compressing lumbosacral cysts in a 1.0-Tesla (T) open MRI system using a tailored interactive sequence. Materials and Methods: Eleven patients with MRI-evident symptomatic cysts in the lumbosacral region and possible nerve route compressing character were referred to a 1.0-T open MRI system. For MRI interventional cyst aspiration, an interactive sequence was used, allowing for near real-time position validation of the needle in any desired three-dimensional plane. Results: Seven of 11 cysts in the lumbosacral region were successfully aspirated (average 10.1 mm [SD {+-} 1.9]). After successful cyst aspiration, each patient reported speedy relief of initial symptoms. Average cyst size was 9.6 mm ({+-}2.6 mm). Four cysts (8.8 {+-} 3.8 mm) could not be aspirated. Conclusion: Open MRI systems with tailored interactive sequences have great potential for cyst aspiration in the lumbosacral region. The authors perceive major advantages of the MR-guided cyst aspiration in its minimally invasive character compared to direct and open surgical options along with consecutive less trauma, less stress, and also less side-effects for the patient.
This paper presents a unique CMOS linear image sensor for reading the pseudo-random code on the slit disc, focusing on the two aspects of low noise and readout rate. Each pixel is equipped with an exclusive integral readout circuit, and the shape of the pixel also matches the slit disc, making the output signal consistent by up to 99%. After subdivision, the absolute angle data can be captured with an angular resolution of 16 bits and a maximum speed of 7.4 kHz. In addition, decoding and subdivision methods are suitable for high-speed, inexpensive encoder systems.
Not Available
Silicon detectors have been widely used in high energy physics (HEP) experiments. The outstanding properties of silicon detectors include radiation hardness, small material budget, fine spatial resolution, high speed and low cost. In this paper, we report initial results of using a single-bit Monolithic Active Pixel Sensor (MAPS), a leading candidate for the next generation trackers in high luminosity colliders, for hard X-ray imaging. The MAPS responses to X-ray with different energies are obtained and compared with simulation. The observed cluster sizes are larger than that predicted by the Continuous Slowing Down Approximation (CSDA) model, indicating that the charge diffusion process might play an important in the MAPS response to low energy electrons. In conclusion, this work paves the way towards multiple layer ultrafast silicon sensor applications in synchrotrons and XFEL beamlines.
Not Available
Thin ZrO2-4mol% Y2O3 coatings were deposited onto ZrO2 substrates by electron beam-physical vapor deposition. The coated samples revealed a feather-like columnar microstructure. The main phase of the ZrO2-4mol% Y2O3 coatings was the tetragonal phase. To evaluate the influence of the coating’s thickness on the thermal conductivity of thin ZrO2-4mol% Y2O3 coatings, the pulsed thermal imaging method was employed to obtain the thermal conductivity of the coating layer in the two-layer (coating and substrate) samples with thickness between 56 and 337 micrometers. The thermal conductivity of the coating layer was successfully evaluated and compared well with those obtained by the laser flash method for similar coatings. The thermal conductivity of coatings shows an increasing tendency with an increase in the coating’s thickness.
The dynamics of the local environments surrounding molecular polymerization catalysts plausibly impact turnover kinetics, but the impact of and nature of such dynamics have previously been obscured by ensemble averaging. With Grubbs’ second generation ruthenium metathesis catalyst and a precipitation polymerization system, studies at the single-particle and -turnover level establish that (1) an inverse correlation exists between rate and duration of single-polymer–particle growth of aggregates, consistent with a local environment density model for the time-variable kinetics; (2) cross-linking additives produced a small, but detectible, reduction in overall monomer incorporation; (3) total ruthenium quantity within the polymer particles (as characterized by energy dispersive X-ray spectroscopy) is differentiable from the quantity that is catalytically active (as characterized by in situ fluorescence microscopy), providing catalyst speciation information; and (4) time-resolved enyne metathesis reactions can be imaged, corresponding to single turnovers at individual molecular catalysts during polymer growth under synthetically relevant conditions. Here, these findings identify and characterize reactivity distributions likely arising from the dynamics of local environments. As such, these data provide reactivity information that is unavailable through traditional ensemble analytical methods that obscure this type of information through averaging.
A laboratory based high resolution x-ray radiograph was developed for the investigation of solidification dynamics in alloys. It is based on a low-power microfocus x-ray tube and is potentially appropriate for x-ray diagnostics in space. The x-ray microscope offers a high spatial resolution down to approximately 5 {mu}m. Dynamic processes can be resolved with a frequency of up to 6 Hz. In reference experiments, the setup was optimized to yield a high contrast for AlCu-alloys. With samples of about 150 {mu}m thickness, high quality image sequences of the solidification process were obtained with high resolution in time and space.
Understanding the dynamic response of materials at extreme conditions requires diagnostics that can provide real-time, in situ, spatially resolved measurements on the nanosecond timescale. The development of methods such as phase contrast imaging (PCI) typically used at synchrotron sources offer unique opportunities to examine dynamic material response. In this work, we report ultrafast, high-resolution, dynamic PCI measurements of shock compressed materials with 3 {mu}m spatial resolution using a single 60 ps synchrotron X-ray bunch. These results firmly establish the use of PCI to examine dynamic phenomena at ns to {mu}s timescales.
An infrared imaging bolometer diagnostic has been developed recently for the HL-2A tokamak to measure the temporal and spatial distribution of plasma radiation. The three-dimensional tomography, reduced to a two-dimensional problem by the assumption of plasma radiation toroidal symmetry, has been performed. A three-dimensional geometry matrix is calculated with the one-dimensional pencil beam approximation. The solid angles viewed by the detector elements are taken into account in defining the chord brightness. And the local plasma emission is obtained by inverting the measured brightness with the minimum Fisher regularization method. A typical HL-2A plasma radiation model was chosen to optimize a regularization parameter on the criterion of generalized cross validation. Finally, this method was applied to HL-2A experiments, demonstrating the plasma radiated power density distribution in limiter and divertor discharges.
In this study, the close physical proximity of the Gas Puff Imaging (GPI) and Beam Emission Spectroscopy (BES) diagnostics on the National Spherical torus Experiment (NSTX) is leveraged to directly compare fluctuation measurements, and to study the local effects of the GPI neutral deuterium puff during H-mode plasmas without large Edge Localized Modes. The GPI and BES views on NSTX provide partially overlapping coverage of the edge and scrape-off layer (SOL) regions above the outboard midplane. The separation in the toroidal direction is 16°, and field lines passing through diagnostic views are separated by ∼20 cm in the direction perpendicular to the magnetic field. Strong cross-correlation is observed, and strong cross-coherence is seen for frequencies between 5 and 15 kHz. Also, probability distribution functions of fluctuations measured ∼3 cm inside the separatrix exhibit only minor deviations from a normal distribution for both diagnostics, and good agreement between correlation length estimates, decorrelation times, and structure velocities is found at the ±40% level. While the two instruments agree closely in many respects, some discrepancies are observed. Most notably, GPI normalized fluctuation levels exceed BES fluctuations by a factor of ∼9. BES mean intensity is found to be sensitive to the GPI neutral gas puff, and BES normalized fluctuation levels for frequencies between 1 and 10 kHz are observed to increase during the GPI puff.
We demonstrate parabolic single-crystal diamond compound refractive lenses designed for coherent x-ray imaging resilient to extreme thermal and radiation loading expected from next generation light sources. To ensure the preservation of coherence and resilience, the lenses are manufactured from the highest-quality single-crystalline synthetic diamond material grown by a high-pressure high-temperature technique. Picosecond laser milling is applied to machine lenses to parabolic with a similar or equal to 1 mu m precision and surface roughness. A compound refractive lens comprised of six lenses with a radius of curvature R = 200 mu m at the vertex of the parabola and a geometrical aperture A = 900 mu m focuses 10 keV x-ray photons from an undulator source at the Advanced Photon Source facility to a focal spot size of similar or equal to 20 x 90 mu m(2) with a gain factor of similar or equal to 50 - 100. (C) 2015 Author(s).