Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

A Scintillation-Fiber Based Cosmic-ray Muon Tomography System for Imaging Dry Storage Cask

Because of the growth of the nuclear power industry in the United States and the policy decision to ban reprocessing of commercial spent nuclear fuel, the spent fuel inventory at commercial reactor sites has been increasing. Spent nuclear fuel presents extra complexity of security and proliferation issues. These fuel assemblies are practically inaccessible for inspection purposes, as reopening a DSC would require special facilities and would be tremendously expensive. Cosmic-ray muon Tomography has been studied in the past for various applications and was demonstrated to be a good non-destructive assay technique for high-Z materials, such as spent nuclear fuel assemblies in dry storage casks (DSC). Compared to conventional imaging techniques, muon imaging has some advantages due to its negligible health risk and high penetrating power. In this paper, we report our simulation study on imaging a DSC using muon Tomography technique. The Point of Closest Approach (POCA) and the Maximum-Likelihood Expectation- Maximization (ML-EM) algorithms are implemented and evaluated. A scaled-down prototype muon tomography system is proposed and studied. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation Of Satellite Imagery From Aerial Imagery

High-resolution-image data convolved with point-spread function. Report describes use of higher-resolution-image data from aerial photographs or electronic scans of ground to simulate lower resolution images obtained if same area of ground viewed from imaging system in orbit. Simulation technique helpful in analysis of data received from operating satellites and in design of future satellite-borne imaging systems.

Hlavka, Christine A.↗

SU-F-J-204: Carbon Digitally Reconstructed Radiography (CDRR): A GPU Based Tool for Fast and Versatile Carbonimaging Simulation

Purpose: Research in carbon imaging has been growing over the past years, as a way to increase treatment accuracy and patient positioning in carbon therapy. The purpose of this tool is to allow a fast and flexible way to generate CDRR data without the need to use Monte Carlo (MC) simulations. It can also be used to predict future clinically measured data. Methods: A python interface has been developed, which uses information from CT or 4DCT and thetreatment calibration curve to compute the Water Equivalent Path Length (WEPL) of carbon ions. A GPU based ray tracing algorithm computes the WEPL of each individual carbon traveling through the CT voxels. A multiple peak detection method to estimate high contrast margin positioning has been implemented (described elsewhere). MC simulations have been used to simulate carbons depth dose curves in order to simulate the response of a range detector. Results: The tool allows the upload of CT or 4DCT images. The user has the possibility to selectphase/slice of interested as well as position, angle…). The WEPL is represented as a range detector which can be used to assess range dilution and multiple peak detection effects. The tool also provides knowledge of the minimum energy that should be considered for imaging purposes. The multiple peak detection method has been used in a lung tumor case, showing an accuracy of 1mm in determine the exact interface position. Conclusion: The tool offers an easy and fast way to simulate carbon imaging data. It can be used for educational and for clinical purposes, allowing the user to test beam energies and angles before real acquisition. An analysis add-on is being developed, where the used will have the opportunity to select different reconstruction methods and detector types (range or energy). Fundacao para a Ciencia e a Tecnologia (FCT), PhD Grant number SFRH/BD/85749/2012.

60 APPLIED LIFE SCIENCES↗

Population-level Dark Energy Constraints from Strong Gravitational Lensing using Simulation-Based Inference

In this work, we present a scalable approach for inferring the dark energy equation-of-state parameter ($w$) from a population of strong gravitational lens images using Simulation-Based Inference (SBI). Strong gravitational lensing offers crucial insights into cosmology, but traditional Monte Carlo methods for cosmological inference are computationally prohibitive and inadequate for processing the thousands of lenses anticipated from future cosmic surveys. New tools for inference, such as SBI using Neural Ratio Estimation (NRE), address this challenge effectively. By training a machine learning model on simulated data of strong lenses, we can learn the likelihood-to-evidence ratio for robust inference. Our scalable approach enables more constrained population-level inference of $w$ compared to individual lens analysis, constraining $w$ to within $1\sigma$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Population-level Dark Energy Constraints from Strong Gravitational Lensing using Simulation-Based Inference

In this work, we present a scalable approach for inferring the dark energy equation-of-state parameter ($w$) from a population of strong gravitational lens images using Simulation-Based Inference (SBI). Strong gravitational lensing offers crucial insights into cosmology, but traditional Monte Carlo methods for cosmological inference are computationally prohibitive and inadequate for processing the thousands of lenses anticipated from future cosmic surveys. New tools for inference, such as SBI using Neural Ratio Estimation (NRE), address this challenge effectively. By training a machine learning model on simulated data of strong lenses, we can learn the likelihood-to-evidence ratio for robust inference. Our scalable approach enables more constrained population-level inference of $w$ compared to individual lens analysis, constraining $w$ to within $1\sigma$. Our model can be used to provide cosmological constraints from forthcoming strong lens surveys, such as the 4MOST Strong Lensing Spectroscopic Legacy Survey (4SLSLS), which is expected to observe 10,000 strong lenses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Population-level Dark Energy Constraints from Strong Gravitational Lensing using Simulation-Based Inference

In this work, we present a scalable approach for inferring the dark energy equation-of-state parameter ($w$) from a population of strong gravitational lens images using Simulation-Based Inference (SBI). Strong gravitational lensing offers crucial insights into cosmology, but traditional Monte Carlo methods for cosmological inference are computationally prohibitive and inadequate for processing the thousands of lenses anticipated from future cosmic surveys. New tools for inference, such as SBI using Neural Ratio Estimation (NRE), address this challenge effectively. By training a machine learning model on simulated data of strong lenses, we can learn the likelihood-to-evidence ratio for robust inference. Our scalable approach enables more constrained population-level inference of $w$ compared to individual lens analysis, constraining $w$ to within 1$\sigma$. Our model can be used to provide cosmological constraints from forthcoming strong lens surveys, such as the 4MOST Strong Lensing Spectroscopic Legacy Survey (4SLSLS), which is expected to observe 10,000 strong lenses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolution recovery for Compton camera using origin ensemble algorithm

Purpose: Compton cameras (CCs) use electronic collimation to reconstruct the images of activity distribution. Although this approach can greatly improve imaging efficiency, due to complex geometry of the CC principle, image reconstruction with the standard iterative algorithms, such as ordered subset expectation maximization (OSEM), can be very time-consuming, even more so if resolution recovery (RR) is implemented. We have previously shown that the origin ensemble (OE) algorithm can be used for the reconstruction of the CC data. Here we propose a method of extending our OE algorithm to include RR. Methods: To validate the proposed algorithm we used Monte Carlo simulations of a CC composed of multiple layers of pixelated CZT detectors and designed for imaging small animals. A series of CC acquisitions of small hot spheres and the Derenzo phantom placed in air were simulated. Images obtained from (a) the exact data, (b) blurred data but reconstructed without resolution recovery, and (c) blurred and reconstructed with resolution recovery were compared. Furthermore, the reconstructed contrast-to-background ratios were investigated using the phantom with nine spheres placed in a hot background. Results: Our simulations demonstrate that the proposed method allows for the recovery of the resolution loss that is due to imperfect accuracy of event detection. Additionally, tests of camera sensitivity corresponding to different detector configurations demonstrate that the proposed CC design has sensitivity comparable to PET. When the same number of events were considered, the computation time per iteration increased only by a factor of 2 when OE reconstruction with the resolution recovery correction was performed relative to the original OE algorithm. We estimate that the addition of resolution recovery to the OSEM would increase reconstruction times by 2–3 orders of magnitude per iteration. Conclusions: The results of our tests demonstrate the improvement of image resolution provided by the OE reconstructions with resolution recovery. The quality of images and their contrast are similar to those obtained from the OE reconstructions from scans simulated with perfect energy and spatial resolutions.

60 APPLIED LIFE SCIENCES↗

MO-G-17A-02: Computer Simulation Studies for On-Board Functional and Molecular Imaging of the Prostate Using a Robotic Multi-Pinhole SPECT System

Purpose: To investigate prostate imaging onboard radiation therapy machines using a novel robotic, 49-pinhole Single Photon Emission Computed Tomography (SPECT) system. Methods: Computer-simulation studies were performed for region-of-interest (ROI) imaging using a 49-pinhole SPECT collimator and for broad cross-section imaging using a parallel-hole SPECT collimator. A male XCAT phantom was computersimulated in supine position with one 12mm-diameter tumor added in the prostate. A treatment couch was added to the phantom. Four-minute detector trajectories for imaging a 7cm-diameter-sphere ROI encompassing the tumor were investigated with different parameters, including pinhole focal length, pinhole diameter and trajectory starting angle. Pseudo-random Poisson noise was included in the simulated projection data, and SPECT images were reconstructed by OSEM with 4 subsets and up to 10 iterations. Images were evaluated by visual inspection, profiles, and Root-Mean- Square-Error (RMSE). Results: The tumor was well visualized above background by the 49-pinhole SPECT system with different pinhole parameters while it was not visible with parallel-hole SPECT imaging. Minimum RMSEs were 0.30 for 49-pinhole imaging and 0.41 for parallelhole imaging. For parallel-hole imaging, the detector trajectory from rightto- left yielded slightly lower RMSEs than that from posterior to anterior. For 49-pinhole imaging, near-minimum RMSEs were maintained over a broader range of OSEM iterations with a 5mm pinhole diameter and 21cm focal length versus a 2mm diameter pinhole and 18cm focal length. The detector with 21cm pinhole focal length had the shortest rotation radius averaged over the trajectory. Conclusion: On-board functional and molecular prostate imaging may be feasible in 4-minute scan times by robotic SPECT. A 49-pinhole SPECT system could improve such imaging as compared to broadcross-section parallel-hole collimated SPECT imaging. Multi-pinhole imaging can be improved by considering pinhole focal length, pinhole diameter, and trajectory starting angle. The project is supported by the NIH grant 5R21-CA156390.

60 APPLIED LIFE SCIENCES↗

Information-Theoretic Exploration of Multivariate Time-Varying Image Databases

Modern scientific simulations produce very large datasets, making interactive exploration of such data computationally prohibitive. An increasingly common data reduction technique is to store visualizations and other data extracts in a database. The Cinema project is one such approach, storing visualizations in an image database for post hoc exploration and interactive image-based analysis. This work focuses on developing efficient algorithms that can quantify various types of multivariate dependencies existing within multi-variable datasets. It applies specific mutual information measures for the quantification of salient regions from multivariate image data. Here, using such information measures, the opacity of the images is modulated so that the salient regions are automatically highlighted and the domain scientists can interactively explore the most relevant regions for scientific discovery.

97 MATHEMATICS AND COMPUTING↗

Confidence range estimate of extended source imagery acquisition algorithms via computer simulations

Spatial acquisition using the sun-lit Earth as a beacon source provides several advantages over active beacon-based systems for deep-space optical communication systems. However, since the angular extend of the Earth image is large compared to the laser beam divergence, the acquisition subsystem must be capable of resolving the image to derive the proper pointing orientation. The algorithms used must be capable of deducing the receiver location given the blurring introduced by the imaging optics and the large Earth albedo fluctuation. Furthermore, because of the complexity of modelling the Earth and the tracking algorithms, an accurate estimate of the algorithm accuracy can only be made via simulation using realistic Earth images. An image simulator was constructed for this purpose, and the results of the simulation runs are reported.

Chen, CHIEN-C.↗

Three-dimensional model of intracellular and intercellular Ca2+ waves propagation in endothelial cells

Highlights: • Image-based 3D simulation model for intercellular and intracellular Ca{sup 2+} waves. • Metabolic reactions were divided into membrane and cytoplasm domains. • Ca{sup 2+} and IP{sub 3} diffused across the cell and gap junctions. • Ca{sup 2+} waves are propagated from focal stimulated point in numerical simulation. • Ca{sup 2+} wave speed was in agreement with those from cell culture experiments. Intracellular and intercellular Ca{sup 2+} waves play key roles in cellular functions, and focal stimulation triggers Ca{sup 2+} wave propagation from stimulation points to neighboring cells, involving localized metabolism reactions and specific diffusion processes. Among these, inositol 1,4,5-trisphosphate (IP{sub 3}) is produced at membranes and diffuses into the cytoplasm to release Ca{sup 2+} from endoplasmic reticulum (ER). In this study, we developed a three-dimensional (3D) simulation model for intercellular and intracellular Ca{sup 2+} waves in endothelial cells (ECs). 3D model of 2 cells was reconstructed from confocal microscopic images and was connected via gap junctions. Cells have membrane and cytoplasm domains, and metabolic reactions were divided into each domain. Finally, the intracellular and intercellular Ca{sup 2+} wave propagations were induced using microscopic stimulation and were compared between numerical simulations and experiments. The experiments showed that initial sharp increases in intracellular Ca{sup 2+} occurred approximately 0.3 s after application of stimuli. In addition, Ca{sup 2+} wave speeds remained constant in cells, with intracellular and intercellular speeds of approximately 35 and 15 μm/s, respectively. Simulations indicated initial increases in Ca{sup 2+} concentrations at points of stimulation, and these were then propagated across stimulated and neighboring cells. In particular, initial rapid increases in intracellular Ca{sup 2+} were delayed and subsequent intracellular and intercellular Ca{sup 2+} wave speeds were approximately 25 and 12 μm/s, respectively. Simulation results were in agreement with those from cell culture experiments, indicating the utility of our 3D model for investigations of intracellular and intercellular messaging in ECs.

60 APPLIED LIFE SCIENCES↗

Simulation of the ultrasonic array response from real branched cracks using an efficient finite element method

A hybrid model to simulate the ultrasonic array response from stress corrosion cracks is presented. These cracks are branched and difficult to detect so the model is required to enable optimization of an array design. An efficient frequency-domain finite element method is described and selected to simulate the ultrasonic scattering. Experimental validation results are presented, followed by an example of the simulated ultrasonic array response from a real stress corrosion crack whose geometry is obtained from an X-ray Computed Tomography image. A simulation-assisted array design methodology, which includes the model and use of real crack geometries, is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy

Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of patient anatomy on the success rate of real-time markerless tumor tracking using dual-energy imaging. Additionally, the importance of the spectral separation of the imaging beams used to generate the dual-energy images has been shown.

60 APPLIED LIFE SCIENCES↗

Prior data assisted compressed sensing: A novel MR imaging strategy for real time tracking of lung tumors

Purpose: Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal compressed sensing (CS) imaging strategy for the real time MRI–-prior data assisted compressed sensing (PDACS), which aims to improve the image quality of the conventional CS without significantly increasing reconstruction times. Methods: Conventional 2D CS requires a random sampling of partial k-space data, as well as an iterative reconstruction that simultaneously enforces the image's sparsity in a transform domain as well as maintains the fidelity to the acquired k-space. PDACS method requires the additional acquisition of the prior data, and for reconstruction, it additionally enforces fidelity to the prior k-space domain similar to viewsharing. In this work, the authors evaluated the proposed PDACS method by comparing its results to those obtained from the 2D CS and viewsharing methods when performed individually. All three methods are used to reconstruct images from lung cancer patients whose tumors move and who are likely to benefit from lung tumor tracking. The patients are scanned, using a 3T MRI, under free breathing using the fully sampled k-space with 2D dynamic bSSFP sequence in a sagittal plane containing lung tumor. These images form a reference set for the evaluation of the partial k-space methods. To create partial k-space, the fully sampled k-space is retrospectively undersampled to obtain a range of acquisition acceleration factors, and reconstructed with 2D-CS, PDACS, and viewshare methods. For evaluation, metrics assessing global image artifacts as well as tumor contour shape fidelity are determined from the reconstructed images. These analyses are performed both for the original 3T images and those at a simulated 0.5T equivalent noise level. Results: In the 3.0T images, the PDACS strategy is shown to give superior results compared to viewshare and conventional 2D CS using all metrics. The 2D-CS tends to perform better than viewshare at the low acceleration factors, while the opposite is true at the high acceleration factors. At simulated 0.5T images, PDACS method performs only marginally better than the viewsharing method, both of which are superior compared to 2D CS. The PDACS image reconstruction time (0.3 s/image) is similar to that of the conventional 2D CS. Conclusions: The PDACS method can potentially improve the real time tracking of moving tumors by significantly increasing MRI's data acquisition speeds. In 3T images, the PDACS method does provide a benefit over the other two methods in terms of both the overall image quality and the ability to accurately and automatically contour the tumor shape. MRI's data acquisition may be accelerated using the simpler viewsharing strategy at the lower, 0.5T magnetic field, as the marginal benefit of the PDACS method may not justify its additional reconstruction times.

60 APPLIED LIFE SCIENCES↗

CME Flux Rope and Shock Identifications and Locations: Comparison of White Light Data, Graduated Cylindrical Shell Model, and MHD Simulations

Coronal mass ejections (CMEs) are major transient phenomena in the solar corona that are observed with ground-based and spacecraft-based coronagraphs in white light or with in situ measurements by spacecraft. CMEs transport mass and momentum and often drive shocks. In order to derive the CME and shock trajectories with high precision, we apply the graduated cylindrical shell (GCS) model to fit a flux rope to the CME directed toward STEREO A after about 19:00 UT on 29 November 2013 and check the quality of the heliocentric distance-time evaluations by carrying out a three-dimensional magnetohydrodynamic (MHD) simulation of the same CME with the Block Adaptive Tree Solar-Wind Roe Upwind Scheme (BATS-R-US) code. Heliocentric distances of the CME and shock leading edges are determined from the simulated white light images and magnetic field strength data. We find very good agreement between the predicted and observed heliocentric distances, showing that the GCS model and the BATS-R-US simulation approach work very well and are consistent. In order to assess the validity of CME and shock identification criteria in coronagraph images, we also compute synthetic white light images of the CME and shock. We find that the outer edge of a cloud-like illuminated area in the observed and predicted images in fact coincides with the leading edge of the CME flux rope and that the outer edge of a faint illuminated band in front of the CME leading edge coincides with the CME-driven shock front.

Schmidt, J. M.↗

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗